Tender For Supply, Installation, Testing & Commissioning Of Power Supply For Ductable Air Conditioning Work In The Shreenivas Deshpande Library, Iit(Bhu), Varanasi.
Tender Value
23.22 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
6 days left
EMD
46500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing & Commissioning Of Power Supply For Ductable Air Conditioning Work In The Shreenivas Deshpande Library, Iit(Bhu), Varanasi.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Make: Polycab/ Finolex/ L&T) |
| 2 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | 4 X 10sq. mm + 2 X 6 sq. mm earth wire |
| 5 | LED Panel light 2x2 ft., (System lumen efficacy>135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm). |
| 6 | 36Watt |
| 7 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 8 | 8 way (4 + 24), Double door |
| 9 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required |
| 10 | 8 way (4 + 24), Double door |
| 11 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Voltage 690V etc. as required. Icu and Operational |
| 12 | 125 A,36KA,FPMCCB |
| 13 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 14 | Single Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 15 | Double Pole MCB Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 16 | Treeple Pole MCB Make- |
| 17 | FP MCB 40/63 A Make-L&T/ABB/C&S/Legrand/Hagger/Seimens/Schneider |
| 18 | Supply, Installation ,testing & Commisionioning (SITC) of outdoor CPRI certified cubical Feeder pilar with EC grade Al busbar capacity 630Amp. 100% netural suitable >25ka for 3 sec for fault level, compatiable for following incomming & outgoing . Custum built self fabricated out of 16SWG , CRCA sheet Foot mounted type Panel Furnished with siemen gray shade powder coated paint after necessary pre treatment fully dust & vermin proof, Copper wire ,Lugs and Netural & Insulating Material Engineering and Labor Charges ,Panle size (H-W-D)mm. Details as Incoming-SFU400 Amp. 2 nos. & 6 nos-HRC fuse, with Changeover 400 Amp. Incomer All Busbar capacity 500 Amp. Phase indicating light shall be protected by 6 amps MCB‟s. - 3 Sets, AVF Meter - 01 No Outgoing -Deatils TP MCCB-200 Amp.2 Nos, TP MCCB-125 4 nos. . (Range 40A -630A , Protaction against overload, and short and 63Amp MCB-6 nos. circuit) , 0-24 hours Astronomical timer auto / manual by pass selector switches Cubicle Type 1 nos. Note-MCCB Make- Legrand/L& K/Simens/Schneider, 7 Nos. 203432.00 1424024.00, 5 Supplying and making end termination with brass compress |
| 19 | Supply and laying of 3.5CX 185 sq.mm Armoured Aluminium cable 650/1100V grade as per IS 7098(Part 1) 2011, PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, Protective covering and refilling the trench etc as required. Make: KEI/Gloster/Universal/Polycab |
| 20 | 3.5CX 185 sq.mm |
| 21 | 3.5CX 150 sq.mm |
| 22 | 3.5CX 70 sq.mm |
| 23 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 24 | 3½ X 185 sq. mm (57mm) |
| 25 | 3½ X 150 sq. mm (57mm) |
| 26 | 11.1.24 3½ X 95 sq. mm (45mm) |
| 27 | 11.1.22 3½ X 50 sq. mm (35mm) |
| 28 | Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins,reinstalling the same as required |
| 29 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 30 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 31 | 4 X 10 sq. mm (25mm) |
| 32 | Supplying and fixing of 230VAC 1Ph. 300 mm exhaust Fan with sweep feature. Make: Usha / Crompton / Orient |
| 33 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, Installation, Testing & Commissioning of Flood Light, with chain 2.5 to 3 mtr and powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above |
| 34 | 70Watt |
| 35 | LED Batten/parking inside light light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours 47 DELHI SCHEDULE OF RATES (E&M)-2025 with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded alum |
| 36 | 36watt |
| 37 | Making of RCC foundation of dimesion size- 400 mm x 400 mm x 1200mm) with Gr M20 RCC and Fe 415 grade reinforcement for mounting of street line pole. |
| 38 | Supplying and laying of 1.1KV grade 4 core × 10sqmm one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make: KEI/ Gloster/ Universal/Polycab |
| 39 | Supplying and laying of 1.1KV grade 4 core × 25sqmm one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Make: KEI/ Gloster/ Universal/Polycab |
| 40 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 41 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 42 | SITC of decorative pole shall be made out of Mild Steel tube as per attached drawing. Total height of the pole shall be 3000mm nominal above the ground.The complete pole shall be of 100mm dia x 3.0mm thickness x 3000 mm long. The base plate shall be of dimension dia 250mm and thickness 10mm and joined with the pole by welding joint with the help of stiffeners. A built in service window shall be provided to accommodate a 6 amp SP MCB and 32 amp heavy duty connector for mains connections in the bottom part of the pole as shown in the attached drawing. The decorative pole shall be machined and polished properly to give it a smooth surface. The decorative pole shall be duly pretreated by shot blasting process and coated with high end epoxy primers and top coat in UV ray resistant polyurethane/Polyester coating in approved colour shade. The Coating on the pole shall be baked in oven at required temperature and parameters. The DFT of coating on pole shall be 90 microns (minimum). The coating on pole and bracket shall pass minimum 300 salt spray hours. Wind pressure calculation shall be done as per IS875 for wind speed of 180 km/hr. The contractor has to specify pole manufacturers name and manufacturing facility details in technical bid. The pole manufacturer shall have inhouse facility for pole fabrication consisting of Laser cutting machine, Pole fabrication and Mig welding plant, shot blasting machine, Oven to bake required pole and bracket. The EIC will visit the plant to ascertain the required plant and machinery at manufacturers facility. Make-Homedec Lighting Item Cat No- HL-MSP-241 (3000 MM)/TWINKLE Luminaries CAT No-3 mtr. Luxmax VICTORIA Steel-N (Cast Iron) Pole /Crompton/Philps/Wipro equivalent to specified make SITC of decorative Led Post Top Light shall be made of cast spun & extruded aluminum and shall have Ingress protection of IP66 for optical compartment and Impact Resistance of IK 06 or more. The effective Width & Height of the Led Post Top Light shall be dia 600mm x 440mm respectively. The Led Post Top Light shall be in 60w LED. Translucent Polycarbonate Diffuser shall be fitted in the Led Post Top Light. Integrated suitable BIS approved LED Driver shall be fitted inside the Led. Post Top Light having efficiency >85%, power factor shall be>0.95, THD<=10%, with driver standard voltage withstand range of 100-300V AC and inbuilt surge protection of min 4KV. The Luminaire shall have external surge protection device of 10KV. Led shall be Osram/Seoul/Cree/Bridgelux or equivalent reputed make and shall have luminous efficacy of more than 140 Lm/Watt. System luminous efficacy shall be more than 90 Lm/Watt. The CCT of Led shall be 3000/4000/6000K as required by engineer in charge. The shape and sizes of the Led Post Top Light shall be as per attached drawing. System life of 50,000 burning hours with 70% of initial lumens maintained. The Led Post Top Light shall be machined and polished properly to give it a smooth surface and shall be coated in UV ray resistant Polyurethane/ Polyester coating in approved colour shade. The Coating on the Led Post Top Light shall be baked in oven at required temperature and parameters. The contractor has to specify pole/Luminaire manufacturers name and manufacturing facility details in technical bid. The pole manufacturer shall have in house testing facility for Post Top light luminaire viz- LM-79, IP-65, IK-06. Oven to bake coating required luminaire. The EIC will visit the plant to ascertain the required testing equipments, plant and machinery. Following third party test reports will be required with the material. LM-79,IP-65,IK-06,LM-80 FOR LED,BIS OF DRIVER,BIS OF POST TOP LIGHT Make- Homedec Cat No-HL-2397 (60W led)/LuxMax-PT-232-HZ-P (60W) /Crompton/Philps/Wipro equivalent to specified make |
| 43 | Supply & Installation of LED Bollard 12-15W± 10% , Integral type bollard cylindrical/Conical Shape, Die cast aluminium Housing , Dome shape , Top cover fixed with , Cylindrical/ Conical Shape acrylic cover Opal White Poly Carbonate Diffuser.SMD LED of 1 to 3 Watt each assembled on single MCPCB, Led Lamp lumens output with efficacy >80 lm/W, Rated Current < 0.050 A, Lumen Output > 800 Lm, Approx Weight < 2.0Kg , Driver PF> 0.95 Luminaire having color temp up to 6500K & 50,000 Burning Hours. life with minimum @ L 70, The color rendering index of LED light should be more than 70. Luminiare, Conical Surface flux @ 120 Degree is > 80 L/w, comprises of driver PF >0.95 & Surge Protection 3KV , IP65 Protection , Submission with Technical Data Sheet , LM80 Report, Warranty letter from Manufacturers, Connection Wire, Testing etc. to complete the job having base plate with holes for direct mounting. Bollard LED 10 Watt cylindrical shape height > 600mm, Color Temp 3000-6000k ±10%, Product Dimension Minimum - L- 600mm, D- 140mm (± 10%) equlent of modules Miram Bollard OBL-GRYLBD OR equivalent /jaquar. MAKE:-Phillipse/Wipro//CG |
| 44 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 45 | 3 output (1output per phase) and suitable for three phase supply Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysJul 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender