Tender For Repairs To Mcb Db, Submain Wring, Energy Meter Service Ca-Ble Of Various Accn Under Ge Danapur Cantt
Tender Value
25 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
18 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patna → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To Mcb Db, Submain Wring, Energy Meter Service Ca-Ble Of Various Accn Under Ge Danapur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium power/sub main wiring of any size / type all as specified and directed. |
| 2 | M & L for power/sub main wiring with two runs of single core 4 sqmm size and one run of single core 4.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note - two runs of 4 sqmm single core copper conductor and one runs of 4.0 Sqmm copper conductor & PVC conduit shall be measured as one unit length. |
| 3 | M & L for power/sub main wiring with two runs of single core 6 sqmm size and one run of single core 6.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note : two runs of 6 sqmm single core copper conductor and one runs of 6.0 Sqmm copper conductor and PVC conduit shall be measured as one unit length. |
| 4 | M & L for power/sub main wiring with two runs of single core 10 sqmm size and one run of single core 10.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note : two runs of 10 sqmm single core copper conductor and one runs of 10.0 Sqmm copper conductor & PVC conduit shall be measured as one unit length. |
| 5 | M & L for power/sub main wiring with four runs of single core 10 sqmm size and one run of single core 10.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note : Four run of 10 sqmm single core copper conductor and one runs of 10.0 Sqmm copper conductor & PVC conduit shall be measured as one unit length. |
| 6 | Taking down old U/S MCCB/MCB DB of any type, make complete all as specified and directed. |
| 7 | Supply & Fixing sheet metal enclouser MCCB DB IP 43 protection double door bus bar neutral link earth bar and din rail VTPN 4 way suitable for MCCB upto 125A, FP as incomer and 12 Nos SP MCBs / 4 Nos TP MCB as outgoing complete all as specified and directed. |
| 8 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail TPN 4 way. |
| 9 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 12 way. |
| 10 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 8 way. |
| 11 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 4 way. |
| 12 | Taking down old U/S MCCB / MCB of any type,make complete all as specified and directed. |
| 13 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,100 Amps with breaking capacity 16 KA fixed type all as specified and directed. |
| 14 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,125 Amps with breaking capacity 16 KA fixed type all as specified and directed. |
| 15 | Supply & Fixing MCB TPN 16 to 32 Amps 415 volts, 10 KA \\"C\\" curve. |
| 16 | Supply & Fixing MCB TPN 40 to 63 Amps 415 volts, 10 KA \\"C\\" curve. |
| 17 | Supply & Fixing MCB SPN 32 Amps 240 volts, 10 KA, \\"C\\" curve. |
| 18 | Supply & Fixing MCB SPN 40 to 63 Amps 240 volts, 10 KA, \\"C\\" curve. |
| 19 | Supply & Fixing MCB SP 5 to 32 Amps 240 volts, 10 KA, \\"C\\" curve. |
| 20 | Taking down existing single/three phase energy meter of any type and make from existing position and repair existing surfaces with same material and old meters deposited to MES store yard with last reading of meters complete all as speciied and directed. |
| 21 | Supply and fixing single phase electronic kWh meter (energy meter) temper proof with LCD display 5-30A with optical port & polycarbonate cover box , 230V, accuracy class-I, 50 Hz, confirming to IS 13779, IP 54 with parameters to show data, time, current reading,load, PF, voltage and KWH complete all as specified and directed. |
| 22 | Supply and fixing single phase electronic kWh meter (energy meter) temper proof with LCD display 10-60A with optical port & polycarbonate cover box , 230V, accuracy class-I, 50 Hz, confirming to IS 13779, IP 54 with parameters to show data, time, current reading,load, PF, voltage and KWH complete all as specified and directed. |
| 23 | Supply and fixing three phase 4 wire kWh meter (energy meter) with LCD display 10-60A , 415V,working on direct metering system accuracy class-I, 50 Hz, confirming to IS 13779, IP 54 with parameters to show data, time, current reading,load, PF, voltage and KWH complete all as specified and directed. |
| 24 | Taking down the existing defective LT UG cable from trenches / pipes / pole for fault finding / replacement, all as specified and directed of any size between 10 Sq mm to 35 Sq mm 2 core /3.5 core/4 Core. Note : Excavation and earth work will be measured and paid seperately under relevant items. |
| 25 | Supply, laying, jointing and testing XLPE insulated extruded PVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed of size 10 Sqmm 2 core. |
| 26 | Same as item No 25 above but size 16 sqmm 4 core. |
| 27 | Same as item No 25 above but size 25 sqmm 4 core. |
| 28 | Same as item No 25 above but size 35 sqmm 3.5 core. |
| 29 | Excavation in trenches n.exc. 1.5 m wide and n.exc.1.5 m deep in any type of soil and forming bottom surfaces for laying of cable complete all as specified and directed. |
| 30 | Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditected. Note: Punned down thickness of sand shall be measured for payment purposes. |
| 31 | Supply & laying bricks for protection of cable sub class 'B' laid dry flat across the cable with width equal to the length of whole bricks complete all as specified and ditected. |
| 32 | Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed. |
| 33 | Removal of surplus soil to a distance n. exc. 50 m and deposited where diredted at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed. |
| 34 | Boring, holes for inserting of 40/50 mm bore GI pipe under the road/hard standing or any other location not less than 1200 mm deeep complete all as specified and ditected. |
| 35 | M & L GI pipe 40 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 36 | M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 37 | M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.50 m below GL) connected with GI earth wire 4Sq mm as earthing leads by means of bolts, nuts, check nuts and washers properly jointed as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender