Tender For Repair & Maintenance Of Water Supply Distribution Of Ci/Di/Gi Pipe Lines And Repair , Maintanance & Replacement Of Apfc Panel, Distribution Panel, Mccb , Changeover Switch , Earthing & Other Connected Electric Works At Alhilal Mil Under Ge
Tender Overview
Project Description
Tender for Repair & Maintenance Of Water Supply Distribution Of Ci/Di/Gi Pipe Lines And Repair , Maintanance & Replacement Of Apfc Panel, Distribution Panel, Mccb , Changeover Switch , Earthing & Other Connected Electric Works At Alhilal Mil Under Ge Pal Ur
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for foundation, taking up/down or laying of GI tubing/CI pipe etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed. |
| 2 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified & directed. |
| 3 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed. |
| 4 | Cutting the existing hard standing/metal road to facilitate for laying of GI pipe line/LT cables and making good the disturbed portion to bring it to original condition with PCC 1:4:8 type D2 using 40 mm graded stone aggregate all as specified and as directed. |
| 5 | Taking up or down old GI tubing 15 mm bore and connections (including fittings) from trenches/walls /floors and connections including cleaning for re-fixing or remove to store yard/ credited to contractor complete all as specified and directed. |
| 6 | As per item No-5 above but 20 mm dia bore. |
| 7 | As per item No-5 above but 25 mm dia bore. |
| 8 | As per item No-5 above but 40 mm dia bore. |
| 9 | As per item No-5 above but 50 mm dia bore. |
| 10 | As per item No-5 above but 80 mm dia bore. |
| 11 | Taking up or down old GI tubing 100 mm bore and connections (including fittings) from trenches/walls /floors and connections including cleaning for re-fixing or remove to store yard/ credited to contractor complete all as specified and directed. |
| 12 | Taking up or down 150 mm bore CI/DI pipes( including all fittings),with spigot and socket ends or flanged ends and lead joints including burning out joints,rubber joints from trenches/walls /floors including cleaning for re-fixing or remove to store yard/ credited to contractor complete all as specified and directed. |
| 13 | Taking up or down 200 mm bore CI/DI pipes( including all fittings),with spigot and socket ends or flanged ends and lead joints including burning out joints,rubber joints from trenches/walls /floors including cleaning for re-fixing or remove to store yard/ credited to contractor complete all as specified and directed. |
| 14 | Taking up or down 250 mm bore CI/DI pipes( including all fittings),with spigot and socket ends or flanged ends and lead joints including burning out joints,rubber joints from trenches/walls /floors including cleaning for re-fixing or remove to store yard/ credited to contractor complete all as specified and directed. |
| 15 | Supplying, laying, jointing and testing 15 mm bore galvanised steel water tubing medium grade (ISI marked) laid in trenches with medium grade galvanised iron fitting (ISI marked) such as bends, tees, sockets, nipples & unions, flanges etc complete all as specified and directed. |
| 16 | Supplying, laying, jointing and testing 20 mm bore galvanised steel water tubing medium grade (ISI marked) laid in trenches with medium grade galvanised iron fitting (ISI marked) such as bends, tees, sockets, nipples & unions, flanges etc complete all as specified and directed. |
| 17 | Supplying, laying, jointing and testing 25 mm bore galvanised steel water tubing medium grade (ISI marked) laid in trenches with medium grade galvanised iron fitting (ISI marked) such as bends, tees, sockets, nipples & unions, flanges etc complete all as specified and directed. |
| 18 | Supplying, laying, jointing and testing 40 mm bore galvanised steel water tubing medium grade (ISI marked) laid in trenches with medium grade galvanised iron fitting (ISI marked) such as bends, tees, sockets, nipples & unions, flanges etc complete all as specified and directed. |
| 19 | Supplying, laying, jointing and testing 50 mm bore galvanised steel water tubing medium grade (ISI marked) laid in trenches with medium grade galvanised iron fitting (ISI marked) such as bends, tees, sockets, nipples & unions, flanges etc complete all as specified and directed. |
| 20 | Supplying, laying, jointing and testing 80 mm bore galvanised steel water tubing medium grade (ISI marked) laid in trenches with medium grade galvanised iron fitting (ISI marked) such as bends, tees, sockets, nipples & unions, flanges etc complete all as specified and directed. |
| 21 | Supplying, laying, jointing and testing 100 mm bore galvanised steel water tubing medium grade (ISI marked) laid in trenches with medium grade galvanised iron fitting (ISI marked) such as bends, tees, sockets, nipples & unions, flanges etc complete all as specified and directed. |
| 22 | Supply, laying, jointing and testing of DI pipe 150 mm bore with spigot and socket ends, centrifugaly cast class-K-9 suitable for tyton joints, in any length, laid in trenches/pillars complete all as specified and directed. |
| 23 | Supply, laying, jointing and testing of DI pipe 200 mm bore with spigot and socket ends, centrifugaly cast class-K-9 suitable for tyton joints, in any length, laid in trenches/pillars complete all as specified and directed. |
| 24 | Supply, laying, jointing and testing of DI pipe 250 mm bore with spigot and socket ends, centrifugaly cast class-K-9 suitable for tyton joints, in any length, laid in trenches/pillars complete all as specified and directed. |
| 25 | Material and labour for CI Fittings such as bends (any type radius and angle ) tapers any type , bends , tee pieces single branch Y junction double branch , cross (all type socket as spigot and socket etc) ,collar , cap and plugs suitablr for spigot and socket pipes upto 150 mm bore including rbber gasket complete all as specified and directed. |
| 26 | Material and labour for CI Fittings such as bends (any type radius and angle ) tapers any type , bends , tee pieces single branch Y junction double branch , cross (all type socket as spigot and socket etc) ,collar , cap and plugs suitable for spigot and socket pipes from 200mm bore upto 300 mm bore including rubber gasket complete all as specified and directed. |
| 27 | Supply, installation, connecting and testing sluice valve 100 mm bore cast iron body class-PN-1.6 with flanged ends drilled pipes, ISI marked (IS:14846:2000), having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket, etc including taking down old un-serviceable sluice valvecomplete all as specified and directed. |
| 28 | Supply, installation, connecting and testing sluice valve 150 mm bore cast iron body class-PN-1.6 with flanged ends drilled pipes, ISI marked (IS:14846:2000), having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket, etc including taking down old un-serviceable sluice valve all complete all as specified and directed. |
| 29 | Supply, installation, connecting and testing sluice valve 200 mm bore cast iron body class-PN-1.6 with flanged ends drilled pipes, ISI marked (IS:14846:2000), having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket, etc including taking down old un-serviceable sluice valve complete all as specified and directed. |
| 30 | Supply, installation, connecting and testing sluice valve 250 mm bore cast iron body class-PN-1.6 with flanged ends drilled pipes, ISI marked (IS:14846:2000), having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket, etc including taking down old un-serviceable sluice valve complete all as specified and directed. |
| 31 | S&F Cast iron Air valve with two outlets both ends flanged and drilled, of size 80 mm bore, (ISI marked) conforming to IS-14846 -2000 with pressure rating of PN-1.6 with stainless steel spindle and iron wheel head including jointing material such as nuts, bolts, washers and rubber gasket etc,including taking out old un-serviceable complete all as specified and directed. |
| 32 | S&F in replacement of mechanical joint suitable for 100 mm bore CI/DI/GI pipe lines with all its fittings as required for jointing the pipe lines including taking out old un-serviceable one complete all as specified and directed. |
| 33 | S&F in replacement of mechanical joint suitable for 150 mm bore CI/DI/GI pipe lines with all its fittings as required for jointing the pipe lines including taking out old un-serviceable one complete all as specified and directed. |
| 34 | S&F in replacement of mechanical joint suitable for 200 mm bore CI/DI/GI pipe lines with all its fittings as required for jointing the pipe lines including taking out old un-serviceable one complete all as specified and directed. |
| 35 | S&F in replacement of mechanical joint suitable for 250 mm bore CI/DI/GI pipe lines with all its fittings as required for jointing the pipe lines including taking out old un-serviceable one complete all as specified and directed. |
| 36 | S&F in repair 50 mm bore gun metal, gate valve, heavy duty confirming to IS -778 with iron wheel head, screwed both ends for iron pipe including taking out old un-serviceable one complete all as specified and directed. |
| 37 | S&F in repair 40 mm bore gun metal, gate valve, heavy duty confirming to IS -778 with iron wheel head, screwed both ends for iron pipe including taking out old un-serviceable one complete all as specified and directed. |
| 38 | S&F in repair 25 mm bore gun metal, gate valve, heavy duty confirming to IS -778 with iron wheel head, screwed both ends for iron pipe complete including taking out old un-serviceable one complete all as specified and directed. |
| 39 | S&F in repair 20 mm bore gun metal, globe or gate valve, heavy duty confirming to IS -778 with iron wheel head, screwed both ends for iron pipe complete including taking out old un-serviceable one complete all as specified and directed. |
| 40 | S&F in repair 15 mm bore gun metal, globe or gate valve, heavy duty confirming to IS -778 with iron wheel head, screwed both ends for iron pipe complete including taking out old un-serviceable one complete all as specified and directed. |
| 41 | Cutting of existing 200mm bore cast iron pipe in position to required length for repairs of blockage or insert new CI fitting such as collers, branches,tee etc or pipe complete all as specified and directed. Note:- Excavation and earth work,fittings,pipe etc shall be measured and paid saperately. |
| 42 | Cutting of existing 150mm bore cast iron pipe in position to required length for repairs of blockage or insert new CI fitting such as collers, branches,tee etc or pipe complete all as specified and directed. Note:- Excavation and earth work,fittings,pipe etc shall be measured and paid saperately. |
| 43 | M&L run lead joint for cast iron spigot and socket pipe (water main) and fittings for 100 mm bore including taking out old lead from joints complete all as specified & directed. Note:-Excation and earth work shall be measured and paid separately |
| 44 | M&L run lead joint for cast iron spigot and socket pipe (water main) and fittings for 150 mm bore including taking out old lead from joints complete all as specified & directed. Note:-Excavation and earth work shall be measured and paid separately |
| 45 | M&L rubber gasket joints (tyton joints) for CI/DI pipes of 100mm bore spigot and socket pipes including taking out old unserviceable tyton joint complete all as specified & directed. Note:-Excavation and earth work shall be measured and paid separately |
| 46 | M&L rubber gasket joints (tyton joints) for CI/DI pipes of 150mm bore spigot and socket pipes including taking out old unserviceable tyton joint complete all as specified & directed. Note:-Excavation and earth work shall be measured and paid separately |
| 47 | Dismantling of existing brick masonry valve pit 750x750x750mm or 120mmx120mmx120mm including stacking serviceable material for credited to contractor and removal of unserviceable material from site complete all as specified and directed. |
| 48 | M&L construction of valve pit of inner sizes 750 x 750 x 750mm brick masonry construction complete with mild steel sheet cover 3.15 mm thick and angle iron frame of size 50x50 x 6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and including locking arrangement and lifting handle all as specified and shown on drawing. All internal surface and external surface upto 15 cm below normal ground level of brick masonry shall be plastered 15mm thick in cement mortar 1:4, finish even and smooth including necessary excavation and earth work in any type of soil and PCC work all as per TD drg complete all as specified and directed. |
| 49 | S&F in replacement 80 mm union for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 50 | S&F in replacement 50 mm union for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 51 | S&F in replacement 40 mm union for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 52 | S&F in replacement 25 mm union for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 53 | S&F in replacement 20 to 15 mm Reducer Socket for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 54 | S&F in replacement 25 to 20 mm Reducer Socket for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 55 | S&F in replacement 25 to 15 mm Reducer Socket for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 56 | S&F in replacement 25 mm Elbow for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 57 | S&F in replacement 50 mm Elbow for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 58 | S&F in replacement 25 mm Socket for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 59 | S&F in replacement Nipple 20 mm 4 inch Long for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 60 | S&F in replacement Nipple 25 mm 4 inch Long for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 61 | S&F in replacement Nipple 50 mm 4 inch Long for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 62 | S&F in replacement Tee 25 mm for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 63 | S&F in replacement Tee 50 mm for GI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 64 | S&F Spun Yarn for CI pipe including taking out old un-serviceable one complete all as specified and directed. |
| 65 | S & F in replacement PVC float valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed for 15 mm bore GI tubing complete all as specified and directed . |
| 66 | S & F in replacement PVC float valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed for 20 mm bore GI tubing complete all as specified and directed . |
| 67 | S & F in replacement PVC float valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed for 25 mm bore GI tubing complete all as specified and directed. |
| 68 | M&L inspection, cheking and repair of APFC panel by cleaning of dust inside with blower, cleaning of moving part/contract from CT cleaner, tightening of loose parts/electrical wiring , cleaning of contractors, relays and capacitor juction points, oiling of cooling fan , complete testing of APFC relay with necessary settings with CTs /load adjustments to match with the APFC load management system complete with replacement of burnt/worn out unserviceable components /burnt wires thimbles /lugs etc for APFC panel capcity 50 KVAR to 150 KVAR complete all as specified and directed. Note : All unserviceable parts shall be measured and paid seprately as supply only. Replacment of small nuts/screws, wires lugs or thimbles and cleaning material cost included in this item. |
| 69 | Supply only MCB, TP 6 to 32 Amp 10 KA C curve for existing APFC panel complete all as specified and directed. |
| 70 | Supply only MCB, TP 40 to 63 Amp 10 KA C curve for existing APFC panel complete all as specified and directed. |
| 71 | Supply only Auxillary contractor 1 NO+1NC TP 415 volts suitable for 25 KVAR rating for existing APFC panel complete all as specified and directed. |
| 72 | Supply only Auxillary contractor 1 NO+1NC TP 415 volts suitable for 50 KVAR rating for existing APFC panel complete all as specified and directed. |
| 73 | Supply only capacitor 440 volts 50 Hz 15 KVAR for existing APFC panel complete all as specified and directed. |
| 74 | Supply only capacitor 440 volts 50 Hz 25 KVAR for existing APFC panel complete all as specified and directed. |
| 75 | Supply only capacitor 440 volts 50 Hz 50 KVAR for existing APFC panel complete all as specified and directed. |
| 76 | Supply only APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 6 stages for existing APFC panel complete all as specified and directed. |
| 77 | Supply only APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 8 stages for existing APFC panel complete all as specified and directed. |
| 78 | Material and labour for danger notice plate of 1.6 mm thick Mild Steel sheet vitreous enamelled white with letters figure and conventional skull & bones in signal red colour & fixed with MS clamps, bolt,nuts of approved size for LT 20 x 15 cm size including dismantling the old unserviceable one,complete all as specified and directed. |
| 79 | Taking out old unsv indoor and outdoor feeder pillar box, junction box including dismantling PCC foundation, all elctrical and earthing connections complete all as specified and directed. |
| 80 | Supply, Installation and commissioning and testing of CPRI approved LT panel cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, with canopy sloped top projected, floor mounted outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 2.8 mm thick CRCA sheet, internal cover and partition made out of 3.15 mm thick CRCA sheet with angle iton 50mm x 50mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium busbar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60 CM above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washers etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed. :- (a) MCCB 250 Amps, 25KA 4 pole -1 No (As Incomer)(b) MCCB100A, 16KA 4 pole -3 No(c) MCCB 125 A, 16KA 4 pole -1 No(d) Spare Pocket for Fixing MCCB (f) Aluminium busbar 250 Amps TPN- 04 Nos (02 set as incoming & outgoing) (e) Digital voltmeter 0-500 Volts with selecter switch - 01 Nos(f) Digital Amp Meter 0-500 Amp with selector switch & CT 01 No (g) Indicator lamp LED type (R, Y, B) complete with bakelite fuse fitting - 01 Set(h) Cable entry gland and two no earthing terminal |
| 81 | Supplying and fixing of On-load type Changeover switch 100 Amp, 4-pole, 415 volt, open execution type complete all as specified and as directed. |
| 82 | Supply & Fixing in replacement MCCB 4 pole 63 amps 50Hz 415 volts with reputing cap 16 KA complete all as specified and directed. |
| 83 | Supply & Fixing in replacement MCCB 4 pole 100 amps 50Hz 415 volts with reputing cap 16 KA complete all as specified and directed. |
| 84 | Supply & Fixing in replacement MCCB 4 pole 125 amps 50Hz 415 volts adjustable type with reputing cap 16 KA complete all as specified and directed. |
| 85 | Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 25KA complete all as specified and directed. |
| 86 | Supply & Fixing in replacement MCCB 4 pole 200 amps 50Hz 415 volts adjustable type with reputing cap 25KA complete all as specified and directed. |
| 87 | Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified and directed. |
| 88 | Supply & Fixing in replacement MCCB 4 pole 400 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as specified and directed. |
| 89 | Supply & fixing in replacement Aluminium thimbles for LT panels in cable and connecting upto with GI nut bolts and washers suitable for 10 Sqmm to 50 Sqmm cable size complete all as specified and directed. |
| 90 | Supply & fixing in replacement Aluminium thimbles for LT panels in cable and connecting upto with GI nut bolts and washers suitable for 70 Sqmm to 95 Sqmm cable size complete all as specified and directed. |
| 91 | Supply & fixing in replacement Aluminium thimbles for LT panels in cable and connecting upto with GI nut bolts and washers suitable for 120 Sqmm to 150 Sqmm cable size complete all as specified and directed. |
| 92 | S&F in replacement MCCB bus bar chamber box TPN suitable for 63A TPN Aluminium bus bar with INCOMING MCB 63 AMP 4 POLE 415 Volt ways with canopy sloped top projected, floor mounted outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of thick CRCA sheet, internal cover and partition made out of CRCA sheet with angle iton 50mm x 50mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium busbar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60 CM above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washers etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed. |
| 93 | Supply and fix in repairs Voltmeter 0-500 volt square type complete with necessary fixing complete all as specified and directed. |
| 94 | Supply and fix in repairs ammeter 0-100 amps square type complete with necessary fixing complete all as specified and directed. |
| 95 | Supply and fix in repairs Phase indicating lamp ( R.Y.B ) set of three type complete with necessary fixing complete all as specified and directed. |
| 96 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead Strip 32x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40 mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40 mm dia GI medium grade earth lead protection pipe upto 7.5 mtr length complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender