Tender For Construction Work Of Marriage Procession Near Ambedkar Statue In Gram Sabha Situhiya Pokharbhinda.
Tender Value
11.96 Lakhs
Estimated cost
Bid Submission
07 Jul 2026
4 days left
EMD
24000
Bank guarantee accepted
Document Fee
752
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kushi Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Work Of Marriage Procession Near Ambedkar Statue In Gram Sabha Situhiya Pokharbhinda.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (D.S.R 2.8.1) |
| 2 | Providin of Laying in position cement concrete of specified grade 14:8 (1 Cement 4 coarse sand (zone-III) derived. from natural sources graded stone aggregate 40 mm nominal size derived from natural sources) (DS.R 4 1.8) |
| 3 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level 1:15:3 (1 cement 15 coarse sand (zone 3 graded stone III) derived from natural sources aggregate 20 mm nominal size derived from natural sources) (D S.R 5.1.2 |
| 4 | Same as above in item No 3 but for beam, roofs, lintel band & etc above plinth level. 1:15:3 (1 cement 1.5 coarse sand (zone-III) derived from natural sources 3 graded stone aggregate 20 mm nominal size derived from natural sources) (D.SR.5.3 |
| 5 | Same as above in item No 4 but for Column as per 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DS.R.5.2.2 |
| 6 | Steel Reinforcement for R.C.C work including cutting,straightening bending binding and placing in position & including complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. (D.S.R.5.22.6 |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in 6 coarse sand) Cement mortar 1:6 (1 cement (DSR.6 1.2 |
| 8 | Same as above in item No 7 but in super structure for wall of one brick thickness Brick work with common burnt clayl FPS (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1.6 (1 cement: B coarse sand) (D.SR.6.4) |
| 9 | 12 mm thick plaster with 1.6 cement and coarse sand morter on brick work including ranking and joint washing and cleaning and including supply of all materials labour and T&P etc. required for proper completion of work. (DSR 13.4.2) |
| 10 | Same as above in item No 9 but for plaster on rough facel (DSR 13 5.2) |
| 11 | Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift :All kinds of soil(D.S.R.2.2.1) |
| 12 | Supplying and filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. (D.S.R.2.27) |
| 13 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (D.S.R.10.25.1) |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS 2202 (Part 1) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws (D.S.R.9.21.1) |
| 15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.. complete. Size of Tile 600x600 mm As per D.S.R 11 41.2) |
| 16 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (D.S.R. 13.47.1) |
| 17 | Distempering with 1st quality acrylic distemper, (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (D.S.R.13.41.1) |
| 18 | Finishing with Deluxe Multi Surface Paint for interiarior or exterior using primer as per manufactures specification. Painting wood work with deluxe multi Multi Surface Paint required shade to or more coat applied @ 0.90 Itr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (D.S.R.13.48.2) |
| 19 | Supply and fixing of sign board including supply and cost of all materils labours T & P etc. required templet as directed by the Engineer In charge. |
| 20 | Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper onductor single core cablein surface recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. DSR NO. 1.10 |
| 21 | Wiring for light/ power plug with 2X4 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper |
| 22 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required DSR NO 1.14 |
| 23 | 2 X 1.5 sq. mm + 1X 1.5 sq mm earth wire DSR NO. 1.14.1 |
| 24 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR NO. 1. 14.2 |
| 25 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. DSR NO. 1.24 |
| 26 | 5/6 A switch DSR NO. 1.24.1 |
| 27 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular piate switch box including connections but excluding modular plate etc, as required. DSR NO. 1.25 |
| 28 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 15 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc as required. DSR NO. 1.45 |
| 29 | Supplying and fixing following way, Horizontal type three pole and neutral MCIB distribution board, 415 volts on surface/recess complete with, tinned copper busbar, neutral busbar, carth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators). DSR NO. 2.4.1 |
| 30 | Brush Less Direct Current (BLDC) F-an with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (B1 DC) Motor, class of insulation: 13, 3 nos, metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos, canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), 1111) (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 OC (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Ilz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/cexternal connections with 1.5 sq.mm FRI S/HEER, PVC insulated copper conductor single core cable and carthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) DSR NO. 9.1.3 |
| 31 | GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender