Tender For Special Repair Of Otm Bldg No P-142 Under Ge (W) Hisar At Hisar Mil Stn
Tender Value
37.86 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
12 days left
EMD
75800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair Of Otm Bldg No P-142 Under Ge (W) Hisar At Hisar Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of RCC Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and making good the disturbed area in CM 1:3 complete all as specified and directed. |
| 2 | S&F Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. within 20mm of the length indicated), for cooler stand, chajjas with all necessary fittings complete all as specified and directed. |
| 3 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall and in chajjas, fixed with self tapping screws complete all as specified and directed. |
| 4 | S&F superior quality SS Curtain rod, 20mm dia with and including SS bracket 2 Nos for each opening and fancy type SS side knob of required shape and size 2 Nos of each opening as approved by Engr- in charge and complete all as specified and directed. |
| 5 | S&F in repair Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) of 150mm length and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 6 | S&F of hollow PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 7 | Taking down chowkhats or frame n exc 1.50 Sqm each with shutters (Without taking off shutters from the frames) complete all as specified and directed. |
| 8 | Steel windows with side hung/openable shutters including projecting/box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed. |
| 9 | Steel windows with side hung shutters/openable including projecting/box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded all as specified and directed. |
| 10 | S&F galvanised steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm complete all as specified and directed. |
| 11 | S&F in repairs galvanised steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm complete all as specified and directed. |
| 12 | S&F, 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 13 | S&F framed work such as grills, gratings etc with ends of bars shouldered and riveted, framed guard bars ,barred iron doors,ladder,framed work for water tank and similar work confirming to fe 290-0, E-165 complete all as specified and directed. |
| 14 | M & L two coat of synthetic enamel (ordinary tint) over one coat of red oxide or zinc chromate primer,including prepration of surface on new steel surface of any description over 10 cm width or girth not other wise described complete all as specified and directed. |
| 15 | Taking down PVC Chowkhats or frames not exc. 1.5 sq. m each carefully and refixing in the same opening complete all as specified and directed. |
| 16 | Taking down PVC Chowkhats or frames not exc. 1.5 sq. m each carefully complete all as specified and directed. |
| 17 | Taking down Chowkhats or frames (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed. |
| 18 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 19 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame with all necessary fittings like 03 Hinges,02 tower bolt,02 handles per each shutter at site as per specification & drawing complete all as specified and directed. |
| 20 | S&F made single extruded WPC (Wood Polymer composite)) Solid door/ window/clerestory windows & other Frames/ chowkhat of size 65x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade) calcium carboante and natural fibers (Wood powder/roce hisk/wheat husk) and non toxic additives (maximum toxicity index of 12 of 100 gms)fabricated with miter joints after applying PVC Solvent cement and screwed with full body threaded star headed SS screwes having minimum frame density of 750 Kg/cim screw withdrawal strength of 2200 N (Face) & 1100 N (Edge) minimum compressive strength of 58 N/mm2 modules of elasticty 900 N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof, water/ moisyure proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasterners of required dia and length complete all as specified and directed. |
| 21 | Factory made single extruded WPC (Wood Polymer Composite) Solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (suspensio Grade) calcium carbonate and natural fibers (Wood powder/rice husk/wheat husk) and non toxicity additive (maximum toxicity index of12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Eage) minimum compressive strength 50 N/mm2 modulus of elastcity 850 N/mm2 and reistance to spread of flame of class A category with property of being termite/borer proof, water /moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, with all necessary fittings 03 Hinges,02 Tower bolt of 150mm and 01 handle 150mm for each shutter, complete all as specified and directed. |
| 22 | M&L for Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and including 10mm backing coat of cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, including dismantling existing stone, complete all as specified and directed. |
| 23 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, including backing coat in 10mm thick CM (1:3) to receive Kota Stone, including dismantling existing stone, complete all as specified and directed. |
| 24 | Mirror polishing of existing marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed. |
| 25 | M&L for Coloured Non-skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes of CM 1:6, including dismantling existing tiles, complete all as specified and directed. |
| 26 | M&L for coloured Glazed ceramic tiles in vertical surface 300x 450x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including backing coat of 10mm thick of CM 1:4, including dismantling existing tiles, complete all as specified and directed. |
| 27 | M&L for treatment of sunken floor slab comprising of the following specifications with and including demolition of PCC in sunken portion/ floors including removal of the debris outside the MOD land and complete all as specified and directed:-(i) Demolition of PCC in sunken portion /floors and Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including S& f in repair 40 mm dia, 450 mm long medium grade spout pipe and cutting holes in bricks or RCC wall for the same . (ii) Rendering of uneven surfaces at bottom and sides up to floor level with 15 mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out. (iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in Fosroc / Thremax as approved by GE. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or or equivalent make in Fosroc / Thremax as approved by GE in two coats @ 3kg/sqm to sanwiched with glass fibre reinforcemnt: Sika Fab-1 or or equivalent make in Fosroc / Thremax as approved by GE over base coat as per mnaufacturer's instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion. (viii) The sunken floor shall be filled with lean concrete 1:5:10, type E2(40 mm graded aggregate)Note :-Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all M&L is include in the rates quoted above. only Plan area will be Measured. |
| 28 | M&L Cement concrete in foundations, filling and mass concrete, Type B2 1:2:4(20mm graded aggregte), complete all as specified and directed. |
| 29 | Providing Type C0 1:3:6 (12.5mm graded aggregate) precast cement concrete louvres and jallies, 25mm thick (measured solid), including all mouldings and frame complete all as specified and directed. |
| 30 | S&F in Repair PVC Floor trap 75mm bore with grating including jointing using solvent cement to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed. |
| 31 | S&F,110mm dia PVC SWR or Rain water pipe of single socketed with rubber joint, jointed with solvent joint fixed to wall/ floor, including taking down existing pipe with all fittings, complete all as specified & directed. |
| 32 | S&F,110mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 33 | S&F,110mm dia PVC (SWR) junction double, (Double T) equal or unequal complete all as specified and directed. |
| 34 | S&F of 110mm PVC (SWR) vent cowl complete all as specified and directed. |
| 35 | S&F PVC (SWR) bends 110 mm bore with/without access door any radius complete all as specified and directed. |
| 36 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls/ floor, including taking down existing pipe with all fittings, complete all as specified and directed. |
| 37 | S&F PVC (SWR) bends 75mm bore with/without access door any radius complete all as specified and directed. |
| 38 | S&F, 75mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 39 | S&F, 75mm dia PVC (SWR) junction double, (Double T) equal or unequal complete all as specified and directed. |
| 40 | S&F of 75mm PVC (SWR) vent cowl complete all as specified and directed. |
| 41 | Taking up or down 15mm bore steel / composite / UPVC tubing and connection from any position concealed / exposed including cleaning for refixing or removal to store complete all as specified and directed. |
| 42 | Supplying and laying of CPVC pipes class-1 (SDR 11) , 20 mm Nominal size & fittings in wall/ceiling complete all as specified and directed. |
| 43 | Supplying and laying of CPVC pipes class-1 (SDR 11) , 25 mm Nominal size & fittings in wall/ceiling complete all as specified and directed. |
| 44 | S&F Brass Elbow for special fitting of 20 mm Nominal size CPVC pipe complete all as specified and directed. |
| 45 | S&F Brass Elbow for special fitting of 25 mm Nominal size CPVC pipe complete all as specified and directed. |
| 46 | S&F Brass Tee for special fitting of 20 mm Nominal size CPVC pipe complete all as specified and directed. |
| 47 | S&F Brass Tee for special fitting of 25 mm Nominal size CPVC pipe complete all as specified and directed. |
| 48 | Rendering 15mm thick Cement plaster 1:4 on fair faces of brick work or concrete surfaces, trowelled to even and smooth finish w/o using extra cement, including taking down existing plaster, complete all as specified and directed. |
| 49 | M&L for Preparation of New plastered surface of wall and Finishing walls with Acrylic Smooth exterior paint of required shade, Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm, complete all as specified and directed. |
| 50 | Rendering 10mm thick Cement plaster 1:6 on fair faces of brick work or concrete surfaces, trowelled to even and smooth finish w/o using extra cement, including taking down existing plaster, complete all as specified and directed. |
| 51 | M & L two coat of oil bound distemper over Priming plastered and other surfaces with alkali-resistant priming paint on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed. |
| 52 | Rendering 5 mm thick on ceiling surfaces in CM(1:3) finished even and smooth with out using extra cement, including taking down existing plaster, complete all as specified and directed. |
| 53 | M& L for preparation of New surfaces of Ceiling and applying Two coat of white wash complete all as specified and directed |
| 54 | M&L for complete removal of existing treatment of wall and Finishing walls with Acrylic Smooth exterior paint of required shade ,Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm, complete all as specified and directed. |
| 55 | M & L one coat of oil bound distemper on old plastered surfaces of walls including preparation of surfaces complete all as specified and directed. |
| 56 | M& L for preparation of old surfaces of Ceiling and applying one coat of white wash complete all as specified and directed |
| 57 | Dismantling of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 58 | M&L for Brickwork built in CM 1:6 with old size subclass `B' bricks, straight or curved on plan exc 6m mean radius complete all as specified and directed. |
| 59 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including pedastal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc complete and Seat and cover for pedestal pan all as specified and directed. |
| 60 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed. |
| 61 | S&F in repair vitreous China, squatting pan, Orissa Pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with PTMT trap of suitable size (P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of cement concrete bedding & making good to floor complete all as specified and directed including taking out old one. |
| 62 | S&F in repairs 10 Litre capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required complete all as specified and directed. |
| 63 | S&F in repair Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 64 | S&F CP soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 65 | S&F in repair brass chromium plated over head shower rose fitted to steel pipe or union complete all as specified and directed. |
| 66 | S&F in repair corner glass shelf 300mm (with brass brackets) along with CP railing complete all as specified and directed. |
| 67 | S&F in repair brass chromium plated tubular Towel Rack 600mm Long with Lower Hangers, Stainless Steel complete all as specified and directed. |
| 68 | S&F in repair Rotational moulded polyethylene water storage tank, white 1000 ltr capacity, three layer (cylindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed. |
| 69 | S&F Ball valves, high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball, screwed for iron pipe or brass ferrule 20mm bore complete all as specified and directed. |
| 70 | S&F 20mm bore dia nipple suitable for HDPE water tank (Min weight 15mm-38 gms/20mm-45gms/25mm-65gms) fixed complete all as specified and directed. |
| 71 | S&F in repair gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 20mm bore pipe complete all as specified and directed. |
| 72 | S&F in repair Wall Mixer 3-in-1 System with 115 mm Bend Pipe & Aerator complete all as specified and directed. |
| 73 | S&F in repair 15 mm bib tap (fancy type), cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 74 | S&F in repair 15 mm dia Stop valves / angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 75 | S&F SS, premium type, peg set 6. heavy weight complete all as specified and directed. |
| 76 | S&F in repair 600 x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 77 | Dismantling of Brick tiles or terracing tiles, single layer on roofs and removing complete all as specified and directed. |
| 78 | Demolition of Mud in roofs, any thickness,including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed. |
| 79 | M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate in padding, levelling course and the like finish even and fair 50mm avg. thickness including preparation of RCC roof surface(old or new) with wire brush, drying and cleaning top surface to remove all loose particles, filling the cracks with crack filler complete all as specifie and directed. |
| 80 | M&L for Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces,rendering is to be finished even and smooth (without using extra lime or cement). |
| 81 | Supply only liquid water proofing compound complete all as specified and directed. |
| 82 | M&L for Bitumen primer for use in waterproofing and damp-proofing treatments complete all as specified and directed. |
| 83 | Supplying & Laying of five layered 3mm thick APP (Atactic Polypropylene) modified prefabricated bituminous waterproofing Memberane , reinforced with glass fibre matt treatment and upperside of memberane thermally insulated with white mineral gravel finish, uniformly embedded during manufacturing process shall be laid dry torch application, side coverlaps shall be 75 mm and end slab shall be 100 mm and all over laps and joints shall also be sealed by torch application complete all as specified and directed. |
| 84 | M & L for 75mm thick cement concrete type C – 1 (1:3:6) using 20mm graded stone aggregate as in plinth protection and PCC paved area, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 85 | Cutting into existing manholes for connecting new drains,100mm bore and less making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed. |
| 86 | Taking down carefully copper/ Aluminium point wiring ( light, fans, socket, power socket) complete including taking out existing unserviceable terminal boxes and conduit with swithces/sockets/fan regulators and fittings such as ceiling roses, pendants, tube lights fittings lamp holders, brackets light fittings, rectangular blocks DB MCCB etc and making good disturbed surface of wall/ floor etc to match with the existing the surface etc complete all as specified and directed. |
| 87 | Material and labour for point wiring with 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/ fan/bell point in existing PVC rigid non metallic concealed conduit 19/20 mm dia medium duty, ISI marked to be terminated & including pressed modular steel boxes & cover plate of module as required on site including 1.5 sqmm (22/.3mm) PVC insulated and unsheathed FRLS single core multisrtaned copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per exisitng treatment complete all as specified and directed. |
| 88 | Description all as per item No 87.00 (here-in-before) but One three pin 5 Amp socket outlet point on independent board controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 89 | Description all as per item No 87.00 (here-in-before) but One three pin 5 Amp socket outlet point on same board controlled by one nos, one way switch on same board complete all as specified and directed. |
| 90 | Description all as per item No 87.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on independent board complete all as specified and directed. |
| 91 | S&F Modular switch 1 way 6A 1 module Single pole, one way, 230 volts complete all as specified and directed. |
| 92 | S&F Modular switch 1 way 16A 1 module complete all as specified and directed. |
| 93 | S&F Modular socket 6A -2/3 pin combined 2 module type 230 volts AC complete all as specified and directed. |
| 94 | S&F Modular socket 6A/16A -2/3 pin combined 2 module type 230 Volts, AC complete all as specified and directed. |
| 95 | S&F Modular lamp holder, insulated body with back plate including LED Bulb of 9 watt suitable for batten fittings complete all as specified and directed |
| 96 | S&F Modular ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed |
| 97 | Supply & fixing Modular type (1/2 module as per site requirement) ceiling fan regulator electronic step type suitable for 1200mm/1400mm sweep fan complete all as specified and directed |
| 98 | S&F LED light fitting 1x20watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any crack. The fitting should have following technical specification complete all as specified and directed :- (i) surge protection of minimum 2 KV (ii) power factor should be more than 0.90 (iii) cool white colour, (iv) total hormonic distoration (THD) should not be more than 15% (v) lumen output should not be less than 1700 lumens, (vi) can withstand with input voltage range 140-280V AC, (vii) colour rendering index should not be less than 80, (viii) Corelated colour should be minimum 6000 degree Kelvin (ix) Minimum warranty period of 2 Years. |
| 99 | S&F Sheet metal enclosure distribution board SP&N,8 way, double door powder coated, protection class IP-42 suitable for mounting MCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar complete all as specified and directed. |
| 100 | Supply and fixing MCBs SP 6 to 32Amps, 240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note : Make of the MCB should be the same as that of DB |
| 101 | Supply and fixing MCBs SPN 32Amps to 63 Amps, 240 volts, 10 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note : Make of the MCB should be the same as that of DB |
| 102 | S&F Sheet metal enclosure distribution board VTPN,4 way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCCB as incoming and MCB's as outgoing in DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with PCC works complete all as specified and directed. |
| 103 | Supply and fixing MCCBs FP 63 Amps, 415 volts, 16 KA rupturing capacity, IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed. Note : Make of the MCCB should be the same as that of DB |
| 104 | Taking down carefully copper/aluminium Submain wiring from battan /conduit from DBs, MCBs, etc) and making good to disturbed surfaces of walls, floor etc complete all as specified and directed. |
| 105 | M & L for submain wiring alongwith earth wire with the 2x6.0 sq. mm +1x6.0 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required, complete all as specified and directed. Note :- A run of single core cables and specified runs of earth continuity conductors shall be measured as one run length. |
| 106 | Supply & Fixing Exhaust Fan iron body with louvers and accessories 230 V 450 MM sweep heavy duty with blades & copper winding with service value complete all as specified and directed |
| 107 | Supply and Fixing electric water heater storage type steel body with copper inner tank and heating element upto 3 KW capacity 50 Ltr BEE 5 Star ( Energy efficient) rated complete with all accessories such as safety valve, Thermostats, NRV, Stainless steel hot and cold connection pipe etc complete all as specified and directed. |
| 108 | Refixing of existing or new ceiling fan of any sweep including dismantling from existing position, checking of connections, reconnetion of wiring, providing proper insulation, tightening of nut and bolts, levelling/alignment and refix the fan at location complete all as specified and directed |
| 109 | Supply & fixing in replacement of Bldg security light fitting LED 30 W, pressure die cast housing epoxy powder coating IP -65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed with MS Calmps of size 40x5 mm- 02 nos ,nuts, bolts and washers on wall complete all as specified and directed. |
| 110 | M&L for Earthing complete with galvanised mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole or wall with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth pit to top of earth plate electrode including all excavation and earth work in any type of soil and removal of soil upto 10 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as specified and directed.NOTES : (i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.00 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order(iii) Items includes cost of 7.5 metre earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer