Power Government Departments Closing in 10 days TDR #56253704

Bids Are invited for Custom Bid For Services - Increasing Capacity Fo 16Kva To 25Kva Distribution Transformers And 100Kva To 250Kva Distribution Transformer On Semi Turnkey Basis In Business Plan 2026-27 Under The Area Of Edd Bah Agra - Carriage Of F

Issued by Government Departments · Agra, Uttar Pradesh
Tender Value
15 Lakhs
Estimated cost
Bid Submission
16 Jul 2026
10 days left
EMD
15000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Bids Are invited for Custom Bid For Services - Increasing Capacity Fo 16Kva To 25Kva Distribution Transformers And 100Kva To 250Kva Distribution Transformer On Semi Turnkey Basis In Business Plan 2026-27 Under The Area Of Edd Bah Agra - Carriage Of Following From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) A) Pcc Pole 8.5/9 Mtr. Long , Carriage Of Following From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) B) 25Kva T/F , Carriage Of Following From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) C) 250 Kva T/F , Carriage Of Following From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) I) Lt Xlpe Cable Al 3.5X150/70/240/400 Sqmm, Lt Pvc Cable (20 Mtr), Lt Xlpe Cable 1*400Sqmm (60 Mtr) , Lt Xlpe Cable 1*150Sqmm (200 Mtr) , Carriage Of Following Material From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) J) Line Material Viz. Abc 3X50 Sqmm(4130Mtr) / Weasal Conductor (50Mtr), Stay Set (38 Nos), 11 Kv Fuse Set (14 Nos), Tpmo (7 Nos), Cross Arm, Angle, Pin Insulators (54 Nos), Disk Insulators (57 Nos) And Other Line Material, If Required, Earthing Complete (38 Nos) , Erection And Grouting In 1:2:4 Ratio (Cement, Sand And Bricks Balast) Single Pole On 8.5 Mtr. Long Pcc Poles Including Fixing Of All Accessories For 11 Kv/Lt Line As Per Respo Norms Labour, T &P And Carrier, Grouting Material Etc. Required For Proper Completion Of Work Shall Be Done By The Contractor At His Own Cost. , Erection And Grouting In 1:2:4 Ratio (Cement, Sand And Bricks Balast) Double Pole On 8.5 Mtr. Long Pcc Poles Including Fixing Of All Accessories For 11 Kv/Lt Line As Per Respo Norms Labour, T &P And Carrier, Grouting Material Etc. Required For Proper Completion Of Work Shall Be Done By The Contractor At His Own Cost. , Fixing Of Earthing Complete As Per Respo Norms Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. , Laying Sagging Stringing And Binding And Jumpering Of Conductor In Lt Line As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carrier Etc Reauired For Proper Completion Of Work. A) Acsr Weasal Conductor , Laying Sagging Stringing And Binding And Jumpering Of Conductor In Lt Line As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carrier Etc Reauired For Proper Completion Of Work. C) Abc 3X50sqmm , Construction Of Plinth For 250 Kva Transformer Of Size 5X5x4 Above The Ground Lable And 1 Feet Below The Ground. At The Bottom There Shall Be Cc Pad Of Brick Ballast Of Size 5X5x3 Thick In Ratio 1:3:6 [Cement, Sand And Brick Ballast]. The First Class Brick Wall Work Shall Be 9 Thick In Ratio 1:4 [Cement And Sand]. The Hollow Portion Among The Wall Shall Be Filled Up With The Brick Ballast. On The Top Of The Wall Of Plint There Shall Be Rcc Work In Ratio 1:3:6 [Cement, Sand And Grit Stone] By Using 12 Mm Dai Ms Bar At Distance Of 9. There Shall Be Plastering All Over The Plinth 12 Mm Thick In Ratio 1:4 [Cement And Sand] Above The Ground Level. Proper Watering And Curing Of The Plinth Shall Be Carried Out As Per Direction Of Supervising Engineer. , Fencing Of 250 Kva T/Fs As Per Following Specification -Fabrication Of 50X50x6 Mm Size Ms Angle Frame Of Size 3000X2400mm With 450 Mm Long Angle For Grouting The Frame And Fixing Of 2X1.5, 10 Swg Welded Wire Mesh With Ms Strip Of 24X5mm Size All Round The Frame And Drilling 9 Mm Holes Insides Of Frames At As Distance Of 300Mm For Jointing Of Frame With The Help Of Boslts And Nuts Including Cost Of Material. The Width Of Panal May Vary As Per Site Conditions, Grouting And Fixing Of Angle Iron Frames In Ratio 1:2:4 (Cement, Coarse Sand And Stone Ballast ) In The Pocket Of 150X150x150mm All Round The Plinth And Bolting Of Frames With 25X8 Mm Size Bolts And Nuts, Making Main Gate In Front Of The Plinth Of Size 3000X2400 Mm By Making Two Leaves Of Size 3000X1200mm Size And Grouting The Same In Ratio And Method Mentioned At Item (B) Above Fixing With Hinges With Dandlas For Locking System & Painting Of Entire Wire Mesh Angle Iron Etc. With Bus Green Super Enamelled Pain In Two Coats On The Primer Two Coats Of Red Oxide. , Earthing Of 250 Kva Distribution Transformer By Maintenance Free Earthing Electrods (Chemical) By Digging Pits 6 Dia 3Mtr. Deep Including Inserting Pipe In Pipe Technology Concept Involve Two Mild Steel Pipes One Inserted Inside The Other Of Size ;- 1. Inner Pip Dia Meter 50 Mm. 2. Outer Pipe Dia Meter 100 Mm. Length Of The Both Pipe Shall Be 3000 Mm. The M.S.Pipe Shall Be Isi Mark Of Class B As Per Is 1239. Thickness Of The Pipe Shall Be 12 Swg. The Empty Space In The Pipe Shall Be Filled With The Specially Developed Crystalline Material Conductiv Mixture Such As Copper And Aluminimum Powder.Conductive Carbon And Bonding Material Etc. Mixed In Diffrent Proportions. Conductive Mixture Contents Shall Be 70 % Carbon Powder & 30% Metal Powder Preferably Pure Copper Or Aluminum Material Along With The Required Quantity Of Bonding Materials. Granule Size Of The Carbon & Metal Powder Shall Be 100 Mesh. The Mixture If Forced (Pressurized) Inside The Earth Electrode In Empty Space Of Inner Pipe & In Empty Space Between The Inner & Outer Pipe Of The Earth Electrode, In Paste Form And After Soldification Of The Same The Bottom End Cap As Well As Top End Cap Is Provided. The Mixture Shall Be Pressed By Machine In The Pipe. Precaution Shall Be Taken Has To Have No Air Gap Inside The Pipe While Pressing. The Back Fill Compound (Earth Enhancment Material ) Shall Be Superior Conductive Material That Improves Earthing Effectiveness Especially In Areas Of Poor Conductivity Such As Rocky Ground, Sandy Soil & Areas Of Moisture Varation. It May Contain Conductive Cement (20%) Graphite Carbon Powder(50%), Hydrous Aluminum Siliacate (10%), Sodium Montmorillonite (20%) Etc. It Shall Be Placed Around Earth Electrode In The Earth Pit To Improve The Conductive Of Earth Electrode & Ground Contact Area. Mild Steel Electro Galavanized Flat 50X6 Mm Shall Welded To Earth Electrode Pips & Connected With Trasnformer Neutral And Body As Below With The Hlep Of Steel Nut & Bolt Or Through Welding As Per Requirment Of Site, To Gi Pipe And Filling Of Chemical Mixutre Around The Gi Pipe Upto 3 Mtr. Including Making Of Chamber & Connecting The Top Of The Inserted Pipe With Transformer Body & Neutral Through M.S.Flat 50X6mm With The Help Of Nut & Bolt Or Through Welding And Making A Main Hole Of Size 2×2 And Covering The Same By A Stone Pad For The Purpose Of Poring Water For Moisture. , Mounting Of Following T/F On Existing Double Pole/Single Pole & Making Ht/Lt Connection C) 25Kva T/F. , Fixing Of Distribution Box With Cl On Errected Pole For Giving Supply To Consumer By Connecting Consumer Cables. , Installation For 250 Kva T/F On Plinth In Proper Alignment Direction & Making Ht/Lt Connection All Cost Of Labour And T&P Which Required For Completion Of Work. , Laying Of Lt Xlpe Cable Al 3.5X150/70/240/400 Sqmm Overhead Cable With Making Loop Complete Work As Per Respo Norms And Direction By Supervising Engineer. , Laying Of Lt Xlpe Cable 1*400/150Sqmm, , Laying Of Lt Pvc Cable , Installation Of Stay Set As Direction By Supervising Engineer. , Installation Of Tpmo As Direction By Supervising Engineer. , Installation Of D.O. Fuse Set On Double Pole , Concreating Of Pole As Per Respo Norms As Direction By Supervising Engineer. , Providing & Fixing Ms Top Channel 125X65x2240mm , Providing & Fixing Of Stone Pad , Providing & Fixing Dropper Channel 100X50x2028mm , Providing & Fixing Ms Angle 75X75x6x2228mm With Cl , Providing & Fixing Dp Cl , Providing & Fixing T Off Channel With Cl , Providing & Fixing Danger Board With Nut & Bolt , Providing & Fixing Lt Incoming Pannel , Providing & Fixing Suspension Cl With I Hook , Providing & Fixing Eye Hook , Providing & Fixing Dead And Cl , Providing & Fixing Db Cl , Providing & Installation Of Henley Type Tailless Unit Protection Cubical Panel 500 A 650 V For 250 Kva Dt , Providing & Fixing Nut & Bolt Off Size , Providing & Fixing Alu. Lug 400 Sqmm , Providing & Fixing Cooper T Piece 62*225*12 , Providing & Fixing Cooper T Piece , Dismentling & Removal Of 16 Kva T/F And Recived Back To Ele. Store Center Taj Agra , Dismentling & Removal Of 100 Kva T/F And Recived Back To Ele. Store Center Taj Agra

BOQ

Sl. No. Item TitleItem Description
1Carriage of following from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) A) PCC pole 8.5/9 Mtr. longCarriage of following from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) A) PCC pole 8.5/9 Mtr. long
2Carriage of following from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) B) 25KVA T/FCarriage of following from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) B) 25KVA T/F
3Carriage of following from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) C) 250 KVA T/FCarriage of following from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) C) 250 KVA T/F
4Carriage of following from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) I) LT XLPE CABLE AL 3.5X150/70/240/400 SQMM, LT PVC Cable (20 mtr), LT XLPE Cable 1*400SQMM (60 mtr) , LT XLPE Cable 1*150SQMM (200 mtr)Carriage of following from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) I) LT XLPE CABLE AL 3.5X150/70/240/400 SQMM, LT PVC Cable (20 mtr), LT XLPE Cable 1*400SQMM (60 mtr) , LT XLPE Cable 1*150SQMM (200 mtr)
5Carriage of following material from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) J) Line material viz. ABC 3X50 SQMM(4130MTR) / Weasal conductor (50mtr), stay set (38 nos), 11 kv Fuse set (14 nos), TPMO (7 nos), cross arm, angle, Pin insulators (54 nos), Disk insulators (57 nos) and other line material, if required, earthing complete (38 nos)Carriage of following material from Electricity Store CentreTajganj Agra to dump site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-100Kms.) J) Line material viz. ABC 3X50 SQMM(4130MTR) / Weasal conductor (50mtr), stay set (38 nos), 11 kv Fuse set (14 nos), TPMO (7 nos), cross arm, angle, Pin insulators (54 nos), Disk insulators (57 nos) and other line material, if required, earthing complete (38 nos)
6Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) single Pole on 8.5 Mtr. long PCC poles including fixing of all accessories for 11 KV/LT Line as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) single Pole on 8.5 Mtr. long PCC poles including fixing of all accessories for 11 KV/LT Line as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
7Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) Double Pole on 8.5 Mtr. long PCC poles including fixing of all accessories for 11 KV/LT Line as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) Double Pole on 8.5 Mtr. long PCC poles including fixing of all accessories for 11 KV/LT Line as per RESPO norms Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
8Fixing of earthing Complete as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.Fixing of earthing Complete as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.
9Laying sagging stringing and binding and jumpering of conductor in LT line as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc reauired for proper completion of work. a) ACSR Weasal conductorLaying sagging stringing and binding and jumpering of conductor in LT line as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc reauired for proper completion of work. a) ACSR Weasal conductor
10Laying sagging stringing and binding and jumpering of conductor in LT line as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc reauired for proper completion of work. C) ABC 3X50SQMMLaying sagging stringing and binding and jumpering of conductor in LT line as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc reauired for proper completion of work. C) ABC 3X50SQMM
11Construction of plinth for 250 KVA Transformer of size 5’x5’x4’ above the ground lable and 1 feet below the ground. At the bottom there shall be CC pad of brick ballast of size 5x5’x3” thick in ratio 1:3:6 [Cement, sand and brick ballast]. The first class brick wall work shall be 9” thick in ratio 1:4 [Cement and sand]. The hollow portion among the wall shall be filled up with the brick ballast. On the top of the wall of plint there shall be RCC work in ratio 1:3:6 [Cement, Sand and grit stone] by using 12 mm dai MS bar at distance of 9’’. There shall be plastering all over the plinth 12 mm thick in ratio 1:4 [Cement and sand] above the ground level. Proper watering and curing of the plinth shall be carried out as per direction of supervising engineer.Construction of plinth for 250 KVA Transformer of size 5’x5’x4’ above the ground lable and 1 feet below the ground. At the bottom there shall be CC pad of brick ballast of size 5x5’x3” thick in ratio 1:3:6 [Cement, sand and brick ballast]. The first class brick wall work shall be 9” thick in ratio 1:4 [Cement and sand]. The hollow portion among the wall shall be filled up with the brick ballast. On the top of the wall of plint there shall be RCC work in ratio 1:3:6 [Cement, Sand and grit stone] by using 12 mm dai MS bar at distance of 9’’. There shall be plastering all over the plinth 12 mm thick in ratio 1:4 [Cement and sand] above the ground level. Proper watering and curing of the plinth shall be carried out as per direction of supervising engineer.
12Fencing of 250 KVA T/Fs as per following specification -Fabrication of 50x50x6 mm size MS Angle frame of size 3000x2400mm with 450 mm long angle for grouting the frame and fixing of 2\\"x1.5\\", 10 SWG welded wire mesh with MS strip of 24x5mm size all round the frame and drilling 9 mm holes insides of frames at as distance of 300mm for jointing of frame with the help of boslts and nuts including cost of material. The width of panal may vary as per site conditions, Grouting and fixing of angle iron frames in ratio 1:2:4 (cement, coarse sand and stone ballast ) in the pocket of 150x150x150mm all round the plinth and bolting of frames with 25x8 mm size bolts and nuts, Making main gate in front of the plinth of size 3000x2400 mm by making two leaves of size 3000x1200mm size and grouting the same in ratio and method mentioned at item (b) above fixing with hinges with dandlas for locking system & Painting of entire wire mesh angle iron etc. with Bus Green super enamelled pain in two coats on the primer two coats of Red oxide.Fencing of 250 KVA T/Fs as per following specification -Fabrication of 50x50x6 mm size MS Angle frame of size 3000x2400mm with 450 mm long angle for grouting the frame and fixing of 2\\"x1.5\\", 10 SWG welded wire mesh with MS strip of 24x5mm size all round the frame and drilling 9 mm holes insides of frames at as distance of 300mm for jointing of frame with the help of boslts and nuts including cost of material. The width of panal may vary as per site conditions, Grouting and fixing of angle iron frames in ratio 1:2:4 (cement, coarse sand and stone ballast ) in the pocket of 150x150x150mm all round the plinth and bolting of frames with 25x8 mm size bolts and nuts, Making main gate in front of the plinth of size 3000x2400 mm by making two leaves of size 3000x1200mm size and grouting the same in ratio and method mentioned at item (b) above fixing with hinges with dandlas for locking system & Painting of entire wire mesh angle iron etc. with Bus Green super enamelled pain in two coats on the primer two coats of Red oxide.
13Earthing of 250 KVA distribution transformer by maintenance free Earthing Electrods (Chemical) by digging pits 6\\" dia 3mtr. deep including inserting pipe in pipe technology concept involve two mild steel pipes one inserted inside the other of size ;- 1. Inner pip dia meter 50 Mm. 2. outer pipe dia meter 100 mm. length of the both pipe shall be 3000 mm. The M.S.pipe shall be ISI mark of class B as per IS 1239. Thickness of the pipe shall be 12 swg. The empty space in the pipe shall be filled with the specially developed crystalline material conductiv mixture such as copper and aluminimum powder.conductive carbon and bonding material etc. mixed in diffrent proportions. Conductive mixture contents shall be 70 % carbon powder & 30% metal powder preferably pure copper or aluminum material along with the required quantity of bonding materials. Granule size of the carbon & metal powder shall be 100 mesh. The mixture if forced (pressurized) inside the earth electrode in empty space of inner pipe & in empty space between the inner & outer pipe of the earth electrode, in paste form and after soldification of the same the bottom end cap as well as top end cap is provided. The mixture shall be pressed by machine in the pipe. Precaution shall be taken has to have no air gap inside the pipe while pressing. The back fill compound (earth enhancment material ) shall be superior conductive material that improves earthing effectiveness especially in areas of poor conductivity such as rocky ground, sandy soil & areas of moisture varation. It may contain conductive cement (20%) graphite carbon powder(50%), hydrous aluminum siliacate (10%), Sodium montmorillonite (20%) etc. it shall be placed around earth electrode in the earth pit to improve the conductive of earth electrode & ground contact area. Mild steel electro galavanized Flat 50x6 mm shall welded to earth electrode pips & connected with Trasnformer neutral and body as below with the hlep of steel nut & bolt or through welding as per requirment of site, to GI pipe and filling of chemical mixutre around the GI pipe upto 3 mtr. including making of chamber & connecting the top of the inserted pipe with transformer body & neutral through M.S.flat 50x6mm with the help of nut & bolt or through welding and making a main hole of size 2'×2' and covering the same by a stone pad for the purpose of poring water for moisture.Earthing of 250 KVA distribution transformer by maintenance free Earthing Electrods (Chemical) by digging pits 6\\" dia 3mtr. deep including inserting pipe in pipe technology concept involve two mild steel pipes one inserted inside the other of size ;- 1. Inner pip dia meter 50 Mm. 2. outer pipe dia meter 100 mm. length of the both pipe shall be 3000 mm. The M.S.pipe shall be ISI mark of class B as per IS 1239. Thickness of the pipe shall be 12 swg. The empty space in the pipe shall be filled with the specially developed crystalline material conductiv mixture such as copper and aluminimum powder.conductive carbon and bonding material etc. mixed in diffrent proportions. Conductive mixture contents shall be 70 % carbon powder & 30% metal powder preferably pure copper or aluminum material along with the required quantity of bonding materials. Granule size of the carbon & metal powder shall be 100 mesh. The mixture if forced (pressurized) inside the earth electrode in empty space of inner pipe & in empty space between the inner & outer pipe of the earth electrode, in paste form and after soldification of the same the bottom end cap as well as top end cap is provided. The mixture shall be pressed by machine in the pipe. Precaution shall be taken has to have no air gap inside the pipe while pressing. The back fill compound (earth enhancment material ) shall be superior conductive material that improves earthing effectiveness especially in areas of poor conductivity such as rocky ground, sandy soil & areas of moisture varation. It may contain conductive cement (20%) graphite carbon powder(50%), hydrous aluminum siliacate (10%), Sodium montmorillonite (20%) etc. it shall be placed around earth electrode in the earth pit to improve the conductive of earth electrode & ground contact area. Mild steel electro galavanized Flat 50x6 mm shall welded to earth electrode pips & connected with Trasnformer neutral and body as below with the hlep of steel nut & bolt or through welding as per requirment of site, to GI pipe and filling of chemical mixutre around the GI pipe upto 3 mtr. including making of chamber & connecting the top of the inserted pipe with transformer body & neutral through M.S.flat 50x6mm with the help of nut & bolt or through welding and making a main hole of size 2'×2' and covering the same by a stone pad for the purpose of poring water for moisture.
14Mounting of following T/F on existing double pole/single pole & making HT/LT connection c) 25KVA T/F.Mounting of following T/F on existing double pole/single pole & making HT/LT connection c) 25KVA T/F.
15Fixing of DISTRIBUTION BOX with Clamp on Errected pole for giving supply to consumer by connecting consumer cables.Fixing of DISTRIBUTION BOX with Clamp on Errected pole for giving supply to consumer by connecting consumer cables.
16Installation for 250 KVA T/F on Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work.Installation for 250 KVA T/F on Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work.
17Laying of LT XLPE CABLE AL 3.5X150/70/240/400 SQMM overhead Cable with making loop complete work as per RESPO norms and direction by supervising Engineer.Laying of LT XLPE CABLE AL 3.5X150/70/240/400 SQMM overhead Cable with making loop complete work as per RESPO norms and direction by supervising Engineer.
18Laying of LT XLPE Cable 1*400/150SQMM,Laying of LT XLPE Cable 1*400/150SQMM,
19Laying of LT PVC CABLELaying of LT PVC CABLE
20Installation of Stay set as direction by supervising Engineer.Installation of Stay set as direction by supervising Engineer.
21Installation of TPMO as direction by supervising Engineer.Installation of TPMO as direction by supervising Engineer.
22Installation of D.O. Fuse set on Double poleInstallation of D.O. Fuse set on Double pole
23Concreating of Pole as per RESPO NORMS as direction by supervising Engineer.Concreating of Pole as per RESPO NORMS as direction by supervising Engineer.
24PROVIDING & FIXING MS TOP CHANNEL 125X65X2240MMPROVIDING & FIXING MS TOP CHANNEL 125X65X2240MM
25PROVIDING & FIXING OF Stone padPROVIDING & FIXING OF Stone pad
26PROVIDING & FIXING DROPPER CHANNEL 100X50X2028MMPROVIDING & FIXING DROPPER CHANNEL 100X50X2028MM
27PROVIDING & FIXING MS ANGLE 75X75X6X2228MM WITH CLAMPPROVIDING & FIXING MS ANGLE 75X75X6X2228MM WITH CLAMP
28PROVIDING & FIXING DP CLAMPPROVIDING & FIXING DP CLAMP
29PROVIDING & FIXING T OFF CHANNEL WITH CLAMPPROVIDING & FIXING T OFF CHANNEL WITH CLAMP
30PROVIDING & FIXING DANGER BOARD WITH NUT & BOLTPROVIDING & FIXING DANGER BOARD WITH NUT & BOLT
31PROVIDING & FIXING LT INCOMING PANNELPROVIDING & FIXING LT INCOMING PANNEL
32PROVIDING & FIXING SUSPENSION CLAMP WITH I HOOKPROVIDING & FIXING SUSPENSION CLAMP WITH I HOOK
33PROVIDING & FIXING EYE HOOKPROVIDING & FIXING EYE HOOK
34PROVIDING & FIXING DEAD AND CLAMPPROVIDING & FIXING DEAD AND CLAMP
35PROVIDING & FIXING DB CLAMPPROVIDING & FIXING DB CLAMP
36PROVIDING & Installation of Henley Type Tailless Unit Protection Cubical Panel 500 A 650 V FOR 250 KVA DTPROVIDING & Installation of Henley Type Tailless Unit Protection Cubical Panel 500 A 650 V FOR 250 KVA DT
37PROVIDING & FIXING Nut & Bolt Off SizePROVIDING & FIXING Nut & Bolt Off Size
38PROVIDING & FIXING Alu. Lug 400 SQMMPROVIDING & FIXING Alu. Lug 400 SQMM
39PROVIDING & FIXING Cooper T Piece 62*225*12PROVIDING & FIXING Cooper T Piece 62*225*12
40PROVIDING & FIXING Cooper T PiecePROVIDING & FIXING Cooper T Piece
41Dismentling & Removal of 16 KVA T/F and Recived back to ele. Store Center Taj AgraDismentling & Removal of 16 KVA T/F and Recived back to ele. Store Center Taj Agra
42Dismentling & Removal of 100 KVA T/F and Recived back to ele. Store Center Taj AgraDismentling & Removal of 100 KVA T/F and Recived back to ele. Store Center Taj Agra

AI Tender Summary

OUR REF NO 56253704
AUTHORITY Government Departments
TENDER VALUE 15 Lakhs
LAST DATE 16-07-2026
Authority
Authority Name Uttar Pradesh Power Corporation Limited
Work Description Bids Are invited for Custom Bid For Services - Increasing Capacity Fo 16Kva To 25Kva Distribution Transformers And 100Kva To 250Kva Distribution Transformer On Semi Turnkey Basis In Business Plan 2026-27 Under The Area Of Edd Bah Agra - Carriage Of Following From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) A) Pcc Pole 8.5/9 Mtr. Long , Carriage Of Following From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) B) 25Kva T/F , Carriage Of Following From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) C) 250 Kva T/F , Carriage Of Following From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) I) Lt Xlpe Cable Al 3.5X150/70/240/400 Sqmm, Lt Pvc Cable (20 Mtr), Lt Xlpe Cable 1*400Sqmm (60 Mtr) , Lt Xlpe Cable 1*150Sqmm (200 Mtr) , Carriage Of Following Material From Electricity Store Centretajganj Agra To Dump Site Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work.(Distance 00-100Kms.) J) Line Material Viz. Abc 3X50 Sqmm(4130Mtr) / Weasal Conductor (50Mtr), Stay Set (38 Nos), 11 Kv Fuse Set (14 Nos), Tpmo (7 Nos), Cross Arm, Angle, Pin Insulators (54 Nos), Disk Insulators (57 Nos) And Other Line Material, If Required, Earthing Complete (38 Nos) , Erection And Grouting In 1:2:4 Ratio (Cement, Sand And Bricks Balast) Single Pole On 8.5 Mtr. Long Pcc Poles Including Fixing Of All Accessories For 11 Kv/Lt Line As Per Respo Norms Labour, T &P And Carrier, Grouting Material Etc. Required For Proper Completion Of Work Shall Be Done By The Contractor At His Own Cost. , Erection And Grouting In 1:2:4 Ratio (Cement, Sand And Bricks Balast) Double Pole On 8.5 Mtr. Long Pcc Poles Including Fixing Of All Accessories For 11 Kv/Lt Line As Per Respo Norms Labour, T &P And Carrier, Grouting Material Etc. Required For Proper Completion Of Work Shall Be Done By The Contractor At His Own Cost. , Fixing Of Earthing Complete As Per Respo Norms Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. , Laying Sagging Stringing And Binding And Jumpering Of Conductor In Lt Line As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carrier Etc Reauired For Proper Completion Of Work. A) Acsr Weasal Conductor , Laying Sagging Stringing And Binding And Jumpering Of Conductor In Lt Line As Per Respo Manual And As Per Direction Of Supervising Engineer. It Includes The Cost Of Labour, T & P, Carrier Etc Reauired For Proper Completion Of Work. C) Abc 3X50sqmm , Construction Of Plinth For 250 Kva Transformer Of Size 5X5x4 Above The Ground Lable And 1 Feet Below The Ground. At The Bottom There Shall Be Cc Pad Of Brick Ballast Of Size 5X5x3 Thick In Ratio 1:3:6 [Cement, Sand And Brick Ballast]. The First Class Brick Wall Work Shall Be 9 Thick In Ratio 1:4 [Cement And Sand]. The Hollow Portion Among The Wall Shall Be Filled Up With The Brick Ballast. On The Top Of The Wall Of Plint There Shall Be Rcc Work In Ratio 1:3:6 [Cement, Sand And Grit Stone] By Using 12 Mm Dai Ms Bar At Distance Of 9. There Shall Be Plastering All Over The Plinth 12 Mm Thick In Ratio 1:4 [Cement And Sand] Above The Ground Level. Proper Watering And Curing Of The Plinth Shall Be Carried Out As Per Direction Of Supervising Engineer. , Fencing Of 250 Kva T/Fs As Per Following Specification -Fabrication Of 50X50x6 Mm Size Ms Angle Frame Of Size 3000X2400mm With 450 Mm Long Angle For Grouting The Frame And Fixing Of 2X1.5, 10 Swg Welded Wire Mesh With Ms Strip Of 24X5mm Size All Round The Frame And Drilling 9 Mm Holes Insides Of Frames At As Distance Of 300Mm For Jointing Of Frame With The Help Of Boslts And Nuts Including Cost Of Material. The Width Of Panal May Vary As Per Site Conditions, Grouting And Fixing Of Angle Iron Frames In Ratio 1:2:4 (Cement, Coarse Sand And Stone Ballast ) In The Pocket Of 150X150x150mm All Round The Plinth And Bolting Of Frames With 25X8 Mm Size Bolts And Nuts, Making Main Gate In Front Of The Plinth Of Size 3000X2400 Mm By Making Two Leaves Of Size 3000X1200mm Size And Grouting The Same In Ratio And Method Mentioned At Item (B) Above Fixing With Hinges With Dandlas For Locking System & Painting Of Entire Wire Mesh Angle Iron Etc. With Bus Green Super Enamelled Pain In Two Coats On The Primer Two Coats Of Red Oxide. , Earthing Of 250 Kva Distribution Transformer By Maintenance Free Earthing Electrods (Chemical) By Digging Pits 6 Dia 3Mtr. Deep Including Inserting Pipe In Pipe Technology Concept Involve Two Mild Steel Pipes One Inserted Inside The Other Of Size ;- 1. Inner Pip Dia Meter 50 Mm. 2. Outer Pipe Dia Meter 100 Mm. Length Of The Both Pipe Shall Be 3000 Mm. The M.S.Pipe Shall Be Isi Mark Of Class B As Per Is 1239. Thickness Of The Pipe Shall Be 12 Swg. The Empty Space In The Pipe Shall Be Filled With The Specially Developed Crystalline Material Conductiv Mixture Such As Copper And Aluminimum Powder.Conductive Carbon And Bonding Material Etc. Mixed In Diffrent Proportions. Conductive Mixture Contents Shall Be 70 % Carbon Powder & 30% Metal Powder Preferably Pure Copper Or Aluminum Material Along With The Required Quantity Of Bonding Materials. Granule Size Of The Carbon & Metal Powder Shall Be 100 Mesh. The Mixture If Forced (Pressurized) Inside The Earth Electrode In Empty Space Of Inner Pipe & In Empty Space Between The Inner & Outer Pipe Of The Earth Electrode, In Paste Form And After Soldification Of The Same The Bottom End Cap As Well As Top End Cap Is Provided. The Mixture Shall Be Pressed By Machine In The Pipe. Precaution Shall Be Taken Has To Have No Air Gap Inside The Pipe While Pressing. The Back Fill Compound (Earth Enhancment Material ) Shall Be Superior Conductive Material That Improves Earthing Effectiveness Especially In Areas Of Poor Conductivity Such As Rocky Ground, Sandy Soil & Areas Of Moisture Varation. It May Contain Conductive Cement (20%) Graphite Carbon Powder(50%), Hydrous Aluminum Siliacate (10%), Sodium Montmorillonite (20%) Etc. It Shall Be Placed Around Earth Electrode In The Earth Pit To Improve The Conductive Of Earth Electrode & Ground Contact Area. Mild Steel Electro Galavanized Flat 50X6 Mm Shall Welded To Earth Electrode Pips & Connected With Trasnformer Neutral And Body As Below With The Hlep Of Steel Nut & Bolt Or Through Welding As Per Requirment Of Site, To Gi Pipe And Filling Of Chemical Mixutre Around The Gi Pipe Upto 3 Mtr. Including Making Of Chamber & Connecting The Top Of The Inserted Pipe With Transformer Body & Neutral Through M.S.Flat 50X6mm With The Help Of Nut & Bolt Or Through Welding And Making A Main Hole Of Size 2×2 And Covering The Same By A Stone Pad For The Purpose Of Poring Water For Moisture. , Mounting Of Following T/F On Existing Double Pole/Single Pole & Making Ht/Lt Connection C) 25Kva T/F. , Fixing Of Distribution Box With Cl On Errected Pole For Giving Supply To Consumer By Connecting Consumer Cables. , Installation For 250 Kva T/F On Plinth In Proper Alignment Direction & Making Ht/Lt Connection All Cost Of Labour And T&P Which Required For Completion Of Work. , Laying Of Lt Xlpe Cable Al 3.5X150/70/240/400 Sqmm Overhead Cable With Making Loop Complete Work As Per Respo Norms And Direction By Supervising Engineer. , Laying Of Lt Xlpe Cable 1*400/150Sqmm, , Laying Of Lt Pvc Cable , Installation Of Stay Set As Direction By Supervising Engineer. , Installation Of Tpmo As Direction By Supervising Engineer. , Installation Of D.O. Fuse Set On Double Pole , Concreating Of Pole As Per Respo Norms As Direction By Supervising Engineer. , Providing & Fixing Ms Top Channel 125X65x2240mm , Providing & Fixing Of Stone Pad , Providing & Fixing Dropper Channel 100X50x2028mm , Providing & Fixing Ms Angle 75X75x6x2228mm With Cl , Providing & Fixing Dp Cl , Providing & Fixing T Off Channel With Cl , Providing & Fixing Danger Board With Nut & Bolt , Providing & Fixing Lt Incoming Pannel , Providing & Fixing Suspension Cl With I Hook , Providing & Fixing Eye Hook , Providing & Fixing Dead And Cl , Providing & Fixing Db Cl , Providing & Installation Of Henley Type Tailless Unit Protection Cubical Panel 500 A 650 V For 250 Kva Dt , Providing & Fixing Nut & Bolt Off Size , Providing & Fixing Alu. Lug 400 Sqmm , Providing & Fixing Cooper T Piece 62*225*12 , Providing & Fixing Cooper T Piece , Dismentling & Removal Of 16 Kva T/F And Recived Back To Ele. Store Center Taj Agra , Dismentling & Removal Of 100 Kva T/F And Recived Back To Ele. Store Center Taj Agra
Basic Detail
Tender No GEM/2026/B/7708086
Bidding Type Tender
Location
City Agra
State Uttar Pradesh
Key Dates
Publish Date 01 Jul 2026
Submission Date 16 Jul 2026
Open Date 16 Jul 2026
Finance
Tender Value 15 Lakhs
Tender Fee Ref. Documents
EMD 15000
Exemption Not Available
Document List
88de76b0-fe31-4a94-b18b-e8224c700278.pdf
1782567380.xlsx
1782567437.pdf
1782567445.pdf
1782567458.pdf
1782567464.pdf
1782567469.pdf
1782567475.pdf
1782567482.pdf
1782567550.pdf
1782567604.pdf
1782568145.pdf
1782568156.pdf
1782568180.pdf
ATC16_b15e5978-e88c-4eaf-a6e91782568448042_EDC2FATEHABADBUYER.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

88de76b0-fe31-4a94-b18b-e8224c700278.pdf

xlsx

1782567380.xlsx

pdf

1782567437.pdf

pdf

1782567445.pdf

pdf

1782567458.pdf

pdf

1782567464.pdf

pdf

1782567469.pdf

pdf

1782567475.pdf

pdf

1782567482.pdf

pdf

1782567550.pdf

pdf

1782567604.pdf

pdf

1782568145.pdf

pdf

1782568156.pdf

pdf

1782568180.pdf

pdf

ATC16_b15e5978-e88c-4eaf-a6e91782568448042_EDC2FATEHABADBUYER.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders