Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #56249035

Tender For Repair/ Maintenance Of Security Lights, Flood Lights And Connected Items At Sec-Ii Under The Aor Of Ge Devlali.

Issued by Statutory Bodies & Commissions/Committees · Nashik, Maharashtra
Tender Value
49 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
9 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Maintenance Of Security Lights, Flood Lights And Connected Items At Sec-Ii Under The Aor Of Ge Devlali.

BOQ

Name of Work:- REPAIR/ MAINTENANCE OF SECURITY LIGHTS, FLOOD LIGHTS AND CONNECTED ITEMS AT SEC-II UNDER THE AOR OF GE DEVLALI.
Sl. No. Item Description
1Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable ISI marked, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following sizes:-
24 core 10 sqmm
34 core 16 sqmm
42 core 10 sqmm
54 core 25 sqmm
63.5 core 35 sqmm
73.5 core 50 sqmm
83.5 core 70 sqmm
9Taking down existing defective LT under ground cable of any size from trenches complete all as directed
10Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and electric pole as per specification and getting out in soft/loose soil complete all as specified and directed.
11Supply & lay in trenches double walled corugated HDPE pipe 50 mm dia high density for protection of under ground cables( Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted)
12Supply & lay in trenches double walled corugated HDPE pipe 70 mm dia high density for protection of under ground cables( Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted)
13Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed
14Removing of excavted soil to a distance n. exc. 50 mtr from starting point and deposited where directed at a level not exceeding 1.5 mtr above the starting point including spreadind complete all as specified and directed.
15Taking down defective street light fittings of any type and any wattage. for Inspection / checking /finding faults /repairs/replacement of parts, including thorough cleaning of acrylic perpex cover and refixing the same in existing position after carrying out necessary repair/replacement of parts, complete including testing etc for smooth functioning all as specified and directed. Note :- (i) Repair/replacement of parts( after taking down fitting) required will be measured and paid separately in relevent items of schedule as supply and fix .
16Supply & fixing in replacement Driver for 120 Watt LED street light fitting of Model No Endura City Liner Neo, Make Havells
17Supply & fixing in replacement Driver for upto 72 Watt LED street light fitting of Make Havells/Bajaj/ Crompton
18S&F supply and fix in repair PVC insulated stranded unaroured Copper conductor cable 1.0 Sqmm flat/ round three core 1100 volts grade for street light complete all as specified and directed
19Taking down of High masts light and refixing it after replacing /repairing defective items all as specified and directed. NOTE:-ALL matertial will be paid seperately.
20Supply and lay in replacement 40 mm bore GI tubing light grade, ISI marked, for cable protection at road crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps,saddels etc complete all as specified and as directed.
21M & L for scrubbing out old paint,rust etc from 9 Mtr long pole and making smooth and even suface then painting with one coat of anti rust paint and two coats of superior quality aluminium paint on entire exposed portion of pole structure including all fitments on pole and writing pole number with 2'' size with white paint lettering on black base all as directed at site .(work shall be completed in the stipulated period as directed.
22S&F in replacement new Endura cityliner Neo 70 Watt LED Luminaries lense embaded PC cover with high power LED as light source of 70W with10 KV built in surg protector, IP 66 protection and impact resistance of IK07. (suitable for pole/bracket dia 54 mm) Make Havells Cat Part Num:-ENDURACITYLINERNEOSL70WLED 757PASYBOTG or Equivalent model in Wipro/ Philips/ Crompton.
23S&F in replacement new Endura cityliner Neo 60 Watt LED Luminaries lense embaded PC cover with high power LED as light source of 60W with10 KV built in surg protector, IP 66 protection and impact resistance of IK07. (suitable for pole/bracket dia 54 mm) Make Havells Cat Part Num:-ENDURACITYLINERNEOSL60WLED 757PASYBOTG or Equivalent model in Wipro/ Philips/ Crompton.
24S&F in replacement new Endura cityliner Neo 120 Watt LED Luminaries with high power LED as light source of 120W with10 KV built in surg protector, IP 66 protection and impact resistance of IK07.( suitable for pole/bracket dia 54 mm) Make Havells Cat Part Num:- ENDURAPEARLMAGSL120WLED 757PASYTOTGASTHO or Equivalent model in Wipro/ Philips/ Crompton.
25S&F in reolacement Energy saving, environment friendly & robust IP 65 protected 80 Watt LED midbay with PDC housing suitable for ceiling (Surface/Suspended) mount & in Wide beam optics. Make- Havells model - ILIOSBAYPLUSHBP80WLED857SP90DTOPC/ or equivalent of Wipro/ Philips/Compton.
26S & F in replacement Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, 200 Watt suitable for highlighting architectural facade and general purpose lighting. Make- Havells, Model - JETAVALOURFL200WLED757MODNBLTG or Equivalent of Wipro/ Bajaj/ Crompton
27Supply & fix in replacement Thermo plastic street light sintex box of size 280 X 170 X 130 mm Cat No GS-JB-2817 top Hinged ( or equivalent make of National) wiith 4 way connector mounted on epoxy insulators for looping of cable for 3 Phase and 1 neutral fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box.
28Supply & fix in replacement Thermo plastic street light sintex box of size 280 X 170 X 130 mm Cat No GS-JB-2817 top Hinged ( or equivalent make of National) wiith MCB TPN 32 Amps for looping of cable for 3 Phase and 1 neutral fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box.
29S &F in replacement Astronomical time switch model L&T GIC Astro Mini T2DDT7, 240 Volts DIN Mounting suitable for street light auto On-Off circuit Make L&T or equivalent of Siemens/ Legrand
30S &F in replacement 3 Phase 32 Amps contactor 415 Volts coil votage AC supply suitable for street light auto On-Off circuit Make L&T, Model - MNX-32 or eqivalent of Siemens/ Legrand
31S &F in replacement 3 Phase 50 Amps contactor 415 Volts coil votage AC supply suitable for street light auto On-Off circuit Make L&T, Model - MNX-50 or eqivalent of Siemens/ Legrand
32Supply and fix in replacement coil (CS94192) of voltage 415 coil voltage suitable for contactor MNX50/70/80 of make L&T
33Supply and fix in replacement MCB TPN 32 Amps, 240 volts complete all as specified and as directed.
34Supply and fix in replacement MCB TPN 63 Amps, 240 volts complete all as specified and as directed.
35Supply and fix , test , commissioning of LT weather proofFeeder pillar board powder coated out door type double door shutter type made out of CRCA 3.15 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron & depth of the panel should not be less than 45cm) a) Aluminium bus bar of capacity 600 Amps for Phase-R-Y-B & 150 Amps for neutral -1 No b) MCCB 4 Pole 50 KA , 400 Amp - 1 No (I/C Main)c) MCCB 4 Pole 36 KA , 250 Amp - 2 Nos (Out going )d) MCCB 4 Pole 25 KA, 160Amp - 4 Nos (Out going)
36Supply and fix , test , commissioning of LT weather proofFeeder pillar board powder coated out door type double door shutter type made out of CRCA 3.15 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron & depth of the panel should not be less than 45cm) a) Aluminium bus bar of capacity 600 Amps for Phase-R-Y-B & 150 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 250 Amp - 1 Nos (incoming )c) MCCB 4 Pole 25 KA, 160Amp - 5 Nos (Out going)
37Supply and fix , test , commissioning of LT weather proofFeeder pillar and Timer panel board powder coated out door type double door shutter type made out of CRCA 3.15 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron & depth of the panel should not be less than 45cm) a) Aluminium bus bar of capacity 300 Amps for Phase-R-Y-B & 150 Amps for neutral -1 No b) MCCB 4 Pole 25 KA , 200 Amp - 1 No (I/C Main)c) MCCB 4 Pole 25 KA , 125 Amp - 3 No (Out going )d) MCB TPN 63 Amp/40 Amp 10 KA - 1 Nos e) Astronomical timer suitable for street light control as per sunrise and sun set with 32 Amps MNX 32 contactor ( L&T) 3Ph, 415 Volt - 0 1 Set
38S &F in replacement Automatic street light switch using NATURE SWITCH for automatic switching of street Lights based on LUX level of Natural Light. The sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/ wall mountable enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54 degree of ingress. The contactor, MCB and Circuit wiring should suitable enough to take load of 12 KW equally distributed over 3 Phase (4KW /Phase). Model No- 02EC12KW3P, Contactor Rating : 40 Amps (AC3), MCB (single-pole) Rating :63 Amps 3 Nos. Make : Nature Switch : Kakatiya Energy Systems Pvt Ltd Hyderabad or Equivalent of Bajaj /L&T/Legrand
39Supply and fix in replacement MCCB 63 Amps 25 KA 4 Pole
40Taking down old us poles of any type & supply, install & errect in true vertical posision galvanised steel octagonal poles 7 meter long with side mounted decorative type single arm bracket for mounting street lights of 3 mm thick sheet , bottom dia 130 mm and top dia 70 mm finial tapered complete with MS base plate of size 200mmx200mmx12mm, foundation bolts, nuts, washers & screws.The poles shall be hot dip galvanized as per relevant Indian standards with average coating thickness of minimum 70 micron. the material of pole HT Steel Conforming to grade S355JO & that of base plate is Fe 410 conforming to IS 226 / IS 2062. The Octagonal Poles shall be in single section. There shall not be any circumferential weld joint. Pole drawing along with details of base plate , foundation bolts and foundation details (RCC) shall be submitted along with pole. (Note: excavation, RCC foundation as per manufacturer drawing & specification, foundation bolts with nut & washers, Decorative type single arm for mounting street light, connector block for 3phase+ 1nutral for cable termination & MCB SP 10 Ams & pole cap is deemed to be included in rate quoted)
41M&L earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
42All as item No 34 above but earthig using 25x4mm size GI strip.
43Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe/HDPE pipe for encasing of cable and repairing the road to match with the original finish complete all as specified.
44M&L for making underground boaring (Manually/Mech) through existing bituminous road/PCC/Floor along cross section approx 10 mtr of the road at a depth approx 1.0 mtr for laying of GI tubing of dia 80/100 mm for encasing of cable all as specified and directed at site.
45Supply and fix inside the optical fiber pole tricolour LED strip 18 meter long ( orange+ white+ green in single strip) with driver operating on 230 volt, 50 Hz AC supply all as specified and directed.( Note-taking downoptical fibre pole upto 8 meter long and refixing the same after installation of LED strip is deemed to be included in rate quoted) Make: Philips/Havells/bajaj/Wipro
46Note: Amount of sch of credit of Rs. 1,38,280.00will be deducted from total amount of BOQ. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56249035
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 22-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Maintenance Of Security Lights, Flood Lights And Connected Items At Sec-Ii Under The Aor Of Ge Devlali.
Basic Detail
Tender No 8220/E8
Bidding Type Tender
Location
City Nashik
State Maharashtra
Key Dates
Publish Date 01 Jul 2026
Submission Date 22 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
273104eb-a0b6-4831-af3c-e00c142fe283.html
BOQ_868627.xls
generalpages.pdf
ps.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

273104eb-a0b6-4831-af3c-e00c142fe283.html

xls

BOQ_868627.xls

pdf

generalpages.pdf

pdf

ps.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders