Tender For special Repair To Drainage System Behind Bldg No P-10 To P-06 And Change Of Damaged Wiring 10Mm Copper Wire And Flexible Cable At Dinjan Mil Stn
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Jul 2026
10 days left
EMD
66800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Drainage System Behind Bldg No P-10 To P-06 And Change Of Damaged Wiring 10Mm Copper Wire And Flexible Cable At Dinjan Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work in cement mortar or cement lime mortar incl all quions,arches,pillars etc complete all as specified and directed. |
| 2 | M&L for brickwork with subclass 'B' bricks well burnt straight or curved on plan exc 6m mean radius, built in cement mortor 1:4 complete all as specified and directed. |
| 3 | M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement Mortar in 1:4 using water proofing compound in top layer (Water Proofing Compound measured separately) finished even and smooth (without using extra cement) complete all as specified and directed. |
| 4 | M&L for hard core of broken stones of guage not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 5 | M&L Cement concrete Type D2 1:4:8(40mm graded aggregate) in surface channels and drains complete all as specified and directed. |
| 6 | M&L for Reinforced cement concrete M-25 (design mix) using as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 7 | M&L for R.C.C Design Mix Walls M-25 as in, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttressescomplete all as specified and directed. |
| 8 | M&L for Use and waste form work flats sides to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work ; not exc 200 mm thick complete all as specified and directed. |
| 9 | M&L for Formwork to for fair finished surfaces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better complete all as specified and directed. |
| 10 | M&L for MS TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending etc and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in reinfocemetn complete all as specified and directed. |
| 11 | M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending etc and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in reinfocemetn complete all as specified and directed. |
| 12 | M&L for RCC 1:2:4 type B-1 (20 mm graded aggregate )precast concrete as in cover slab set in CM (1:4) including necessary form work complete all as specified and directed. |
| 13 | Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 300mm dia complete all as specified and directed. |
| 14 | M&L for Reinforced concrete pipes 300 mm dia class NP2 laid and jointed complete with collars complete all as specified and directed. |
| 15 | M&L for cement concrete C-2 (1:3:6) for 300mm pipe bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed. |
| 16 | M & L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 32x6 mm earthiing lead by means of bolts and nuts checknuts and washers of galvanised iron or steel all as specified and shown in elecrical plate no 3 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 80 mm dia 150 mm long reinforcement,watering funnel,40 mm dia light grade for protection of earth electrode 20 mm dia for watering complete all as specified and directed. |
| 17 | Supply & Laying or Fixing or Passing through Pipe XLPE insulated, Armoured or unarmoured Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, as per IS 7088(part 1) 1988 with upto date amendments having Nominal Cross-Sectional Area 6 sqmm 4 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc including taking down complete all as specified and directed. |
| 18 | Supply & Laying or Fixing or Passing through Pipe XLPE insulated, Armoured or unarmoured Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, as per IS 7088(part 1) 1988 with upto date amendments having Nominal Cross-Sectional area 10 sqmm 2 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc including taking down complete all as specified and directed. |
| 19 | Supply & Laying or Fixing or Passing through Pipe XLPE insulated, Armoured or unarmoured Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, as per IS 7088(part 1) 1988 with upto date amendments having Nominal Cross-Sectional Area 16 sqmm 2 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc including taking down complete all as specified and directed. |
| 20 | Supply & fixing in repair of MCB SPN 32 Amps 'c' Series 10 KA, 240 volts complete all as specified and directed. |
| 21 | S&F lay cable PVC insulated industrial flexible FR 1100 volt grade with stranded copper conductor of size 1.5 sqmm 3 core from juction box to light's input terminal complete all as specified and directed |
| 22 | S&F of juction box single pole having 1 bus bar for phase and 1 for neutral, clamping on post lanterns as IP55 all complete all as specified and directed. |
| 23 | M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 all complete all as specified and directed. |
| 24 | Supply, install, testing and commissioning outdoor type LT panel of size 1.2m x 1.2m x 0.6m , with latest IP factory made totally enclosed dust and vermin proof , double steef shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door painted with powder coated paint and aluminium bus bar 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items for (FP- I) Note : Foundation to be included in the quoted price:-Incoming :-(a)MCCB, 4 Pole, 250A, 415 V, 25 kA. (I/C). Thermal Magnetic release(b) 3 Phase LED Voltmeter Cl-1(c) Phase indicator lamps (RYB) -set of 3(d) aluminium bus bar 4 strip - 400 amps(e) Internal connection by aluminium strip from mcb/mccb to busbar and busbar to mccb/mcb etcOutgoing :-(a) MCCB, 4 Pole, 160A, 415 V 25 kA - 02 nos (O/G FOR FP)(w+s)(b) MCCB, 4 Pole, 100A, 415 V 25 kA - 01 nos(c) MCCB, 4 POLE , 63A, 240 V, 18 kA - 06 No. |
| 25 | Excavating in trenches n.exc 1.5 mtrs wide and n.exc 1.5 mtr in depth for taking out for laying of cables, poles etc and getting out in soft/loose soil complete all as specified and directed. |
| 26 | Removing excavated materials n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point in soil, complete all as specified and directed. |
| 27 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and directed. |
| 28 | M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. (Punned thickness shall be measured and paid for) |
| 29 | S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and directed. |
| 30 | Supply & fixing of Tubes, 'light grade' galvanised 20mm bore, with all fitting and fixed complete to walls and ceilings or laid in floors to run cables through them for its protection including all the accessories required, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender