BOQ
| Sl. No. | Item Description |
| 1 | RENOVATION |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCnsulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 5 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 7 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 4 sqmm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 11 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 13 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 14 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 15 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 16 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 17 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) |
| 18 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 100 A, 16KA |
| 19 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 20 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 21 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 22 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 23 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 24 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 25 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 26 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 27 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 28 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 10 sq mm |
| 29 | Removal of old lights and fans including transportation,labour etc complete |
| 30 | Supply and fixing of SQUARE/ROUND -36 W 2' X 2' LED panel lights on celling where ever designed by electrical engineers with copper coloured wire with green earth wire so as to share the connected load and equal distribution of lights bands for standard candle power and keeping distance. including cost and conveyance of all materials labour charge etc. complete |
| 31 | Supply and fixing of 20W LED tube light complete with all accessories for wall/ ceiling mounting, including cost and conveyance of all materials labour charge etc . Complete |
| 32 | Supply and installing of 400mm sweep wall fan neatly and safely or fixing with anchor fastener and making good the all after fitting etc complete. including cost and conveyance of all materials labour charges etc. complete |
| 33 | Preparing as-built drawing and shop drawing and charges for taking approval and getting electrical connection from CEI and KSEB (Testing fees -As per actual on submitting original receipt) |
| 34 | AIR CONDITIONING WORK |
| 35 | 4 TON 3 phase 5 STAR CASSETTE AC Providing and supplying BRANDED DAIKIN 4 TON 5 star inverter type cassette AC at the site. Rate inclusive of transportation charge, loading charge etc all complete |
| 36 | Supplying and fixing decorative panel for round flow cassette, Complete |
| 37 | Providing and supplying sensor kit for cassette AC |
| 38 | ADDITIONAL DRAINAGE PIPING FOR AIR CONDITIONERS Supplying and fixing additional drainage piping for both split and cassette AC as per the site conditions |
| 39 | ADDITIONAL COPPER PIPING FOR AIR CONDITIONERS Supplying and fixing additional copper piping for both split and cassette AC as per the site conditions |
| 40 | Supply and charging of refrigerant gas for cassette AC units by topping up the existing system after checking for leakage, including necessary servicing, testing, and commissioning, complete. |
| 41 | Supplying and fixing communication cable for air conditioners as per the site conditions, including transportation, fixing charge all inclusive |
| 42 | Air conditioner stand Providing and fixing wall mounted steel stand for ODU unit. transportation, fixing charge all inclusive. |
| 43 | AIR CONDITIONING INSTALLATION WORK (for Cassette AC) Providing Air conditioning installation work. Transportation, fixing charges all inclusive |
| 44 | Core cutting existing RCC slab or masonry walls to provide openings in these structures without causing any damages to the structure. ( 75mm dia round hole, 12cm depth ) |
| 45 | CCTV WORK |
| 46 | Supply and fixing of 4MP Network IR Dome having 1/2.9” 4MP PS CMOS Image Sensor (0.8758 centimeters), Max. 4MP (2688 × 1520)@1-25/30fps/ (2560 × 1440)@1-25/30, Instastream, H.265, H.264, H.264H, H.264B, MJPEG, Support Triple stream, WDR (120dB), Day/Night(ICR), 3D NR, AWB, AGC, BLC, HLC, Digital watermarking, 3.6mm fixed Lens, Support Built-in Mic. Make: CP PLUS/ PRAMA |
| 47 | Supply and fixing NVR 16 channel having 16 Ch. 4K 2HDDs Network Video Recorder, Up to 16 channel IP camera input, Max. decoding capability: 8 × 1080p@30 fps, 2 × 8 MP@30 fps Smart Instastream/H.265/H.264 /MJPEG, Up to 12Mp resolution preview and playback, Max.160/160/80 Mbps incoming/recording/outgoing bandwidth, Support 2 SATA HDDs up to 20TB, 2 (1 front USB 2.0 port, 1 rear USB 2.0 port), HDMI / VGA simultaneous video output, Support Multi-brand network cameras, ONVIF Version 2.4 conformance, Mobile Software: iCMOB, gCMOB, CMS Software: KVMS, KVMS Pro |
| 48 | Supply and fixing of Monitor ACER/AOC -22'' LED, HDMI Input |
| 49 | Supply and fixing of Monitor accessories LAN TO HDMI ,LAN TO USB. |
| 50 | Supply and fixing of 4 U Wall mount rack including all other accessories |
| 51 | Supply and fixing of HARD DISK CGATE/ WD - 6 TB, HEAVY DUTY, SATA [PURPLE HARD DISK |
| 52 | Supply and fixing of RJ45 Connector |
| 53 | Supply, Installation, Testing and Commissioning of 16+2 -Port Gigabit L2 Managed Non PoE Switch. With 2 year warranty including configurations , load balancing etc or any other configurations as instructed at the time of installation. Preferred Make: CP PLUS |
| 54 | CCTV Installation Work |
| 55 | ACCESS CONTROL SYSTEM |
| 56 | Supply, installation, testing and commissioning of Ultra thin fingerprint time attendance & access control system with fingerprint exit reader for flush door, having Fingerprint Capacity 3,000, Card C apacity : 5,000, Display : 2.8-inch TFT Screen, Keypad : Yes, LED Indicator Green/Red, DST, 2.4 inch TFT color screen and Touch keys, Ultra thin and elegant design, Full Access Control Features: Anti-passback, access control interface for 3rd party electric lock, door sensor, exit button, alarm, Standard Wi-Fi, Network interface by TCP/IP or RS485, Multiple Verificaon Modes: M ulti-verification methods (card is oponal) providing user various choices, including EM lock, U bracket etc complete |
| 57 | UPS & BATTERY |
| 58 | Supply , Installation , testing and commissioning of Numeric -legrand Premius RT 10 kVA FM ups 3ph: 1ph with 240vdc(1Ph input&1Ph output) IGBT based online double conversion pure sine wave UPS system and accessories with rack and Interconnecting cables and deliveryincluded. 3yr warrant |
| 59 | Supply, installation, testing and commissioning of 12V x 20 no’s 42Ah Exide SMF make SMF batteries for with 3yr warranty.@ 30mins backup |
| 60 | Supply , Installation , testing and commissioning of Numeric -legrand Onfiniti Plus 3 kVA FM ups 1ph: 1ph with 72vdc(1Ph input&1Ph output) IGBT based online double conversion pure sine wave UPS system and accessories with 3yr warranty |
| 61 | Supply , Installation , testing and commissioning of 12V x 6 nos 42Ah Exide SMF make SMF batteries for with 2yr warranty.@ 30mins backup |
| 62 | INTERIOR WORK |
| 63 | Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below |
| 64 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) |
| 65 | Providing & fixing toughened glass partition upto ceiling height, with support to concrete slabs/roofings using 12mm thick toughened glass with box type plywood border at top and bottom. Consisting of 19mm thick marine grade IS 710 BWP plywood at top and bottom for framework, fixed to floor, walls and ceiling at a spacing of 45cm centre to centre horizontally and vertically, using metal/wooden support dash fastner, anchor fasteners or metal screws with nylon plugs , studs etc. Fix 12 mm thick toughened glazing as per the architect drawing. Fix 9mm thick IS 710 BWP plywood on both sides of framewok at top and bottom of the partition. Both surface to be finished with 1mm thick mica of approved make and color at exposed surfaces, including providing openings for windows, glass, doors, electrical wiring etc complete as per design. |
| 66 | Providing and fixing frameless single shutter toughened glass door as per design of size 90 cm wide and 210 cm height/as per drawing. Thickness 12 mm. Fittings to be provided stainless steel make floor spring of 90 kg weight capacity, patches for door top and bottom, making holes. Stainless-steel double-sided door handle of 200 mm length. Glass to glass double-sided stainless-steel door lock to fixed. Complete as per design and size and direction of engineer in-charge |
| 67 | Providing single shutter partially glazed/opaque flush door as per design of size 210 cm height/as per drawing. Thickness 30 mm. 30mm thick door ply to be fixed.Exposed Surface to be finished with 1 mm thick decorative laminate of approved make and colour. Hinges, latches, mortice lock, auto closer to be provided as per design and size and direction of engineer incharge.NC putty to be neatly applied on exposed surfaces. |
| 68 | Providing and fixing wall paneling in any design upto ceiling height consisting of 19mm thick marine grade IS 710 BWP plywood framework sections, fixed to floor, walls and ceiling at the spacing of 45cm centre to centre horizontally and vertically using necessary wooden/metal support, dash fastener, anchor fastener or metal screws with nylon plugs and studs. 9mm thick marine grade IS 710 BWP plywood to be fixed on exposed surface. Surface to be finished with 1 mm thick decorative laminate of approved make and colour. Including providing openings for glass, window, doors, designs, groves etc. complete as per design. Including all cost to finish work at site |
| 69 | 1.007 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1:2011 (Board with BIS certification marks)False ceiling |
| 70 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 71 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 72 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 73 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |
| 74 | Providing and fixing etched/frosted self-adhesive sticker film on existing glass surfaces, including surface preparation, cutting, alignment, application, finishing, and all labour, materials, wastage complete as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender