Power Government Departments Closing in 4 days TDR #56255755

Tender For Rewiring Works In Type -I (64 Qtrs) At Amd Residential Complex, Amd, Central Region, Nagpur

Issued by Government Departments · Nagpur, Maharashtra
Tender Value
55.45 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
4 days left
EMD
1.10 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Rewiring Works In Type -I (64 Qtrs) At Amd Residential Complex, Amd, Central Region, Nagpur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Jul-2026 Extension of last date of site inspection Other 27-Jul-2026

BOQ

Name of Work:- Rewiring works in Type –I (64 Qtrs) at AMD Residential Complex, AMD, Central Region, Nagpur
Sl. No. Item Description
1Notes:1. Before quoting, the bidder shall visit the site and make himself familiar with the site, nature, conditions and quantum / scope of work involved. You may contact Incharge, Engineering Services, AMD CR (Contact No:07122565545-210/106) for site visit.2. The rates quoted shall include cost of all materials, labour, loading charges, unloading charges, transportation, hoisting, tools, tackles including testing charges, all taxes (except EPF &ESI) and other charges if any. No extra payment over and above the rate quoted shall be made to the contractor in this respect. 3. The workers employed for the work shall strictly follow all safety measures as stated in safety code of this tender and also as per DAE safety code.4.The Contractor shall adhere to the provisions of applicable labour laws such as Contract Labour (Regulation & Abolition) Act, 1970, Minimum Wages Act, 1948, Employees State Insurance Act, Equal Remuneration Act, 1970 and rules made there under. 5.Contractor has to pay minimum wages, EPF & ESI to the manpower deployed for the work as per state/ central government orders issued from time to time. The actual amount paid towards EPF & ESI shall be reimbursed to him by the Department after satisfying that it has been actually and genuinely paid by the contractor. The bidder should not consider EPF & ESIC in his rates.6. The contractor shall ensure that all the persons executing the electricalwork have valid electrical license. 7. New wiring shall be concealed (recessed) conduit wiring and includes wall chasing, fixing of conduits, GI boxes and DBs, wiring, making good with cement concrete, plastering, and painting to restore the original wall finish.8. As the work required to be executed in occupied residential flats, there should be minimum inconvenience to the Occupants. The work shall be programmed in consultation with the Occupants & Engineer-in-charge. If so required, the work may have to be done even before and after office hours. No compensation shall be paid for loss of labour due to unavailability of flats/ site in any circumstances.
2Supplying and fixing 12 way , Double door, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) as per direction and instruction of Engineer In-Charge.
3Supplying and fixing 63 A, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. as per direction and instruction of Engineer In-Charge.
4Supplying and fixing Single pole, 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. as per direction and instruction of Engineer In-Charge.
5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.as per direction and instruction of Engineer In-Charge.
63 Module (100 mm X 75 mm)
76 Module (200mm X 75mm)
8Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per direction and instruction of Engineer In-Charge.
95/6 A switch
103 pin 5/6 A socket outlet
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required as per direction and instruction of Engineer In-Charge.
12Wiring for GROUP-A light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessedmedium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.per direction and instruction of Engineer In-Charge.
13Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required as per direction and instruction of Engineer In-Charge.
14Supplying and fixing suitable size GI box with modular plate cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 modular SP MCB ,\\"C\\" curve including connections ,painting etc.as required as per direction and instruction of Engineer In-Charge.
15Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required as per direction and instruction of Engineer In-Charge.
162 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
172 X 4 sq. mm + 1 X 4 sq. mm earth wire
182 X 6 sq. mm + 1 X 6 sq. mm earth wire
19Removal of existing wiring in flats & corridors including removal of DB, Main wiring, Switch boards, socket outlets, circuit/ point wiring, call bells etc (excluding Ceiling fans & exhaust fans) after disconnection of mains and earth connections etc complete. The recess area of DB/ electrical boxes/ switch boards if any available after installing new DB/ switch boards is to be filled with cement concrete, necessary plastering & painting is to be done so as to match with the adjoining areas of wall on all sides, making the good, segregating and stacking the old removed items, including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C.
20Supply & installation of 225 mm exhaust fan in bathroom/ toilet including making provision for installation by cutting the wall in required size & plastering neatly to obtain the shape or making suitable modification in the existing wooden ventilator for fixing of exhaust fan etc complete including disposal of debris with in a lead of 50 meters as per the instruction & direction of E-I-C.
21Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required as per direction and instruction of Engineer In-Charge.
22Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate , suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required as per direction and instruction of Engineer In-Charge.
23Supplying and fixing modular blanking plate on existing modular plate and switch box excluding modular plate as required
24Supply & installation of 20W (approx) LED T5 light, 4 feet, cool day light, 2000lm (min), luminous efficacy > 100 complete with all accessories on the wall/ ceiling including connections, earthing etc. as per the instruction and direction of E-I-C.
25Supply & installation of 20W (approx) LED T5 light with battery/invertor for back up during power failure , 4 feet, cool day light, 2000lm (min), luminous efficacy > 100 complete with all accessories on the wall/ ceiling including connections, earthing etc. as per the instruction and direction of E-I-C. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56255755
AUTHORITY Government Departments
TENDER VALUE 55.45 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Atomic Minerals Directorate For Exploration And Research
Work Description Tender for Rewiring Works In Type -I (64 Qtrs) At Amd Residential Complex, Amd, Central Region, Nagpur
Basic Detail
Tender No AMD/CESG/CR/ET-146/2026-27
Bidding Type Tender
Location
City Nagpur
State Maharashtra
Key Dates
Publish Date 15 Jul 2026
Submission Date 27 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 55.45 Lakhs
Tender Fee Ref. Documents
EMD 1.10 Lakhs
Exemption Not Available
Document List
374d0a17-c3dc-4351-8390-b095fce951a4.html
BOQ_961886.xls
Detailedtechnicalspecs.pdf
GCC.pdf
Preamble.pdf
Techforms.xls
Tendernotice_1 (1).pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

374d0a17-c3dc-4351-8390-b095fce951a4.html

xls

BOQ_961886.xls

pdf

Detailedtechnicalspecs.pdf

pdf

GCC.pdf

pdf

Preamble.pdf

xls

Techforms.xls

pdf

Tendernotice_1 (1).pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders