Drinking Water Supply and Sanitation Local Bodies Closing in 12 days TDR #56249799

Tender For Construction Of Indoor Gym Shed, Shuttle Court, Mini Basketball Court, Compound Wall (South Side), Providing cement concrete Road, Fencing And Laying Reinforced Cement Concrete Pipe In Approach Road At Ward No. 12 Bagalur Hudco Park In Hos

Issued by Local Bodies · Krishnagiri, Tamil Nadu
Tender Value
22.60 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
12 days left
EMD
22600
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Krishnagiri → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Indoor Gym Shed, Shuttle Court, Mini Basketball Court, Compound Wall (South Side), Providing cement concrete Road, Fencing And Laying Reinforced Cement Concrete Pipe In Approach Road At Ward No. 12 Bagalur Hudco Park In Hosur City Municipal Corporation

BOQ

Name of Work:- Construction of Indoor Gym Shed, Shuttle Court, Mini Basketball Court, Compound Wall (South Side), Providing CC Road, Fencing and laying RCC pipe in approach Road at Ward No. 12 Bagalur HUDCO Park in Hosur City Municipal Corporation
Sl. No. Item Description
1Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the departmental officers. for footing
2Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the departmental officers. for plinth beam
3Plain Cement Concrete 1:5:10 (one cement, five fine aggregates and ten coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
4Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed Centering for soffits of RCC Column
5Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed Centering for soffits of RCC Slab
6Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed Centering for soffits of RCC Slab
7Supply and Fixing of Cut Stone Pillar of size 0.15 x 0.15 x 2.1m including cost of material, labour charges and all other incidental charges etc., complete as per standard Specification.
8Supplying and Fixing of Barbed Wire - 10 Gauge - Two Ply and Four Pronged (Galvanised) wire fencing 5 No's of Horizontal and Vertical wire 11 No's 30 Cm C/c including cost of Barbed wire 12Kg etc., Complete as per Standard Specification
9Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications.
10Plain Cement Concrete 1:2:4 (one cement two fine aggregates and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
11Supply and delivery of 300mm dia RCC NP2 Pipe including cost of material, labour charges and all other incidental charges etc., complete as per standard Specification.
12Supply and delivery of 300mm dia RCC Collor including cost of material, labour charges and all other incidental charges etc., complete as per standard Specification.
13Random rubble masonry in cement motor 1:5 (one Part of cement, Five part of Crushed Stone Sand (M- Sand)) mix using all granite stones and bond stones for foundation and basement from approved quarry including watering, curing, and labour charges etc., completed as per standard specification
14Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.50 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) for Basement
15Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors
16Vibrated Cement Concrete M20 (Design mix) using 20 mm ISS HBG graded metal including cost and conveyance of all materials to site form work and centering soft water labour charges for mixing, transporting, vibrating and compacting finishing and curing concrete, working at heights, hire charges for Hire charges for Tools and plants, including all other incidental charges, etc., complete as per standard specifications for CC Pavement
17Brick work in CM 1:5 (one cement & five M sand) using II class ground moulded bricks of size 9\\"X43/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification for Basement
18Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
19Plastering with cement mortar (1:3) 20mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
20Supply and fixing of M.S Grills for Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
21Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification
22Fabricating supplying and fixing of pre painted galvanium colour sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers.
23Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
24Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
25Outdoor Granite Bench: Supplying, erecting and fixing outdoor granite bench of 3 seater without back rest. Bench shall consist of 2 nos. L shaped bases support and size of L 1.2mx W 0.38mx H 0.45mm
26Supplying and fixing in position C.I.Manhole covers (light or heavy duty) of 60 X 60cm in size in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), of best approved quality and as per standard specifications etc.,complete.
27Supply and delivery of clear water vertical wet type 2HP submersible pump conforming toIS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable ofdischarging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 %
28Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (4 points per coil)
29Wiring with 2 x 1.5sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x 100 x 113 mm TW switch box for 5A 3 pin non inter locking Wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 1.5sq.mm copper wire for open PVC plug point
30Wiring with 2 x 4sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 113 mm TW switch box for 15 A 3pin non inter locking wall socket with15A flush type switch with painting of suitable colour with continuous earth wire connection of 4sq.mm copper wire for open PVC power plug point
31Supply and fixing of 1200 mm (48\\") sweep AC ceiling fan complete with stepped electronic 300W regulator, with 1 metre down rod with fan clamp with side plates and cross arm of size 450 mm (18\\") (SD - 106)
32Supply and Fixing of 18 W LED Tubelight for T8 Fitting Single side (15- e) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56249799
AUTHORITY Local Bodies
TENDER VALUE 22.60 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Construction Of Indoor Gym Shed, Shuttle Court, Mini Basketball Court, Compound Wall (South Side), Providing cement concrete Road, Fencing And Laying Reinforced Cement Concrete Pipe In Approach Road At Ward No. 12 Bagalur Hudco Park In Hosur City Municipal Corporation
Basic Detail
Tender No 12073/2024/E1 Hosur City Municipal Corporation
Bidding Type Tender
Location
City Krishnagiri
State Tamil Nadu
Key Dates
Publish Date 01 Jul 2026
Submission Date 14 Jul 2026
Open Date 14 Jul 2026
Finance
Tender Value 22.60 Lakhs
Tender Fee Ref. Documents
EMD 22600
Exemption Not Available
Document List
BOQ_821570.xls
ff5a3e56-bd45-4684-9857-52ba6ce05682.html
Tendernotice_1.pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Jul 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_821570.xls

html

ff5a3e56-bd45-4684-9857-52ba6ce05682.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders