Bids Are invited for Operation And Maintenance Of Electrical Systems/Electrical Installations - Miscellaneous Works For Operation And Maintenance Of Electrical Systems In Various Facilities Of Frd Barc Trombay Mumbai 400085 - Electrical System: Preve
Tender Overview
Project Description
Bids Are invited for Operation And Maintenance Of Electrical Systems/Electrical Installations - Miscellaneous Works For Operation And Maintenance Of Electrical Systems In Various Facilities Of Frd Barc Trombay Mumbai 400085 - Electrical System: Preventive And Breakdown Maintenance Of Electrical Systems Of Various Plants Consists Of Class-Iv Panels, Transformers , 300Ah Battery Banks, Lt Switchgear Panels With 3000A/1250A/ 1000A Acbs, 100A Sfus (In General Shift) , Preventive Maintenance Of Class Iv Panel , Preventive Maintenance Of Class Iii Panel , Preventive Maintenance Of Apfc Panel , Preventive Maintenance Of Station Battery Bank , Preventive Maintenance Of Lighting & Plug Circuit Panel , Preventive Maintenance Of Dol/Star-Delta Starters From 7.5 Kw To 22 Kw Rating , Preventive Maintenance Of Dol/Star-Delta Starters From 37.5 Kw To 60 Kw Rating , Preventive Maintenance Of Dol/Star-Delta Starters From 75 Kw To 132 Kw Rating , Providing Power Supply For Various Electrical Equipment Like Flood Lights, 3-Phase Welding Machine Etc. As Per Requirement. , Cleaning, Servicing, Repair & Maintenance Of Normal And Emergency Mcb-Dbs, Integrity & Tightness Checking Of Terminals / Connections, Checking Of Insulation Healthiness At Terminations, Checking Of Mechanical Movement Of Switch Action-Rod, U -Cl S, Push Buttons Checking Of Earth Connections Etc. At Various Areas Of Plant , Attending Breakdown Maintenance Of Lighting Fixtures At Various Plants Involving Removal Of Defective Lighting Fixture, Checking For Possible Faults, Replacement Of Defective Components And Installation & Testing Of Fixtures , Assisting In Maintenance And Motor Overhauling, Cable Laying Etc. Consists Of Providing Tools And Materials Required For The Job, Cleaning And Removal Of Scrap And Waste Generated During The Work , Cleaning, Servicing, Repair & Maintenance Of Mccs At Various Plants Consists Of Cleaning Of Panel Integrity & Tightness Checking Of Terminals / Connections, Checking Of Insulation Healthiness At Terminations, Checking Of Mechanical Movement Of Switch Action-Rod, U -Cl S, Push Buttons, Checking Of Earthing Etc. , Maintenance Of Earth Pits And Measurement & Logging Of Earth Resistance. , Maintenance Of Electrical System In Round The Clock (Rtc) Shifts , Assisting In Operation, Surveillance And Maintenance Of Major Electrical Equipment In Round The Clock Shift At Sub-Station In Reprocessing Plant Including Preventive Maintenance And Breakdown Maintenance Of Electrical Equipment Including Sub-Station Lt Switchgear And Transformers On Round The Clock Shift Basis, Monitoring & Recording Of Voltages, Currents, P.F. Etc. Of Various Feeders, Temperature Of Operating Motors & Starters, Maintenance Of 2X300ah Battery Banks, Attending Breakdown Maintenance Of Lt Switchgear Panel Consisting 3 Nos 3000 A Acb , 4 Nos 1250A Acb, 5 Nos 1000 Acb , 20 Nos Sfu 100A, 300A , Breakdown Maintenance Of Starters From 5 Hp To 180 Hp 3 Nos, Connection Of 3-Phase Welding Machine , Providing Flood Light Connections, Attending Tube Light Fixtures Etc.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Electrical System: Preventive and breakdown maintenance of electrical systems of various plants consists of Class-IV panels, Transformers , 300AH battery banks, LT switchgear panels with 3000A/1250A/ 1000A ACBs, 100A SFUs (in general shift) | Electrical System: Preventive and breakdown maintenance of electrical systems of various plants consists of Class-IV panels, Transformers , 300AH battery banks, LT switchgear panels with 3000A/1250A/ 1000A ACBs, 100A SFUs (in general shift) |
| 2 | Preventive maintenance of class IV panel | Preventive maintenance of class IV panel |
| 3 | Preventive maintenance of class III panel | Preventive maintenance of class III panel |
| 4 | Preventive maintenance of APFC panel | Preventive maintenance of APFC panel |
| 5 | Preventive maintenance of Station Battery Bank | Preventive maintenance of Station Battery Bank |
| 6 | Preventive maintenance of Lighting & Plug circuit panel | Preventive maintenance of Lighting & Plug circuit panel |
| 7 | Preventive maintenance of DOL/Star-delta starters from 7.5 KW to 22 KW rating | Preventive maintenance of DOL/Star-delta starters from 7.5 KW to 22 KW rating |
| 8 | Preventive maintenance of DOL/Star-delta starters from 37.5 KW to 60 KW rating | Preventive maintenance of DOL/Star-delta starters from 37.5 KW to 60 KW rating |
| 9 | Preventive maintenance of DOL/Star-delta starters from 75 KW to 132 KW rating | Preventive maintenance of DOL/Star-delta starters from 75 KW to 132 KW rating |
| 10 | Providing power supply for various electrical equipment like flood lights, 3-phase welding machine etc. as per requirement. | Providing power supply for various electrical equipment like flood lights, 3-phase welding machine etc. as per requirement. |
| 11 | Cleaning, servicing, repair & maintenance of normal and emergency MCB-DBs, Integrity & tightness checking of terminals / connections, checking of insulation healthiness at terminations, checking of mechanical movement of switch action-rod, U -Clamps, push buttons checking of earth connections etc. at various areas of plant | Cleaning, servicing, repair & maintenance of normal and emergency MCB-DBs, Integrity & tightness checking of terminals / connections, checking of insulation healthiness at terminations, checking of mechanical movement of switch action-rod, U -Clamps, push buttons checking of earth connections etc. at various areas of plant |
| 12 | Attending breakdown maintenance of lighting fixtures at various plants involving removal of defective lighting fixture, checking for possible faults, replacement of defective components and installation & testing of fixtures | Attending breakdown maintenance of lighting fixtures at various plants involving removal of defective lighting fixture, checking for possible faults, replacement of defective components and installation & testing of fixtures |
| 13 | Assisting in maintenance and motor overhauling, Cable laying etc. consists of providing tools and materials required for the job, cleaning and removal of scrap and waste generated during the work | Assisting in maintenance and motor overhauling, Cable laying etc. consists of providing tools and materials required for the job, cleaning and removal of scrap and waste generated during the work |
| 14 | Cleaning, Servicing, Repair & maintenance of MCCs at various plants consists of cleaning of panel Integrity & tightness checking of terminals / connections, checking of insulation healthiness at terminations, checking of mechanical movement of switch action-rod, U -Clamps, push buttons, checking of earthing etc. | Cleaning, Servicing, Repair & maintenance of MCCs at various plants consists of cleaning of panel Integrity & tightness checking of terminals / connections, checking of insulation healthiness at terminations, checking of mechanical movement of switch action-rod, U -Clamps, push buttons, checking of earthing etc. |
| 15 | Maintenance of earth pits and measurement & logging of earth resistance. | Maintenance of earth pits and measurement & logging of earth resistance. |
| 16 | Maintenance of Electrical System in Round The Clock (RTC) shifts | Maintenance of Electrical System in Round The Clock (RTC) shifts |
| 17 | Assisting in operation, surveillance and maintenance of major electrical equipment in round the clock shift at sub-station in Reprocessing Plant including preventive maintenance and breakdown maintenance of electrical equipment including Sub-station LT switchgear and transformers on round the clock shift basis, monitoring & recording of voltages, currents, P.f. etc. of various feeders, temperature of operating motors & starters, maintenance of 2x300AH battery banks, attending breakdown maintenance of LT switchgear panel consisting 3 Nos 3000 A ACB , 4 Nos 1250A ACB, 5 Nos 1000 ACB , 20 Nos SFU 100A, 300A , breakdown maintenance of Starters from 5 hp to 180 HP 3 Nos, connection of 3-phase welding machine , providing flood light connections, attending tube light fixtures etc. | Assisting in operation, surveillance and maintenance of major electrical equipment in round the clock shift at sub-station in Reprocessing Plant including preventive maintenance and breakdown maintenance of electrical equipment including Sub-station LT switchgear and transformers on round the clock shift basis, monitoring & recording of voltages, currents, P.f. etc. of various feeders, temperature of operating motors & starters, maintenance of 2x300AH battery banks, attending breakdown maintenance of LT switchgear panel consisting 3 Nos 3000 A ACB , 4 Nos 1250A ACB, 5 Nos 1000 ACB , 20 Nos SFU 100A, 300A , breakdown maintenance of Starters from 5 hp to 180 HP 3 Nos, connection of 3-phase welding machine , providing flood light connections, attending tube light fixtures etc. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender