Tender For General-Proj No. : 287/2026_27 : Thrikkakara Municipality-Kakkanad Community Hall Renovation -General Civil Work
Tender Value
9.46 Lakhs
Estimated cost
Bid Submission
08 Jul 2026
3 days left
EMD
23660
Bank guarantee accepted
Document Fee
2090
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Proj No. : 287/2026_27 : Thrikkakara Municipality-Kakkanad Community Hall Renovation -General Civil Work
BOQ
| Sl. No. | Item Description |
| 1 | Resetting |
| 2 | OD517162/2025-2026:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in charge |
| 3 | 4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material |
| 4 | OD517175/2025-2026:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-in-charge. (Modified DAR item 16.84) |
| 5 | OD518660/2025-2026:Providing and Laying of Interlocking Concrete Block Pavements using 80 mm M40 hydraulic blocks of approved size, design & shape, laid in required pattern over and including a compacted bed of 6mm stone aggregate of 50mm average thickness, etc. all complete as per the direction of Engineerin-charge. |
| 6 | Maintenance |
| 7 | 15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar |
| 8 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | 7.6.1:Coursed rubble masonry (first sort) with hard stone in foundation and plinth with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 11 | 11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm. |
| 12 | 15.13.2:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area beyond 3 sq. metres |
| 13 | 9.56.1:Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finishedbutt hinges with necessary screws etc. complete : 125x90x4.00 mm |
| 14 | 15.12.2:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area beyond 3 sq. metres |
| 15 | 9.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). |
| 16 | 15.52:Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead |
| 17 | 17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 18 | 15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 19 | 11.39:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 20 | 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 21 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 22 | 13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 23 | OD518322/2025-2026::Designing, fabricating,testing and installing Curtain Wall with Aluminium CompositePanel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding INCLUDINGaluminium base frame work in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour andshade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts,bolts, washers, cleats, weather silicone sealant, backer rods etc.with aluminium composite panel cladding till the handing over of the building for occupation. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per theapproved shop drawings and as directed by the Engineer-in-Charge.However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.OD84/21-22 - Modified data 25.7 |
| 24 | 26.26.2:Providing & fixing false ceiling at all heights with GRG (Glass Fibre ReinforcedGypsum) false ceiling tiles of Size 595x595 mm of approved texture, designand patterns having moisture content less than 2%, humidity resistance of99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476(part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontallevel suspended on inter-locking metal T-Grid of hot dipped galvanised ironsection of 0.33mm thick (galvanized @ 120 grams per sqm including bothsides) comprising of main-T runners of size 15x32 mm of length 3000 mm,cross - T of size 15x32 mm of length 1200 mm and secondary intermediatecross-T of size 15x32 mm of length 600mm to form grid module of size 600 x600 mm, suspended from ceiling using galvanised mild steel items (galvanizing@ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners,6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape leveladjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition withthe help of plastic rawl plugs at 450 mm center to center and 40 mm long drywall wood screws. The work shall be carried out as per specifications, drawingand as per directions of the Engineer-in-Charge.With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 25 | 10.16.2:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 26 | OD519730/2025-2026:OD166546/2024-2025od1283429/2021_2022 :Supply and fixing 3D Acrylic letters ENGLISH LETTERS 25-30cm or MALAYALAM LETTERS 20-25cm for name board Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender