Tender For Construction Of The Science Faculty Building At Savitribai Phule Government Post Graduate College, Chakiya, In District-Chandauli.
Tender Value
7.60 Crore
Estimated cost
Bid Submission
22 Jul 2026
17 days left
EMD
15.20 Lakhs
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandauli → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of The Science Faculty Building At Savitribai Phule Government Post Graduate College, Chakiya, In District-Chandauli.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(Partll 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shallbe as follows: (1) Treatment for masonary & foundation 5 liters per/100 sqm.(2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4) Treatment junction of wall and the floor 7.5 liters/100 sqm (5)Treatment of soil along external perimeter of building 7.5liters/100sqm. (6) Treatment of soil under apron along external perimter 5 liters/100 sqm. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Brick work with common burnt clay (non modular) bricks of class designation 150 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 12 | Brick work with common burnt clay (non modular) bricks of class designation 150 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) brick 115mm thick |
| 13 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. b)double leaf 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws + Extra for cutting rebate in flush door shutters . |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) Single leaf 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 15 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40*40*5 mm, joints mitred and welded by angle iron 40*40*5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 16 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingProviding & fixing of door / windows grill. |
| 17 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 18 | Fixing of M.S chaukhats in position. |
| 19 | 15 mm thick plinth plaster [1 cement : 4 coarse sand] |
| 20 | 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 21 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand) |
| 22 | Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials, labour T & P etc for proper completion of the work. |
| 23 | Providing and laying Vitrified tiles in floor in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to 1S:15622, of approved brand & manufacturer, in all coloursand shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarsesand) jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cutwith the zero chipping diamond cutter only . Laying of tiles will be donewith the notch trowel, plier, wedge, clips of required thickness, levelingsystem and rubber mallet for placing the tiles gently and easily. |
| 24 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 25 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 26 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 27 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 25 mm thick with 25 mm nominal size stone aggregate |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 29 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 30 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 31 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 32 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer As above but every coat after the first coat |
| 33 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes |
| 34 | Providing Oxidised Sliding Bolts 16 mm dia with nuts and 250 mm long. |
| 35 | Providing Oxidised Tower Bolt with 10 mm dia and screw. (i) 250 mm long |
| 36 | Providing Oxidised Door Handles with screws 125 mm long. |
| 37 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 38 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to |S : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 39 | Construction of drain of size of size 150 x 150 mm along with apron including excavation,base concrete 1:4:8 in thickness of 7.5cm of and brick work in foundation 1:4( 1 cement : 4 coarse sand) and brickwork in half brick thick in foundation 40mm thick cement concrete flooring and base 20mm thick plaster finished with neat cement. |
| 40 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick |
| 41 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 42 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing |
| 43 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels |
| 44 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 45 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) |
| 46 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 47 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Ordinary cement without any pigment. |
| 48 | 1:2:4 (1 Cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 49 | Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge.With decorative veneering on one side and commercial veneering on other side |
| 50 | Providing & Fixing special quality chromium plated brass cupboards locks with six levers including necessary screws etc. complete(best make of approved quality) of size 40mm |
| 51 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 52 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 53 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 54 | Tile brick masonry work 5 cm thick with common burnt clay F.P.S. (non modular) tile bricks of class designation 10 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth and upto floor five level. |
| 55 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 Itr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sgm |
| 56 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases of columns, etc. for mass concrete |
| 57 | Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 58 | Centering and shuttering including strutting, propping etc. and removal of form work for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 59 | Centering and shuttering including struting , proping etc and removal of form for : Suspended floors, roofs, landings, balconies and access platform. |
| 60 | P/F Green Board (Melamine Green) Size 6 feet x 4 Feet) Frame : Premium Aluminium Made : Melamine & Light Board |
| 61 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 62 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. |
| 63 | 2 X 2.5 sq . mm + 1 X 2.5 sq. mm earth wire |
| 64 | 2 X 4 : sq. mm + 1 X 4 sq. mm earth wire |
| 65 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 66 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 67 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 68 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 69 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 70 | 25 mm |
| 71 | 32 mm |
| 72 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 73 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 74 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 75 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 76 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 77 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 78 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 79 | Supply of fire buckets 4 No. in each set duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. Fire buckets shall be painted red from outside and white from inside with additional handle at the bottom and suitable for outdoor installation. |
| 80 | Supply of tool kit with 1 pair 11 KV rubber hand gloves as directed by Engineer Incharge. |
| 81 | Supplying & fixing standard shock treatment charts in English & Hindi duly framed and covered with glass as directed by Engineer Incharge. |
| 82 | Providing Safety mat made of elastomeric polymers Material (Class B) 1.2 M wide with thickness 2.5 mm to withstand 12KV dielectric strength AS PER relevant IS Code |
| 83 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: 2 Pair (4 core) |
| 84 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 85 | 4 Module (125mmX75mm) |
| 86 | 6 Module (200mmX75mm) |
| 87 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 88 | Telephone socket outlet |
| 89 | TV socket outlet |
| 90 | Telephone Tag Box 10 pair |
| 91 | 6U Data Rack |
| 92 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) |
| 93 | 12 -15 watt |
| 94 | 18 watt |
| 95 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).150 Watt |
| 96 | Supply and fixing of LED Tube Light with heavy duty Metal Box type Mirror Light fitting 10 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended Complète in all respect |
| 97 | Supply and fixing of wall bricket 10 watt LED bulb Polycarbonate tube light complete Including tube suitable for both surface & suspended Complète in all respect |
| 98 | Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 36 Watt |
| 99 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 100 | Supply and fixing of Ex-Fan 200mm Complète in all respect |
| 101 | Supply and fixing of wall fan Complète in all respect |
| 102 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
| 103 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 104 | 4 Way Double door |
| 105 | 6 way Double door |
| 106 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 107 | 40 amps 4P MCB |
| 108 | 63 amps 4P MCB |
| 109 | DP MCB |
| 110 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door |
| 111 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 112 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 113 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. without charcoal/ coke and salt as required. |
| 114 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 115 | Supply and laying of 25mm x 5mm copper strip at 0.50 meter below ground as strip earth electrode including connection / terminating with nut ,bolt spring washer etc. jointing shall be done by overlaping and with 2 sets of brass nut bolt&spring washer spaced at 50mm) |
| 116 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 117 | Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. |
| 118 | Jointing copper/G.I. tape (with another copper/GI tape, base of the finial or any other metallic object) by riveting/ nut bolting/ sweating and soldering etc as required. |
| 119 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 120 | Fixing of copper/ G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 121 | Supply and Laying of Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 150 sq. mm 3-1/2 core |
| 122 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kv grade as required. 150 sq. mm 3-1/2 core |
| 123 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray With perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 124 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 125 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 126 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 127 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 128 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 129 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 130 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 131 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 132 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 133 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 134 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 135 | 2no. 500 A, MCCB, 4 Poles, Fixed Manual, 36 KA, Microprocessor based release for O/L,S/C & E/F Protection 36 kA at 415 volt with PLC Logic ,Auto sharing & Auto Load Management including auto start / auto stop of DG Sets, Incomer's, ACB's Buscoupler switching, interlocking complete with following switchgear & software & hardware.On, OFF, TRIP lamps - R/Y/B indicating lamps- MFM CL 1.0 (EM-6400NG) Outgoing 40 Amp. 10KA FP MCB 8 No.63 Amp. 10KA FP MCB 8 No. 63Amp. 25KA DP MCCB 4 No. 125Amp. 25KA FP MCCB 4No. 320Amp. 25KA FP MCCB 1No.INSTRUMENTS 1 set of multifunction of meter with RS 485 port. 1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker). 1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 1 Sets auto trip indicating lamp . Energy meter is supplied seperately cost of the meter as approved in department. 3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 3 Sets auto trip indicating lamp . Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. RELAYS AS PER SLD Incomer (Workshop Panel) |
| 136 | 1no. 320 A, MCCB, 4 Poles, Fixed Manual, 25 KA, Microprocessor based release for O/L,S/C & E/F Protection On, OFF, TRIP lamps -R/Y/B indicating lamps- MFM CL 1.0 (EM-6400NG) Outgoing 40 Amp. 10KA TP MCB 12 No.63 Amp. 10KA TP MCB 10 No.16 Amp. 10KA SP MCB 08 No.INSTRUMENTS 1 set of multifunction of meter with RS 485 port.1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).1 Sets auto trip indicating lamp . Energy meter is supplied seperately cost of the meter as approved in department. 3 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker). 3 Sets auto trip indicating lamp . Note: All outgoings should have ammeter and RYB indications with backup MCB as indicated in single line diagrams. RELAYS AS PER SLD |
| 137 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 138 | Providing and fixing white vitreous china pedestal type water closet ( European type W.C. pan ) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. |
| 139 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. |
| 140 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm |
| 141 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Felxible pipe b) 40mm dia |
| 142 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 143 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 144 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 145 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore |
| 146 | Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
| 147 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. a) 15mm dia nominal dia. |
| 148 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 149 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 150 | Providing and fixing of upvc SWR ring fit pipe of class B of ISI mark Confirming to IS code 13592 (make prince, supreme finolex) in internal works of toilet and RWP etc. including fixing with rubber rings etc. including cost of all material, labour etc. complete.including excavation & trenches etc complete a) 110mm diameter |
| 151 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 152 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali |
| 153 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735 |
| 154 | Size 75/90 mm |
| 155 | Size 110 mm |
| 156 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.a) 110mm |
| 157 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 158 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 159 | 20mm dia nominal outer dia pipes |
| 160 | 25mm dia nominal outer dia pipes |
| 161 | 32mm dia nominal outer dia pipes |
| 162 | 40mm dia nominal outer dia pipes |
| 163 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. |
| 164 | 16mm dia nominal outer dia pipes |
| 165 | 20mm dia nominal outer dia pipes |
| 166 | 32mm dia nominal outer dia pipes |
| 167 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.45 cm length i) 15mm nominal bore |
| 168 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore |
| 169 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore |
| 170 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 893115mm nominal bore |
| 171 | Providing and fixing gun metal gate valve with wheel of approved quality(screwed end).. |
| 172 | 25mm dia nominal bore |
| 173 | 32mm dia nominal bore |
| 174 | 40mm dia nominal bore |
| 175 | Providing and fixing gun metal gate valve with wheel of approved quality. a) 20 mm dia nominal bore |
| 176 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 177 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. For 500 litres |
| 178 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. |
| 179 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 900x800mm and 500mm deep including CI cover with frame With FPS bricks of class designation 75 |
| 180 | Extra for depth of man hole size 900x800mm |
| 181 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 900x1200mm and 1 mtr deep including CI cover with frame With FPS bricks of class designation 75 |
| 182 | Extra for depth of man hole size 900x1200mm |
| 183 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard designWith 20x20 mm square bar |
| 184 | Providing and fixing of UPVC SWR ring fit pipe of class B of ISI mark Confirming to IS code 13592 (make prince, supreme finolex) in internal works of toilet and RWP etc. including fixing with rubber rings etc. including cost of all material, labour etc. complete including excavtion trenches etc comp. b) 160mm diameter |
| 185 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe |
| 186 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required Size 600x450x200 mm |
| 187 | Providing and fixing Chemistry Lab Lpg Gas Pipe Lines with wheel of approved quality.a) 20 mm dia nominal bore |
| 188 | Supply, Installation, Testing and Commissioning of Interactive Screen 86\\" with IPS Panel technology, Back Light Type- Direct LED, Aspect Ratio- 16: 9, Resolution- 3840*2160 (UHD). Brightness- 350 cd/m2, Contrast Ratio- 1200 :1, Response Time- 8ms, Surface Treatment- Hard Surface, Anti scratch, Anti glare, Orientation- Landscape, Storage 32 GB, RAM 3 GB, Processor- Dual Core A73+Deau Core A53, Inputs- HDMI (3), VGA (1), Audio In, USB 3.0 (3), OPS, Weight- 67.45 Kg, Power Consumtion- 370W/500W, Speaker (10W*2), Operative System Supports- Windows 7 /8 /10 /Windows XP / Linux / Mac / Android, Multi Touch Points- Max 20 Points. The OEM shall have uL Certified display. make Akai 86'' Interactive flat panel |
| 189 | Supply, Installation, Testing and Commissioning of OPS which shall be with Core i7 Processor. It shall have 8 GB Ram or more. It shall have 1 TB HDD/512GB SSD or better. It shall have 2x USB3.0 interface, 2 x DP interface, 1x 10/100/1000 LAN interface. It shall have 2x USB2.0 Interface. It shall have genuine windows 11 professional series Operating System or better. Supplied with Recording & Streaming software with 1 year subscription. Open Pluggable Specification |
| 190 | Supply, Installation, Testing and Commissioning of Digital podium helps to simplify events by incorporating various multimedia and AV devices in single platform.It has in-built 21.5\\" touch screen monitor with with HDMI & VGA Interface. Hydrolic Up/Down buttons for touch monitor height adjustment, Key Board/Mouse tray and sliding top tray for Laptop. Single power button to On/Off the Digital Podium with Light indicator. Single Lock System to Lock the Keyboard tray, Door lock and the Slider. Equipments rack space. A 6 port PDU & a cooling fan.Digital Podium |
| 191 | Supply, Installation, Testing and Commissioning of Wireless handheld Microphone which shall have Frequency Modulation. It shall have a S/N ratio of ≥ 109 dBA or better. It shall have THD of ≤ 0.8% or better. It shall have frequency response of 80 to 18,000 Hz (–3 dB) or better. It shall have Balanced XLR Audio output and Unbalanced Audio Output. It shall have Operating Time of 6 Hours or more. It shall have power consumption of less than 10W. It shall have 40 Adjustable Frequencies. It shall have cardioid Polar Pattern. It shall support Max SPL: 125dB (THD>3%) or better. It shall have receiving distance of 40 meters or more.It shall have CE, FCC, RoHS, ISO9001, ISO27001, ISO50001 & ISO14001 Certifications, All certificates need to attached. Wireless Handheld Microhone |
| 192 | Supply, Installation, Testing and Commissioning of Wireless Laple Microphone which shall have Frequency Modulation. It shall have a S/N ratio of ≥ 109 dBA or better. It shall have THD of ≤ 0.8% or better. It shall have frequency response of 80 to 18,000 Hz (–3 dB) or better. It shall have Balanced XLR Audio output and Unbalanced Audio Output. It shall have Operating Time of 6 Hours or more. It shall have power consumption of less than 10W. It shall have 40 Adjustable Frequencies. It shall have Omni Directional Polar Pattern. It shall support Max SPL: 125dB (THD>3%) or better. It shall have receiving distance of 40 meters or moreIt shall have CE, FCC, RoHS, ISO9001, ISO27001, ISO50001 & ISO14001 Certifications, All certificates need to attached. |
| 193 | Supply, Installation, Testing and Commissioning of Audio Digital Signal processor with inbuilt AEC. 4 AEC enabled Mic/Line Inputs Channels,4 Line Outputs Channels, Input Interface-Balanced 3-Pin Phoenix Mic/Line Interface,Output Interface-Balanced 3-Pin Phoenix Line Interface,Control Interface-RS-232, RS-485, RJ-45(10/100 Base-T Ethernet Connector for IP-Based PC Software, Host Control & Third-Party Controller), ,Dante Interface-Level-1: 1000 Base-T Ethernet Connector for Up to 24 (12x8) Channel Dante Network Audio UC Interface-1x USB Type-A Audio Interface,Max Input Level-+ 12dBu/Line, -9 dBu/Mic,Input Impedance-Balanced 9.4 KΩ,Phantom Power-+ 48 VDC for Individual Input,+ 48 VDC for Individual Input. Certificate: CE, FCC, BIS, UL etc complete with standard accessories as required. Audio Digital Signal Processor |
| 194 | Supply, Installation, Testing and Commissioning of It shall be 240 Watts or more Mixing Amplifier. It shall have Microphone frequency response of 80Hz- 17000Hz or better. It shall have a Line Frequency Response of 80 Hz-18000 Hz or better. It shall have minimum impedance load bridged of 4 ohms per channel. It shall have 4 or more balanced microphone inputs. It shall have up to 48V phantom power individually for four microphone inputs with On/Off. It shall have 2 or more line inputs. It shall have 1 Line output or better. It shall have input sensitivity of ± 5 mV/ 600Ω for balanced Microphone inputs. It shall have input sensitivity of 350mV/10kΩ for unbalanced Aux input. It shall have an output sensitivity of 1000mV/470Ω for record output. It shall have 100V line as well as 4 to 16 ohm impedance output. It shall have THD of >0.1% at 1 KHz, 1/3 rated Power or better. It shall have Microphone input overload of fifteen db or greater. The microphone inputs shall override over other audio inputs by 30 dB attenuation via switch. It shall have a gain control of ± 2.5mV to ± 75mV@ 30dB. It shall have a cross talk of ≥ 50 dB or better. It shall have high temperature, overload and short circuit protection. It shall get operated from AC as well as DC.It shall have CE, FCC, RoHS, ISO9001, ISO27001, ISO50001 & ISO14001 Certifications, All certificates need to attached.Audio Mixing Amplifier. |
| 195 | Supply, Installation, Testing and Commissioning of Two Way Wall Mount Speakers which shall have 5.25\\" LF Driver and 1\\"HF Driver. It shall have frequency response of 60 Hz to 20,000. It shall have 4 Ohm impedance as well as 70V,100V tapping. The speaker shall have a maximum SPL of 104dB. The Speaker shall have 60 Watts or more Dynamic Power (Lo Impedance). It shall have a Transformer tapping of 30,15,7.5 Watts &4/8 ohm or more.It shall have CE, FCC, RoHS, ISO9001, ISO27001, ISO50001 & ISO14001 Certifications, All certificates need to attached. Surface mount Speaker |
| 196 | Supply, Installation, Testing and Commissioning of 40' HDMI Active Optical Cable Type A to Type A. It shall support resolutions of up to 8k@60 Hz or better. It shall have a Power Consumption of 250mV or better. It shall have a dynamic bend radius of 40mm or better. It shall have a static bend radius of 20mm or better. It shall support eARC & CEC. It shall be HDMI 2.1 or better. It shall support HDCP 2.2 or better. It shall have an outer diameter of 4.4mm or less. It shall be highly resistant with RF and EMI interference. It shall work without the use of External Power Supplies.It shall have CE, FCC, RoHS, ISO9001, ISO27001, ISO50001 & ISO14001 Certifications, All certificates need to attached. 40' Active Optical HDMI 2.1 Cable |
| 197 | Supply, Installation, Testing and Commissioning of 17U AV Equipment Rack. It shall be supplied with 4x 6 Port 6A Power Surge protector. It shall have 3x mounting plates. Complete mounting screws. It shall have Front glass door with wheels complete in all respect. It shall be supplied with Cable Manager as per requirement.Equipment rack |
| 198 | Supply, Installation, Testing and Commissioning of 2 Core 10 AWG Speaker cable (in meters).as per speciafication and approved by EIC/RSP-SAIL, complete in all respect.Speaker Cable |
| 199 | Supply, Installation, Testing and Commissioning of Connectors and Patch Cors to Complete the interconnections and make the site up and ready (in lot). Connectors and Patch Cords |
| 200 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) . (Approved Makes: Daikin/Toshiba/General/Mistribushi/Voltas) |
| 201 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in 1S: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge,upto 90 metre depth below ground level. 300 MM Dia |
| 202 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in 1S: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 MM Dia |
| 203 | Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges,fittings & accessories etc. all complete, for all depths, as per direction ofEngineer -in-charge.150 MM Nominal size dia |
| 204 | Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc. allcomplete, for all depths, as per direction of Engineer-in-charge. |
| 205 | Development of tube well in accordance with 1S : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories efc., all as per requirement and direction of Engineer-in-charge. |
| 206 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia |
| 207 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp |
| 208 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per 1S:2800 (part I). |
| 209 | Supply of 2 HP KSB make submersible pump set model BPD 302/4+6UMA1/G 150/6/22 (SD) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with KSB electric motor operating of 415 volts suitable for 3 phase 50 cycle A.C. Supply of following duty condition 2 HP 2 stage pipe. A-Discharge of water in LPM 860 Approx size of discharge outlet in 40mm.B-Total Head of pump set 45M |
| 210 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber ins ertions etc. (the tail pieces if required will be paid separately) 100 mm diameter Class | |
| 211 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Wire 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 212 | supply installation testing and commissioning work manual call boxes of MS construction in surface/ recess with stainless steel chain and hammer assembly complete with glass and pushed button etc as required |
| 213 | Supplying installation testing and commissioning fire alarm sounder with facility to make announcement mounted in ms box 16 swg with hinged cover plate and suitable for operation with amplifier IC line magic transformer etc complete as required |
| 214 | supplying and laying 25MM Dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc is required |
| 215 | Supplying installation testing and commissioning sector panel suitable for following zones complete with visual indications for short circuit fault open circuit fault fire condition and all other standard facilities as per IS: 2189 with mimic diagram for all areas own cover complete with all connections interconnections as required |
| 216 | Supplying installation testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following complete in all respects as required terrorist pump A)Horizontal pipe multistage centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft mechanical seal confirming to IS 1520 B) suitable hv squirrel cage intuition motor tfc type sin owners 1500 rpmc table for operation on 415 volts 3phase 50 Hz AC supply with IP 55 production for enclosure horizontal foot mounted type with glass F insulation confirming toIS- 325 C) MS fabricated common base plate coupling guard foundation holds etc as required d) suitable cement concrete foundation duly plastered with anti vibration pads 900 IPM at 35M HEAD |
| 217 | Providing laying testing and commissioning of B class heavy duty MS pipe confirming to is 1239 including welding fittings like elbows tea flinges peppers tuples gaskets etc and fixing the pipe on the wall ceiling with suitable clamp support frame and painting with two or more ports of synthetic enamel paint of required shear to complete 100MM dia |
| 218 | Providing installation testing and commission of non return wall of following sizes confirming to IS 5312 complete with rubber gaskets GI bolts nuts washers etc as required 100MM DIA |
| 219 | Supplying and fixing 63mm dia 15M long RRL hose pipe with 63MM Dia male and female couplings duly bound with GI wire riots at sector confirming two IS 636 type A as required Gunmetal |
| 220 | Supplying and fixing first aid hose reel with MS construction spray painted to in post office red confirming to IS 884 compete with the following as required 20MM nominal internal dia water boost thermoplastic textile reinforced type 2S per IS 12585 20MM nominal integral diacon metal globe wall and nozzle Drum and brackets for fixing the equipments on wall connetions from riser with 25MM dia stop gun metal wall and ms pipe and socket 30 M |
| 221 | Providing and fixing of pressure switch in MS pipeline including connexion etc as required |
| 222 | Excavating trenches in all kinds of soil of required with for pipe cables etc including excavation for sockets and dressing of sites ramming of bottoms depth up to 1.5 M including getting out the excavated soil and then returning this soil as required In layers not exceeding 20 centimetre in depth including consolidating each deposited layer by ramming watering etc and disposing of surplus excavated soil as directed within a lead of 50m Five's 80MM to 300MM diameter |
| 223 | Constructing machinery chamber 60X60X75CM inside with 75 class designation brickwork in cement motor 1:5(1 cement: 5 finne cement) for fire hydrants with ci surface box 350X350 mm top and 165MM deep inside with chain lid and rcc top slab 1:2:4 mix 1cement to:2coarse sand:4 graded stone aggregate 20MM nominal size necessary excavation foundation concrete 1:5:10 (1 cement:5fine sand:5 graded stone) aggregate 40 mm nominal size and inside plastering with cement to motor 1:3 (1cement: 3coarse sand )and 12 mm thick finished with a floating coat of neat cement complete as per standard design |
| 224 | Providing and placing on terrace at all floor levels polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangementand making necessary goals for inlet outlet handover through pipes but without fittings and the base support for tank Capacity 5000 litre |
| 225 | Supply and fixing of fire extinguisher abc type 6.00 kg capacity isi marked is 15683 and tse approved complete with initial charge and wall bracket along with supply of all materials and labour for proper completion of work |
| 226 | supply and fixing of Co2 tight fire extinguisher 6.5 kg capacity isi marked is 2878 and tse approved complete with initial charge and hold bracket along with supply of all materials and labour for complete proper completion of work |
| 227 | Providing fixing of fire hose cabinet box made out of a teenage ms sheet including two quarts of post office red paint over one quart of primer with four mm thick glass door in front painted fire in red luminous paint Ied the size of the box should be 750MM X 600MM X 250MM size capable of accommodated a pair of hose with couplings and nozzle the box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete make the standard make |
| 228 | Providing fixing of cubicle type floor mounted fire pump control panel fabricated from 16 GMS sheet duly powder coated finish of approved shade and comprising of A40 AMP 3 poll Mccb 50 HZ with breaking capacity 10KW B-1 volt metre 500V with selector switch C1 set including lamps Make RQ Book Fire Protection Services Pvt Ltd RK Engineers Services c certified iso 134852016 and Ohio 1800 12007 approved |
| 229 | Supply , Installation , Testing and commissioning of CAT 6 UTP cable |
| 230 | Supply, Installation, Testing & Commissioning of CAT 6 UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 1 Mtr for rack side switch to jack panel connectivity. |
| 231 | SITC Of 12 U wall Mountable open Rack with front glass door and rear ms door including with 3 socket 6/16 Amp PDU, mounting hardware & Fan Tray. |
| 232 | Supply, Installation, Testing & Commissioning of 12 floor mount rack with fans, 2 cable managers stationary shelf, 2 Nos. of hardware pkts |
| 233 | Supply, installation, testing and commissioning of2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens |
| 234 | Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having following specifications and features etc :-2MP @ 25/30fps@1080P (1920×1080) Outdoor Bullet Camera with 2.8/ 3.6mm fixed lens |
| 235 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support 3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot. 6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232 7) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0) 8) Video Output Ports: 1x HDMI and 1 VGA 9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 236 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 8TB |
| 237 | Supply, Installation, Testing and Commissioning of Full HD 55\\" LED Professional Display Panel. Approved Makes: Panasonic / LG/ Sony/ Samsung |
| 238 | Supply, Installation, Testing & Commissioning of L2 managed industrial PoE switch with 24 10/100/1000M RJ45 ports |
| 239 | Removing white or colour wash by scrapping and sand papering and reparing the surface smooth including necessary repairs to scratches etc. complete |
| 240 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 241 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 242 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge All kinds of soil. |
| 243 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 244 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete prepared with batch mixing machine |
| 245 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound. |
| 246 | Supply and Laying for separation membrane of impermeable plastic sheeting 125 micron thick. |
| 247 | 20 mm cement plaster of mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement |
| 248 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 249 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. |
| 250 | Providing and fixing of UPVC SWR ring fit pipe of class B of ISI mark Confirming to IS code 13592 (make prince, supreme finolex) in internal works of toilet and RWP etc. including fixing with rubber rings etc. including cost of all material, labour etc. complete.. b) 160mm diameter |
| 251 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : (For pipes 100 to 250 mm diameter) |
| 252 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in-Charge. External work. |
| 253 | 32mm nominal bore. |
| 254 | 40mm nominal bore. |
| 255 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 32mm |
| 256 | Constructing masonry Chamber brick work with common burnt clay F.P.S.(non modular) bricks of class designation 150 in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar :3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. 60x60x75 cm inside |
| 257 | Provding and fixing gun metal non return valve of approved quality (screwed end) 80 mm nominal bore a) Horizontal |
| 258 | Laying of one no. of PVC insulated and PVC seathead XL PE Power cable 1.1 kv grade of following size direct in ground including excavation sand cuhshioning and protective covering and refilling the trench etc as required . |
| 259 | 150 sqmm 3.5 core |
| 260 | 95 sqmm 3.5 core |
| 261 | 50 sqmm 3.5 core |
| 262 | 25 sqmm 3.5 core |
| 263 | Supply and fixing with end termination of brass nickle plated compression gland and alluminium lugs for following size of PVC insulated and armoured served sheathed, alluminium conductor cable of 1.1 kv grade as required . |
| 264 | 150 sqmm 3.5 core |
| 265 | 95 sqmm 3.5 core |
| 266 | 50 sqmm 3.5 core |
| 267 | 25 sqmm 3.5 core |
| 268 | Earthing with GI of earth plate 600x 600x 6.0mm G.I. plate,including assesories and providing masonry enclosure with cover plate having locking arrengement vestically for earthing with its top at least 2.7 meters below ground level complete with layers of charcoal/coke and salt at leat 150mm thick alround etc. |
| 269 | Supplying & Laying of 25mmx5mm G.I. Strip for earthing purpose as required complete in all respects. |
| 270 | Supply & fixing of two number 6 SWG G.I. wire for earthing purpose as required complete in all respects. |
| 271 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 272 | S/F of 400 Amp capacity TP&N DISCONNECTOR FUSE switch unit inside the existing panal board with ISI marked HRC fuse including drilling holes in cubicle panel making connection complete with HRC fuse etc.on angle iron frame complete in all respects. |
| 273 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 274 | Supply and erection of steel tubular pole 7.5 meters long designated 410 SP-6 in 1:3:6 cement concrete foundation including excavation, back filling etc. complete in all respects. |
| 275 | Supply and Fixing of service bracket of 50mm. Dia 4 meter long fabricated from class ''B'' G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete in all respects. |
| 276 | Supply and fixing of LED street light fitting having diecast aluminium body and diffuser/reflector with driver set suitable for 75 watt to 90 Watt confirming to IP 65 protection complete in all respect.CAT AAA |
| 277 | S/F of 32A 240 V DP metal clad rewireable type switch fuse unit on M.D.F.E.G. board complete in all respects. |
| 278 | Painting of the pole with 2 coats of aluminium paint over red oxide primer complete in all respects. |
| 279 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect. |
| 280 | Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including getting out & disposal of excavated earth upto 1.5m as directed by Engineer in charge All kind of soil. In all kind of soil upto 1.5m to 3.0m. depth |
| 281 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 282 | Providing & fixing 75mm dia vent pipes. |
| 283 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 284 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. L.D. -2.5- Circular shape 450mm internal diameter |
| 285 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks |
| 286 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 3.0m to 4.5m. depth |
| 287 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tnsile steel bars. |
| 288 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 289 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 290 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 291 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 292 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 293 | Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light traffic parkingetc, of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over 50 mmthick compacted bed of sand, compacting and proper embedding/layingof inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cuttingof paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approvedcolour design and pattern |
| 294 | High Back Chair, PP Chrome Cushion Arm, Torsion Bar, Gas Lift, PP Chrome Base |
| 295 | Executive Table, Particle Board Top, One Side Post Forming, One Hanging DrawerW1200 X D600 X H750 |
| 296 | Medium Back Chair, Chrome Cushion Arm, Swivel Tilt, Gas Lift, Chrome Base |
| 297 | Conference Table, Particle Board Edge Banded Top W3000 X D1200 X H750 |
| 298 | Workstation Table, Panel Based Partition, Particle Board Edge Banded Top W4000 X D1260 X H1200 |
| 299 | Student Chair, PP Seat Back Shell, PLPB Writing Pad, Book Shelf |
| 300 | Dual Desk, Injection Moulded PP Edge Banding PLPB Top & Seat Back, Powder Coated Pipe Frame & Sheet Shelf Top Size - 1100 X 400 X 18mm Thick Overall Size - 1100 X 950 X 750 |
| 301 | Steel Almirah, 2 Doors, 4 Adjustable Shelf, Thickness 0.8mm W915 X D485 X H1980 |
| 302 | Supply of 16M High Mast System with its accessories. Mast shaft shall be hot dip galvanised (single dip) and suitable for wind velocity as per IS 875 part 3. It shall also include accessories for high mast including head frame, steel wire rope 5mm dia, trailing cable, single drum winch, galvanized lantern carriage arrangement suitable for 4 luminaires symmetrically. The mast shall have provision for mounting integral power tool at the base compartment for its operation.16 M High Mast System |
| 303 | Fixing of Pole in foundation with bolts manufactured from special steel along with nuts, washers, anchor plates & templates. |
| 304 | LED type with 6 nos x 180 W LED its control gear boxes. |
| 305 | Supply of twin dome aviation obstruction lights of type BJAOL with 100W GLS lamp. |
| 306 | Control panel ousing suitable control curcuit for automatic switching ON and OFF of the mast. It shall also have suitable controls for operation of Power Tool Erection, testing & commissioning.. |
| 307 | Construction of suitable shallow foundation with 'M20' grade concrete for the high mast considering the safe SBC at site as 10 T/sqmtr at 2 mt depth with all materials & labour. |
| 308 | Erection of the high mast with the help of suitable equipments and wiring of luminaires with all wiring material & labour. |
| 309 | Provision of GI pipe earthing for High Mast with 2.5M long 40mm dia G.I. Pipe including connection of High mast earth terminal with 25 x 3mm GI flats with all materials & labour. |
| 310 | Installation of control panel on suitable foundation including all material & labour |
| 311 | Supplying, drawing, connecting and testing of following size of PVC insulated FRLS copper conductor (as per IS : 694) flexible multicore wire in the existing high mast from control panel to the fitting i/c providing suitable copper lugs connections etc. as reqd. 3 x 6 sq.mm |
| 312 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 313 | Supplying and stacking of good earth at site including royalty but including carriage 1km (earth measusred in stacks will be reduced by 20% for payment). |
| 314 | Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm |
| 315 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. |
| 316 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 317 | Rough dressing the trenched ground including breaking the clods as per direction of E/I.. |
| 318 | Fine dressing the ground as per direction of E/I.. |
| 319 | Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). |
| 320 | Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. |
| 321 | Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge |
| 322 | Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 323 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep |
| 324 | Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). |
| 325 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) |
| 326 | Providing and displaying of Croton Baby Golden Punctatum Aureum having ht. 23 cm to 30 cm, well developed with fresh and healthy foliage in 15 cm size of Earthen pot/Plastic pot. as per direction of the officer-in-charge. |
| 327 | Providing and displaying of Croton Golden specimen having ht. 90 cm to 1.05 cm with 5 to 6 branches, well developed, fresh and healthy foliage in 30 cm size of Earthen pot/Plastic pot as per direction of the officer-in-charge. |
| 328 | Providing and Displaying Marigold jaffri orange/ yellow/ Russet colour well developed with fresh & healthy foliage with 40 to 50 flowers in bloom specimen plant 60 to 75 cm ht in 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 329 | Providing and Displaying Poinsettia dwarf multi head, having upto 30 cm ht., with 3 to 4 branches with fully different colored top with fresh & healthy foliage well developed in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 330 | Providing and Displaying Caladium Hybrid variety 3 to 4 in a pot well developed with fresh & healthy foliage 30 to 45 cm ht. in different colour 25 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 331 | Providing and Displaying Portulaca hybrid in different colour with bloom well developed fresh & healthy in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge. |
| 332 | Providing and stacking of Nerium oleander (kaner) dwarf of height 30-40 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge. |
| 333 | Providing and stacking of Tabernaemontana divaricata (Chandni double) of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 334 | Providing and displaying of Phoenix palm having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 335 | Providing and Displaying Fishtail palm well developed with fresh & healthy foliage leaves of ht 210 to 240cm Specimen in 35 cm Cement Pot as per direction of the officer-in-charge. |
| 336 | Providing and Displaying Foxtail palm well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge. |
| 337 | Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge |
| 338 | Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 339 | Providing and stacking of Inga dulcis (Jungle Jalebi) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 340 | Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysJul 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender