Tender For Repair/ Replacement Of Flame Proof Sub Main Wiring, Dbs, And Fitting Fixtures At South Loop Area At Af Stn Nal Under Ge (Af) Nal
Tender Value
30 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
12 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement Of Flame Proof Sub Main Wiring, Dbs, And Fitting Fixtures At South Loop Area At Af Stn Nal Under Ge (Af) Nal
BOQ
| Sl. No. | Item Description |
| 1 | Taking down U/S existing sub main wiring copper/ aluminium conductor including PVC or steel conduit/ casing and capping etc complete all as specified and directed. |
| 2 | Supply and laying sub main wiring complete with 05 runs ( 3 Nos for three phase, Neutral & Earthing colour code) of single core 10 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metallic conduit ISI marked and accessories surface fixed on wall /floor etc complete all as specified and directed. Note:- 05 runs of cable and 01 run of steel conduit shall be measured as one unit for measurement purposes. |
| 3 | Supply and laying sub main wiring complete with 05 runs ( 3 Nos for three phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metallic conduit 20mm dia(minimum) ISI marked and accessories surface fixed on wall /floor etc complete all as specified and directed.Note:- 05 runs of cable and 01 run of steel conduit shall be measured as one unit for measurement purposes. |
| 4 | Supply and laying sub main wiring complete with 03 runs ( Phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metallic conduit 20mm dia(minimum) ISI marked and accessories surface fixed on wall /floor etc complete all as specified and directed. Note:- 03 runs of cable and 01 run of steel conduit shall be measured as one unit for measurement purposes. |
| 5 | Supply and laying sub main wiring complete with 03 runs ( Phase, Neutral & Earthing colour code) of single core 2.5 sqmm fire retardant low smoke and halogen (FRLSH) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metallic conduit 20mm dia(minimum) ISI marked and accessories surface fixed on wall /floor etc complete all as specified and directed. Note:- 03 runs of cable and 01 run of steel conduit shall be measured as one unit for measurement purposes. |
| 6 | Supply & fixing in repair LED 1x20 watt FLAME PROOF tube light fixture luminaries including integral reflector made of diecast aluminum alloy LM6 , with electronic ballast, bipin holders, .connector block, etc., and all accessories pre-wired and including connecting up with suitable size copper conductor twin core cable including taking out existing unserviceable normal or flame proof light complete all as specified and directed. |
| 7 | S & F in repair round high bay light LED flameproof well glass in die cast AL housing with heat resistant toughened glass suitable for Gas/Vapour group of IIA & IIB and zone 1 & 2 of 60 watt capacity including taking out existing unserviceable lights complete all as specified and directed. |
| 8 | Supply and fix in repair Flame proof - weather proof CMRI approved MCB socket & plug with 16 AMP rotary switch combined 16 A, 250V (2P+Earth) complete all as specified and directed. |
| 9 | Supply and fix in repair Flame proof - weather proof CMRI approved 3 phase MCB socket & plug 32 Amp with rotary switch combined 500V(4P+Earth) complete all as specified and directed. |
| 10 | Supply & fix in repair Flame proof Sheet metal enclosure SPN 4 way for fixing MCBs 240 volt including MCB DP 20 A- 1 No as incomer & MCBs SP 6 to 16 Amps-2 Nos as outgoing complete all as specified and directed . |
| 11 | Supply & fix in repair Flame proof Sheet metal enclosure SPN 6 way for fixing MCBs 240 volt including MCB DP 32 A- 1 No as incomer & MCBs SP 6 to 16 Amps-4 Nos as outgoing complete all as specified and directed. |
| 12 | Supply and fixed-in-repair, Flame proof, Sheet metal enclosure, SPN 10 way for fixing MCBs 240 volt including providing MCB DP 40A- 1.00 number as incomer & MCBs SP 6 to 16 Amps-8.00 Nos as outgoing, as specified and directed. |
| 13 | Supply & fix in repair Flame proof Sheet metal enclosure TPN 4 way for fixing MCBs 240 volt including MCB TPN 63 A- 1 No as incomer & MCBs SP 6 to 16 Amps-12 Nos as outgoing complete all as specified and directed . |
| 14 | Supply & Fix in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 15 | Supply & Fix in repair 3 way/4 Way flame proof junction box suitable for carrying 4/6 sqmm 3 phase/single phase sub main wiring complete all as specified and directed by Engineer-In-Charge. |
| 16 | Supply and fixing in repair knobe suitable for existing flame proof SPN/TPN DB or rotary switch with complete all as specified and directed Please Enable Macros to View BoQ information |
| 17 | Supply and fixing in repair knobe suitable for existing flame proof SPN/TPN DB or rotary switch with complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender