Tender For Provn Of Two Septic Tanks For 50 X Users Alongwith Replacement Of Complete Sewage Line Incl Two Soakage Well At 23 Inf Dou At Namkum Pocket Of Ranchi Mil Stn
Tender Value
22.33 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
8 days left
EMD
44700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Two Septic Tanks For 50 X Users Alongwith Replacement Of Complete Sewage Line Incl Two Soakage Well At 23 Inf Dou At Namkum Pocket Of Ranchi Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5 metres wide and n.exc 1.5 metres deep for for foundation etc for shafts, cesspits, manholes etc n.exc 10 Sqm on plan and n. exc 1.5 metres in depth and getting out in hard/dense soil. |
| 2 | Excavating over areas exc 10 Sqm on plan, n.exc 1.5m deep and getting out hard/dense soil |
| 3 | Description all as per above ser item No-2 but depth exc 1.5m and n.exc 3m, getting out hard/dense soil |
| 4 | Description all as per above ser item No-2 but depth exc 3m and n.exc 4.5m, getting out hard/dense soil |
| 5 | Returning filling in incl spreading leveling watering, well ramming in layers not etc 25 cm hard/dense soil |
| 6 | Removing excavated materials etc not exc 50 metres depositing where directed at a level of n.exc. 1.5 metres above the starting point |
| 7 | M&L brickwork with sub class 'B' bricks in one brick thick of honey comb walling, built in CM 1:4 complete. |
| 8 | M/L brick work with sub class B bricks built in CM 1:4 straight or curved exceeding 6m mean radius all as specified. |
| 9 | M&L cement concrete (1:4:8) type D2 using 40mm graded stone aggregate in fondation and mass concrete for manhole surface channels and drains |
| 10 | M/L PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in coping, bed etc including necessary use & waste of form work complete all as specified |
| 11 | M&L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specfied and directed |
| 12 | Extra for forming fair finished drain or channels not exc. 30cm inner girth finished even and smooth with using extra cement complete all as specified and directed. |
| 13 | M/L 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces finished even and smooth complete all as specified & directed. |
| 14 | M&L for providing RCC 1:2:4 type B-1 (using 20mm graded aggregate)as in cover slab over drain, manhole cover, bafell wall etc set in CM 1:4 inluding formwork all as specified and directed |
| 15 | M&L Formwork in Flat Rough finished surfaces of concretete sides and soffits of Slab cover, manhole cover, etc. complete all as specifed and directed. |
| 16 | S/F MS TMT bars 10 mm dia and over for reinforcement etc, cut to length, bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed. |
| 17 | Description all as per above ser item No 16 above but 6 to 8 mm dia . |
| 18 | M&L PCC 1:3:6 and type C2 using 40mm graded stone agregate for concrete bed to drain pipes including packing under hunching against the sides of pipes after they laid and tested for 150mm dia pipes |
| 19 | M&L Salt-glazed stone ware drain (SWSG) pipe grade 'A' 150 mm dia laid in trenches & jointed in CM 1:1 and tested complete all as specified. |
| 20 | S & F ultra Plus PE, DWC ( double wall corrugated) pipe confirming IS 16098 part II 2013, pertaining structured wall plastic pinning system for non pressure drainage and sewerage 150mm bore pipe and fitting with non smooth surface, type B complete all as specified and directed. |
| 21 | Cutting into existing manholes for connecting new drains making good to pipes and rendering, cutting existing benching for forming branch channel etc for 150mm pipes. |
| 22 | Cleaning of blockage of WCs , bath room, blockage of sewage pipe line any dia, manhole etc. as per day to day complain by rodding or by any meachanical cleaning equipment all as specified and directed by Engr in charge. (Note: Measurement will be taken from one manhole/gully trap to another manhole/gully trap) |
| 23 | S&F in repairs 110mm dia, PVC (SWR) Pipes single socketed in any length with rubber rings joints land in trenches or floor and making good the surface all as specified and directed by the EIC. |
| 24 | S&F in repairs 110mm dia, PVC (SWR) Pipes single socketed in any length with rubber rings joints fixed to walls all as specified and directed by the EIC. |
| 25 | S&F in repairs 75mm dia, PVC (SWR) Pipes single socketed in any length with rubber rings joints fixed to walls all as specified and directed by the EIC. |
| 26 | S&F Stack clamp out of 50mm by 5mm flat iron and 16mm dia round iron stays for 75mm dia of pipe in repair,including bolts and nuts and securing ends of stays to wall or roof completed all as specified and directed |
| 27 | S&F Stack clamp out of 50mm by 5mm flat iron and 16mm dia round iron stays for 100mm dia of pipe in repair,including bolts and nuts and securing ends of stays to wall or roof completed all as specified and directed |
| 28 | S&F PVC (SWR) vent cowl, 110 mm dia |
| 29 | S&F PVC (SWR) bend, 110 mm dia |
| 30 | S&F PVC (SWR) junction single, (Single T) equal or unequal 110mm dia |
| 31 | S&F PVC (SWR) bend, 75 mm dia |
| 32 | S&F PVC (SWR) junction single, (Single T) equal or unequal 75mm dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender