Tender For Supplying And Installation Of Inverter Ductable Ac In Library Building At Post Graduate Govt. College, Sector-11, Chandigarh. (Ibm Scheme No. G3/2025/25031). (Sitc Of Water Cooler Scroll Chilling Machines). (2 X 48 Tr)
Tender Value
95.48 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
7 days left
EMD
1.90 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supplying And Installation Of Inverter Ductable Ac In Library Building At Post Graduate Govt. College, Sector-11, Chandigarh. (Ibm Scheme No. G3/2025/25031). (Sitc Of Water Cooler Scroll Chilling Machines). (2 X 48 Tr)
BOQ
| Sl. No. | Item Description |
| 1 | EQUIPMENT |
| 2 | WATER COOLED SCROLL CHILLING MACHINES |
| 3 | Supply, Installation, testing and commissioning of water cooled DX Chiller of 48.0 TR and unit shall consist with hermatic sealed scroll type compressors suitable for R-407c/R410-a refrigerant. Shell and tube water cooled Condenser, Insulated Shell and tube DX Evaporator, Micro Processor Controller as supplied by OEM as part of Chiller Package. The Unit mounted starter panel with double door construction shall be single Power point type complete with IP 55 Degree protection complete with Under/Over load, voltage, phase loss and phase reversal protection, Single Phase Preventers, communication card which can accept 4-20 mA or 2-10 V dc analog signal. Each Chiller package comprise of Min 2 compressors. |
| 4 | The unit shall be complete with Discharge Service valves to isolate refrigeration circuits, vibration Isolators to isolate chiller from building structure, pressure gauges Electronic expansion valves, solenoid valves, anti-freeze thermostats, refrigerant piping with Insulation for suction line, accessories of Safety valve, angle valve, liquid line indicator, water flow switch, Relief valve, Isolating valves and including MS stand to install the chiller units fabricated out of suitable size of structural steel sections etc. all as per OEM. All accessories housed in a single chasis design. |
| 5 | The noise level measured at a distance of 3 Mtr from the machine at anywhere in the plant room shall not exeed 80 dBA +-5% |
| 6 | The chilled water type AC plant will be suitable for operationon 3 phase AC 50 Hz supply . |
| 7 | The said Chiller package shall have stepped control of 100/50% of rated capacity since scroll comoressors works at full capacity only. |
| 8 | The chiller shall be as per specifications. The water chilling machine shall meet the following design parameters |
| 9 | The Chiller shall be 3 Star Rated and above as per BEE |
| 10 | Chilled Water leaving Temp. : 44°F (6.7ºC) |
| 11 | Chilled Water entering Temp. : 54°F(12.2ºC) |
| 12 | Evaporator fouling factor :0.0005(FPS) |
| 13 | Condenser Water Leaving Temp. : 97.5°F(36.40º C) |
| 14 | Condenser Water Entering Temp. : 90.0°F(32.22º C) |
| 15 | Fouling factor of condenser : 0.001(FPS) |
| 16 | IKW/TR: 0.87 at 100% Load |
| 17 | Cooling capacity : 48.0TR |
| 18 | Water-cooled Scroll Chilling Machine as described above. |
| 19 | The price should include all clearance |
| 20 | charges, unloading and shipment till site |
| 21 | Including Insurance Charges ,Unloading at site, placement of Chilling machine on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned chiller. |
| 22 | (2 W + 0 S) |
| 23 | Chiller 48TR (Actual Capacity) (2W+0S) |
| 24 | Make Carrier/Trane/York/Voltas/Blue Star/ Daikin |
| 25 | Note : Vendor Shall Supply all chiller of same make at site ,different brands are not allowed |
| 26 | Hot water generator |
| 27 | Supplying, installation, testing and commissioning of electrical HW generator equipped with sufficient number of electrical immersion heaters. The Hot Water Generator shall be of following capacity made of 8mm MS sheet and dish end made of 10mm MS having 16 gauge stainless steel lining with heaters arranged in banks and controlled by electronic Controller and Thermostats so that hot water is generated at 70 degree C with nominal variation including 75mm thick resin bonded fibre glass insulation of 24 kg/Cum density finished with 1.25mm thick aluminum sheet cladding including necessary electrical panel having suitable incoming and outgoing switchgears for heaters, automatic controls such as manual reset high temperature water outlet, step controller and recycling relay, 'ON' 'OFF' switch thermostats, pilot light, low water cutoff and other controls as per manufacturers recommendations including inlet and outlet connections for water as per specifications complete with pressure release valve, low level cut-out. Autovent sight-glass, foundation for Hot water generator as per specifications complete as required. All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The generator shall be suitable for 415 (+)/(-) 10% volts, 50 cycle, 3 phase power supply. The entire generator shall be factory assembled and tested at 350 PSI pressure. |
| 28 | The price includes loading/ unloading and shipment till site Including Insurance Charges ,Unloading at site,RCC Foundation, placement of HWG on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned HWG. |
| 29 | 100.0 KW Actual Capacity Hot water generator with Multiple Bank |
| 30 | Make : Rapid Cool/KEPL/Emerald |
| 31 | PUMP SETS |
| 32 | PRIMARY VARIABLE SPEED PUMPING SYSTEM |
| 33 | Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. Casing (Volute) - Ductile Iron.Impeller - 316 SS - Statically and Dynamically BalancedCasing Gasket - Confined Non Asbestos FiberPump Shaft - 316 SS .Flush Line - Braided Stainless SteelMechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) with external flushline. Motor Type - TEFC Squirrel Cage, Efficiency Class - I FIVE, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply, RPM as per OEM standard. |
| 34 | VFD - Integrated motor mounted over Pump with IP- 55 protection. pump should operate through sensorless control or wireless DPT control.Pump Efficiency should be more than 75% Integrated fliter to meet EN61800-3 for RFI Control, Integrated DC link Reactor equivalent in performance to a 5% AC line reactor.All the VFD should display the dynamic head & flow rate of the pump using inputs from ultrasonic flow meter and digital pressure gauge or using sensorless alogorithms,( Per pump,1 flow meter and 2 pressure gauges to be supplied and integrated with motor mounted VFD driven pump for the display of flow and head on VFD). Pump manufacturer to supply Ultrasonic flow meter and digital pressure gauges along with the pumps supplied or can display individual flow and head per pump on respective VFD using sensorless alogorithms |
| 35 | The price includes all clearance charges, unloading and shipment till site Including Insurance Charges ,Unloading at site,RCC Foundation, placement of PUMPs on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned pumps. |
| 36 | The system shall be complete in all respects and suitable for following ratings andduty. |
| 37 | Min 230 USGPM * 25 M Head or as per actual at site with Min Efficiency. 75% for Chilled water circuit (1Working + 1Standby) |
| 38 | Make :Xylem,Grundfoss,Armstrong |
| 39 | CONDENSOR WATER PUMPS (FIXED SPEED) |
| 40 | Supply, installation, testing and commissioning of PN16 rated Vertical Inline Split Coupled ( Long coupled Type ) single stage centrifugal pump each capable of delivering the specified flow rate comprising the following and complete as per specifications. Casing (Volute) - Cast Iron.Impeller - Gunmetal Bronze - Statically and Dynamically BalancedCasing Gasket - Confined Non Asbestos FiberPump Shaft - SS 316/416.Flush Line - Braided Stainless SteelMechanical Seal - Outside Balanced (the pump design shall meet the requirement of servicing / changing the mechanical seal without disturbing the pump shaft alignment) Motor Type - TEFC Squirrel Cage, Efficiency Class - IE3, Insulation - Class F, 415V ± 10% , 50Hz ± 5%, 3Ø AC Power Supply |
| 41 | The price includes loading/ unloading and shipment till site Including Insurance Charges ,Unloading at site,RCC Foundation, placement of PUMPs on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned pumps. |
| 42 | 384 USGPM * 18 M Head or as per actual at site with Min Efficiency. 75% (1Working + 1Standby) |
| 43 | Make :Xylem,Grundfoss,Armstrong |
| 44 | Cooling Tower ( CTI Certified) |
| 45 | Supply, installation, testing and commissioning of CTI Aproved standard Rectangular type FRP Induced Draught Counter flow cooling tower with Double Cell , Motors suitable for VFD's with necessory accessories, Motors shall be IP65 and efficiency of IE3 , FRP water basin, PVC fillings with integral louvers and drift eliminators, hot water distribution by gravity complete with statically and dynamically balanced axial flow Fans, Direct driven fans with TEFC induction motor and temperature sensor suitable for operation on 415 + 10% volts, 50 Hz. AC supply, suction screen, make up with float valve and quick fill arrangement, overflow and drain connections, suitable inspection ladder, access arrangement for cooling tower interior, MS supporting structure, anti-vibration mountings ,cement concrete foundation, steel/ mesonary supporting structure complete as per specifications as required. Design shall be as below ,IP 55 rated Locable Isolator Switch with cooling tower along with all Isolators for CT Complete in all repsect . |
| 46 | WBT : at 85º F |
| 47 | WB Approach : 2.77º C Maximum |
| 48 | Hot water IN : 97.5 ºF |
| 49 | Hot water OUT : 90ºF |
| 50 | Min Water Flow Rate : 384 USGPM |
| 51 | The price should include all clearance charges, unloading and shipment till site Including Insurance Charges ,Unloading at site,RCC Foundation, placement of Cooling Tower on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Cooling Tower. |
| 52 | Heat Rejection Capacity : 14,97,600 BTU/HR |
| 53 | Make : Mihir,Paharpur,Bell, Delta |
| 54 | AIR HANDLING UNITS |
| 55 | CEILING SUSPENDED/FLOOR Mounted AHU'S (AHRI/Eurovent Certified) |
| 56 | Double skin Low height & Low Noise Ceiling/FM mounted air handling units made of min 46+2mm thick Thermo-Accoustic panels ,Thermal Break Profile, extruded aluminum profiles with 0.6mm thick pre-coated GI Outer Sheet, 0.6mm thick Plain GI intermediate sheet inside layer with polyurethene foam (PUF) CFC Free insulation of density 40+-2 kg/m3 factory injected between them by injection moulding machine & 0.6mm Plain GI Perforated Inner sheet , filter section with G4 filter, coil section with 6 row chilled/Heating water coil, 22G SS304 drain pan with required thickness nitrile rubber insulation,Light, factory or at site mounted drain pump ,blower section with DIDW Aerofoil/ Backward/ Forward curved fans, Vibration isolators, Fan section access door, fire retardant canvass connection at fan outlet,Min IE-3 motor (TEFC type) and damper at the outlet of unit. All dampers shall be low leakage aluminum aerofoil design and suitable for manual / motorised operation.The selections for Ceiling mounted units shall be done considering the optimum Efficiency & Low Noise level with compact design of the units and AHRI/Eurovent Certified , complete as per specifications of following capacity: |
| 57 | CFM TYPE SP CC /TR |
| 58 | 4000 CS 40 6RD/12 |
| 59 | 5000 FM 40 6RD/15 |
| 60 | Make: Systemair,Edgtech,Flaktwood,Zeco |
| 61 | WATER COOLED CASSETTE ACS |
| 62 | Supply, installation, testing & commissioning of Water cooled Cassette Unit suitable for both heating/cooling with copper tube and aluminium finned cooling coil, low noise fan and motor with ON/OFF and 3 speed control and suitable for 1 phase, 230 + 6%V, 50 Hz electric supply, with cordless remote/corded control, fabric filter, drain pump, and decorative front grille. The Unit shall be complete with stainless steel duly insulated main and auxiliary drain pan. The unit shall be complete with electrical terminal strip, wiring in conduit upto thermostat box or any other advance technology. Unit shall have copper pipes for coil connection complete . The unit shall also have fresh air pocket provision. The front grill shall be 4 way type. The noise level at low speed shall be in the range of 38 to 42db & at high speed upto 45db. Noise levels are at a distance of 2M from the unit. (Note :Tonnage Variation allowed upto ±5%) : Note: Vendor should include the cost of of copper pipe connection upto 1m along with all accessories complete in all respect |
| 63 | 2.5 Tr Four way |
| 64 | EXPANSION TANK |
| 65 | Supply, Installation ,Testing and commissioning of MS.Open expansion tank with minimum thicknessof 3.0mm as per the specifications.The Open vessel expansion tank shall be complete with all accessories so as to make it ready for installation and commissioning on site.The tank shall be insulated with the approved method of insulation, and shall be complete with water make-up connection and system .The expansion tank will be supplied,Non return Valve ,Float valve,Ball Valves and interconnecting piping etc. |
| 66 | 2000 Ltr . Open Expansion Tank duly insulated and with all accessories. |
| 67 | AIR SEPARATOR |
| 68 | Supply,installation,testing and commissioning of Microbubble Air & Dirt Separator,with matching flanges, bolts, nuts & gasket, PN16 complete with flanged connection and as per the specifications as detailed earlier in the relevant section of specifications , and duly insulated with 50 mm thick TFF expanded polysterene and cladded with 26G aluminum sheet. |
| 69 | 125 mm Dia Air Separator , duly insulated. |
| 70 | Make : Honeywell, Sant,Anergy |
| 71 | Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. |
| 72 | SITC Water Flow Switches (Brass body) . Make : Anegy, RC |
| 73 | SITC Auto Air Vent Valve 1/2\\" . Make : Anergy, RC |
| 74 | PICV Valves |
| 75 | Supply, Installation, Testing & Commissioning of Insulated Two- way ball type pressure independent control valve with flanged end ISO7005-2, flow capacity as desired, Min.PN16, equal percentage flow characteristic, body GGG50 ductile iron with stainless steel ball. Non spring return rotary type modulating actuator, torque as required, close-off min pressure 700 kPa, power supply 24 V AC/DC, control signal 2-10 V DC, feedback signal 2-10 V DC, IP54. |
| 76 | 40 mm dia |
| 77 | 32 mm dia |
| 78 | 15mm dia |
| 79 | Make: Honeywell, Siemens,Danfoss,Belimo |
| 80 | Thermostat |
| 81 | SITC of Thermostat along with all accecorries and connecting wires between Thermostat and sesnsors & AHU Valves etc. complete in all respect |
| 82 | Brass Ball Valves |
| 83 | SITC of Brass Ball Valves of dia 25mm with Strainer |
| 84 | SITC of Brass Ball Valves of dia 25mm without Strainer |
| 85 | Make: RC, Anergy,Sant |
| 86 | VALVES/CONTROLS - PN-16 without Insulation , Make :Advance,Honeywell,Zoloto |
| 87 | Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. |
| 88 | BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. |
| 89 | 125 MM DIA |
| 90 | Y- STRAINERS (PN-16) |
| 91 | Providing and fixing in position the following Insulated Y-Strainers |
| 92 | 125mm dia |
| 93 | POT- STRAINER(PN-16) |
| 94 | Proiding and Fixing of Pot strainer with drain valve complete in all respect of following dia |
| 95 | 150 mm |
| 96 | SITC Water Flow Switches (Brass body) complete with copper control wiring at chiller outlet of each machine |
| 97 | AUTO AIR VENT |
| 98 | Supply, installation ,testing and commissioning of Auto Air vents,at the specified locations in the chilled water piping , alongwith isolation ball valves, as per approved makes |
| 99 | Auto air vent with isolating ball valves (15 mm dia) |
| 100 | CONDENSATE DRAIN PIPE |
| 101 | Providing and fixing and in position the following PVC pipes (Min. Thickness 3.0mm) for condensate drain duly insulated with minimum 6.0 mm 'O' Class Nirile rubber & duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers |
| 102 | 65 mm dia |
| 103 | 50 mm dia |
| 104 | 40 mm dia |
| 105 | 32 mm dia |
| 106 | 25 mm dia |
| 107 | Make : Diplast/Polypack/Astral/AKG |
| 108 | Factory Fabricated Spril Oval/Round |
| 109 | SITC of Factory fabricated Powder Coated Spiral Oval Duct Pre/site Insulated from Inside with 9.0mm thick Nitrile 'O' Class Insulation (payble separately) fabricated GSS Ducting complete with hanging arrangement of fasteners, GI threaded rods of sizes:. However The duct shall be fabricated at site for to make Collors/bends/plenums/suit pieces Only |
| 110 | GI Sheet thickness - 24 Gauge |
| 111 | GI Sheet thickness - 22 Gauge |
| 112 | (Make: Ductofab,Zeco,Pioneer Airtech (Sheet Make: Tata, Sail,Jindal) |
| 113 | Fresh Air/Exhaust Air Louvers |
| 114 | Supply, Installation, Testing and Commissioning of extruded aluminium louvres with frame bird screeen 50 mm pre-filter with frame, mounting arrangement etc. as per specifications and drawings. |
| 115 | Fresh Air/Exhaust Louvers |
| 116 | Make:SystemAir/Caryaire/Ravistar/Pinaire |
| 117 | MECHANICAL INSULATION |
| 118 | DUCT LINE ACOUSTIC TREATMENT |
| 119 | Supply, Installation, Testing and Commissioning of Acoustic lining inside ducts/plenum using open cell nitrile rubber foam having microban anti-microbial/ anti fungal product protection and of 160-180 kg / m³ density as per ASTM D3575, class 1 ratingn As per BS476,PART-7, cut to required sizes and to be stuck to the inside of duct surfaces with adhesive as approved by the manufacturer. (Rubber based solvent). as per specifications |
| 120 | 15mm thick sound board for Floor Mounted AHU's |
| 121 | 10mm thick sound board for CS AHU's |
| 122 | Make :K Flex,Armacell,Aerofoam |
| 123 | DUCT LINE THERMAL INSULATION(Inside Conditions) |
| 124 | SITC of Physically / Chemically crosslinked polyethylene foam, with factory reinforced alupet foil facing, ANTI MICROBIAL/ANTI FUNGAL,HFC & CFC free , Negligible VOC level with Class O fire properties,with very low fire propagation of < 5.5 and passing E-84 at < 25/50, as per technical specification, the density of the foam should be not less than 25-30kg/m3 and the maximum thermal conductivity K should be 0.032W/mK@ 23 Deg C , the permeability resistance factor u shouldn't be less than 14000. The product shall have temperature range of –20oC to 115oC |
| 125 | 9mm thick |
| 126 | Make :K Flex,Armacell,A Flex ,Aerolam |
| 127 | ASSOCIATED ELECTRICAL WORKS |
| 128 | Main Electrical Panel |
| 129 | Main Electrical Panel (CPRI Approved manufacturer at leat 70 K) |
| 130 | Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom/Top of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness., The panel manufacturer shall have min 70 KA CPRI Certification |
| 131 | The panel drawing shall be approved before taking up the fabrication and Shall have compitable BMS for future requirment. |
| 132 | Main A.C. Panel |
| 133 | Incomer |
| 134 | INCOMING SUPPLY : MCCB 500-630 Amps 65 KA 4 PoleMicro processor based Adjustable type with Rotary Mechanism & all Protections along with spreader links,etc : 1 No. |
| 135 | Multi Fuction VAF/VIF Meter (96mmX96mm Size) ,Indication Lamps LED Type RYB, Control MCB SP for Control (3 Nos),CT's 600/5 (3 Nos) and Control Terminal (8.0 Nos.) etc. |
| 136 | Outgoing |
| 137 | 2 No. 125-160 Amps TP+NL MCCB with adujustable release 50 KA with ROM & Spreader links S/c, O/L & other protections outgoing for chillers. |
| 138 | 1 Nos. 200-250 Amps TP+NL MCCB with adustable release 50 KA with ROM & Spreader links S/c, O/L & other protections for 100 KW Hot water generator (interlocking electrically done to operate either chillers or HWG at a time) |
| 139 | 2 Nos. 0-63 Amps MCCB 25KA TP+NL with ROM & Links outgoing for Primary chiller water pumps (2 Working & 0 Standby) |
| 140 | 2 Nos. 0-63 Amps MCCB 25KA TP+NL with ROM & Links outgoing for condenser water pumps with upto 15 KW Star Delta starter (2 Working & 0 Standby) |
| 141 | 2 No. 0-63 Amps 25 KA MCCB with ROM & Links outgoing for Cooling Tower motor (1 DOL starters on each cooling tower of upto 7.5 KW each with incomer MCB TP seprate for each starter) |
| 142 | 2 Nos. 63-100 Amps 36 KA MCCB TP+NL outgoing with ROM & Links |
| 143 | All starter shall have following accessories : |
| 144 | 1 No. overload relay |
| 145 | 1 No. Ammeter with CTs. |
| 146 | 1 No. single phase preventer |
| 147 | 2 Nos. ON/OFF indicating lights |
| 148 | 2 Nos. ON/OFF push buttons |
| 149 | Hardware (PVC Channels/MCB Channels/Fibre- Glass/Gaskits/Sleeves/nuts/Bolts/washers/cooling fans/etc) |
| 150 | Complete Wiring inclusive of thimbles,etc |
| 151 | Unloading at site, RCC foundation ,placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel. |
| 152 | Sub Panel for AHU Motors up to 5.5 KW |
| 153 | SITC of Wall mounted sub panel boards for AHUs, Blower with switch, starters, lamps inter connections, current operated single phase preventer, A/M switch etc. as per specifications and drawings and as required. |
| 154 | 1 No. incoming upto 32Amps 4 pole TP+NL MCB with Digital Mutli function Meter Class 1.0 with CT of suitable rating |
| 155 | RYB Indicators |
| 156 | 2 Nos. Push Buttons On/Off |
| 157 | 1No. single phase preventor |
| 158 | 1 nos. DOL starter with Power contactor and MPCB as incomer of the starter with SPP with Digital Ampere Meter Class 1.0 with CT of suitable rating |
| 159 | 1 No MCB DP |
| 160 | Panel Make : Adlec/Siemens/Tricolite/Unitech Power System/Vrindavan Electricals |
| 161 | Sub Distribution Panels for AHU's |
| 162 | SITC of panel board made of 1.6mm for non load bearing /2.0 mm thick steel sheet for non load bearing sections duly powder coated complete with Metering, indicating lights, CTS contactors, A/M Switch for remote controls operation complete as per specifications and drawings and as required.The panel manufacturer shall have min 70 KA CPRI Certification |
| 163 | Incomer |
| 164 | 1 Nos. 100-125 Amps 36 KA MCCB TP+NL with ROM & Links |
| 165 | 1 No. 400 Amps aluminium conductor bus bar duly sleeved |
| 166 | 1 no. Multifunction meter with CTs as per requirment |
| 167 | 3 Nos. phase indicating lamps |
| 168 | Outgoing |
| 169 | 7 Nos MCB suitable for 1.1 to 3.7 KW or suitable DOL Starter for AHU having contactors, LED indicators for on/off , O/L Relay, SPP, etc. as per coordination chart |
| 170 | 1 Nos MCB suitable for 5.5 to 7.5 KW or suitable DOL Starter for AHU having contactors, LED indicators for on/off , O/L Relay, SPP, etc. as per coordination chart |
| 171 | 1 nos MCB TPN 32 Amps 'C\\" Curve Spare and complete Wiring inclusive of thimbles,etc |
| 172 | Hardware ( PVC Cahnnels/MCB Channels/Fibre- Glass Gaskets/Sleevs/nuts/bolt/washers/cooling fans etc Including complete wiring,thimbles etc. |
| 173 | Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel.The panel drawing shall be approved before taking up the fabrication from EIC |
| 174 | Panel Make : Adlec/Siemens/Tricolite/Unitech Power System/Vrindavan Electricals |
| 175 | CABLING (POWER |
| 176 | Power Cabling and Earthing |
| 177 | Supply, installation, testing & commisioning of Aluminum/CU conductor cables PVC sheathed, armoured cables of 1.1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc. |
| 178 | 3.5Cx300 Sqmm Al |
| 179 | 3.5Cx240 Sqmm Al |
| 180 | 3.5Cx150 Sqmm Al |
| 181 | 3.5C x70 Sqmm Al |
| 182 | 4C x35 Sqmm Al |
| 183 | 4.0Cx16 SqmmAl |
| 184 | 4.0Cx10 Sqmm Al |
| 185 | 4.0Cx 06 Sqmm Al |
| 186 | 4.0Cx04 Sqmm CU |
| 187 | 4.0Cx2.5 Sqmm CU |
| 188 | 2Cx04 Sqmm (Cu Conductor flexible) |
| 189 | Make : Havell's,Ecko,Finolex,Polycab |
| 190 | Control Cabling |
| 191 | Supply, installation, testing & commisioning of Copper conductor , PVC insulated, PVC sheathed armoured cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU to Control Consol Panel |
| 192 | 3C x 1 Sqmm |
| 193 | 2C x 1 Sqmm |
| 194 | Make : Havell's,Ecko,Finolex,Polycab |
| 195 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with twonumbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 196 | 450mm(W) x50 mm(D) and 2.0 mm Thickness |
| 197 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 198 | 450 mm width X 50 mm depth X 2.0 mm thickness |
| 199 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenientsections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 200 | 450mm(W) x50 mm(D) and 2.0 mm Thickness |
| 201 | 300mm(W) x 50 mm(D) and 1.5 mm Thickness |
| 202 | 50mm(W) x 50 mm.(H) and 1.5 mm Thickness |
| 203 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 204 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required |
| 205 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 206 | Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 207 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required |
| 208 | INSULATED CHILLED WATER PIPING (expandedpolystrene insulation) |
| 209 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.),cut to required length, and installed with welded joints (USE RECTIFIER AS SPECIFIED), duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. |
| 210 | Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. (Insulation Make : Beardsell, Lloyed) |
| 211 | 125 MM Pipe DIA with 50 mm Thick Insulation |
| 212 | 100 MM Pipe DIA with 50 mm Thick Insulation |
| 213 | 80 MM Pipe DIA with 50 mm Thick Insulation |
| 214 | 65 MM Pipe DIA with 50 mm Thick Insulation |
| 215 | 50 MM Pipe DIA with 50 mm Thick Insulation |
| 216 | 40 MM Pipe DIA with 50 mm Thick Insulation |
| 217 | 32 MM Pipe DIA with 50 mm Thick Insulation |
| 218 | 25 MM Pipe DIA with 50 mm Thick Insulation |
| 219 | Pipe Make : Tata, Hisar Jindel |
| 220 | SITC of Insulated VALVES/CONTROLS - PN-16 including cost of MS Flanges as per the Table(Make: Advance, Sant, Zoloto) |
| 221 | Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. |
| 222 | BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating for chilled water /hot water circulation as specified. |
| 223 | 125 MM DIA |
| 224 | 100 MM DIA |
| 225 | 80 MM DIA |
| 226 | 65 MM DIA |
| 227 | 50 MM DIA |
| 228 | BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. |
| 229 | 100 MM DIA |
| 230 | 80 MM DIA |
| 231 | 65 MM DIA |
| 232 | 50 MM DIA |
| 233 | NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. |
| 234 | 100 MM DIA |
| 235 | Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. |
| 236 | 80 MM DIA |
| 237 | 50 MM DIA |
| 238 | Providing & Fixing in position the industrial type pressur gauges with gun metal/brass valves complete as required |
| 239 | Make : Guru,Fiebig |
| 240 | Providing & Fixing in position the mercury in glass industrial type thermometers |
| 241 | Make : Guru,Fiebig |
| 242 | CONDENSOR WATER PIPING |
| 243 | Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. |
| 244 | Note:-i)The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. ii) For under ground pipe : The pipe will be covered by applying 2-4mm thick Tarfelt sheet with required Adhesive ,Accessories etc |
| 245 | 150 MM DIA |
| 246 | 125 MM DIA |
| 247 | Make : Tata, Jindel Hisar |
| 248 | VALVES/CONTROLS - PN-16 without Insulation , Make :Advance, Sant,Zoloto |
| 249 | Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. |
| 250 | BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet& O - ring & PN 16 pressure rating as specified. |
| 251 | 150 MM DIA |
| 252 | 125 MM DIA |
| 253 | NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation as specified. |
| 254 | 125 MM DIA |
| 255 | Ducting |
| 256 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, Splitler dampers,vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required and shall also confirm to the BIS specifications. |
| 257 | Thickness 0.63 mm sheet |
| 258 | Thickness 0.80 mm sheet |
| 259 | Thickness 1.00 mm sheet |
| 260 | Sheet Make: Tata, Sail,Jindal |
| 261 | Grilles/Diffusers/Dampers |
| 262 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications |
| 263 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills(curved/Flat) with aluminium volume control dampers as per specifications |
| 264 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required |
| 265 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 266 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. |
| 267 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. |
| 268 | Fire damper |
| 269 | Actuator Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 days