Heavy Industries and Public Enterprises Boards / Undertakings / PSU Closing in 3 days TDR #56259667

Tender For General Interior And Renovation Work

Issued by Boards / Undertakings / PSU · Kannur, Kerala
Tender Value
27.37 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
3 days left
EMD
54749
Bank guarantee accepted
Document Fee
5474
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kannur → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For General Interior And Renovation Work

BOQ

Name of Work:- General Interior and Renovation Work
Sl. No. Item Description
1RENOVATION
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCnsulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
4Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
5Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
7Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
8Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 4 sqmm
9Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
10Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
13Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
14Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
15Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
16Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
17Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
18Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 100 A, 16KA
19Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
20Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
21Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
22Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
23Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
24Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
25Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
26Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
27Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
28Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 10 sq mm
29Removal of old lights and fans including transportation,labour etc complete
30Supply and fixing of SQUARE/ROUND -36 W 2' X 2' LED panel lights on celling where ever designed by electrical engineers with copper coloured wire with green earth wire so as to share the connected load and equal distribution of lights bands for standard candle power and keeping distance. including cost and conveyance of all materials labour charge etc. complete
31Supply and fixing of 20W LED tube light complete with all accessories for wall/ ceiling mounting, including cost and conveyance of all materials labour charge etc . Complete
32Supply and installing of 400mm sweep wall fan neatly and safely or fixing with anchor fastener and making good the all after fitting etc complete. including cost and conveyance of all materials labour charges etc. complete
33Preparing as-built drawing and shop drawing and charges for taking approval and getting electrical connection from CEI and KSEB (Testing fees -As per actual on submitting original receipt)
34AIR CONDITIONING WORK
354 TON 3 phase 5 STAR CASSETTE AC Providing and supplying BRANDED DAIKIN 4 TON 5 star inverter type cassette AC at the site. Rate inclusive of transportation charge, loading charge etc all complete
36Supplying and fixing decorative panel for round flow cassette, Complete
37Providing and supplying sensor kit for cassette AC
38ADDITIONAL DRAINAGE PIPING FOR AIR CONDITIONERS Supplying and fixing additional drainage piping for both split and cassette AC as per the site conditions
39ADDITIONAL COPPER PIPING FOR AIR CONDITIONERS Supplying and fixing additional copper piping for both split and cassette AC as per the site conditions
40Supply and charging of refrigerant gas for cassette AC units by topping up the existing system after checking for leakage, including necessary servicing, testing, and commissioning, complete.
41Supplying and fixing communication cable for air conditioners as per the site conditions, including transportation, fixing charge all inclusive
42Air conditioner stand Providing and fixing wall mounted steel stand for ODU unit. transportation, fixing charge all inclusive.
43AIR CONDITIONING INSTALLATION WORK (for Cassette AC) Providing Air conditioning installation work. Transportation, fixing charges all inclusive
44Core cutting existing RCC slab or masonry walls to provide openings in these structures without causing any damages to the structure. ( 75mm dia round hole, 12cm depth )
45CCTV WORK
46Supply and fixing of 4MP Network IR Dome having 1/2.9” 4MP PS CMOS Image Sensor (0.8758 centimeters), Max. 4MP (2688 × 1520)@1-25/30fps/ (2560 × 1440)@1-25/30, Instastream, H.265, H.264, H.264H, H.264B, MJPEG, Support Triple stream, WDR (120dB), Day/Night(ICR), 3D NR, AWB, AGC, BLC, HLC, Digital watermarking, 3.6mm fixed Lens, Support Built-in Mic. Make: CP PLUS/ PRAMA
47Supply and fixing NVR 16 channel having 16 Ch. 4K 2HDDs Network Video Recorder, Up to 16 channel IP camera input, Max. decoding capability: 8 × 1080p@30 fps, 2 × 8 MP@30 fps Smart Instastream/H.265/H.264 /MJPEG, Up to 12Mp resolution preview and playback, Max.160/160/80 Mbps incoming/recording/outgoing bandwidth, Support 2 SATA HDDs up to 20TB, 2 (1 front USB 2.0 port, 1 rear USB 2.0 port), HDMI / VGA simultaneous video output, Support Multi-brand network cameras, ONVIF Version 2.4 conformance, Mobile Software: iCMOB, gCMOB, CMS Software: KVMS, KVMS Pro
48Supply and fixing of Monitor ACER/AOC -22'' LED, HDMI Input
49Supply and fixing of Monitor accessories LAN TO HDMI ,LAN TO USB.
50Supply and fixing of 4 U Wall mount rack including all other accessories
51Supply and fixing of HARD DISK CGATE/ WD - 6 TB, HEAVY DUTY, SATA [PURPLE HARD DISK
52Supply and fixing of RJ45 Connector
53Supply, Installation, Testing and Commissioning of 16+2 -Port Gigabit L2 Managed Non PoE Switch. With 2 year warranty including configurations , load balancing etc or any other configurations as instructed at the time of installation. Preferred Make: CP PLUS
54CCTV Installation Work
55ACCESS CONTROL SYSTEM
56Supply, installation, testing and commissioning of Ultra thin fingerprint time attendance & access control system with fingerprint exit reader for flush door, having Fingerprint Capacity 3,000, Card C apacity : 5,000, Display : 2.8-inch TFT Screen, Keypad : Yes, LED Indicator Green/Red, DST, 2.4 inch TFT color screen and Touch keys, Ultra thin and elegant design, Full Access Control Features: Anti-passback, access control interface for 3rd party electric lock, door sensor, exit button, alarm, Standard Wi-Fi, Network interface by TCP/IP or RS485, Multiple Verificaon Modes: M ulti-verification methods (card is oponal) providing user various choices, including EM lock, U bracket etc complete
57UPS & BATTERY
58Supply , Installation , testing and commissioning of Numeric -legrand Premius RT 10 kVA FM ups 3ph: 1ph with 240vdc(1Ph input&1Ph output) IGBT based online double conversion pure sine wave UPS system and accessories with rack and Interconnecting cables and deliveryincluded. 3yr warrant
59Supply, installation, testing and commissioning of 12V x 20 no’s 42Ah Exide SMF make SMF batteries for with 3yr warranty.@ 30mins backup
60Supply , Installation , testing and commissioning of Numeric -legrand Onfiniti Plus 3 kVA FM ups 1ph: 1ph with 72vdc(1Ph input&1Ph output) IGBT based online double conversion pure sine wave UPS system and accessories with 3yr warranty
61Supply , Installation , testing and commissioning of 12V x 6 nos 42Ah Exide SMF make SMF batteries for with 2yr warranty.@ 30mins backup
62INTERIOR WORK
63Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
64Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
65Providing & fixing toughened glass partition upto ceiling height, with support to concrete slabs/roofings using 12mm thick toughened glass with box type plywood border at top and bottom. Consisting of 19mm thick marine grade IS 710 BWP plywood at top and bottom for framework, fixed to floor, walls and ceiling at a spacing of 45cm centre to centre horizontally and vertically, using metal/wooden support dash fastner, anchor fasteners or metal screws with nylon plugs , studs etc. Fix 12 mm thick toughened glazing as per the architect drawing. Fix 9mm thick IS 710 BWP plywood on both sides of framewok at top and bottom of the partition. Both surface to be finished with 1mm thick mica of approved make and color at exposed surfaces, including providing openings for windows, glass, doors, electrical wiring etc complete as per design.
66Providing and fixing frameless single shutter toughened glass door as per design of size 90 cm wide and 210 cm height/as per drawing. Thickness 12 mm. Fittings to be provided stainless steel make floor spring of 90 kg weight capacity, patches for door top and bottom, making holes. Stainless-steel double-sided door handle of 200 mm length. Glass to glass double-sided stainless-steel door lock to fixed. Complete as per design and size and direction of engineer in-charge
67Providing single shutter partially glazed/opaque flush door as per design of size 210 cm height/as per drawing. Thickness 30 mm. 30mm thick door ply to be fixed.Exposed Surface to be finished with 1 mm thick decorative laminate of approved make and colour. Hinges, latches, mortice lock, auto closer to be provided as per design and size and direction of engineer incharge.NC putty to be neatly applied on exposed surfaces.
68Providing and fixing wall paneling in any design upto ceiling height consisting of 19mm thick marine grade IS 710 BWP plywood framework sections, fixed to floor, walls and ceiling at the spacing of 45cm centre to centre horizontally and vertically using necessary wooden/metal support, dash fastener, anchor fastener or metal screws with nylon plugs and studs. 9mm thick marine grade IS 710 BWP plywood to be fixed on exposed surface. Surface to be finished with 1 mm thick decorative laminate of approved make and colour. Including providing openings for glass, window, doors, designs, groves etc. complete as per design. Including all cost to finish work at site
691.007 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1:2011 (Board with BIS certification marks)False ceiling
70Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
71Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
72Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
73Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
74Providing and fixing etched/frosted self-adhesive sticker film on existing glass surfaces, including surface preparation, cutting, alignment, application, finishing, and all labour, materials, wastage complete as directed by the Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56259667
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 27.37 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name kerala artisans development corporation ltd
Work Description Tender For General Interior And Renovation Work
Basic Detail
Tender No KADCO/DDO/211/2026-27/KNR-002
Bidding Type Tender
Location
City Kannur
State Kerala
Key Dates
Publish Date 01 Jul 2026
Submission Date 14 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 27.37 Lakhs
Tender Fee 5474
EMD 54749
Exemption Available
Document List
7a5e072a-8157-4a2a-a48e-08a596121d75.html
BOQ_1450975.xls
NIT.pdf
TenderDocument2.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

7a5e072a-8157-4a2a-a48e-08a596121d75.html

xls

BOQ_1450975.xls

pdf

NIT.pdf

pdf

TenderDocument2.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender