Housing Urban and Rular Development Government Departments Closing in 7 days TDR #56250839

Tender For 1) repair maintenance Various Electrical Installations And Mechanical Equipments At Dseu (Kasturba C Us) At Pit Ura & Dseu C Us, Wazirpur Delhi. During 2026-27. 2) repair maintenance Of Various Electrical & Mechanical Services At Gnd Co-Ed

Issued by Government Departments · Delhi, Delhi
Tender Value
1.21 Crore
Estimated cost
Bid Submission
08 Jul 2026
7 days left
EMD
2.43 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for 1) repair maintenance Various Electrical Installations And Mechanical Equipments At Dseu (Kasturba C Us) At Pit Ura & Dseu C Us, Wazirpur Delhi. During 2026-27. 2) repair maintenance Of Various Electrical & Mechanical Services At Gnd Co-Ed Polytechnic At Sector - 15, Rohini Delhi During 2026-27

BOQ

Name of Work:- 1) RMO various electrical installations and mechanical equipments at DSEU (Kasturba C us) at Pit ura & DSEU C us, Wazirpur Delhi. During 2026-27. 2) RMO of Various Electrical & Mechanical services at GND CO-ed Polytechnic at Sector - 15, Rohini Delhi During 2026-27
Sl. No. Item Description
1a) Providing Service for round the clock operaion and maintenance of 1 no. 11 KV/415 V sub Station at site of work, round the clock on all days of the week including Sundays and Holidays. The job includes recording of all parameters like HT & LT voltages, current, power factor etc. and routine periodical checking and testing complete as per terms and conditions. b) Providing Service for day to day maintenance and upkeeping of all the internal and external electrical installations including compound light, street light etc. i/c removal/rectification the fault/complaint by attending the complaint, Recording and Monitoring of the complaints at site of work complete with following of minimum workmen as :-. i) Wireman cum Operator - 3 Nos. (1 No. in each of Three Shifts i.e. 6 AM to 2 PM & 2 PM to 10 PM & 10 PM to 6 AM)ii) Skilled Wireman cum Pumpset operator - 1 No. (In General Shift i.e. 9 AM to 5 PM)iii) Khallasi - 1 No.- In General Shift (9 AM to 5 PM) Khallasi - 1 No.- In General Shift (9 AM to 5 PM)
2) Providing Service for day to day maintenance and upkeeping of all the internal and external electrical installations including compound light, street light etc. i/c removal/rectification the fault/complaint by attending the complaint, Recording and Monitoring of the complaints at site of work complete with following of minimum workmen as :-. (a) For DSEU Campus - I Skilled Wireman - 1 No. (In General Shift i.e. 9 AM to 5 PM) and 1 No. For DSEU Campus - II (Leather Complex) Skilled Wireman - 1 No. (In General Shift i.e. 9 AM to 5 PM)
3Khallasi - 1 No.- In General Shift (9 AM to 5 PM)
4Supplying and fixing of following electrical accessories for day maintenance in the existing electrical installation etc. as reqd ( Labour for fixing is already include in above item) (Material consumption statement will be maintained by agency in Task Register). a) SP 5/6 A, one way modular switch, ISI marked
5b) SP 15/16 A, one way modular switch, ISI marked
6c) 3 pin 5/6 A modular socket outlet, ISI marked
7d) 6 pin 15/16 A modular socket outlet, ISI marked
8e) 15 Amp 3 Pin plug Top (ISI Marked)
9f) 25A Modular SPMCB 'C' Curve
10g) 6A, to 32 A, ratings, SP MCB, \\"C\\" Curve, 10 KA Breaking Capacity
11h) 6A, to 32 A, ratings, DP MCB, \\"C\\" Curve, 10 KA Breaking Capacity
12i) Call bell/ buzzer, single phase
13j) Modular bell push, ISI marked
14k) 40 Amp DPMCB \\"C-Curve\\" 10 kA breaking capacity
15l) 63 Amp DPMCB 10 kA breaking capacity
16m) 63 Amp TPN MCB 10 kA breaking capacity
17n) 400 mm sweep wall fan
18o) 300 mm 1400 RPM heavy duty exhaust fan ISI Mark
19p) Supplying & replacement of 2.5 MFD capacitor
20q) two module stepped fan regulator
21r) 100 Amp, 16 KA, TPMCCB
22s) 125 Amp, 16 KA, TPMCCB
23t) 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable
24u) 4.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable
25v) LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector i) 30 watt
26w) LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) i) 40 watt
27x) LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) i) 36 watt
28y) LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. i) 72 watt
29ii) 120 watt
30z) LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) of following body materials. i) 150 watt
31ii) 200 watt
32aa) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req i) 1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
33Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C
34Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi core cable in existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 core 1.5 sq. Mm
35b) 3 core 4 sq. mm
36c) 3 core 6 sq. mm
37Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amps switch
38b) 3 pin5/6 amp socket outlet
39c) 15/16 A switch
40d) 6 pin 15/16 A socket outlet
41Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. a) 5/6 amps switch
42b) 2 way 5/6 amps switch
43c) 15/16 amp switch
44d) 3 pin5/6 amp socket outlet
45e) 6 pin15/16 amp socket outlet
46Providing and fixing of PVC Trunking of following sizes complete with flexible cover, joint, endcap, cover on surface of wall/existing mounting etc. as required. a) 32 mm x 20 mm
47Supplying, Installation, testing and commissioning of surface/ recess mounted type Luminaries, glare free opal diffuser LED Panel of Nominal size 1180x280 mm suitable for Armstrong / POP / GB ceiling with made out of CRC / MS Powder coated housing. Having the following specifications :i) Total System Lumens - 34 to 36 Watt,ii) Color Temperature - 5700 K to 6500 K,iii) Power Factor - > 0.95iv) CRI - > 80,v) System Lumen Efficiency - = > 100 LM/W,including connections, testing etc complete as required.
48Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
49Dismantling existing fire extinguishers and refilling of following capacity and type from installed position removing old gas/other extinguishing material from cylinder hydraulic pressure testing taking to workshop,refilling of gas/cartridge/other extinguishing material,pasting of stickers, bring back to site and reinstallation etc as required. a) ABC powder type fire extinguisher 6 kg capacity
50b) Co2 gas type fire extinguisher 4.5 kg capacity
51Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0C with required accessories :a) Pendent Sprinkler
52Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
53Testing of fire fighting system and fire alarm on weekly basis i/c cleaning, oiling, greasing/ Servicing / Repairing of all Fire Fighting and Fire Alarm system for smooth functioning making arrangement for mock drill as and when required i/c skilled labour and maintenance of testing register etc complete as reqd.
54Rewinding of following size Submersible/Mono submersible/ monoblock pumpset i/c dismantling of pumpset from site, cartage from site to work shop and return back, cutting the burnt winding wire (credit for old winding wire) & rewinding the same with PVC insulated copper winding wire etc. as reqd. a) 2 HP
55b) 5 HP
56c) 7.5 HP
57S/I/T/C of Starter Control panel for 3 phase motor upto 7.5 HP having DOL starter of relay range 9 to 14 Amp. on the wall mounting comprising of contactor, relay, single phase preventor, auto-manual On/Off voltage selector switch, voltmeter, ammeter, push buttons etc. as reqd.
58Lowering of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley and tripod etc. as reqd.
59Taking out of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley block and tripod complete as reqd.
60SITC of 5 HP submersible pumpset having a discharge range of (470-240) LPM ± 10 % tolerance for head range of (18-43) Metre ± 10% tolerance suitable for operation on 3 phase, 415v 50Hz AC supply i/c flange cable joint, gasket, nut & bolts etc as required.
61SITC of 2 HP submersible pumpset having a discharge range of (100-20) LPM ± 10 % tolerance for head range of (53-409) Metre ± 10% tolerance suitable for operation on 3 phase, 415v 50Hz AC supply i/c flange cable joint, gasket, nut & bolts etc as required.
62Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : a) 50 mm
63New Generation IP65 LED, 25 Watt post top family, energy saving, enviromental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform ilumination for different applications etc. as required at site.
64Round the clock operation & routine maintenance of 11 KV / 41S V, 2 x 325 KVA Electric substation complete with HT Panel, transformer & LT panel including 1 x 180 K VA DG Set installed at site on all days of the month including sundays and holidays. The jobs includes recording of all parameter like HT & LT voltages, current, power factor etc and routine periodical checking and testing of DG Set etc complete as per terms and conditions. &also maintenance of El & Fans comprising of all light points/power points/fan points/power plug points/industrial type socket points,MCB's and MCB DSs of distribution panel etc cleaning of the electrical installation, lodging of elecirical complaint in the complaint register.WIREMAN-3 Nos (in Round TheClock )Khallasi-1 Nos (in General shift )
65Supplying and fixing of following electrical accessories for day maintenance in the existing electrical installation etc. as reqd ( Labour for fixing is already include in above item) a) SP 5/6 A, one way modular switch, ISI marked
66b) SP 15/16 A, one way modular switch, ISI marked
67c) 3 pin 5/6 A modular socket outlet, ISI marked
68d) 6 pin 15/16 A modular socket outlet, ISI marked
69e) 15 Amp 3 Pin plug Top (ISI Marked)
70f) 25A Modular SPMCB 'C' Curve
71g) 6A, to 32 A, ratings, SP MCB, \\"C\\" Curve, 10 KA Breaking Capacity
72h) 6A, to 32 A, ratings, DP MCB, \\"C\\" Curve, 10 KA Breaking Capacity
73i) Call bell/ buzzer, single phase
74j) Modular bell push, ISI marked
75k) 63 Amp DPMCB 10 kA breaking capacity
76l) 63 Amp TPN MCB 10 kA breaking capacity
77m) 400 mm sweep wall fan
78n) 300 mm 1400 RPM heavy duty exhaust fan ISI Mark
79o) Supplying & replacement of 2.5 MFD capacitor
80p) two module stepped fan regulator
81Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. Mm
82b) 3 x 4 sq. mm
83c) 3 x 6 sq. mm
84Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
85b) 25 mm
86Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 18- 22 Watt
87b) 36 Watt
88Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)a) 36 Watt
89Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trima) 18 watt
90Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (Brush Less Direct Current (BLDC) Fan without Remote)a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
91Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.a) 100 A, 16 KA,TPMCCB
92b) 125 A,36KA,FPMCCB
93Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 A
94Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. a required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 72 watt
95Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 100 watt
96Supplying & fixing Hot press moulded SMC box of size 250 x 200 x 105 mm i/c S/F Aluminium Bus Bar of suitable size i/c Phase, Neutral and Earth link, including 1 no. 6A to 32A rating 240 V 10KA \\"C\\" curve SP MCB & 1 no. earth bar, 1 no. Neutral bar, DIN rail mounting with openable hinged door on street light pole as required complete with mounting bracket/arrangement made of 5 mm thick GI flat iron etc. complete as required at site. pole/wall etc as reqd. at site i/c dismantling of existing.
97New Generation IP65 LED, 25 Watt post top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination for different applications etc. as required at site.
98Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade of following size on wall surface as required. (a) 4 X 25 sq. mm Alu. Cable.
99Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.a) 1 or 2 Module
100b) 3 Module
101c) 4 Module
102d) 6 Module
103e) 8 Module
104f) 12 Module
105Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
106Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
107Supply and fixing of following ABC type fire extinguisher (ISI marked MAP 90%) complete delivery hose horn, squeeze grip release valve, locking arrangement on wall with the help of necessary clamps and duly painted in red colour etc. as reqd. a) 6 kg capacity ABC type fire extinguisher (ISI)
108Supply and fixing of 4.5 kg. capacity CO2 type fire extinguisher (ISI) marked complete delivery hose horn, squeeze grip release valve, locking arrangement on wall with the help of necessary clamps and duly painted in red colour etc. as reqd
109Rewinding of following size Submersible/Mono submersible/monoblock Pumpset i/c dismantling of Pumpset from site, cartage from site to work shop and return back, cutting the burnt winding wire (credit for old winding wire) & rewinding the same with PVC insulated copper winding wire etc. as reqd. a) 1 HP
110b) 5 HP
111Supplying, Repairing & Replacement of following accessories for 5/7.5 HP capacity Mono-submersible/ Submersible motor pump set i/c dismantling old defective parts, testing, commissioning etc. as reqd.i) Remetalling& grinding of shaft - 1 no.ii) Turning & polishing of rotor sleeve - 1 no.iii) G.M. Bush - 4 nos.iv) Thrust bearing with thrust plate - 1 setv) Rubber water seal - 1 no.
112Supplying and Fixingof fully automatic Star delta starter panel box, suitable for upto 10 HP Motor pump set (Heavy duty) comprising of voltmeter, ammeter, push buttons, indication Lamp, 3 position selector switch, manual SPP auto in new panel complete with internal wiring etc as reqd.
113Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : a) 50 mm
114b) 65 mm
115Lowering of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley and tripod etc. as reqd.
116Taking out of upto 3/5/7.5/10/20 HP Mono Submersible/Sewage/ Submersible P/set along with G.I. pipe in existing well/underground tank with the help of chain pulley block and tripod complete as reqd.
117Comprehensive routine maintenance of Window / Split type ACs units of 1.0 / 1.5 / 2.0 TR capacity units of different makes installed at various locations as per inventory attached, i/c checking, cleaning of filter, tightening of electrical connection, repairing / replacement of remote, capacitor running type, all types of defective parts,gun metal taps,electronic parts ,float valve assembly including topping up of refrigerant in compressor, refrigeration pipe and ensure proper functioning of the ACs the scope include attending complaint with in 24 Hrs. as per direction of Engineer -in- charge & wherever reqd. (1st June 2026 to 31st October 2026) & (1st March 2027 to 31st May 2027)(232 Units X 8 Months = 1856 Units)
118Complete servicing of WTAC/STAC/unit of 1/1.5 / 2.0 TR capacity including dismantling the AC from its existing position at various locations/grill/window cutting,washing with High pressure water spray electric machine coil cleaning with D- Scaling Chemical, drying with air blower ,oiling, greasing, of blower fans cleaning of evaporative and condensing coil with suitable chemical like coil cleaner, as required in its existing position complete as per direction of Engineer -in- charge & wherever reqd.
119Replacement of printed circuit assembly (PCB) of the Existing indoor Unit inverter type Split/WTAC AC 1.5/2.0 TR Complete with connection & Testing etc. as required at side in the machine as per requirement & approval of the Engineer-in-Charge. (Dismantled material shall be retained by the contractor).
120Replacement of printed circuit assembly (PCB) of the Existing Outdoor Unit Split AC/WTAC 1.5/2.0 TR with connection & Testing etc. as required at side in the machine as per requirement & approval of the Engineer-in-Charge. (Dismantled material shall be retained by the contractor).
121Repairing of PCB card of 1.5/2 TR capacity WTAC/split type AC unit having following capacity afterdismantling the defective card from AC unit & refixing the same i/c connections of electrical wires/cables & thimbles connection, testing & commissioning etc. complete as required.
122Supplying & charging of Refrigerant gas (R 22/32/refrigerant suitable as per requirement of AC unit) in the following type capacity AC units i/c leakage testing removing the leakage, pressure testing, flushing the complete system, vacuumizing and gas charging complete as required. (Cost for gas & labour charges already included in the below mentioned item) (Note:- Quantity of gas filled shall be entered in Consumption Register maintained by the agency) a) In 1.5 TR WTAC/STAC capacity
123b) In 2.0 TR STAC capacity
124Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
125b) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
126c) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
127d) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2mm
128Supplying and replacement of following parts (Labour already included in above item) a) Rotary Compressor 1.5 Ton
129b) Rotary Compressor 2 Ton
130c) Reciprocating compressor 1.5 Ton
131d) Reciprocating compressor 2.0 Ton
132e) Outdoor fan motor 1.5 Ton
133f) Out door fan motor 2 Ton
134g) Indoor fan motor 1.5 Ton
135i) Window AC fan motor
136j) Cooling coil copper - 1.5/2 Ton
137k) Condenser coil copper- 1.5 ton
138Dismantling of existing suitable 1.5 TR/2.0 TR capacity WTAC unit & both indoor & outdoor in case of STAC etc. with equipments complete as reqd.
139Re-Installation of STAC Unit existing suitable 1.5 TR/2.0 TR capacity STAC unit & both indoor & outdoor in case of STAC etc. with equipments complete as reqd.
140Comprehensive Annual Maintenance of 1000 LPH RO Plant i/c twelve mandatory services in a year cleaning/ Repairing/ Replacement of all filters, Membrane & all electrical and electronic spare part, Repairing/ Replacement of High Pressure Pump, Raw Water Pump, Control Panel, and replacement of like Spun Micron Filters every month, Providing Antiscalant Dosing Chemical, once in a year Membrane cleaning/ replacement as if any required, Media as/ if any required, Attending complaints within 24 working hours with complete over haulting and servicing etc.(Dismantled Shall be retained with contractor. (KGIT = 1, GND= 1)
141Comprehensive Annual Maintenance of 100/80/60 LPH capacity RO System, connected prior to water coolers i/c four mandatory services (Replacement/ Repairing of All Filters and Membrane), repair/ replacement of all electrical and electronic spare parts and replacement of consumables in a year like Particulate Filter 20”, Sediment Filter 20”, Pre Carbon Filter 20” and Post Carbon Filter, UF Filter, once in a year Membrane cleaning/ replacement as if any required, Attending complaints within 24 working hours with complete overhaulting and servicing etc. (Dismantled Shall be retained with contractor). (Qty 09 Nos.-1 job)
142Servicing, checking & cleaning of 11 KV HT panel board by opening the HT panel & CT's chamber, removing the dust with blower/vacuum cleaner & dusting from the panel checking, cleaning & decarbonizing the HT panel, fixed contacts of swithgear&CT's with CTC/CRC. & tightening of contacts & joints of bus bars, CT connections, PT connections after removing HT taping & compound, tightening of cable end terminations, replacement of burnt/heated thimbles, nut bolts, HT taping &monoplast compound etc. wherever reqd testing etc complete as reqd.
143Servicing, checking & cleaning of LT panel board by opening the LT panel, removing the dust with blower/vacuum cleaner & dusting from the panel checking, cleaning & decarbonizing the LT panel, fixed contacts of swithgear& CT's with CTC/CRC & tightening of contacts & joints of bus bars, CT connections, all other connections after removing, tightening of cable end terminations, replacement of burnt /heated thimbles, nut bolts etc. wherever reqd testing etc complete as reqd. 2 Nose Panel board.
144Servicing of Draw out type 11 KV, 630 amp, 3phase OCB from the HT panel complete, Checking of Tripping Mechanisium, Greasing of moving Contacts, Cleaning of Carbon from Main Contacts, Submission of Test Report, replacement of minor spare parts such as spring, nuts bolt & washer, setting right the mechanism and reassembling, testing and commissioning etc as reqd.( MaterialExtra )
145Servicing of Draw out type 800/1000/1250amp, ACB, 3Pole, 3 Pole, 415 volt 50 Hz from the MV Panel, complete, cleaning, lubricating of moving parts, checking & testing of wring system, Cleaning of Carbon from Main Contacts, Submission of Test Report cleaning & replacement of minor spare parts such as spring, nuts bolt & washer, setting right the mechanism and reassembling, testing and commissioning etc as reqd. ( Material Extra )
146Draw out of the complete set of 2 No. over load & one each fault IDMT relay, cleaning. Checking of wiring system calibration with secondary injection test kit, setting of tripping plugs according to the load complete with testing and commissioning as reqd.
147Dehydration and filtration of 630 KVA, transformer oil up to 50 KV , BDV complete as reqd.--2 Job
148Supplying and filling of Transformer oil up to the required level of transformer etc. as reqd.
149Complete servicing of P.T. assembling of 11 KV H.T. Panel cleaning all contacts, checking and tighten control wiring, checking P.T. fuse, dehydration of oil, i/c replacement of miner parts ie suitable size copper wire, thimble, PVC sleeve nut bolt, washer etc wherever, complete testing etc as reqd
150Supplying &Fixing the power pack unit of 24 Volt, DC for tripping shunt trip coil of OCB/VCB according IDMT relays of 11KV HT panel i/c control wiring with copper wire, copper thimble & assembling the existing power pack unit etc complete as reqd.
151Supply and Replacement of SILIKA GEL breather with silika gel of transformer etc. complete as reqd.
152Servicing & checking of 630 KVA transformer oil type complete checking, removed the oil leakage top cover, HT Bushing, LT bushing, buch. relay and replacement oil seal, nut bolt, complete, cleaning, testing and reassembling, testing etc as reqd.
153Servicing and checking of APFC (capacitor) Panel, replacement of bourn control wiring, cupper legs, PVC sleave, cupper wire, 3phase 415 Volt AC, 50 Hz LT panel complete, cleaning & testing of wiring system, replacement of minor parts such as nuts bolt & washer, testing and commissioning etc as reqd.(Materials Extra)
154Checking, testing of 630 KVA transformer oil type, dismantling the HT connection, LT connection, Earthing in existing 11 KV HT transformer etc as required complete, testing following test as reqd.1- Voltage ratio test.2- Winding resistance test.3- Magnetic Balance test.4-Magnetic current test.5- High Pot Testing of 11 KV HT Winding.
155Replacement of defective items in HT/ LT panel board.a) indication light 220/ 110/ 24 Volt AC/ DC - 38 Nos.b) Volt / Amp. Meter size 96*96 SQ MM digital type , single phase - 8 Nos.c) Space heater 220 Volt, 200 watt , 50 Hz - 6 Nos.d) APFC relay 415 Volt, 12 Stage. Make- L&T - 4 Nos.e) Over current & Earth fault relay MC 61, make L&T/ CG - 3 Nos.
156Servicing, checking & cleaning of 11 KV HT panel board by opening the HT panel & CT's chamber, removing the dust with blower/vacuum cleaner & dusting from the panel checking, cleaning & decarbonizing the HT panel, fixed contacts of switchgear & CT's with CTC/CRC. & tightening of contacts & joints of bus bars, CT connections, PT connections after removing HT taping & compound, tightening of cable end terminations, replacement of burnt/heated thimbles, nut bolts, HT taping & monoplast compound etc. wherever reqd testing etc complete as reqd.
157Servicing, checking & cleaning of LT panel board by opening the LT panel, removing the dust with blower/vacuum cleaner & dusting from the panel checking, cleaning & decarbonizing the LT panel, fixed contacts of swithgear& CT's with CTC/CRC & tightening of contacts & joints of bus bars, CT connections, all other connections after removing, tightening of cable end terminations, replacement of burnt /heated thimbles, nut bolts etc. wherever reqd testing etc complete as reqd. 2 Nose Panel board.
158Servicing of Draw out type 11 KV, 630 amp, 3phase OCB from the HT panel complete, Checking of Tripping Mechanisium, Greasing of moving Contacts, Cleaning of Carbon from Main Contacts, IR Value Testing with Megger + Opening & Closing VCB Testing with Time - Interval Testing Kit +Continuity Test of Poles + Contact Resistance with CRM Testing Kit, Submission of Test Report, replacement of minor spare parts such as spring, nuts bolt & washer, setting right the mechanism and reassembling, testing and commissioning etc as reqd.
159Servicing of Draw out type 800/ 1000 amp, ACB, 3Pole, 3 Pole, 415 volt 50 Hz from the MV Panel, complete, cleaning, lubricating of moving parts, checking & testing of wring system, Cleaning of Carbon from Main Contacts, IR Value Testing with Megger + Opening & Closing ACB Testing with Time - Interval Testing Kit +Continuity Test of Poles + Contact Resistance with CRM Testing Kit, Submission of Test Report cleaning & replacement of minor spare parts such as spring, nuts bolt & washer, setting right the mechanism and reassembling, testing and commissioning etc as reqd.
160Draw out of the complete set of 2 No. over load & one each fault IDMT relay, cleaning. Checking of wiring system calibration with secondary injection test kit, setting of tripping plugs according to the load complete with testing and commissioning as reqd.
161Dehydration and filtration of transformer oil up to 50 KV , BDV testing complete as reqd.
162Supplying and filling of Transformer oil up to the required level of transformer and OCB etc. as reqd.
163Complete servicing of P.T. assembling of 11 KV H.T. Panel cleaning all contacts, checking and tighten control wiring, checking P.T. fuse, dehydration of oil, i/c replacement of miner parts ie suitable size copper wire, thimble, PVC sleeve nut bolt, washer etc wherever, complete testing etc as reqd.
164Supplying &Fixing the power pack unit of 24 Volt, DC for tripping shunt trip coil of OCB/VCB according IDMT relays of 11KV HT panel i/c control wiring with copper wire, copper thimble & assembling the existing power pack unit etc complete as reqd.
165Supply and Replacement of SILIKA GEL breather with silika gel of transformer etc complete as reqd.
166Supplying and replacement of LED type indication light LT/ Ht panel, supply voltage 110 Volt AC, 50 Hz. In the existing panel.
167Servicing & repairing of 500 KVA transformer oil type, removed the oil leakage top cover, HT Bushing, LT bushing, buch. relay and replacement gaskit, oil seal, nut bolt, drain out transformer oil required level and refilling complete, cleaning, testing and reassembling, testing and commissioning etc as reqd.
168Supply and replacement of ML 3 power contractor 3,phase, 415 Volt, 50 Hz i/c dismantling defective unit complete testing etc as required.
169Servicing and checking of APFC (capacitor) Panel, replacement of bourn control wiring, cupper legs, PVC sleave, cupper wire, 3phase 415 Volt AC, 50 Hz LT panel complete, cleaning & testing of wiring system, replacement of minor parts such as nuts bolt & washer, testing and commissioning etc as reqd.(Materials Extra)
170Supply and Replacement of defective items in HT/ LT panel board.a) Indication light 220/ 110/ 24 Volt AC/ DC make- L&T - 32 Nos.b) Volt/Amp. Meter size 96*96 SQ MM digital type, single phase - 4 Nos.c) Volt & Amp. Mtr. Size 144*144 SQ MM, 415 Volt AC, - 8 Nos.d) Space heater 220 Volt, 200 watt , 50 Hz - 6 Nos.e) APFC relay 415 Volt, 12 Stage. - 1 No.f) Over current & Earth fault relay Model No.- MC 61, - 3 Nos.g) Door Lock with key - 30 Nos.
171Routine Maintenance of following capacity D.G. Sets with AMF panels including preventive and periodical maintenance of all connected accessories of D.G. Sets and attending day to day complaints, monthly visit of electrical and mechanical service personals for A-Check, rectification of fault etc. complete as reqd. as per terms and conditions. Including Carrying out of B-Check maintenance/Servicing on Twice in year.a) 250 KVA capacity (Cummins make) - 01 No. installed at Kasturba Gandhi Polytechnic, Pitampura
172Carrying out B-Check maintenance of 01 Nos. (Kirlosker make) ,400 KVA capacity D.G. Sets with AMF panels including supplying & replacement of following B-Check kit materials and other safety & primary elements, consumables etc. complete as per terms and conditions.(Twice in year)a) ELement Lube Oil - 2 Nos.b) Fuel Filter - 2 Nos.c) Filter Coolant - 2 Nos.d) Diesel 100 Ltrs. e) Element Air Cleaner - 1 No. (AF2587700)f) Element Air Cleaner - 1 No. (AF2587800)g) Premixed Coolant 5 Ltrs. - 2 Nos.h) Petronas Urania 1000 CH-4 20 Ltr.
173Routine Maintenance of following capacity D.G. Sets with AMF panels including preventive and periodical maintenance of all connected accessories of D.G.Sets and attending day to day complaints, monthly visit of electrical and mechanical service personals for A-Check, rectification of fault etc. complete as reqd. as per terms and conditions. Including Carrying out of B-Check maintenance/Servicing on Twice in year.a) 180 KVA capacity (Kirloskar make) - 01 No. installed at Guru Nanak Polytechnic, Sec -15 Rohini.
174Carrying out B-Check maintenance of 01 Nos. (Kirlosker make) ,400 KVA capacity D.G. Sets with AMF panels including supplying & replacement of following B-Check kit materials and other safety & primary elements, consumables etc. complete as per terms and conditions.(Twice in year)a) Air Filter Primary - 1 Nos.b) Air FIlter Safety- 1 Nos.c) Fuel Filter Kit 1.1 Ltr.- 2 Nos.d) Spinon Lube Oil Filter - 2 Nos.e) Kirloskar Care Premium Genuine Oil 20 Ltrs. Can -2 Nos.f) Kirloskar Care Premium Genuine Oil 5 Ltrs. Can - 4 Nos.g) Koel Care Genuine Coolant Premix 5 Ltr. Can - 2 Nos.h) 150 AH Kirloskar Green Battery - 2 Nos.i) Battery Terminal - 4 Nos.j) Battery Charger 16A 24V - 1 No.k) Rediator Descaling Charges at Site - 1 No.l) Genset Controller 7320 MK II - 1 No.
175Annually comprehensive maintenance of following capacity true online redundant type UPS having maintenance free battery for backup on full load, static bypass arrangement etc. by visiting fortnightly visit and on breakdown of equipment including replacement of defective parts including all material spares of UPS such as transformer including all electronic components, leads, wires, thimbles, etc except replacement of batteries complete with fortnightly visit including breakdown call etc complete as required for smooth functioning of UPS System by qualified service engineer as per terms and conditions attached.a) 10 KVA UPS - 2 Sets (Perpetual Make) installed at KGIT Pitampura
176b) 10 KVA Single Phase UPS-1 Set (Perpetual Make) installed at GND Campus Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56250839
AUTHORITY Government Departments
TENDER VALUE 1.21 Crore
LAST DATE 08-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for 1) repair maintenance Various Electrical Installations And Mechanical Equipments At Dseu (Kasturba C Us) At Pit Ura & Dseu C Us, Wazirpur Delhi. During 2026-27. 2) repair maintenance Of Various Electrical & Mechanical Services At Gnd Co-Ed Polytechnic At Sector - 15, Rohini Delhi During 2026-27
Basic Detail
Tender No 10Recall/SE/NW Circle/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 01 Jul 2026
Submission Date 08 Jul 2026
Open Date 08 Jul 2026
Finance
Tender Value 1.21 Crore
Tender Fee Ref. Documents
EMD 2.43 Lakhs
Exemption Available
Document List
27934858-4166-40de-9bdf-0315659e5aaa.html
BOQ_391840.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

27934858-4166-40de-9bdf-0315659e5aaa.html

xls

BOQ_391840.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders