Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56261064

Tender For Repair/Replacement And Rewinding Of Ceiling Fan,Exhaust Fan, Wall Mounted Fan Including Repair To Geyser And Solar Water Heater Etc Under The Aor Of Ge (Mh&Rh) Khadki.

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Jul 2026
17 days left
EMD
400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement And Rewinding Of Ceiling Fan,Exhaust Fan, Wall Mounted Fan Including Repair To Geyser And Solar Water Heater Etc Under The Aor Of Ge (Mh&Rh) Khadki.

BOQ

Name of Work:- Repair/Replacement and rewinding of ceiling fan,exhaust fan, wall mounted fan including repair to Geyser and solar water heater etc under the AOR of GE (MH&RH) Khadki.
Sl. No. Item Description
1Taking down old unserviceable Ceiling /Exhaust/Air circulator fans of any type from any height and Material and labour for rewinding of Ceiling Fan, Exhaust Fan and Air circulator fan of any type/make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire of appropriate gauge including connection,capacitor base and testing complete all as specified and directed for following. Note: (a) Bearing ,fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
2Ceiling fan of 1200/1400 mm sweep, complete all as specified and directed
3Exhaust Fan of sweep 275 to 300 mm, complete all as specified and directed
4Exhaust Fan of sweep 350 to 450 mm, complete all as specified and directed
5Air circulator of sweep 350 to 450 mm, complete all as specified and directed
6Supply only ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed Make: SKF/NBC
7Supply only ball bearing suitable for 275/450 mm exhaust fan complete all as specified and directed Make : SKF/NBC
8Supply only fan capacitor of following capacity , complete all as specified and directed
9capacitor 2.5 mfd , complete all as specified and directed
10capacitor 4 mfd , complete all as specified and directed
11Supply and fix in repair Ceiling fan 1200mm sweep white colour complete with fan blades, and accessories, 230 V. Min air delivery 220 CMM with ISI marked, complete all as specified and directed.MAKE:- Halonix/ Polycab/ Havells/USHA/Philips
12Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and depositing old ceiling fan to MES store complete all as specified and directed.Make : USHA/Halonix/Philips/Havells/Polycab .
13Supply and fix in repair Wall mounting fan of size 400mm sweep, double string, copper wounded, AC single Phase. 230V heavy duty with air delivery 65CMM, silent operation complete all as specified and directed.
14Supply only , rubber yoke, MS Clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and directed
15Supply only gunmetal bush suitable size for ceiling fan 1200 /1400 mm sweep complete all as specified and directed
16Supply only fan down rod of following length with white enamel painted with both side hole for hanging fan of sweep 1200/1400mm complete all as specified and directed
171 ft long
182 ft long
19Supply only stator for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting rotor size complete all as specified and directed
20Supply only rotor for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting stator size complete all as specified and directed
21Supply only fan canopy set of off white /white coloured as per colour of ceiling fan of sweep1200/1400mm complete all as specified and directed
22Material and labour in repairs /re-fixing on exiting or new location storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under against Ser Nos (a) to (f) at different locations (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank (b) Examine water tightness of storage tank after cleaning.(c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) Supply and fix in repair rubber / PVC gasket to ensure water tightness. (e) Checking of safety valve (f) Testing of geysers after repairs.
23Supply and fix in repairs thermal cutout ISI marked temp range 50 to 80/90 degree as required at site for geyser of capacity 25/35/50 Ltr of any make complete all as specified and directed
24Supply and fix in repairs safety valve/high pressure valve ISI marked as per site requirement complete all as specified and directed
25Supply and fix in repairs heating element of following rating as required at site including rubber washers complete all as specified and directed
261/1.5 KW,240 volt
2702 KW ,240 volt
28Supply and fix in repairs PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection complete all as specified and directed
29Supply and fix in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection complete all as specified and directed
30Supply and fix in repairs, non return valve 15 mm dia of brass, ISI marked complete all as specified and directed
31Supply and fix in repair stop valve , cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore complete all as specified and directed
32Material and labour for repairing and replacment of unserviceable copper container of capacity 25/50 Ltrs of solar water heater of any type after completion of work testing the heater complete all as specified and directed
33Copper container 50/100 Ltr of water heater (geyser) , complete all as specified and directed
34Copper container capacity 25 Ltrs of water heater (geyser) , complete all as specified and directed
35Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items shall be made as per condition laid down under schedule of credit seprately ) and making good disturbed surfaces of walls, floors etc complete all as specified and directed
36Material and labour for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and sheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally , covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Make: Polycab /Finolex/ Plaza
37One fan/light /bell point controlled by one switch/bell push, complete all as specified and directed
38One switch socket outlet 5 Amps on independent board , complete all as specified and directed
39One socket outlet 5 Amps on the same board , complete all as specified and directed
40All as per Item No 24 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but sheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board complete all as specified and directed
41All as per Item No 24 here-in-before but with 4.0 Sqmm PVC insulated multistranded copper conductor cable including 4.0 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board complete all as specified and directed
42Material and labour for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into and including PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size complete all as specified and directedNote: Two single core cable, earth wire and PVC conduit shall be measured as one length.
43All as per item no 27 above but of 6 Sqmm, complete all as specified and directed
44Supply and fix in repair ceiling rose surface bakelite with three terminals type in complete all as specified and directed.
45Supply and fix in repairs switch piano type one way 6 Amps flush type ,240volt AC complete all as specified and directed.
46Supply and fix in repairs socket outlet 2 in1,3 pin 5 Amps complete all as specified and directed.
47Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3 pin, 5 Amps flush type ,240volt AC complete all as specified and directed.
48Supply and fix in repairs switch piano type 16 Amps flush type ,240volt AC complete all as specified and directed.
49Supply and fix in repairs socket outlet 2 in 1, 3/ 5 pin 16 Amps flush type complete all as specified and directed.
50Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3/5 pin, 16 Amps flush type ,240volt AC complete all as specified and directed.
51Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed.
52Supply and fix in repair modular switch 2 way 6A 1 module complete all as specified and directed.
53Supply and fix in repair modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
54Supply and fix in repair modular socket 6A /16A 2/3 pin combined 2 module complete all as specified and directed.
55Supply and fix in repair modular fan regulator,120 watt - 2 module complete all as specified and directed.
56Supply and fix in repair stepped type electronic fan regulator 120 watt ,240 olt flush type on the existing phenolic laminated sheet complete all as specified and directed.
57Supply and fix in repair electric bell Ding Dong, AC 230 volts complete all as specified and directed.
58Supply and fix in repair Modular white cover plate with frame of following size complete all as specified and directed.
591 module
602 module
613 module
624 module
636 module
648 module
65Supply and fix in repair industrial wall mounted plug socket suitable for IP 44 degree of protection of 32Amps rating 2P+E complete all as specified and directed. Make: L&T/Indoasian/Legrand/C&S
66Supply and fix in repair wall mounted extruded aluminium housing high quality indoor batten of following capacity colour temperature 6500 K (4' long) lumen 2000 to 3000, PF> 0.9, THD less 15% diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement complete all as specified and directed Make : Havells/wipro/Halonix
67LED tube light fitting of 22 watt, 4 Ft long, complete all as specified and directed
68LED tube light fitting of 10watt, 2 Ft long, complete all as specified and directed
69Supply and fix in repair wall/ceiling mounted Inverter LED tube light fitting 4' feets long with opal diffuser and having aluminium body. Energy efficient high quality invertor batten should have Lithium ion battery of 3.7V, 19 WH having inbuilt battery backup upto 2Hrs with high power brightness having BIS certification, LED fitting should be LM 80 certified with system efficacy greater than 100 lumens/watt, including LED tube 20/22 watt having colour temperature 6500 K , PF> 0.95, THD less 10%, with IP20 protection having open and short circuit protection, having input voltage range 90V to 300V connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement complete all as specified and directed Make : Havells/Jaquar/Halonix/Crompton .
70Material and labour in repair for PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed
71100 x 100 mm and 50 mm deep, complete all as specified and directed
72200 x 150 x 50 mm deep , complete all as specified and directed
73250 x 200 x 50 mm deep , complete all as specified and directed
74150 x 150x 50 mm deep, complete all as specified and directed
75Servecing of Solar water heater of capacity upto 200 LPD by disconnecting hot and cold water connection, taking out old and defective spares such as rubber washers, gate valves 20/25 mm dia , NRVs , heating elements, rusted pipes etc, and draining out the water from tank, cleaning/descaling of the inner storage tank , headers and connected pipe lines and cleaning the solar glass tubes and replacing the old rubber seals/gaskets/nipples from the system , and making proper connections and fixing new gaskits and washers and tightning of valves and pipe line (GI/CPVC) and making system fully functional including cleaning and painting the mounting brackets and MS structure complete all as apecified and as directed. Note :- The work is to be carried out in roofs of the OTM and Md Accns.(ii) The rates are inclusives of rubber gaskits, washers etc(iii) Safety valves , NRV, gate valves, heating elements etc will be measured and paid separately under relevant item of schedule.
76Decarbonizing of indoor MCB DB's / Meter box panel and distribution panel of bldgs by dismantling the old MCCB's, old Bus bars , cable connections, old Amps meter and old voltmeter and cleaning the panel with ctc solvent, and removing the old/burnt control wiring, replacing the old/burnt bus bar of any size and fixing properly the hanging/loose front and rear opening doors of the panels, by welding of hinges including welding of broken MS sheet using extra sheets of required size also replacing burnt thimbles with new existing size thimbles, indicator lamps, including powder coating painting of panel with suitable 'U' type gasket to make it dust and vermin proof, providing fancy locks including dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed
77Material and labour in repair for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to 4.0 mm dia galvanized earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 (20 mm graded stone aggregate) RCC cover, 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire of suitable size and length for continuity earth wire from test point to main distribution Board complete all as specified and directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed to be included in item unit rate. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56261064
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 23-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement And Rewinding Of Ceiling Fan,Exhaust Fan, Wall Mounted Fan Including Repair To Geyser And Solar Water Heater Etc Under The Aor Of Ge (Mh&Rh) Khadki.
Basic Detail
Tender No 8888/E8
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 02 Jul 2026
Submission Date 23 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 400
Exemption Not Available
Document List
71613246-d69b-43a7-a42e-d91f6e9c8ee7.html
BOQ_868818.xls
TENDER.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

71613246-d69b-43a7-a42e-d91f6e9c8ee7.html

xls

BOQ_868818.xls

pdf

TENDER.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders