Tender For Improvement To Certain Installation Like Foundation, Suction And Delivery Line, Football, Nrv, Plain Cement Concrete Path, Interlocking Tile And Certain Other Allied Works At Af Stn Bhuj
Tender Overview
Project Description
Tender for Improvement To Certain Installation Like Foundation, Suction And Delivery Line, Football, Nrv, Plain Cement Concrete Path, Interlocking Tile And Certain Other Allied Works At Af Stn Bhuj
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-Jul-2026 | Corrigendum | Terms and Conditions | 20-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in soft soil for pipe trenches all as specified and as directed. ( Note - Trenches shall be excavated for water supply pipe lines all as detailed under MES Schedule Part-I clause 18.42 to 18.42.6). |
| 2 | Excavating in dense not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in hard soil for pipe trenches all as specified and as directed. ( Note - Trenches shall be excavated for water supply pipe lines all as detailed under MES Schedule Part-I clause 18.42 to 18.42.6). |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of soils all as specified and as directed by EIC. |
| 4 | Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points all as specified and as directed by EIC. |
| 5 | Taking up/down existing old DI/GI tubing alongwith fixed connections and fittings from walls and ceilings trenches,under floor or road and to reuse of servicable portion if any complete all as specified and directed of following sizes : - |
| 6 | 100 mm bore |
| 7 | 80 mm bore |
| 8 | 50 mm bore |
| 9 | 40 mm bore |
| 10 | 25 mm bore |
| 11 | 20 mm bore |
| 12 | 15 mm bore |
| 13 | Relaying only GI tubing medium garde in trenches/wall/ceiling obtained from item No 5 here-in-before after cleaning or rerunning the old screw threads with replacement of unserviceable fittings and fixtures for following size of complete as directed. Note (i) Cost of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc., as required at site on walls, ceilings and in floors necessary to make connection operational and functional will be paid under this item and nothing extra will be paid on this account. |
| 14 | 100 mm bore |
| 15 | 80mm bore |
| 16 | 50 mm bore |
| 17 | 40 mm bore |
| 18 | 25 mm bore |
| 19 | 20 mm bore |
| 20 | 15 mm bore |
| 21 | M&L for galvanised steel tubes\\"medium grade\\" (ISI marked) with all fitting(ISI marked) and fixed complete to walls and ceilings or laid in floor/trenches and under road complete all as specified and directed of the following size:-Note (i) Cost of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc., as required at site on walls, ceilings and in floors necessary to make connection operational and functional will be paid under this item and nothing extra will be paid on this account. |
| 22 | 100 mm bore |
| 23 | 80mm bore |
| 24 | 50 mm bore |
| 25 | 40 mm bore |
| 26 | 25 mm bore |
| 27 | 20 mm bore |
| 28 | 15 mm bore |
| 29 | Taking up/down existing old UPVC/CPVC tubing alongwith fixed connections and fittings from walls and ceilings trenches,under floor or road and to reuse of servicable portion if any complete all as specified and directed of following sizes : - |
| 30 | 100 mm bore |
| 31 | 75 mm bore |
| 32 | 50 mm bore |
| 33 | 40 mm bore |
| 34 | 25 mm bore |
| 35 | 20 mm bore |
| 36 | 15 mm bore |
| 37 | Relaying only UPVC/CPVC in trenches/wall/ceiling obtained from item No 8 here-in-before after cleaning or rerunning the old screw threads with replacement of unserviceable fittings and fixtures for following size of complete as directed.Note (i) Cost of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc., as required at site on walls, ceilings and in floors necessary to make connection operational and functional will be paid under this item and nothing extra will be paid on this account. |
| 38 | 100 mm bore |
| 39 | 75 mm bore |
| 40 | 50 mm bore |
| 41 | 40 mm bore |
| 42 | 25 mm bore |
| 43 | 20 mm bore |
| 44 | 15 mm bore |
| 45 | Supply and laying UPVC pipes pressure rating 10 kgf/cm2 (SCH-80)with all fittings and fixtures laid in trenches,fixed complete to walls with GI clamps and ceiling or laid in floor of following size:-Note (i) Cost of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc., as required at site on walls, ceilings and in floors necessary to make connection operational and functional will be paid under this item and nothing extra will be paid on this account. |
| 46 | 100 mm bore |
| 47 | 75 mm bore |
| 48 | 50 mm bore |
| 49 | 40 mm bore |
| 50 | 25 mm bore |
| 51 | 20 mm bore |
| 52 | 15 mm bore |
| 53 | Supply and laying CPVC pipes of pressure rating 10Kg/sqcm class 2 (SDR 13.5) with fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc., as required at site on walls, ceilings and in floors of following size:-Note (i) Cost of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc., as required at site on walls, ceilings and in floors necessary to make connection operational and functional will be paid under this item and nothing extra will be paid on this account. |
| 54 | 25 mm bore |
| 55 | 20 mm bore Please Enable Macros to View BoQ information |
| 56 | 20 mm bore Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender