Communications and Information Technology Government Departments Closing in 6 days TDR #56250861

Tender For Providing Pvc Tanks At Ground & Overhead Pvc Tanks Near The Type Ii Staff Quarters (New Block) And Connecting To The Existing Pipe Line For Drinking Water Supply In Mannarpuram And Other Minor Repair Works In S/Q No. 6,12&148 In P&T Colony

Issued by Government Departments · Tiruchirappalli, Tamil Nadu
Tender Value
2.90 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
6 days left
EMD
5805
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tiruchirappalli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Pvc Tanks At Ground & Overhead Pvc Tanks Near The Type Ii Staff Quarters (New Block) And Connecting To The Existing Pipe Line For Drinking Water Supply In Mannarpuram And Other Minor Repair Works In S/Q No. 6,12&148 In P&T Colony, Trichy.(Re-Call).

BOQ

Name of Work:- Providing PVC tanks at Ground & Overhead PVC Tanks near the Type II Staff Quarters (New Block) and connecting to the existing pipe line for Drinking Water Supply in Mannarpuram and other Minor Repair works in S/Q No. 6,12&148 in P&T Colony, Trichy.(Re-Call).
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge.
2All kinds of soil
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
51:5:10 (1 Cement : 5 M sand : 10 graded stone aggregate 40 mm nominal size derived from natural sources).
6Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
71:1.5:3 (1 cement : 1.5 M sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
8Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources).
9Centering and shuttering including strutting, propping etc. and removal of form for :
10Suspended floors, roofs, landings, balconies and access platform
11Lintels, beams, plinth beams, girders, bressumers and cantilevers
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
13Thermo-Mechanically Treated bars of grade Fe-500D or more.
14Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 P sand).
15Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in foundation and plinth in:
16Cement mortar 1:6 (1 cement : 6 M sand)
17Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
18Kiln seasoned and chemically treated hollock wood or Country Wood.
19Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock wood
2030 mm thick shutters
21Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Float glass panes
224 mm thick glass pane (weight not less than 10 kg/sqm).
23Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
24Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (i)Single socketed pipes.
25110 mm diameter
26Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
27Bend 87.5° a) 110 mm bend
28Shoe (Plain) a) 110 mm Shoe
29Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
30110 mm
3112 mm cement plaster of mix :
321:6 (1 cement: 6 P sand)
33Finishing walls with Acrylic Smooth exterior paint of required shade :
34New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
35Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
36Two or more coats on new work.
37Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
38With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.
39With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
40Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade.
41Two or more coats on new work.
42Finishing walls with Acrylic Smooth exterior paint of required shade :
43Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).
44Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
45Of area 3 sq. metres and below
46Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
47For thickness of tiles 10 mm to 25 mm
48Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
4940 mm nominal outer dia .Pipes.
50Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work
5140 mm nominal outer dia. Pipes.
52Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
5315 mm nominal bore
54Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
55Providing and fixing CPVC ball valve of approved quality including necessary One Step solvent, etc., complete as directed by the Engineer-in-Charge.
5640 mm nominal bore
57Providing and fixing CPVC Union in CPVC pipe including cutting the pipe, necessary one step solvent etc. complete as directed by the Engineer-in-Charge.
5840 mm nominal bore
59Making connection of CPVC pipe from the Over Head Tank with the existing CPVC pipe line (leading to Kitchens) of following sizes by providing and fixing 75x40 MM CPVC Reducer, including cutting, disconnecting the existing connection, and fixing the CPVC MTA and One Step Solvent for fixing the pipe etc. complete as directed by the Engineer-in-Charge.
6040 to 80 mm outer diameter
61Providing and fixing CPVC Tank Nipple in CPVC pipe including cutting the pipe, necessary one step solvent etc. complete as directed by the Engineer-in-Charge.
6240 mm nominal bore
63Attending repairs to khurras by cleaning the debris accumulated in the RWP region, removing the vegetative growth completely including the roots by chipping the brick wall wherever required, applying acid to create unfavourable conditions to the roots to bud up etc complete. After removal of roots the RWP is to be relaid in right alignment and alround is to be packed water tight with cement mortar and water proofing compound. Also the top surface is to be neatly finished with floating coat having proper slope to drain the rain water. All operations to be executed as per the directions of Engineer-in charge.
64Cutting the tree branches those are close to the building, touching the buildings and extending over the terrace including disposal of the same as directed by the Engineer-in-Charge.
65Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
6625 mm average thickness
67Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
68Bars upto 12 mm diameter
69Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
70SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer.
71Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
7212 mm average thickness.

AI Tender Summary

OUR REF NO 56250861
AUTHORITY Government Departments
TENDER VALUE 2.90 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Bharat Sanchar Nigam Limited
Work Description Tender for Providing Pvc Tanks At Ground & Overhead Pvc Tanks Near The Type Ii Staff Quarters (New Block) And Connecting To The Existing Pipe Line For Drinking Water Supply In Mannarpuram And Other Minor Repair Works In S/Q No. 6,12&148 In P&T Colony, Trichy.(Re-Call).
Basic Detail
Tender No 11(R1)/EE/BSNL/CD/TRY/2026-27
Bidding Type Tender
Location
City Tiruchirappalli
State Tamil Nadu
Key Dates
Publish Date 01 Jul 2026
Submission Date 13 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 2.90 Lakhs
Tender Fee 590
EMD 5805
Exemption Not Available
Document List
742be986-65ef-44bb-aaed-1c01c99d97fd.html
BOQ_329687.xls
Tendernotice_1 (1).pdf
Tendernotice_2 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

742be986-65ef-44bb-aaed-1c01c99d97fd.html

xls

BOQ_329687.xls

pdf

Tendernotice_1 (1).pdf

pdf

Tendernotice_2 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender