Tender For Rewiring Works In Type -I (64 Qtrs) At Amd Residential Complex, Amd, Central Region, Nagpur
Tender Value
55.45 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
4 days left
EMD
1.10 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rewiring Works In Type -I (64 Qtrs) At Amd Residential Complex, Amd, Central Region, Nagpur
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Jul-2026 | Extension of last date of site inspection | Other | 27-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Notes:1. Before quoting, the bidder shall visit the site and make himself familiar with the site, nature, conditions and quantum / scope of work involved. You may contact Incharge, Engineering Services, AMD CR (Contact No:07122565545-210/106) for site visit.2. The rates quoted shall include cost of all materials, labour, loading charges, unloading charges, transportation, hoisting, tools, tackles including testing charges, all taxes (except EPF &ESI) and other charges if any. No extra payment over and above the rate quoted shall be made to the contractor in this respect. 3. The workers employed for the work shall strictly follow all safety measures as stated in safety code of this tender and also as per DAE safety code.4.The Contractor shall adhere to the provisions of applicable labour laws such as Contract Labour (Regulation & Abolition) Act, 1970, Minimum Wages Act, 1948, Employees State Insurance Act, Equal Remuneration Act, 1970 and rules made there under. 5.Contractor has to pay minimum wages, EPF & ESI to the manpower deployed for the work as per state/ central government orders issued from time to time. The actual amount paid towards EPF & ESI shall be reimbursed to him by the Department after satisfying that it has been actually and genuinely paid by the contractor. The bidder should not consider EPF & ESIC in his rates.6. The contractor shall ensure that all the persons executing the electricalwork have valid electrical license. 7. New wiring shall be concealed (recessed) conduit wiring and includes wall chasing, fixing of conduits, GI boxes and DBs, wiring, making good with cement concrete, plastering, and painting to restore the original wall finish.8. As the work required to be executed in occupied residential flats, there should be minimum inconvenience to the Occupants. The work shall be programmed in consultation with the Occupants & Engineer-in-charge. If so required, the work may have to be done even before and after office hours. No compensation shall be paid for loss of labour due to unavailability of flats/ site in any circumstances. |
| 2 | Supplying and fixing 12 way , Double door, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) as per direction and instruction of Engineer In-Charge. |
| 3 | Supplying and fixing 63 A, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. as per direction and instruction of Engineer In-Charge. |
| 4 | Supplying and fixing Single pole, 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. as per direction and instruction of Engineer In-Charge. |
| 5 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.as per direction and instruction of Engineer In-Charge. |
| 6 | 3 Module (100 mm X 75 mm) |
| 7 | 6 Module (200mm X 75mm) |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per direction and instruction of Engineer In-Charge. |
| 9 | 5/6 A switch |
| 10 | 3 pin 5/6 A socket outlet |
| 11 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required as per direction and instruction of Engineer In-Charge. |
| 12 | Wiring for GROUP-A light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessedmedium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.per direction and instruction of Engineer In-Charge. |
| 13 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required as per direction and instruction of Engineer In-Charge. |
| 14 | Supplying and fixing suitable size GI box with modular plate cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 modular SP MCB ,\\"C\\" curve including connections ,painting etc.as required as per direction and instruction of Engineer In-Charge. |
| 15 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required as per direction and instruction of Engineer In-Charge. |
| 16 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 17 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 18 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 19 | Removal of existing wiring in flats & corridors including removal of DB, Main wiring, Switch boards, socket outlets, circuit/ point wiring, call bells etc (excluding Ceiling fans & exhaust fans) after disconnection of mains and earth connections etc complete. The recess area of DB/ electrical boxes/ switch boards if any available after installing new DB/ switch boards is to be filled with cement concrete, necessary plastering & painting is to be done so as to match with the adjoining areas of wall on all sides, making the good, segregating and stacking the old removed items, including cost of materials, labour, tool & plants, taxes etc as per the instructions and directions of E-I-C. |
| 20 | Supply & installation of 225 mm exhaust fan in bathroom/ toilet including making provision for installation by cutting the wall in required size & plastering neatly to obtain the shape or making suitable modification in the existing wooden ventilator for fixing of exhaust fan etc complete including disposal of debris with in a lead of 50 meters as per the instruction & direction of E-I-C. |
| 21 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required as per direction and instruction of Engineer In-Charge. |
| 22 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate , suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required as per direction and instruction of Engineer In-Charge. |
| 23 | Supplying and fixing modular blanking plate on existing modular plate and switch box excluding modular plate as required |
| 24 | Supply & installation of 20W (approx) LED T5 light, 4 feet, cool day light, 2000lm (min), luminous efficacy > 100 complete with all accessories on the wall/ ceiling including connections, earthing etc. as per the instruction and direction of E-I-C. |
| 25 | Supply & installation of 20W (approx) LED T5 light with battery/invertor for back up during power failure , 4 feet, cool day light, 2000lm (min), luminous efficacy > 100 complete with all accessories on the wall/ ceiling including connections, earthing etc. as per the instruction and direction of E-I-C. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Jul 27, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysJul 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer