Tender For Additional / Alteration Of Drainage System In Jadunath Vihar Under Age B/R -I Of Ge Jaipur At Jaipur Mil Stn
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Jul 2026
17 days left
EMD
48720
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Additional / Alteration Of Drainage System In Jadunath Vihar Under Age B/R -I Of Ge Jaipur At Jaipur Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavation over areas n exc 1.5m deep and getting in soft/loose soil complete all as specified and as directed. |
| 3 | ,---ditto--- all as per item No. 2 above but depth exc 1.5m but not exc 3m complete all as specified and directed. |
| 4 | M&L PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in as in foundations, filling and mass concrete complete all as specified and directed. |
| 5 | Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat with fair finished surfaces of concrete complete all as specified. |
| 6 | Use & waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter flat with fair finished surfaces of concrete complete all as specified. |
| 7 | Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, n exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed. |
| 8 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide for fair finished surfaces all as specified and directed. |
| 9 | M & L for RCC M-30 (Design Mix) (using 20mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete complete all as specified and as directedNote : Reinforcement & formwork shall be measured and paid for separately. |
| 10 | M & L for RCC M-30 (Design Mix) (using 20mm graded stone aggregate) as in slab supported on walls , beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.Note : Reinforcement & formwork shall be measured and paid for separately. |
| 11 | M&L for RCC M-30 (Design Mix) (using 20 mm graded stone aggregateas) as in walls, retaining walls, basement walls, ballast walls and the like, any thickness above top of footings including attached pilasters and buttresses complete all as specified and as directed.Note : Reinforcement & formwork shall be measured and paid for separately. |
| 12 | M&L Mild steel TMT bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed and specified. |
| 13 | ,--- ditto--- all as per srl item No. 12 above but TMT bar of 6 to 8mm dia complete all as directed and specified. |
| 14 | M&L hardcore of Broken stones or Boulders of gauge n. exc 63 mm, deposited spread and levelled in layers n exc 15 cm thick watered and rolled /rammed to a true surface complete all as specified and as directed. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil complete all as specified and as directed. |
| 16 | Removing excavated material to a distance n. exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed. |
| 17 | M&L for filling with broken stone / boulders gravel of gauge 3 to 10mm, deposited, spread and levelled in layers n exc 15cm thick to a true surface complete all as specified and as directed. |
| 18 | M&L sand filling with graded course sand under floors or in foundations including watering, spreading and levelling in layers n exc 25 mm thick complete all as specified and as directed. |
| 19 | M & L for rendering 10mm thick in CM 1:6 on fair faces of brick masonary or concrete surface, finished even and smooth w/o using extra cement incl mixing of water proofing compund as per manufacturers instructions complete all as specified and directed.Note : WPC shall be measured and paid seperately |
| 20 | S&F 20 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or laid in floor complete all as specified and directed. |
| 21 | S&F 150 mm bore PVC (SWR) pipes (conforming to IS-13592) single socketed in any length with rubber ring joints inserted in RWH pit including necessary fittings complete all as specified & directed. |
| 22 | S&F 150mm bore HDPE strainer / perforated pipes single socketed in any length with rubber ring joints inserted in RWH pit including necessary fittings complete all as specified & directed. |
| 23 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints inserted in RWH pit including necessary fittings complete all as specified & directed. |
| 24 | S&F 110mm bore HDPE strainer / perforated pipes single socketed in any length with rubber ring joints inserted in RWH pit including necessary fittings complete all as specified & directed. |
| 25 | S&F 110mm bore HDPE / PVC bends without oval access doors complete all as specified and directed |
| 26 | S&F 150mm bore PVC (SWR) / HDPE strainer cover plate complete all as specified and directed. |
| 27 | M&L pre-cast reinforced cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in pre-cast cover slab / GT cover slab / manhole cover slab of any thickness, size or shape including all necessary form work, finishing concrete surface fair & even and set in CM 1:4 complete all as specified and directed.Note : Reinforcement shall be measured and paid for separately. |
| 28 | S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways;drainage crossings, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed |
| 29 | M&L for boring hole 150 mm dia nominal bore in rain water harvesting pit in any type of strata for PVC / HDPE up to 150 mm nominal bore pipe up to 100 meter depth complete all as specified and directed. |
| 30 | M&L preparation of new steel surface of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 31 | M&L for loose filling of broken stone aggregate / pea gravel of gauge n. exc. 3.60 mm complete all as specified and directed. |
| 32 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth, for foundation etc or for shafts, wells, manholes, pier holes, laying of cables etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 33 | M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 34 | Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 35 | M&L for brick work with sub-class 'B' bricks (old size), straight or curved on plan exc 6m mean radius built in In cement mortar 1:6 but except bricks incl cleaning of bricks complete all as specified and directed.Note : Old bricks obtained from demolition will be used under this item. |
| 36 | M&L for brick work with sub-class 'B' bricks (using old size bricks ), straight or curved on plan exc 6m mean radius built in In cement mortar 1:6 complete all as specified and directed |
| 37 | M & L for rendering 15mm thick in CM 1:4 on fair faces of brick masonary or concrete surface, finished even and smooth w/o using extra cement incl mixing of water proofing compund as per manufacturers instructions complete all as specified and directed.Note : WPC shall be measured and paid seperately |
| 38 | Supply only integral water proofing compund ISI marked complete all as specified and directed. |
| 39 | M&L PCC 1:3:6 type C-2 (using 20mm graded stone aggregate) as in surface channels and drains and benching including finishing the top of benching even and smooth with using extra cement complete all as specified and directed. |
| 40 | M&L providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintel up to 1.5 mtr clear span, cills, steps, seismic and other similar bands, plinth course, string course, lacing course, parapets and railing up to 60cm in height, coping, kneelers, apex stones, bed plates kerb, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 41 | M&L mild steel framed work as in drainage covers or doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe 290 (Gde- E- 165) complete all as specified and directed. Please Enable Macros to View BoQ information |
| 42 | M&L mild steel framed work as in drainage covers or doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete Fe 290 (Gde- E- 165) complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender