Housing Urban and Rular Development Government Departments Closing in 2 days TDR #56262894

Tender For Conversion Of Sp Shed To Regular Staff Quarters Including Construction Of Shortfall Staff Quarters At Jnv Aurangabad (Bihar)

Issued by Government Departments · Aurangabad, Bihar
Tender Value
4.46 Crore
Estimated cost
Bid Submission
15 Jul 2026
2 days left
EMD
8.94 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Aurangabad → Bihar
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Conversion Of Sp Shed To Regular Staff Quarters Including Construction Of Shortfall Staff Quarters At Jnv Aurangabad (Bihar)

BOQ

Name of Work:- Conversion of SP Shed to regular Staff quarters including construction of shortfall staff quarters at JNV Aurangabad (Bihar)
Sl. No. Item Description
1Discription of work
2STAFF QUARTERS (TYPE-II) (G+2) (11 Nos.)
3Earth Work
4Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
6Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
7Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
8Concrete Work
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
10Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
11Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
12Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand,including necessary excavation,levelling & dressing & finishing the top smooth.
13Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
14Reinforced Cement Concrete
15Centering and shuttering including strutting, propping etc. and removal of form for all heights :
16Foundations, footings, bases of columns, etc. for mass concrete.
17Suspended floors, roofs, landings, balconies and access platform.
18Lintels, beams, plinth beams, girders, bressumers
19Columns,Pillars, Piers, Abutments, Posts and Struts.
20Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
21Edges of slabs and breaks in floors and walls Under 20 cm wide.
22Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
23Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
24Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
25Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
26All works upto plinth level
27Concrete of M25 grade with minimum cementcontent of 330 kg /cum
28(i) R.C.C. work in Footing
29(ii) R.C.C. work in Beam
30(iii) R.C.C. work in Columns
31All works above plinth level upto floor V level
32Concrete of M25 grade with minimum cementcontent of 330 kg /cum
33(i) R.C.C. work in Lintel
34(ii) R.C.C. work in Beam
35(iii) R.C.C. work in Columns
36(iv) R.C.C. work in Slab
37Masonry Work
38Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
39Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
40Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in superstructure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand)
41Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
42Cladding Work
43Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
44Granite stone slab colour black, Cherry/Ruby red
45Area of slab upto 0.50 sqm
46Area of slab over 0.50 sqm
47Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
48Granite work
49Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
50Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
51Providing and fixing Ist quality Glazed vitrified tiles polished finish of size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
52Wood and PVC Work
53Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
54Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
55Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
56Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. Twin rubber stopper
57Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges of required size Kiln seasoned and chemically treated hollock wood
58Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm.
59Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
60Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
61200 x 10mm
62150 x 10mm
63CUPBOARD / WARDROBE
64Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately)
6518 mm thick
6625 mm thick
67Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain white color board for backing of cup boards and bathroom/kitchen cabinets etc. of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel screws etc. all as per direction of Engineer-In- Charge. (Note: stainless steel screws shall be paid separately)
686 mm thick
69Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 200 mm
70Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. 100 mm for Kitchen Cabinets
71Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge
72Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.
73Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket,Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge.(For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc.Payment of providing and fixing telescopic channel shall be paid separately)
74SS Hanging Rod for CB
75Providing and fixing 25 mm dia. SS pipe Hanging rods with SS brackets :
76Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work
77Steel Work
78Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
79Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
80Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
81ALUMINIUM WORK
82System Aluminium Factory made Double Rebate Windows with Grill and Mesh Providing and fixing of A2Z Series Double rebate windows & ventilators made of High-performance factory-made system Aluminium windows with Akzonobel powder coating of 60-70 microns (Any RAL Colour). Section for Outer frame should be a single section of 91mm x 35mm, Glass shutter frame shall be of 54mm x 30mm, Mesh shutter frame shall be of 54mm x 30mm, 5mm thick Single Glazed beading shall be of 15mm x 18mm. 5mm thick Clear Tuffened Glass shall be used in all the windows & ventilators. Stainless Steel Wire Mesh shall be used in Wire mesh Shutters. No Coupling of 2 windows shall be allowed in any type of design. 10mm Sq bar M.S. Grill/Guard bar with 150mm c/c shall be fixed in between glass & mesh shutter. All frame corners shall be joined/assembled using self-locating corner cleats (No screwing at corners shall be allowed). All Hardware shall be used from a reputed brand, weather silicon shall be used for filling the gap between window opening & window Frame complete in all respect including all taxes.
83Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
84Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
85Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
86Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
87Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
88Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well a curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
89Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
90Providing and fixing machine cut, mirror/ eggshell polished , granite work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charg .Granite of all colour except black, cherry/ruby red 18 mm thick (slab area above 0.50 sqm)
91Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main\\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main\\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of allT-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
9212.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardantPVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back sidemetalized polyester film so as to make the tile a completely sealed unit.
93Finishing
94External Plaster in CM 1:4 with18mm thick in Two coats comprising of first layer 12mm thick cement plaster finished with a top layer 6mm thick cement plaster cement: 4 coarse sand)
95Rate for First layer 12mm thick cement plaster DSR item No. 13.4.1=Rs. 357.35
96Rate for top layer 6mm thick cement plaster cement DSR item No. 13.4.1=Rs. 357.35/2=153.63
97Total Rate For 18mm Thick Plaster=357.35+178.68=536.03
98Extra for providing and mixing water proofing material in cement of plaster work in proportion recommended by the manufacturers.
9912mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand)
1006 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
101Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
102Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primerapplied @ 0.90 litre/10 sqm.
103Steel Painting:Applying priming coat:
104With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
105With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
106Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
107Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
108Water Proofing
109Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
110(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
111(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
112(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
113(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
114(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
115With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
116PLUMBING ESTIMATE ( STAFF QUARTERS (TYPE-II) (11 Nos.) )
117SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
118Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
119White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
120Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
121Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
122Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
123White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
124Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
125Kitchen Sink with drain board
126510 x 1040 mm bowl depth 250 mm
127Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
12815 mm nominal bore
129Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
13015 mm nominal bore
131Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
13215 mm nominal bore
133Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
13415 mm nominal bore
135Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
136Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
13732 mm dia
13840 mm dia
139Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
140Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
141Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
142600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
143Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
144Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
145Providing & fixing toilet paper holder:
146C.P.brass
147Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
14815 mm nominal bore with 45cm length
149Providing and fixing CP brass shower rose with 15 or 20 mm inlet
150100 mm diameter
151Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
15215 mm nominal dia
153Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
154Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
155Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
156Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
157Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
15815 Litre Capacity
15925 Litre Capacity
160SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
161Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
162Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
163Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
164Stone ware Spout
165Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
166Single Socketed Pipes
16775 mm diameter
168110 mm diameter
169Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
170Coupler
17175 mm diameter
172110 mm diameter
173Single Push Fit Coupler
17475 mm diameter
175110 mm diameter
176Single Tee with door
17775x75x75 mm
178110x110x110 mm
179Single Tee without door
18075x75x75 mm
181110x110x110 mm
182Bend 87.5 degree
18375 mm bend
184110 mm bend
185Shoe ( Plain )
18675 mm Shoe
187110 mm Shoe
188Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
18975 mm diameter
190110 mm diameter
191Providing and Fixing Soil , Waste and Vent Pipes :
192100 mm dia
193Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
19475 mm dia
195Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
196Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
19775 mm dia Pipe
198100 mm dia Pipe
199Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
200For 100 mm dia Pipe
201For 75 mm dia Pipe
202Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
203100 mm dia
204Sand Cast iron S & S as per IS : 3989
205Providing and Fixing Plain Bend of Required degree .
206100 mm dia
207Sand Cast iron S & S as per IS : 3989
208Providing and Fixing Heel Rest Sanitary Bend
209100 mm dia
210Spun Cast Iron as per IS : 3989
211Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
212100x100x100x100 mm
213Spun Cast Iron as per IS : 3989
21475x75x75x75 mm
215Spun Cast Iron as per IS : 3989
216Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
217100x100x100 mm
218Sand Cast Iron S&S as per IS : 3989
21975x75x75 mm
220Sand Cast Iron S&S as per IS : 3989
221Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
222100 x 100 x 75 mm
223Sand Cast Iron S & S as per IS : 3989
224Providing and Fixing Single Unequal Plain Junction of Required degree .
225100 x 100 x 75 mm
226Sand Cast Iron S & S as per IS : 3989
227Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
228150 mm off sets
229With 75 mm dia Pipe
230With 100 mm dia Pipe
231Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
232100 mm
233Spun Cast Iron as per IS : 3989
23475 mm
235Spun Cast Iron as per IS : 3989
236Providing and Fixing Terminal Guard :
237100 mm
238Sand Cast Iron S & S as per IS : 3989
23975 mm
240Sand Cast Iron S & S as per IS : 3989
241Providing and Fixing Collar :
242100 mm
243Sand Cast Iron S & S as per IS : 3989
24475 mm
245Sand Cast Iron S & S as per IS : 3989
246Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
247100 mm dia pipe
24875 mm dia pipe
249Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
250100 mm dia pipe
25175 mm dia pipe
252Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
253100 mm inlet and 100 mm outlet
254Sand Cast Iron S & S as per IS : 3989
255Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
256100 mm diameter Pipes
25775 mm diameter Pipes
258Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
259Internal Work - Exposed on Wall
26032 mm dia nominal bore
26140 mm dia nominal bore
26250 mm dia nominal bore
263Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
26432 mm diameter pipe
26540 mm diameter pipe
26650 mm diameter pipe
267Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
268Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
269Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
270100 mm diameter Pipe
271150 mm diameter Pipe
272Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
273SUB HEAD - III : INTERNAL WATER SUPPLY
274Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
27515 mm dia pipes
27620 mm dia pipes
27725 mm dia pipes
27832 mm dia pipes
27940 mm dia pipes
28050 mm dia pipes
281Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
28215 mm dia pipes
28320 mm dia pipes
28425 mm dia pipes
28532 mm dia pipes
28640 mm dia pipes
28750 mm dia pipes
288Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
28915 mm dia pipes
29020 mm dia pipes
29125 mm dia pipes
29232 mm dia pipes
29340 mm dia pipes
29450 mm dia pipes
29565 mm dia pipes
29680 mm dia pipes
297Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
29815 mm dia pipes
29920 mm dia pipes
30025 mm dia .Pipes.
30132 mm dia .Pipes.
302Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
3039 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
304For 15 mm dia Pipe
305For 20 mm dia Pipe
306For 25 mm dia Pipe
307For 32 mm dia Pipe
308For 40 mm dia Pipe
309For 50 mm dia Pipe
310Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
31140 mm dia Pipe
31250 mm dia Pipe
313Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
31415 mm dia
31520 mm dia
31625 mm dia
31732 mm dia
31840 mm dia
31950 mm dia
320INTERNAL ELECTRICAL WORK (STAFF QUARTERS ) (TYPE-II) (11 Nos.)
321SUB HEAD - I: CIRCUIT CUM POINT WIRING
322SWITCH CONTROL LIGHT POINTS
323Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
324Group A
325Group B
326Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
327Group A
328Group B
329MCB CONTROL LIGHT POINTS
330Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
331Primary point controlled by one MCB.
332Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
333Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
3342 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3352 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3362 X 4 sq. mm + 1 X 4 sq. mm earth wire
3372 X 6 sq. mm + 1 X 6 sq. mm earth wire
3382 x 10 sq. mm + 1 x 6 sq.mm earth wire
3394 X 10 sq. mm + 2 X 6 sq. mm earth wire
3404 X 16 sq. mm + 2 X 6 sq. mm earth wire
341Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
342Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
343Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
344Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
345Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
346Telephone socket outlet
347TV antenna socket outlet
348Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3491 or 2 Module (75mmX75mm)
3506 module (78mm X 205 mm X 50 mm)
351Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3523 pin , 5/6 amps socket outlet
3535/6 amps switch
354Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
35525 mm
35632 mm
357SUBHEAD -II - FITTINGS & FIXTURES
358Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
359Supply, Installation, Testing and Commissioning of 5W Mirror Light.
360Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
3618-10 Watt
36212-15 Watt
36318 Watt
364Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
36518-22 Watt
366Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
367Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
3681200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
369Supply, installation, Testing and commissioning of 250mm Exhaust fan.
370Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
371SUBHEAD - III - DISTRIBUTION BOARDS
372Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3736 way, Double door
3748 way, Double door
37512 way, Double door
376Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
3776 way (4 + 18), Double door
3788 way (4 + 24), Double door
379Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
380Single Pole
381Single Pole Neutral
382Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
383Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
384Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
385Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
386SUB HEAD -IV - LT CABLES & CABLE TRAYS
387Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
388Up to 35 sq mm.
389Above 35 sq mm and up to 95 sq mm.
390Above 95 sq mm and up to 185 sq mm.
391Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
392Upto 35 sq.mm
393Above 35 sq. mm and upto 95 sq. mm
394Above 95 sq.mm and upto 185 sq.mm
395S/ F powder coated of approved shade MS Cable Trays
396Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
397100 mm width X 50 mm depth X 1.6 mm thickness
398150 mm width X 50 mm depth X 1.6 mm thickness
399300 mm width X 50 mm depth X 1.6 mm thickness
400S/ F powder coated of approved shade MS Cable Tray Bends
401Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
402100 mm width X 50 mm depth X 1.6 mm thickness
403150 mm width X 50 mm depth X 1.6 mm thickness
404S/ F powder coated of approved shade MS Cable Tray Tee's
405Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
406100 mm width X 50 mm depth X 1.6 mm thickness
407150 mm width X 50 mm depth X 1.6 mm thickness
408Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
4094 X 10 sq. mm (28mm)
4104 X 16 sq. mm (28mm)
4113½ X 35 sq. mm (32mm)
4123½ X 50 sq. mm (35mm)
4133½ X 95 sq. mm (38mm)
4143½ X 120 sq. mm (38mm)
415XLPE Insulated Copper Armoured Cables
4162C x 6 Sq.mm.
4172C x 4 Sq.mm.
4183C x 6 Sq.mm.
4193C x 4 Sq.mm.
4204CX 2.5 Sq.mm
4214C x 4 Sq.mm.
422Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
423SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
4244C/3C x 6/4 sq.mm.
425Single Compression Gland for Cu. Cable
4264C/3C/2C x 4/6/2.5 sq.mm.
427Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
4284 X 10 sq. mm (25mm)
4294 X 16 sq. mm (28mm)
4303½ X 25 sq. mm (28mm)
4313½ X 35 sq. mm (32mm)
4323½ X 50 sq. mm (35mm)
4333½ X 95 sq. mm (45mm)
4343½ X 120 sq. mm (45mm)
435SUB HEAD -V - EARTHING SYSTEM
436Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
437Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
438Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
439Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
440SUB HEAD - VI :LIGHTNING CONDUCTOR
441Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
442Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
443Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
444Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
445Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
446Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
447Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
448Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
449TYPE-III RESIDENCES (G) 2 UNITS
450Earth Work
451Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge..All kinds of soil.
452Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
453Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
454Concrete Work
455Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
456Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
457Providing & applying a coat of residual petroleum bitumen of grade of Vg-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
458Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zoneiii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
459Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
460Brick Drain along Plinth Protection (Size 250X300 MM )
461Reinforced Cement Concrete
462Centering and shuttering including strutting, propping etc. and removal of form for
463Foundations, footings, bases of columns, etc. for mass concrete.
464Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
465Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
466Columns,Pillars, Piers, Abutments, Posts and Struts.
467Edges of slabs and breaks in floors and walls Under 20 cm wide.
468Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-mechanically treated bars of grade fe-500D or more.
469Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-mechanically treated bars of grade fe-500D or more.
470Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
471Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and Reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
472All works upto plinth level
473Concrete of M25 grade with minimum cementcontent of 330 kg /cum
474(i) R.C.C. work in Footing
475(ii) R.C.C. work in Beam
476(iii) R.C.C. work in Columns
477All works above plinth level upto floor V level
478Concrete of M25 grade with minimum cementcontent of 330 kg /cum
479(i) R.C.C. work in Lintel
480(ii) R.C.C. work in Beam
481(iii) R.C.C. work in Columns
482(iv) R.C.C. work in Slab
483Masonry Work
484Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. : cement mortar 1:4 (1 cement : 4 coarse sand)
485Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
486Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
487Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
488Cladding Work
489Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
490Granite stone slab colour black, Cherry/Ruby red
491Area of slab upto 0.50 sqm
492Area of slab over 0.50 sqm
493Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
494Granite work
495Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
496Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
497Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. MINMUM SIZE OF TILE 300 MM X450 MM
498Wood and PVC Work
499Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
500Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
501Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
502Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete.
503300 mm weighing not less than 200 gms
504250 mm weighing not less than 150 gms
505Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
506Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
507Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm
508Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete.(a) 250mm x 16mm .
509Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
510200 x 10mm
511150 x 10mm
512Steel Work
513Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
514Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
515Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
516Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
517Flooring
518Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
519Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
520Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
521Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm
522Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x600 mm
523Finishing
52415 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
52512 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
5266 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
527Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
528Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
529Applying priming coat:
530With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
531With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
532Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
533Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
534Water Proofing
535Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
536(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
537(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
538(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
539(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
540(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
541With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
542PLUMBING ESTIMATE (TYPE-III RESIDENCES (G) 1 UNIT )
543SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
544Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
545White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
546Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
547Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
548Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
549White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
550Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
551Kitchen Sink with drain board
552510 x 1040 mm bowl depth 250 mm
553Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
55415 mm nominal bore
555Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
55615 mm nominal bore
557Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
55815 mm nominal bore
559Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
56015 mm nominal bore
561Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
562Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
56332 mm dia
56440 mm dia
565Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
566Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
567Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
568600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
569Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
570Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
571Providing & fixing toilet paper holder:
572C.P.brass
573Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
57415 mm nominal bore with 45cm length
575Providing and fixing CP brass shower rose with 15 or 20 mm inlet
576100 mm diameter
577Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
57815 mm nominal dia
579Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
580Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
581Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
582Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
583Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
58415 Litre Capacity
58525 Litre Capacity
586SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
587Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
588Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
589Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
590Stone ware Spout
591Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
592Single Socketed Pipes
59375 mm diameter
594110 mm diameter
595Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
596Coupler
59775 mm diameter
598110 mm diameter
599Single Push Fit Coupler
60075 mm diameter
601110 mm diameter
602Single Tee with door
60375x75x75 mm
604110x110x110 mm
605Single Tee without door
60675x75x75 mm
607110x110x110 mm
608Bend 87.5 degree
60975 mm bend
610110 mm bend
611Shoe ( Plain )
61275 mm Shoe
613110 mm Shoe
614Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
61575 mm diameter
616110 mm diameter
617Providing and Fixing Soil , Waste and Vent Pipes :
618100 mm dia
619Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
62075 mm dia
621Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
622Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
62375 mm dia Pipe
624100 mm dia Pipe
625Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
626For 100 mm dia Pipe
627For 75 mm dia Pipe
628Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
629100 mm dia
630Sand Cast iron S & S as per IS : 3989
631Providing and Fixing Plain Bend of Required degree .
632100 mm dia
633Sand Cast iron S & S as per IS : 3989
634Providing and Fixing Heel Rest Sanitary Bend
635100 mm dia
636Spun Cast Iron as per IS : 3989
637Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
638100x100x100x100 mm
639Spun Cast Iron as per IS : 3989
64075x75x75x75 mm
641Spun Cast Iron as per IS : 3989
642Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
643100x100x100 mm
644Sand Cast Iron S&S as per IS : 3989
64575x75x75 mm
646Sand Cast Iron S&S as per IS : 3989
647Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
648100 x 100 x 75 mm
649Sand Cast Iron S & S as per IS : 3989
650Providing and Fixing Single Unequal Plain Junction of Required degree .
651100 x 100 x 75 mm
652Sand Cast Iron S & S as per IS : 3989
653Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
654150 mm off sets
655With 75 mm dia Pipe
656With 100 mm dia Pipe
657Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
658100 mm
659Spun Cast Iron as per IS : 3989
66075 mm
661Spun Cast Iron as per IS : 3989
662Providing and Fixing Terminal Guard :
663100 mm
664Sand Cast Iron S & S as per IS : 3989
66575 mm
666Sand Cast Iron S & S as per IS : 3989
667Providing and Fixing Collar :
668100 mm
669Sand Cast Iron S & S as per IS : 3989
67075 mm
671Sand Cast Iron S & S as per IS : 3989
672Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
673100 mm dia pipe
67475 mm dia pipe
675Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
676100 mm dia pipe
67775 mm dia pipe
678Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
679100 mm inlet and 100 mm outlet
680Sand Cast Iron S & S as per IS : 3989
681Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
682100 mm diameter Pipes
68375 mm diameter Pipes
684Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
685Internal Work - Exposed on Wall
68632 mm dia nominal bore
68740 mm dia nominal bore
68850 mm dia nominal bore
689Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
69032 mm diameter pipe
69140 mm diameter pipe
69250 mm diameter pipe
693Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
694Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
695Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
696100 mm diameter Pipe
697150 mm diameter Pipe
698Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
699SUB HEAD - III : INTERNAL WATER SUPPLY
700Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
70115 mm dia pipes
70220 mm dia pipes
70325 mm dia pipes
70432 mm dia pipes
70540 mm dia pipes
70650 mm dia pipes
707Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
70815 mm dia pipes
70920 mm dia pipes
71025 mm dia pipes
71132 mm dia pipes
71240 mm dia pipes
71350 mm dia pipes
714Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
71515 mm dia pipes
71620 mm dia pipes
71725 mm dia pipes
71832 mm dia pipes
71940 mm dia pipes
72050 mm dia pipes
72165 mm dia pipes
72280 mm dia pipes
723Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
72415 mm dia pipes
72520 mm dia pipes
72625 mm dia .Pipes.
72732 mm dia .Pipes.
728Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
7299 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
730For 15 mm dia Pipe
731For 20 mm dia Pipe
732For 25 mm dia Pipe
733For 32 mm dia Pipe
734For 40 mm dia Pipe
735For 50 mm dia Pipe
736Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
73740 mm dia Pipe
73850 mm dia Pipe
739Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
74015 mm dia
74120 mm dia
74225 mm dia
74332 mm dia
74440 mm dia
74550 mm dia
746INTERNAL ELECTRICAL WORK (TYPE-III RESIDENCES (G) 1 UNIT)
747SUB HEAD - I: CIRCUIT CUM POINT WIRING
748SWITCH CONTROL LIGHT POINTS
749Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
750Group A
751Group B
752Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
753Group A
754Group B
755MCB CONTROL LIGHT POINTS
756Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
757Primary point controlled by one MCB.
758Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
759Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
7602 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
7612 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
7622 X 4 sq. mm + 1 X 4 sq. mm earth wire
7632 X 6 sq. mm + 1 X 6 sq. mm earth wire
7642 x 10 sq. mm + 1 x 6 sq.mm earth wire
7654 X 10 sq. mm + 2 X 6 sq. mm earth wire
7664 X 16 sq. mm + 2 X 6 sq. mm earth wire
767Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
768Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
769Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
770Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
771Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
772Telephone socket outlet
773TV antenna socket outlet
774Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
7751 or 2 Module (75mmX75mm)
7766 module (78mm X 205 mm X 50 mm)
777Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
7783 pin , 5/6 amps socket outlet
7795/6 amps switch
780Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
78125 mm
78232 mm
783SUBHEAD -II - FITTINGS & FIXTURES
784Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
785Supply, Installation, Testing and Commissioning of 5W Mirror Light.
786Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
7878-10 Watt
78812-15 Watt
78918 Watt
790Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
79118-22 Watt
792Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
793Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
7941200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
795Supply, installation, Testing and commissioning of 250mm Exhaust fan.
796Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
797SUBHEAD - III - DISTRIBUTION BOARDS
798Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
7996 way, Double door
8008 way, Double door
80112 way, Double door
802Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
8036 way (4 + 18), Double door
8048 way (4 + 24), Double door
805Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
806Single Pole
807Single Pole Neutral
808Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
809Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
810Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
811Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
812SUB HEAD -IV - LT CABLES & CABLE TRAYS
813Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
814Up to 35 sq mm.
815Above 35 sq mm and up to 95 sq mm.
816Above 95 sq mm and up to 185 sq mm.
817Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
818Upto 35 sq.mm
819Above 35 sq. mm and upto 95 sq. mm
820Above 95 sq.mm and upto 185 sq.mm
821S/ F powder coated of approved shade MS Cable Trays
822Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
823100 mm width X 50 mm depth X 1.6 mm thickness
824150 mm width X 50 mm depth X 1.6 mm thickness
825300 mm width X 50 mm depth X 1.6 mm thickness
826S/ F powder coated of approved shade MS Cable Tray Bends
827Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
828100 mm width X 50 mm depth X 1.6 mm thickness
829150 mm width X 50 mm depth X 1.6 mm thickness
830S/ F powder coated of approved shade MS Cable Tray Tee's
831Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
832100 mm width X 50 mm depth X 1.6 mm thickness
833150 mm width X 50 mm depth X 1.6 mm thickness
834Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
8354 X 10 sq. mm (28mm)
8364 X 16 sq. mm (28mm)
8373½ X 35 sq. mm (32mm)
8383½ X 50 sq. mm (35mm)
8393½ X 95 sq. mm (38mm)
8403½ X 120 sq. mm (38mm)
841XLPE Insulated Copper Armoured Cables
8422C x 6 Sq.mm.
8432C x 4 Sq.mm.
8443C x 6 Sq.mm.
8453C x 4 Sq.mm.
8464CX 2.5 Sq.mm
8474C x 4 Sq.mm.
848Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
849SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
8504C/3C x 6/4 sq.mm.
851Single Compression Gland for Cu. Cable
8524C/3C/2C x 4/6/2.5 sq.mm.
853Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
8544 X 10 sq. mm (25mm)
8554 X 16 sq. mm (28mm)
8563½ X 25 sq. mm (28mm)
8573½ X 35 sq. mm (32mm)
8583½ X 50 sq. mm (35mm)
8593½ X 95 sq. mm (45mm)
8603½ X 120 sq. mm (45mm)
861SUB HEAD -V - EARTHING SYSTEM
862Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
863Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
864Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
865Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
866SUB HEAD - VI :LIGHTNING CONDUCTOR
867Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
868Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
869Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
870Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
871Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
872Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
873Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
874Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
875PRINCIPAL RESIDENCE
876Earth Work
877Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
878Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
879Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
880Concrete Work
881Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
882Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
883Providing & applying a coat of residual petroleum bitumen of grade of Vg-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
884Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zoneiii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
885Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
886Brick Drain along Plinth Protection (Size 250X300 MM )
887Reinforced Cement Concrete
888Centering and shuttering including strutting, propping etc. and removal of form for
889Foundations, footings, bases of columns, etc. for mass concrete.
890Suspended floors, roofs, landings, balconies and access platform
891Lintels, beams, plinth beams, girders, bressumers and cantilevers
892Columns,Pillars, Piers, Abutments, Posts and Struts.
893Edges of slabs and breaks in floors and walls Under 20 cm wide.
894Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
895Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-mechanically treated bars of grade fe-500D or more.
896Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
897Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland Slag cement, admixtures in recommended proportions as per iS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and Reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
898All works upto plinth level
899Concrete of M25 grade with minimum cementcontent of 330 kg /cum
900(i) R.C.C. work in Footing
901(ii) R.C.C. work in Beam
902(iii) R.C.C. work in Columns
903All works above plinth level upto floor V level
904Concrete of M25 grade with minimum cementcontent of 330 kg /cum
905(i) R.C.C. work in Lintel
906(ii) R.C.C. work in Beam
907(iii) R.C.C. work in Columns
908(iv) R.C.C. work in Slab
909Masonry Work
910Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
911Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
912Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry.
913Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
914Cladding Work
915Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
916Granite stone slab colour black, Cherry/Ruby red
917Area of slab upto 0.50 sqm
918Area of slab over 0.50 sqm
919Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
920Granite work
921Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
922Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
923Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. MINMUM SIZE OF TILE 300 MM X450 MM
924Wood and PVC Work
925Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) nondecorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
926Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
927Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
928Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
929Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
930Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm
931Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
932Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
933200 x 10mm
934150 x 10mm
935Steel Work
936Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
937Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
938Supply & fixing of Aluminium 3 Track Sliding windows with Grill as per design & specifications with outer frame 86.5mm X 48mm, Shutter section 65mm X 29mm, Mesh Shutter 66.7mm X 29mm, Powder coated (any RAL Colour), 6mm Clear tuffened glass, Wire Mesh, Handle, EPDM Gasket, Silicon sealant, 10mm Sq bar M.S. Grill/Guard bar with 150mm c/c shall be integrated in the windows with complete hardware of reputed brand,
939Flooring
940Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
941Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
942Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
943Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm
944Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.size of tile 600x600 mm
945Finishing
94615 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)
94712 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
9486 mm cement plaster on celling (a) 1:3(1 cement:3 fine sand)
949Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
950Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
951Applying priming coat:
952With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
953With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
954Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
955Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
956Water Proofing
957Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
958(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
959(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
960(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
961(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
962(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:
963With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
964PLUMBING ESTIMATE (PRINCIPAL RESIDENCE )
965SUB HEAD - I : SANITARY FIXTURES ( PROVIDING AND FIXING )
966Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
967White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
968Providing and Fixing White Viterous China Extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing and fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litre ) including seat cover and cistern fittings nuts bolts and gaskets etc complete .
969Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C. pan with ISI marked white solid plastic seat and lid
970Providing and fixing wash basin with C.I. brackets 15 mm dia CP brass single hole basin mixer of approved quality and make including painting of fittings and brackets cutting and making good the walls wherever required
971White Viterous china Wash basin size 550x400 mm with a 15 mm CP brass single hole basin mixer
972Providing and Fixing Stainless Steel A ISI 304 ( 18/8 ) kitchen sink as per IS : 13983 with CI Brackets and stainless steel plug 40 mm , including painting of fittings and brackets , cutting and making good the walls wherever required .
973Kitchen Sink with drain board
974510 x 1040 mm bowl depth 250 mm
975Providing and Fixing CP brass bib cock of approved quality conforming to IS : 8931
97615 mm nominal bore
977Providing and Fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms .
97815 mm nominal bore
979Providing and Fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931
98015 mm nominal bore
981Providing and Fixing CP brass stop cock ( concealed ) of standard design and of approved make conforming to IS : 8931
98215 mm nominal bore
983Providing and placing on terrace ( at all floor levels ) polythylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank .
984Providing & fixing of Waste pipe for Wash basins & Sinks including pvc waste fittings complete.
98532 mm dia
98640 mm dia
987Providing & fixing PTMT liquid soap container 109mm wide,125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
988Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
989Providing & fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P brass screws with concealed fitting arangement of approved quality and colour.
990600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gram.less
991Providing & fixing PTMT soap dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements.Weighing not less than 106gms.
992Providing & fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass Screws and washers complete .
993Providing & fixing toilet paper holder:
994C.P.brass
995Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
99615 mm nominal bore with 45cm length
997Providing and fixing CP brass shower rose with 15 or 20 mm inlet
998100 mm diameter
999Providing & Fixing CP brass single lever telephonic wall mixer of quality and make as approved by engineer - in - charge .
100015 mm nominal dia
1001Providing and Fixing White Viterous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption ) , having water inlet from back side , including fixing to wall with suitable brackets all as per manufacturer specification and direction of engineer - in - charge .
1002Providing & fixing C.P. brass Central hole wall mounted sink Mixer with aerator connecting legs & 2 nos CP brass wall flange and 2 nos CP brass stop cock including cutting & making good the walls wherever required complete in all respect as per direction of engineer - in - charge .
1003Providing and fixing C.P. brass Double coat hooks fixed in Toilet wall with C.P brass wall flanges & C.P. brass screws and other required accessories complete in all respect as per direction of engineer - in - charge .
1004Providing and fixing health faucet with 1 m CP brass flexible tube and swivel hook with CP brass wall flange including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge .
1005Providing and fixing vertical or horizontal storage type hot water heater electrical operated fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug .
100615 Litre Capacity
100725 Litre Capacity
1008SUB HEAD - II : INTERNAL DRAINAGE (RAINWATER, SOIL, WASTE & FITTINGS)
1009Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
1010Providing and Fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams .
1011Providing and Fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 ( 1 Cement : 4 Fine Sand )
1012Stone ware Spout
1013Providing and Fixing on wall face Unplasticised rigid pvc rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
1014Single Socketed Pipes
101575 mm diameter
1016110 mm diameter
1017Providing and Fixing on wall face Rigid Unplasticised UPVC moulded fittings / accessories for unplasticised Rigid PVC Rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion .
1018Coupler
101975 mm diameter
1020110 mm diameter
1021Single Push Fit Coupler
102275 mm diameter
1023110 mm diameter
1024Single Tee with door
102575x75x75 mm
1026110x110x110 mm
1027Single Tee without door
102875x75x75 mm
1029110x110x110 mm
1030Bend 87.5 degree
103175 mm bend
1032110 mm bend
1033Shoe ( Plain )
103475 mm Shoe
1035110 mm Shoe
1036Providing and Fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs , screwed with MS screws of required length , including cutting brick work with fixing in cement mortar 1:4 ( 1 Cement : 4 Coarse Sand ) and making good the wall etc . complete
103775 mm diameter
1038110 mm diameter
1039Providing and Fixing Soil , Waste and Vent Pipes :
1040100 mm dia
1041Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
104275 mm dia
1043Centrifugally cast ( spun ) iron socket and spigot ( S & S ) pipe as per IS : 3989
1044Providing and Filling the joints with spun yarn , cement slurry and cement mortar 1 : 2 ( 1 Cement : 2 fine Sand ) in SCI / CI Pipes :
104575 mm dia Pipe
1046100 mm dia Pipe
1047Providing and Fixing MS holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of cement concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal sizes ) including cost of cutting holes and making good the walls etc .
1048For 100 mm dia Pipe
1049For 75 mm dia Pipe
1050Providing and Fixing Bend of Required degree with access door , insertion rubber washers 3 mm thick , bolts and nuts complete .
1051100 mm dia
1052Sand Cast iron S & S as per IS : 3989
1053Providing and Fixing Plain Bend of Required degree .
1054100 mm dia
1055Sand Cast iron S & S as per IS : 3989
1056Providing and Fixing Heel Rest Sanitary Bend
1057100 mm dia
1058Spun Cast Iron as per IS : 3989
1059Providing and Fixing Double Equal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1060100x100x100x100 mm
1061Spun Cast Iron as per IS : 3989
106275x75x75x75 mm
1063Spun Cast Iron as per IS : 3989
1064Providing and Fixing Single Equal Plain Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1065100x100x100 mm
1066Sand Cast Iron S&S as per IS : 3989
106775x75x75 mm
1068Sand Cast Iron S&S as per IS : 3989
1069Providing and Fixing Single Unequal Junction of Required degree with access door , insertion rubber washer 3 mm thick , bolts and nuts complete .
1070100 x 100 x 75 mm
1071Sand Cast Iron S & S as per IS : 3989
1072Providing and Fixing Single Unequal Plain Junction of Required degree .
1073100 x 100 x 75 mm
1074Sand Cast Iron S & S as per IS : 3989
1075Providing and Fixing Sand Cast Iron S & S offsets as per IS : 3989
1076150 mm off sets
1077With 75 mm dia Pipe
1078With 100 mm dia Pipe
1079Providing and Fixing door piece , insertion rubber washer 3 mm thick , bolts and nuts complete .
1080100 mm
1081Spun Cast Iron as per IS : 3989
108275 mm
1083Spun Cast Iron as per IS : 3989
1084Providing and Fixing Terminal Guard :
1085100 mm
1086Sand Cast Iron S & S as per IS : 3989
108775 mm
1088Sand Cast Iron S & S as per IS : 3989
1089Providing and Fixing Collar :
1090100 mm
1091Sand Cast Iron S & S as per IS : 3989
109275 mm
1093Sand Cast Iron S & S as per IS : 3989
1094Providing Lead Caulked Joints to Sand Cast iron / centrifugally cast spun iron pipes and fittings of diameter :
1095100 mm dia pipe
109675 mm dia pipe
1097Providing and Fixing MS Stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter :
1098100 mm dia pipe
109975 mm dia pipe
1100Providing and Fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete , including cost of cutting and making good the walls and floors .
1101100 mm inlet and 100 mm outlet
1102Sand Cast Iron S & S as per IS : 3989
1103Painting Sand cast iron / centrifugally cast ( spun ) iron soil , waste , vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey , or buff etc . Over a coat of primer ( of approved quality ) for new work :
1104100 mm diameter Pipes
110575 mm diameter Pipes
1106Providing and Fixing GI Pipes complete with GI Fittings and clamps including cutting and making good the walls etc .
1107Internal Work - Exposed on Wall
110832 mm dia nominal bore
110940 mm dia nominal bore
111050 mm dia nominal bore
1111Painting GI Pipes and Fittings with Synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work :
111232 mm diameter pipe
111340 mm diameter pipe
111450 mm diameter pipe
1115Providing and fixing multi-floor trap fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes heavy duty and sockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete in all respect as directed by Engineer-in-charge.
1116Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe complete in all respect as directed by Engineer-in-charge.
1117Providing and fixing CP Brass floor cleanout plug / Clean out plug as per drawing complete with G.I. Socket jointed to drainage pipe outlet including drip seal joint complete in all respect as directed by Engineer-in-charge.
1118100 mm diameter Pipe
1119150 mm diameter Pipe
1120Providing and fixing Stainless Steel Grade (304) grating with ring and Stainless steel anti cockroach basket and two SS screw including fixing to the floor with cement mortar.
1121SUB HEAD - III : INTERNAL WATER SUPPLY
1122Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc
112315 mm dia pipes
112420 mm dia pipes
112525 mm dia pipes
112632 mm dia pipes
112740 mm dia pipes
112850 mm dia pipes
1129Painting GI Pipes & Fittings with synthetic enamel white paint with two coats over a ready mixed priming coat , both of approved quality for new work .
113015 mm dia pipes
113120 mm dia pipes
113225 mm dia pipes
113332 mm dia pipes
113440 mm dia pipes
113550 mm dia pipes
1136Providing and Fixing GI Union in GI Pipe including cutting and threading the pipe and making long screws etc . Complete ( New Work )
113715 mm dia pipes
113820 mm dia pipes
113925 mm dia pipes
114032 mm dia pipes
114140 mm dia pipes
114250 mm dia pipes
114365 mm dia pipes
114480 mm dia pipes
1145Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makin good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.)
114615 mm dia pipes
114720 mm dia pipes
114825 mm dia .Pipes.
114932 mm dia .Pipes.
1150Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification.
11519 mm thick ( Pipe Inside the Toilets and Exposed in Shafts and Terrace )
1152For 15 mm dia Pipe
1153For 20 mm dia Pipe
1154For 25 mm dia Pipe
1155For 32 mm dia Pipe
1156For 40 mm dia Pipe
1157For 50 mm dia Pipe
1158Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in overhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 24 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc.
115940 mm dia Pipe
116050 mm dia Pipe
1161Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc.
116215 mm dia
116320 mm dia
116425 mm dia
116532 mm dia
116640 mm dia
116750 mm dia
1168INTERNAL ELECTRICAL WORK (PRINCIPAL RESIDENCE )
1169SUB HEAD - I: CIRCUIT CUM POINT WIRING
1170SWITCH CONTROL LIGHT POINTS
1171Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. .
1172Group A
1173Group B
1174Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
1175Group A
1176Group B
1177MCB CONTROL LIGHT POINTS
1178Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points)
1179Primary point controlled by one MCB.
1180Same as item above but Secondary point. i.e. Points to be looped with Primary point with 1.5 sqmm wire and Point wiring
1181Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
11822 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
11832 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
11842 X 4 sq. mm + 1 X 4 sq. mm earth wire
11852 X 6 sq. mm + 1 X 6 sq. mm earth wire
11862 x 10 sq. mm + 1 x 6 sq.mm earth wire
11874 X 10 sq. mm + 2 X 6 sq. mm earth wire
11884 X 16 sq. mm + 2 X 6 sq. mm earth wire
1189Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
1190Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
1191Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1192Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required. (AC's & Gysers)
1193Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1194Telephone socket outlet
1195TV antenna socket outlet
1196Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
11971 or 2 Module (75mmX75mm)
11986 module (78mm X 205 mm X 50 mm)
1199Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
12003 pin , 5/6 amps socket outlet
12015/6 amps switch
1202Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
120325 mm
120432 mm
1205SUBHEAD -II - FITTINGS & FIXTURES
1206Supply, Installation, Testing and Commissioning of 10 W Bulk head Light.
1207Supply, Installation, Testing and Commissioning of 5W Mirror Light.
1208Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
12098-10 Watt
121012-15 Watt
121118 Watt
1212Supplying, installation, Testing & Commissioning of LED (surface/wall) mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq. 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Batten light (System lumen efficacy >135 lm/Watt)
121318-22 Watt
1214Supply, Installation, Testing and Commissioning of 10W (Nominal) Wall Bracket Light
1215Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.
12161200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
1217Supply, installation, Testing and commissioning of 250mm Exhaust fan.
1218Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1219SUBHEAD - III - DISTRIBUTION BOARDS
1220Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12216 way, Double door
12228 way, Double door
122312 way, Double door
1224Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
12256 way (4 + 18), Double door
12268 way (4 + 24), Double door
1227Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1228Single Pole
1229Single Pole Neutral
1230Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1231Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1232Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1233Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1234SUB HEAD -IV - LT CABLES & CABLE TRAYS
1235Laying of one number PVC Insulated and PVC shethed /XLPE power Cables of 1.1 KV grade of following size direct in ground including excavation,sand cushioning and protecting covering and refilling the trench etc as required.
1236Up to 35 sq mm.
1237Above 35 sq mm and up to 95 sq mm.
1238Above 95 sq mm and up to 185 sq mm.
1239Laying of one number PVC insulated & PVC sheathed/ XLPE Power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
1240Upto 35 sq.mm
1241Above 35 sq. mm and upto 95 sq. mm
1242Above 95 sq.mm and upto 185 sq.mm
1243S/ F powder coated of approved shade MS Cable Trays
1244Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required..
1245100 mm width X 50 mm depth X 1.6 mm thickness
1246150 mm width X 50 mm depth X 1.6 mm thickness
1247300 mm width X 50 mm depth X 1.6 mm thickness
1248S/ F powder coated of approved shade MS Cable Tray Bends
1249Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray bends with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
1250100 mm width X 50 mm depth X 1.6 mm thickness
1251150 mm width X 50 mm depth X 1.6 mm thickness
1252S/ F powder coated of approved shade MS Cable Tray Tee's
1253Supplying and installing following size of perforated powder coated of approved shade M.S. cable tray tee's with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
1254100 mm width X 50 mm depth X 1.6 mm thickness
1255150 mm width X 50 mm depth X 1.6 mm thickness
1256Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
12574 X 10 sq. mm (28mm)
12584 X 16 sq. mm (28mm)
12593½ X 35 sq. mm (32mm)
12603½ X 50 sq. mm (35mm)
12613½ X 95 sq. mm (38mm)
12623½ X 120 sq. mm (38mm)
1263XLPE Insulated Copper Armoured Cables
12642C x 6 Sq.mm.
12652C x 4 Sq.mm.
12663C x 6 Sq.mm.
12673C x 4 Sq.mm.
12684CX 2.5 Sq.mm
12694C x 4 Sq.mm.
1270Supply and making End termination with brass Single/ Double compression gland including providing and crimping of aluminum/copper solderless lugs/ferrules for XLPE/PVC insulated armoured power aluminum/copper conductor cables 1.1 KV grade of following sizes:
1271SINGLE COMPRESSION GLAND FOR AI. AR. CABLE
12724C/3C x 6/4 sq.mm.
1273Single Compression Gland for Cu. Cable
12744C/3C/2C x 4/6/2.5 sq.mm.
1275Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required.
12764 X 10 sq. mm (25mm)
12774 X 16 sq. mm (28mm)
12783½ X 25 sq. mm (28mm)
12793½ X 35 sq. mm (32mm)
12803½ X 50 sq. mm (35mm)
12813½ X 95 sq. mm (45mm)
12823½ X 120 sq. mm (45mm)
1283SUB HEAD -V - EARTHING SYSTEM
1284Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1285Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
1286Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
1287Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
1288SUB HEAD - VI :LIGHTNING CONDUCTOR
1289Earthing with Cu. earth Plate 600mm x 600mm x 3mm thick including accesssories, and providing masonary enclosure with cover plate (CI heavy duty) having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.
1290Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
1291Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
1292Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
1293Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
1294Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
1295Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
1296Supply of Lightnig counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, meet the requirements for IS/IEC 62305 and IEC 62561-2.Tested for Electrical ,Mechanical and Chemical as per IEC 62561.
1297FOOTPATH 2.00 MT. WIDE
1298Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge
1299Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level.
13001:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)s)
1301Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
1302Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), ncluding making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
1303Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
1304Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
1305Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete.
1306Filling available excavated earth (excluding rock) in trenches, plinth, sides of oundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
1307Centering and shuttering including strutting, propping etc. and removal of form for all heights :
1308Foundations, footings, bases of columns, etc. for mass concrete.
1309BILL OF QUANTITIES FOR WATER SUPPLY
1310SUB HEAD (I) :- EXTERNAL WATER SUPPLY PIPES AND FITTINGS
1311DISTRIBUTION NETWORK FOR FRESH WATER SUPPLY
1312Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
1313External work
131420 mm dia nominal bore
131525 mm dia nominal bore
131632 mm dia nominal bore
131740 mm dia nominal bore
131850 mm dia nominal bore
131965 mm dia nominal bore
132080 mm dia nominal bore
1321Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
132220 mm diameter pipe
132325 mm diameter pipe
132432 mm diameter pipe
132540 mm diameter pipe
132650 mm diameter pipe
132765 mm diameter pipe
132880 mm diameter pipe
1329Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work.
133020mm dia nominal bore
133125mm dia nominal bore
133232mm dia nominal bore
133340mm dia nominal bore
133450 mm diameter pipe
133565 mm diameter pipe
133680 mm diameter pipe
1337Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :
133850 mm dia
133980 mm dia
1340Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
134120 mm nominal bore
134225 mm nominal bore
134332 mm nominal bore
134440 mm nominal bore
134550 mm nominal bore
134665 mm nominal bore
134780 mm nominal bore
13481:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1349Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work)
135025 mm nominal bore
135132 mm nominal bore
135240 mm nominal bore
135350 mm nominal bore
135465 mm nominal bore
135580 mm nominal bore
1356Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
1357LD- 2.5
1358Rectangular shape 600*450 mm internal dimensions
1359Constructing masonry gate valve Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
1360With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
1361Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
1362with common burnt clay F.P.S.(non module) brick of class designation 7.5
1363BILL OF QUANTITIES FOR SEWERAGE SYSTEM
1364SUB HEAD (I) :- EXTERNAL SEWERAGE SYSTEM
1365Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. anddisposing of surplus excavated soil as directed, within a lead of 50 m :
1366All kinds of soil
1367Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
1368Supply and fixing HDPE double I.S 16098 ( Part - 2 ) 3013 for soil / waste pipe under ground drainage system with jointed with rubber ring with good quality lubricant for fittings, inclusive of all necessary specials like bends, tees, offsets, junctions, re excavtion and refillig etc complete.
1369200 mm dia.pipe
1370250 mm dia. pipe
1371Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1372250 mm diameter Pipe (L*0.35*0.10=9.89)
1373250 mm diameter S.W. pipe (L*0.45*0.10=0.40)
1374Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard design
1375Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
1376With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5
1377Extra for depth for manholes:
1378size 90 X 80 cm
1379With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1380Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.
13810.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately)
1382with common burnt clay F.P.S.(non module) brick of class designation 7.5
1383Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m .
1384with common burnt clay F.P.S.(non module) brick of class designation 7.5
1385Providing and fixing square mouth S. W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
1386180 x 150 mm. size P type
1387With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1388Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
1389With 20 mm dia round bar
1390ANALYSIS OF RATE FOR SURFACE DRAIN (150X250 MM)
1391Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
1392Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1393Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level
13941:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1395Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stoneaggregate 12.5mm nominal size)
1396Centering and shuttering including strutting, propping etc. and removal of form for all heights :
1397Foundations, footings, bases of columns, etc. for mass concrete
1398Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in :
1399Cement mortar 1:6 (1 cement : 6 coarse sand)
140012 mm cement plaster finished with a floating coat of neat cement of mix :
14011:4 (1 cement: 4 fine sand)
1402ANALYSIS OF RATE FOR SEPTIC TANK ( 50 USER'S) 1 NOS.
1403Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
1404Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
1405Earth work in Excavation 1.50-3.00 mtr
1406Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
1407Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
14081:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
1409Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
1410Centering and shuttering including strutting, propping etc. and removal of form for:
1411Foundations, footings, bases of columns, etc. for mass concrete.
1412Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
1413Lintels, beams, plinth beams, girders, bressumers and cantilevers.
1414Suspended floors, roofs, landings, balconies and access platform.
1415Edges of slabs and breaks in floors and walls.
1416Under 20 cm wide
1417Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge.
1418Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
1419Thermo-Mechanically Treated bars.
14201:3 (1 cement: 3 fine sand)
14216 mm cement plaster on rough side of single or half brick wall of mix:
14221:3 (1 cement: 3 fine sand)
1423Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
1424HD-20
1425Circular shape 560 mm internal diameter
1426Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
1427Providing and fixing soil, waste and vent pipes
1428100 mm dia.
1429Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
1430Providing and fixing terminal guard :
1431Sand cast iron S&S as per IS - 3989
1432Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks
1433ESTIMATE OF EXTERNAL ELECTRICAL WORKS
1434SUBHEAD - I - MAIN BOARDS
1435Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 50 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below.
1436(Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maxmum fault level of the panel.)
1437FEEDER PILLAR
1438Design, Manufacturing, supplying, fixing in position, testing and commissioning of the following front operated front access 2mm thick CRCA steel enclosure free standing, water, dust and vermin proof outdoor type Feeder pillars with IP-55 protection hinged and lockable doors complete with interconnections copper crimping lugs, brass glands bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system . The panels fault withstanding capacity shall be of 25 MVA at 415 volts. All live accessories part shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be of colure coded with Heat shrinkable PVC insulated sleeves.
1439FEEDER PILLAR-1:
1440INCOMER
14411 No. 160A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit.
14421 No. Digital multifunction meter (V+A+Hz) with a set of cast resin CTs 160/5A.
14431 Set of Phase indicating lamp with MCB
1444BUS BARS-I :
1445200A TPN bus bars of aluminium alloy.
1446For emergency supply
14471 No. 63A, 415V, Ics=25kA, 4P MCCB with thermal magnetic trip unit.
14481 Set of On indicating lamp with MCB
1449BUS BARS-II :
1450100A TPN bus bars of aluminium alloy.
1451OUT GOING BUS-I :
14528 Nos. 63A 415V, 4P MCCB of 15kA .
14531 No. MCB Space.
1454OUT GOING BUS-II :
14555 Nos. 63A 415V, 4P MCB of 10kA .
14561 No. 40A 415V, 4P MCB of 10kA with 40A 4P Contactor & timer switch .
14572 Nos. 25A 415V, 4P MCB of 10kA .
14581 No. MCB Space.
1459METER BOARDS
1460Supply, installation, testing and commissioning of M.V. cubical type totally enclosed dust, dump and vermin proof Meter Bords complete with bus bars, MV danger notice plate, on surface ISI marked Electronic kWh meter, indication lamps, CT's, Interconnection with suitable capacity aluminium strips / rods, door covers, seperate compartment for each meter, glass inspection window, connection of incoming and outgoing cables with thimbles, powder coated having following incoming and outgoing MCBs MCCBs and kWh meters complete as required.
1461METER BOARDS
14621 No. 63A, 415V, Ics= 16kA, 4P MCCB with O/C, S/C protection & on indication lamp.
1463BUS BARS:
1464100A TPN bus bars of aluminium alloy.
1465OUT GOING:
14662 Nos. 40A DP MCB of 10kA with space for electronic direct kWh energy meter complete with all necessary wiring as per the Meter vendor requirement.
14677 Nos. 40A DP MCB of 10kA.
1468SUBHEAD - III - SUPPLYING & LAYING OF CABLE
1469L.T. CABLES
1470Supply of following sizes of XLPE insulated Aluminum conductor strip/ wire Armoured, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS-7098 Code and technical specifications.
14714 X 6 sq. mm
14724 X 10 sq. mm (28mm)
14734 X 16 sq. mm (28mm)
14743½ X 25 sq. mm (28mm)
14753½ X 35 sq. mm (32mm)
14763½ X 50 sq. mm (35mm)
14773½ X 150 sq. mm (50mm)
14783½ X 185 sq. mm (57mm)
14793½ X 240 sq. mm (62mm)
14803½ X 300 sq. mm (70mm)
1481Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
1482Upto 35 sq.mm
1483Above 35 sq. mm and upto 95 sq. mm
1484Above 95 sq.mm and upto 185 sq.mm
1485Above 185 sq.mm and upto 400 sq.mm
1486Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
14873½ X 25 sq. mm (28mm)
14883½ X 35 sq. mm (32mm)
14893½ X 50 sq. mm (35mm)
14903½ X 70 sq. mm (38mm)
14913½ X 95 sq. mm (45mm)
14923½ X 120 sq. mm (45mm)
14933½ X 150 sq. mm (50mm)
14943½ X 185 sq. mm (57mm)
14953½ X 240 sq. mm (62mm)
14963½ X 300 sq. mm (70mm)
14974 X 10 sq. mm (28mm)
14984 X 16 sq. mm (28mm)
1499Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
1500150 mm dia
1501300 mm dia
1502SUB HEAD -III : EARTHING SYSTEM
1503Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
1504Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
1505Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
1506Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
1507Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
1508Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56262894
AUTHORITY Government Departments
TENDER VALUE 4.46 Crore
LAST DATE 15-07-2026
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Tender for Conversion Of Sp Shed To Regular Staff Quarters Including Construction Of Shortfall Staff Quarters At Jnv Aurangabad (Bihar)
Basic Detail
Tender No 22/GM(T)/UPPCL/2026-27/DATE 01.07.2026
Bidding Type Tender
Location
City Aurangabad
State Bihar
Key Dates
Publish Date 02 Jul 2026
Submission Date 15 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 4.46 Crore
Tender Fee 17700
EMD 8.94 Lakhs
Exemption Not Available
Document List
BID.pdf
BOQ_2186469.xls
Tendernotice_1.pdf
3310f9c0-7576-4694-8338-d1868e6be6f4.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
pdf

BID.pdf

xls

BOQ_2186469.xls

pdf

Tendernotice_1.pdf

html

3310f9c0-7576-4694-8338-d1868e6be6f4.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders