Tender For Repair To Water Proofing Treatment For Reinforced Cement Concrete Roof And Repair To Chajja/ Parapet, Water Tank, Gi Tubing And Rain Water Pipe In Technical Area At Af Stn Nal Under Ge (Af) Nal
Tender Value
40 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
19 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Water Proofing Treatment For Reinforced Cement Concrete Roof And Repair To Chajja/ Parapet, Water Tank, Gi Tubing And Rain Water Pipe In Technical Area At Af Stn Nal Under Ge (Af) Nal
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement Concrete of any description and in any position including any type of rooftreatment , PCC padding, lime concrete, mud etc, complete all as specified and directed. Note: All demolished material / debries will be disposed off out side the Airforce station Nal with out any extra cost to the govt. Contractor should arrange dumping site to dispose off material. |
| 2 | M&L for cutting grooves in brick wall for inserting APP membrane and other works size of grooves 75mm wide and 65mm deep and shapping horizontal face of grooves and making good with cement mortar 1:3 or PCC 1:2:4 complete all as specified and directed. |
| 3 | M&L for cement concrete 1:2:4 type B0,(using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, on junction of parapet, coping etc cement concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 4 | M&L for cement concrete 1:3:6 type C1, (using 20 mm graded stone aggregate) as in roof paddding, mass concrete finishing as required gradient cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 5 | M & L for APP based polymeric membrane minium weight 3 Kg/Sqm and minium 3 mm thick, reinforced with polyster non wove fabric (wt. not less than 150 gms/Sqm ) laid by torch forced application over and including a priming coat using bituminious primer @ 0.40litre/ sqm as per manufactures instruction on concrete surface complete all as specified and directed by Engineer- in-charge. |
| 6 | M & L for two coats of of oil based aluminium heat resisting Paint on App membrane surface of approved make complete all as specified and as directed by Engineer-in-charge. |
| 7 | M&L for 15mm thick plaster in cement mortar 1:4 mixed with water proofing compound pidi proof LW @ 200ml per 50Kg cement as per manufacturers instructions on concrete surface of roof and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge Note:- WPC shall be measured and paid separately |
| 8 | M&L for 20 for mm thick pre-cast cement concrete tiles using 1:2:4 type B0(using 12.5mmgraded stone aggregate) set jointed and pointed in Cm 1:3 over and including 15 mm thick screed bed in cm 1:6 complete all as specified and directed by Engineer-in-Charge |
| 9 | Supply only Liquid water proofing compound ISI marked complete all as specified and directed. |
| 10 | Taking up or down 15 mm dia steel tubing & connections including clearing for refixing or removal to store complete all as specified and directed. |
| 11 | Taking up or down 20 mm dia steel tubing & connections including clearing for refixing or removal to store complete all as specified and directed. |
| 12 | S & F 15mm bore of tube medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed. |
| 13 | S & F 20mm bore of tube medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed. |
| 14 | Refixing old steel tubing 15mm bore and connections in new or old position complete all as specified and directed. |
| 15 | Refixing old steel tubing 20mm bore and connections in new or old position complete all as specified and directed. |
| 16 | M & L for disconnecting existing tanks, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt from RCC / PVC tank capacity of tanks exc. 250 ltrs and up to 500 ltrs by emptying, drying, cleaning with chlorine/washing powder by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 17 | M&L for disconnecting existing tanks, setting aside (or lowering if required) for repairs, Cleaning and removing all scale and dirt from RCC / PVC tank capacity of tanks exc. 500 ltrs and up to 1000 ltrs by emptying, drying, cleaning with chlorine/washing powder by scrubbing the dust with wire brush from tank by removing inlet and outlet pipe and refixing inlet and outlet pipe, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. |
| 18 | M&L for dismantling water tanks any type of capacity exc 250 but n.exc 500 liters complete all as specified and directed. |
| 19 | M&L for dismantling water tanks any type of capacity exc 500 but n.exc 1000 liters complete all as specified and directed. |
| 20 | S&F 500 litre capacity rotational moulded polyethylene water storage tank, white colour, triple layers, conforming to IS, cylindrical vertical with closed top, hoisted and fixed in position complete all as specified and as directed. |
| 21 | S&F 1000 litre capacity Rotational moulded polyethylene water storage tank, white colour, triple layers, conforming to IS, cylindrical vertical with closed top, hoisted and fixed in position complete all as specified and as directed. |
| 22 | Supply and fixed 20 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. |
| 23 | Re- fixing only 20 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. |
| 24 | S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 25 | Re- fixing only 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.\\" |
| 26 | Demolition of brick work or stone masonary, built in cement mortar or cement lime mortar including all quions,arches, pillars, ec, but excluding aslar facings,dresse stone work and percast conrete articles complete all as specified and directed. |
| 27 | M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6 m mean redius, built in cement mortar 1:6 complete all as specified and directed |
| 28 | All as per item No 27.00 as above but except bricks |
| 29 | M & L half Brick wall with sub-class 'B' bricks old size straight or curved on plan to any radius built in cement mortar 1:4 and complete all as specified and directed. |
| 30 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed |
| 31 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore including necessary clumping complete all as specified and directed |
| 32 | Refixing only 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary clumping complete all as specified and directed |
| 33 | S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed |
| 34 | Taking down cement plaster on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 35 | M & L for 15 mm thick rendering in cement mortar 1:4 surface to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 36 | M&L for Rendering 15mm thick in cement mortar 1:6 on brick work or concrete surface and finished even and smooth without using extra cement and complete all as specified and directed. |
| 37 | M&L for Rendering 10mm thick in CM 1:3 over concrete surface as on ceiling finish even and smooth w/o using extra cement, complete all as specified and directed. |
| 38 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bond distemper over a coat of alkali-resiatant priming paint on plastered surrface complete all as specified and directed |
| 39 | M & L for three coat of white wash on new surface of ceiling including preparation complete all as specified and directed |
| 40 | Preparing surface of new plastered surface and applying two coats of acrylic emulsion extterior paint over coat of primer, tint as approved by Garrison Engineer in any pettern to match existing surface complete all as specified and directed. |
| 41 | M & L for repair to RCC Chajjas, roof projection edges, hanging part of chajjas, edges of chajjas, RCC papafeets, under the roof / floor slabs with PCC 1:2:4 (using 12.5mm crushed graded agg) including necessary renforcement 8mm to 12mm TMT bars, form work, MS wire mesh for bounding the concrete on ground required and plaster work in CM 1:3 & periodical services to match with the existing surfaces finishing at any height of buildings etc complete all as specified and directed by Engineer-in-Charge. M&L for disconnecting from the existing location cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including taking out existing cable of any size. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender