Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56256114

Tender For Repair/ Maintenance Of Internal Electrification Including Lt Panels And Xlpe Cables, Repair/ Maintenance Of Cooling Appliances Such As Water Cooler, Refrigerator And Acs At Ahq C Lodhi Road & Echs Polyclinic Lodhi Road And Repair/ Maintena

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Jul 2026
0 days left
EMD
68220
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Internal Electrification Including Lt Panels And Xlpe Cables, Repair/ Maintenance Of Cooling Appliances Such As Water Cooler, Refrigerator And Acs At Ahq C Lodhi Road & Echs Polyclinic Lodhi Road And Repair/ Maintenance Of Dg Sets, Lt Panel, Lt Ug Cables, Security Lights & Related Works At Ndc Under Ge New Delhi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-Jul-2026

BOQ

Name of Work:- REPAIR/ MAINT OF INTERNAL ELECTRIFICATION INCLUDING LT PANELS AND XLPE CABLES, REPAIR/ MAINT OF COOLING APPLIANCES SUCH AS WATER COOLER, REFRIGERATOR AND ACs AT AHQ C LODHI ROAD & ECHS POLYCLINIC LODHI ROAD AND REPAIR/ MAINT OF DG SETS, LT PANEL, LT UG CABLES, SECURITY LIGHTS & RELATED WORKS AT NDC UNDER GE NEW DELHI
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE NEW DELHI Name of Work: REPAIR/ MAINT OF INTERNAL ELECTRIFICATION INCLUDING LT PANELS AND XLPE CABLES, REPAIR/ MAINT OF COOLING APPLIANCES SUCH AS WATER COOLER, REFRIGERATOR AND ACs AT AHQ CAMP LODHI ROAD & ECHS POLYCLINIC LODHI ROAD AND REPAIR/ MAINT OF DG SETS, LT PANEL, LT UG CABLES, SECURITY LIGHTS & RELATED WORKS AT NDC UNDER GE NEW DELHI Contract No: GE/ND-39/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Taking down carefully old point wiring (Light / Fan/ Socket/ Bell Point) with aluminium/ copper conductor cable complete including fittings such as ceiling rose, holders, regulators, bell, switch and socket from existing concealed conduits/ casing caping and making good the disturbed surface of wall/ floor complete to match with the existing surface/ finishes complete all as specified and directed by Engg in charge.
3M&L for Point wiring for one light/ ceiling fan/ exhaust fan point controlled by one, one way 6 Amp switch with 1.5 sqmm PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn thorugh and new non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marking, concealed Frame for fixing switches, sockets, inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable FRLS grade as in earth wire for continuity and connecting to earth dolly for one light point controlled by one switch complete including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the wall (wash/ paint/ distemper) wherever required (as per the existing condition) complete all as specified and directed.Note: The cost of modular metal flush box and Modular white Cover Plate with Frame, MS terminal boxes and blank plate if required shall be deemed to be included in the unit rate.Make: RR kabel/ Polycab/ Havells/ Gloster/ Finolex
4All as per Item No 02.00 above but for One 3 pin 5 Amp socket outlet on the same board complete all as specified and directed.
5All as per Item No 02.00 above but for One 3 pin 5 Amps socket outlet on independent board complete all as specified and directed.
6All as per item No 2.00 above but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer-in-Charge.Make: RR kabel/ Polycab/ Havells/ Gloster/ Finolex
7All as per item No 2.00 above but with 4.0 sqmm single core copper (for Phase, Neutral) and sqmm (for continuous earth wire) cable for one three pin AC/Geyser Outlet point on independent board complete all as specified and directed. Make : RR Kabel, Polycab, Finolex, Gloster, Havells
8S&F in replacement of Flush Type Piano Switch single Pole 6 Amp 250V AC with ISI mark including 6 Amps Switch frame complete all as specified and directed by Engg in charge.Make : Anchor, IndoAsian, Legrand, Panasonic, Goldmedal, Havells
9S&F in replacement of Flush Type Piano switch 16 A SP one way 240 volts complete all as specified and directed. Make : Anchor/Indoasian/Legrand/Panasonic/Goldmedal/Havells, KEI
10S&F in replacement Flush Type socket 6 A Multi socket for 2 pin and 3 pin 240 volts complete all as specified and directed. Make : Anchor/Indoasian/Legrand/Panasonic/ Goldmedal/ Havells
11S&F in replacement of Flush Type Multi Socket outlet 16 A-2/3 pin combined 240 volts complete all as specified and directed. Make : Anchor/Indoasian/Legrand/Panasonic/ Goldmedal/Havells
12S&F in replacement LED lights fitting 1x 20W (Size 4 Feet) 220V, AC Warm/Natural White decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Philips, Bajaj, Crompton, Orient, Havells, Polycab, Halonix
13S&F in replacement LED light fitting with high output diffuser 10W (Size 2 Feet) 220V, AC Warm/Natural White decorative box type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Philips, Bajaj, Crompton, Orient, Havells, Polycab, Halonix
14S&F in replacement aesthetically designed wall mounted decorative wall LED light of 15W fixture with opal diffuser to give glare free light including suitable LED lamp of 15W, complete all as specified and directed.Make: Philips Cat Part No. Muziris 31434, Lustre Cat Part No. LI 3618/IW, Wipro Cat Part No. BW06
15S&F in replacement LED light fitting upto 15 Watt bulkhead luminaires circular shaped including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge. Make : Philips, Bajaj, Crompton, Orient, Havells, Polycab, Halonix
16S&F in replacement warm/natural white LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make : Philips, Bajaj, Crompton, Orient, Havells, Polycab, Halonix
17S&F in replacement PVC gang box with Cover plate 2/3 module suitable for fitting one 5 Amp switch and one 5 Amp socket complete all as specified and directed by Engg in charge.Note : No of Switches and Socket required are included in the quoted rate.
18S&F in replacement PVC gang box with cover 04 module suitable for fitting one 15 Amp switch and one socket complete all as specified and directed. Note : No of Switches and Socket required are included in the quoted rate.
19S&F in replacement PVC gang box with cover 6 module suitable for fitting switch and socket of 5 Amp complete all as specified and directed. Note : No of Switches and Socket required are included in the quoted rate.
20S&F in replacement electronic fan regulator modular type 120Watt dimmer / step type any Module as per existing complete all as specified and directed. Make : Anchor/Indoasian/Legrand/Panasonic/Goldmedal/Havells
21S&F in replacement fan capacitor 2.5 mfd capacity complete all as specified and directed.Make : Epcos/ Anchor
22S&F in replacement ceiling fans complete with blades, down rods, accessories, 230 V, 1200 mm sweep. Min air delivery 230 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) ceiling fan with remote of color white or (As per site requirment) complete with all accessories internally pre wired and including connecting up with three core flexible copper conductor cable with suitable size and making arrangement to hanging of fan to ceiling with proper hook nut bolt complete all as specified and directed. Make : Havells, Crompton, Orient, Atomberg, Usha, Bajaj, Polycab, Halonix
23S&F in replacement PVC body ventilation fans AC single phase 230/240 V of size 250 mm sweep (as per sample ) complete all as specified and directed. Make : Havells, Crompton, Orient, Usha, Bajaj, Polycab, Halonix
24Taking down carefully Geysers 25/50 Ltr capacity, opening for inspection, , cleaning, descaling, reassembling and refixing in position after carrying out repairs like soldering/ brazing etc including replacement of pressed rubber gasket, Nuts, bolts, neon indicator lamp 1 Amp etc complete all as specified and directed by Engg in charge.
25M&L for spray painting (white colour) with synthetic enamel paint to Geysers 25/50 Liters capacity to reach upto satisfied finish of painting after cleaning and preparation of surface and marking MES No with black paint complete all as specified and directed by Engineer-in-charge.
26S&F in replacement heating element of 2.0 KW (Rectangle/triangle /circular ) as required at site including rubber washers (ISI marked) etc complete all as specified and directed.Make : Venus or As per sample.
27S&F in replacement storage tank made out of steel sheet of appropriate thickness and confirming to IS 208 (1974) for 25 litre capacity geysers with collar complete duly tested at required pressure as per IT I of 1986 of steel storage tank complete all as specified and directed.
28S&F in replacement base plate assembly 20 SWG heavy duty suitable for 25/50 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample) complete all as specified and directed.
29S&F in replacement chromium plated copper connection pipe 600mm long with two brass adopters washers and connecting up complete all as specified and directed.
30S&F in replacement thermostat for 25/50 Litres for any type geyser complete all as specified and directed. (As per sample)
31S&F in replacement mild steel hole fastner 10mm dia, 100mm long including nut and washer complete all as specified and directed.
32S&F in replacement PVC wire 1.5 Sqmm of FRLSH PVC insulated copper conductor, single core cable drawn through existing PVC conduit of 20 mm dia bore with all fittings accessories complete all as specified and directed. Make : RR Kabel/Havells/ Polycab/ Gloster /Finolex
33S&F in replacement PVC wire 2.5 Sqmm of FRLSH PVC insulated copper conductor, single core cable drawn through existing PVC conduit of 20 mm dia bore with all fittings accessories complete all as specified and directed. Make : RR Kabel/Havells/Polycab/ Gloster /Finolex
34S&F in replacement submain wiring alongwith earth wire with 2 run of 4 Sqmm (Main Cable and neutral) and one run of 4 Sqmm as earth wire of FRLSH PVC insulated copper conductor, single core cable drawn through existing PVC conduit of 25 mm dia bore with all fittings accessories complete all as specified and directed.Make : RR Kabel/Havells/ Polycab/Gloster/Finolex
35S&F in replacement submain wiring alongwith earth wire with 2 run of 6 Sqmm (Main Cable and neutral) and one run of 6 Sqmm as earth wire of FRLSH PVC insulated copper conductor, single core cable drawn through and including uding rigid PVC conduit of 25 mm bore with all fittings accessories complete all as specified and directed. Make : RR Kabel/Havells/Polycab/Gloster /Finolex
36S&F in replacement submain wiring alongwith earth wire with 2 run of 10 Sqmm (Main Cable and neutral) and one run of 10 Sqmm as earth wire of FRLSH PVC insulated copper conductor, single core cable drawn through existing PVC conduit of 25 mm bore with all fittings accessories complete all as specified and directed.Make : RR Kabel/Havells/Polycab/Gloster /Finolex
37S&F in replacements Wall Mounted indoor type factory made load line DB s double door made out of CRCA mild steel sheet with insulating material like polyester powder coated surface mounted 4 way VTPN 415 volts IP 43 protection with suitable bus bar neutral link and earth link suitable for 4 pole MCCB of 125 A as incoming and SP/TP MCB of rating 5 to 100 Amps as outgoing complete all as specified and directed.
38S&F in replacement sheet metal enclosures for DB's when MCB to be used, SPN double door 240 volt, 12 way with 100 Amps rated bus bar complete all as specified and directed. Make : Legrand/C&S/ Indoasian / L&T /Havells/ Schnieder/Siemens
39S&F in replacement sheet metal enclosures for DB's when MCB to be used, SPN double door 240 volt, 8 way with 100 Amps rated bus bar complete all as specified and directed. Make : Legrand/C&S/ Indoasian / L&T /Havells/ Schnieder/Siemens
40S&F in replacement of MCB SPN/DP 40 to 63 Amp 240 volt 10 KA complete all as specified and directed. Make : Legrand/C&S/ Indoasian / L&T /Havells/Schnieder/Siemens
41S&F in replacement of MCB SPN 6-32 Amp 240 volt 10 KA complete all as specified and directed. Make : Legrand/C&S / Indoasian / L&T /Havells/Schnieder/Siemens
42S&F in replacement MCB SP 6 Amp to 32 Amp 10 KA.240 volts complete all as specified and directed. Make : Legrand/C&S / Indoasian / L&T /Havells/Schnieder/Siemens
43Supply and fix Rigid non-metallic PVC conduit upto 50 mm dia including of boxes (junction/ terminal), all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for lan/ telephone circuits complete all as specified and directed. Note : Work includes cutting of chases on wall and making good disturbed surfaces.
44S&F in replacement sheet Metal enclosure with plug and socket 20 Amp 240 volts with one MCB single pole complete all as specified and directed. Make : Legrand/C&S / Indoasian / L&T /Havells/Schnieder/Siemens
45M&L for painting of LT /Meter panel with synthetic enamel paint two coats after one coat of primer (colour decided by engr in charge ) to reach upto satisfied finish of painting after cleaning and preparation of surface and marking qtr No with black paint complete all as specified and directed by Engineer-in-charge. Note : Contractor need to inform RWA -Secretary and Engr in charge one day prior to start the work
46S&F in replacement Indicator of three phase (RGB) set of three with complete accessories complete all as specified and directed.
47M&L in replacement for earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including galvanised earth 4 mm lead wire bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc complete all as specified and directed.
48S&F in replacement non metallic rigid PVC casing caping upto 5 cm wide, ISI Mark complete all as specified and directed. Make : Kalinga Premium/ Supreme
49S&F in replacement Metalic Exhaust Fans AC single phase 230/240V of size 250/300 mm sweep (as per sample ) complete all as specified and directed. Make: Havells, Crompton,Orient, Usha, Bajaj, Polycab, Halonix
50S&F in replacement Louver shutter made of MS for exhaust fan of size upto 300 mm complete all as specified and directed.
51S&F in replacement of MCCB 4-Pole 80 Amp, 25kA thermal type complete all as specified and directed.
52S&F in replacement of MCCB 4-Pole 100 Amp, 36kA thermal type complete all as specified and directed.
53S&F in replacement of MCCB 4-Pole 160 Amp, 36kA thermal type complete all as specified and directed.
54Supply, install and commissioning in replacement of wall fan made of sturdy Engineering plastic, copper wounded motor complete with all accessories , voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 400mm 3 blade, single phase, complete all as specified and directed by Engr-in-Charge.Make : Crompton, Havells, USHA, Bajaj, Orient, Halonix
55S&F inreplacement flexible twin core wire 1.5 Sqmm, white colour complete all as specified and directed.
56S&F in replacement of LED Building security light fitting 25 Watt including GI bracket of suitable size, fixing with clamp, nut, bolt and other connected accessories complete all as specified and directed.Make : Havells/CG/Philips
57S&F inreplacement of IP66/67 (as per IEC 60529) Thermoplastic PC- GFS Polycarbonate Weatherproof, UV resistant due to solar radiation, Rainwater proof, temperature resistant, Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 960 deg C (as per IEC 60695 – 2 – 11) Junction Box having size (205x255x112 mm) Cat No KF 2525G of Hensel/Equivalent in Rittal/ABB/Siemens, on exiting Pole with 1No. 6 Amp 'B' Curve series, 10kA SP MCB i/c supply with pole mounting kit for clamping the box on pole, earthling the body connection, inter- connection, suitable terminal blocks, glands, locknut etc. complete set as reqd. for Pole lighting complete all as specified and directed.
58Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for UG cable etc in soft/ loose soil getting out and levelling of bottom surface to required level complete all as specified and directed by the Engineer-In-Charge.
59Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by the Engineer-In-Charge.
60Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by the Engineer-In-Charge.
61M&L for sand cushioning (dry sand) to underground cable for cable protection laid in trenches / in existing cable ducts complete all as specified and as directed by the Engineer-In-Charge.
62M&L for brick laying with subclass 'B' bricks well burnt, laid dry flat in trenches for protection of cable over cable, complete all as specified and as directed by the Engineer-In-Charge
63S&F in repairs of Mild steel 'U' clamps with rubber reel, bolts, nuts, washers and safety pin complete all as specified and directed.
64M&L for Cutting of existing road surface for laying of underground cables, including breaking of bituminous/WBM/CC road to required width and depth, dressing of sides, and excavation of trench in all kinds of soil, including disposal and backfilling of trench, providing protective covering by suitable dia GI Pipe (if required), and complete reinstatement of road to original condition by providing and laying of sub-base/base course and finishing with premix bituminous carpet/CC as applicable, including compaction, curing, and all incidental works complete as per specifications and direction of Engineer-in-Charge
65Servicing of Split type AC 1.5/2 Ton capacity of any make/model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed. Note: The quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape
66S&F in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 Volt for AC upto 4.00 Ton complete all as specified and directed.
67S&F in repairs Starting relay suitable for upto 1.5/2 Ton capacity AC complete all as specified and directed.Make : Renutrol/Classic/Indfos.
68S&F in replacement over load protector suitable for upto 1.5/2 TR capacity AC any type complete all as specified and directed.Make : Renutrol/Classic/Hitech.
69Supply & charging gas refrigerant R-22/R-32/410A or as existing to window type/Split type/Cassette/Package type AC up to 2 Ton capacity including removing of leakage if any and testing complete all as specified and directed by Engineer-in-charge
70S&F in replacement PCB of non inverter type split type AC of capacity 1.5 to 2.0 Ton and fixing the same in respective units including opening & taking down existing unsv PCB complete all as specified and directed by Engineer-in-charge.
71S&F in replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4\\") for refrigerant copper piping of split AC units complete all as specified and directed.Make:- Supreme/Gulf-o-flex/Superlon.
72S&F in replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8\\") for refrigerant copper piping of split AC units complete all as specified and directed.Make:- Supreme/Gulf-o-flex/Superlon.
73S&F in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 TR as per sample complete all as specified and directed.
74Supply only in replacement cordless Remote for split type ACs suitable for 1.5 Ton AC as per sample complete all as specified and directed.
75S&F in replacement hermeatically sealed reciprocating /Rotary type compressor suitable for 1.5 to 2.0 Ton capacity inverter/non inverter split type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engg in charge.
76S&F in replacement of indoor unit kit suitable for split type AC 1.5/2 Ton with PCB complete with sensor complete with fixing plate suitable to non inverter type AC complete all as specified and directed.
77S&F in replacement of split type AC 1.5/2 Ton outdoor unit kit complete with compressor, condensor coil, condensor fan with blade and sensor suitable to non inverter type existing model and make AC complete all as specified and directed by Engg in charge.
78S&F in replacement new DC fan motor (inoor/outoor) upto 1/4 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed.
79S&F in replacement of evaporating air blower made out of aluminium /plastic suitable for upto 2 Ton capacity for split type AC complete all as specified and directed.
80Labour for checking and attending complants of ACs of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed.Note:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in AHQ CAMP & ECHS POLYCLINIC LODHI ROAD and he must submit copy of valid competency certificate of two (2) AC mechanics each having minimum working experience of two years in the field of air conditioning & refrigeration. The certificates shall be issued by the OEM only stating the technical qualification & experience of the mechanics to be deployed.(b) The complaint should be attended on same day within 3 hours .(c)) If the complaint not attended/not completed on same day within three hours recovery will be done as follows:- (i) For first day Rs.500/- (ii) For second day Rs.800/- (iii) For next every day Rs.1000/-
81S&F in replacement wall stand /chauki stand fastener upto 8 mm size to fix outdoor of split/cassette AC made of Mild Steel duly painted complete all as specified and directed.
82S&F in replacement of thermostat switch suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
83S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity ACs complete all as specified and directed.
84S&F in replacement of air filter Synthetic/Nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type Acs complete all as specified and directed.
85Servicing and gas charging of Refrigerator 265 Litres capacity including cleaning of parts, replacment of minor parts if required, replacement of filters, leakage testing complete all as specified and directed.
86S&F in replacement of compressor suitable for 265 Litres refrigerator complete with required accessories and make as per sample complete all as specified and directed.
87Servicing and gas charging of Water cooler cap 80 Litres including cleaning of parts, replacment of minor parts if required ,replacement of filters ,leakage testing complete all as specified and directed.
88S&F in replacement of compressor of 80 Litres water cooler complete with required accessories and make as per sample complete all as specified and directed.
89S&F in replacement of voltage stabilizer variation 170 to 250 volt cap 2KVA completet set and make as per sample complete all as specified and directed.
90S&F in replacement of voltage stablizer cap 5 kVA suitable for AC 1.5/2 Ton, variation of input 140 to 300 Volts and output from 215 to 240 Volts completet set, make as per sample complete all as specified and directed.
91S&F in replacement Desert Cooler steel body 60 Litres capacity complete set with water pump, Fan Motor, Blades all as specified and directed, including MS stand to mount the cooler (Required to maintain the temperature inside the substation equiped with Transformer) complete all as specified and directed.
92M&L for Preventive maintenance of DG sets (75kVA x 01, 62.5kVA x 1 ,125kVA x 01) on quarterly basis installed at NDC. The following maintenance to be carried out complete all as specified and directed as under:a) Checking levels of Oil in Fuel Tank Coolant, Gauge Valve and replenish if necessaryb) Re-grease all grease points c) Tightening of Nut-Bolts of pipeline of fuel oil, lubricating oil, water and check for any leakages.d) Check the Water level in Radiator and Top Up the coolant as requirede) Clean Oil Filters/Fuel Filters.f) Check Viscosity of Lube Oil.g) Check Crank case for leakage. h) Cleaning Air Filters.i) Check the Radiator fan belt condition.j) Check Distilled water for Battery and Top-up.k) Check Battery cover condition from cover and Battery Voltage.l) Check the Metering equipment.m) Check the Insulation resistance of alternator.
93M&L for \\"B\\" Check of DG set of 62.5 KVA capacity by taking out unsv spares, adjustment belt tension,Tuning of Engine, adjustment of speed, alternator voltage, check the serviceability of AVR, frequency etc, greasing oiling and changing oil, oil filter, fuel filter, bypass filter, Air filter, Water separator and Radiator cleaning with chemical For smooth functioning of DG Set complete all as specified and directed by Engg in charge.Note: Any spares, Engine oil, Coolant, Unserviceable spares required to be replaced shall be measured and paid separately under respective items
94All as per item No 92.00 above but for 75 kVA DG Set complete all as specified and directed.
95All as per item No 92.00 above but for 125 kVA DG Set complete all as specified and directed.
96M&L for Servicing of Generator AMF Panel of 62.5 KVA DG Set complete including labour for replacement of u/s spares, testing complete all as specified and directed.Note: unserviceable spares required to be replaced shall be measured paid for separately under respective items
97All as per item No 95.00 above but for 75 kVA DG Set complete all as specified and directed.
98All as per item No 95.00 above but for 125 kVA DG Set complete all as specified and directed.
99Supply only in replacement of Fan belt suitable for 62.5 KVA DG Set as per existing complete all as specified and directed by Engr-in-Charge.
100All as per item No 98.00 above but for 75 kVA DG Set complete all as specified and directed.
101All as per item No 98.00 above but for 125 kVA DG Set complete all as specified and directed.
102Supply only in replacement of Diesel Filter suitable for 62.5 KVA DG Set as per existing complete all as specified and directed by Engr-in-Charge.
103All as per item No 101.00 above but for 75 kVA DG Set complete all as specified and directed.
104All as per item No 101.00 above but for 125 kVA DG Set complete all as specified and directed.
105Supply only in replacement of Oil Filter suitable for 62.5 KVA DG Set as per existing complete all as specified and directed by Engr-in-Charge.
106All as per item No 104.00 above but for 75 kVA DG Set complete all as specified and directed.
107All as per item No 104.00 above but for 125 kVA DG Set complete all as specified and directed.
108Supply only in replacement of Air Filter suitable for 62.5 KVA of DG Set as per existing complete all as specified and directed by Engr-in-Charge.
109All as per item No 107.00 above but for 75 kVA DG Set complete all as specified and directed.
110All as per item No 107.00 above but for 125 kVA DG Set complete all as specified and directed.
111Supply only in replacement of Temperature Gauge suitable for 62.5 KVA DG Set as per complete all as specified and directed by Engr-in-Charge.
112All as per item No 110.00 above but for 75 kVA DG Set complete all as specified and directed.
113All as per item No 110.00 above but for 125 kVA DG Set complete all as specified and directed.
114Supply only in replacement of Lube Oil Pressure Gauge suitable for 62.5 KVA DG Set as per existing complete all as specified and directed by Engr-in-Charge.
115All as per item No 113.00 above but for 75 kVA DG Set complete all as specified and directed.
116All as per item No 113.00 above but for 125 kVA DG Set complete all as specified and directed.
117Supply only Coolant of approved make as per OEM in sealed containers complete all as specified and directed.
118Supply only Synthetic Engine Oil (Type : SAE 20W40) of approved make as per OEM in sealed containers complete all as specified and directed.
119M&L for as in repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing u/s parts re-assembling the pump after repair/ replacement of parts and testing by caliberation as per sample of Cap 62.5 - 125 kVA complete all as specified and directed.
120M&L for taking down and servicing of radiator assembly and replacement of minor parts, de-scaling of tubes with chemical solution, welding/brazing leak testing including transportation to workshop and re-fixing after repairs and testing commissioning for DG set 62.5 to 75 KVA capacity complete all as specified and directed by Engr-in-charge.
121All as per item No 119.00 above but for DG Set 125 kVA Capacity complete all as specified and directed.
122S&F in replacement of maintenance free Tubular Battery 12V, 150 AH with minimum 36 months warranty complete all as specified and directed by Engr-in-charge.
123S&F in replacement of Battery lead copper conductor of size 50 Sqmm multistranded PVC insulated with suitable terminals at both ends of required length for each battery complete all as specified and directed.
124M&L for repair of self starter with replacament of carbon bushes, pinion, rewinding of stator and rotor winding with approved quality of winding wire as per existing and replacement of defective parts to make the starter fully functional and commissioning and testing of DG set of any type and capacity complete all as specified and directed by Engr-in-Charge.
125S&F in repair Battery Lugs/Connectors of suitable capacity as per the site complete all as specified and directed by Engr-in-Charge.
126S&F in replacement of Hose Pipe Set suitable for 62.5 to 75 KVA DG sets complete all as specified and directed.
127All as per item No 125.00 above but for 125 kVA DG Set complete all as specified and directed.
128M&L as in repairs to DG Set Control Panel of capacity 62.5 - 75 kVA incl replacement defective sensors like AMF module, relay card/board, current transformer, Key switch , Indicators, Warning, Push button and checking control wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge
129M&L as in repairs to DG Set Control Panel of capacity 125 kVA incl replacement defective sensors like AMF module, relay card/board, current transformer, Key switch , Indicators, Warning, Push button and checking control wiring complete including made functional all the system/controls complete all as specified and directed by Engineer in charge.
130S&F in replacement of Battery Charger of 6 Amps rating 12V Battery complete all as specified by directed by Engr-in-Charge.
131Supply, installation, testing and commissioning in replacement of 200 Amp, four pole on load changeover in the existing enclosure with proper grouting of the same on walls with fastners complete all as specified and directed by Engr-in-Charge.
132S&F in replacement of LED Street light fitting 45 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed.Make : Havells/CG/Philips.
133S&F in replacement of LED Street light fitting 60 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unservicable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastner washer etc complete all as specified and directed.Make : Havells/CG/Philips.
134M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover etc. including taking down old unsv earthing any type complete all as specified and directed.
135S&F in repair Earth continuity conducto of size 25x4 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
136S&F in replacement power capacitor 3 phase 25 kVAR of rated current 32.8 amp complete all as specified and directed by Engr-in-Charge
137S&F in replacement MCCB 4-Pole, 415 V, adjustable type 63 Amps with breaking capacity 16 kA complete all as specified and directed.
138S&F in replacement MCCB 4-Pole, 415 V, adjustable type 100 Amps with breaking capacity 36 kA complete all as specified and directed.
139S&F in replacement MCCB 4-Pole, 415 V, adjustable type 160 Amps with breaking capacity 36 kA complete all as specified and directed.
140S&F in replacement MCCB 4-Pole, 415 V, adjustable type 200 Amps with breaking capacity 36 kA complete all as specified and directed.
141S&F in replacement MCCB 4-Pole, 415 V, adjustable type 250 Amps with breaking capacity 36 kA complete all as specified and directed.
142S&F in replacement MCCB 4-Pole, 415 V, adjustable type 400 Amps with breaking capacity 36 kA complete all as specified and directed.
143M&L for servicing and calibration of APFC relay panel of capacity 275 KVAR including replacement of minor faults, push button switch, wiring etc complete in all respect as per the direction of Engr-in-charge.
144S&F in repair of aluminium lugs of size 16/25 sq mm complete all as specified and directed by Engr-in-Charge
145S&F in repair of aluminium lugs of size 35/50sq mm complete all as specified and directed by Engr-in-Charge
146S&F in repair of aluminium lugs of size 70/95 sq mm complete all as specified and directed by Engr-in-Charge
147S&F in repair of aluminium lugs of size 120/150 sq mm complete all as specified and directed by Engr-in-Charge
148S&F Current transformer of 60:30/5+5 fixed in ACB panel of protection class 5P10 & metering clss -01 completeincluding taking out old u/s complete all as specified and directed by Engr-in-Charge
149M&L for servicing servo voltage stablizer 200 KVA including replacement of minor complete in all respect as per the direction of Engr-in-charge.
150M&L for disconnecting power supply from Air Circuit Breaker of capacity 630 Amps, taking out trolley unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part ,tightening/cleaning of CTs, cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley , checking proper operation of trolley all as directed, inserting trolley inside and testing, and putting on load complete all as specified and directed.
151S&F in repair Cable jointing kit for 1100 volt complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm complete all as specified and directed by Engr-in-Charge
152S&F in repair Cable jointing kit for 1100 volt complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed by Engr-in-Charge
153S&F in repair Cable jointing kit for 1100 volt complete with jointing material andaccessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
154S&F wire meshed Hot dip Galvanized cable tray 54mm (h) x 200 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends.for mounting and supporting the cable tray system, along with vertical bends, bends. including taking down and re fixing any type of electric cable,LAN /signal cable ,if require through wall cutting and making to good surface in distrubed area including taking out old u/s complete all as specified and directed by Engr-in-Charge
155M&L for 120 Sqmm, 3.5 core cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor including laying/fixing on wall/ floor with clip and trunch complete with thimbles including taking out old unsv cable complete all as specified and directed by Engr-in-Charge.
156All as per item No 154.00 above but for size 95 Sqmm 3.5 Core complete all as specified and directed.
157All as per item No 154.00 above but for size 70 Sqmm 3.5 Core complete all as specified and directed.
158All as per item No 154.00 above but for size 50 Sqmm 3.5 Core complete all as specified and directed.
159All as per item No 154.00 above but for size 35 Sqmm 3.5 Core complete all as specified and directed.
160All as per item No 154.00 above but for size 25 Sqmm 3.5 Core complete all as specified and directed.
161M&L preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with two coats of Aluminium paint upto 9 mtr long (410 SP-31) and exposed surface of Pole yellow and black paint in strips alternative 30 cm wide ipto 1.5 mtr from ground level including marking of pole No's with paint complete all as specified and directed.
162S&F in replacement LED inverter based 60 watt building security(street light) fitting complete with accessories made of aluminum housing having minimum system efficiency 100 lm/watt operating at full load at AC supply & minimum 20 watt during battery back up , power fractor is equal to or greater 0.95, CCT 6500K, CRI -80, IP-20, inbuilt Li-ion battery for backup, back up to 4 Hrs for complete all as specified and directed.Note:(a) Srl Item No 02.00, 04.00, 07.00, 09.00, 11.00 to 15.00, 21.00, 22.00, 31.00 to 38.00, 48.00, 53.00, 55.00, 56.00, 70.00, 71.00, 130.00 to 133.00, 153.00 to 159.00 & 161.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56256114
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Internal Electrification Including Lt Panels And Xlpe Cables, Repair/ Maintenance Of Cooling Appliances Such As Water Cooler, Refrigerator And Acs At Ahq C Lodhi Road & Echs Polyclinic Lodhi Road And Repair/ Maintenance Of Dg Sets, Lt Panel, Lt Ug Cables, Security Lights & Related Works At Ndc Under Ge New Delhi
Basic Detail
Tender No NIT No GE/ND-39/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 20 Jul 2026
Submission Date 27 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 68220
Exemption Available
Document List
ac46aaf5-9ab4-4930-8e80-d891fde6ccaa.html
BOQ_868557.xls
Tender39.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

ac46aaf5-9ab4-4930-8e80-d891fde6ccaa.html

xls

BOQ_868557.xls

pdf

Tender39.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders