Drinking Water Supply and Sanitation Government Departments Closing in 11 days TDR #56245526

Tender For Renovation Work Of Pt. Shiv Kumar Shastri New Hostel In S Urnanand Sanskrit University At Varanasi

Issued by Government Departments · Varanasi, Uttar Pradesh
Tender Value
4.94 Crore
Estimated cost
Bid Submission
13 Jul 2026
11 days left
EMD
9.90 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Work Of Pt. Shiv Kumar Shastri New Hostel In S Urnanand Sanskrit University At Varanasi

BOQ

Name of Work:- Renovation work of Pt. Shiv Kumar Shastri New Hostel in S urnanand Sanskrit University at Varanasi
Sl. No. Item Description
1Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
2Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge
3Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead :Thickness up to 40 mm
4Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in Charge.
5Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
6For thickness of tiles 10 mm to 25 mm
7Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
8Providing and laying vitrified floor tiles of approve make and Brand in diffrence size (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
925mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete with base of cement mortar for 10 Sqm.
1025mm thick Kota stone slab in riser of steps, skirting 1:3 (1 cement 4 coarse sand) and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete with base of cement mortar for 10 Sqm.
11Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by approved make & colours), of 1st quality conforming to IS : 15622, of approved make, in colours & shade, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
12Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
13Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
14Providing and fixing bright /matt finished Stainless Steel Sliding Door Bolt of approved quality & make with necessary screws etc all complete. 250x16 mm.
15Providing and fixing bright /matt finished Stainless Steel Tower Bolt of approved quality & make with necessary screws etc all complete.
16250x10 mm.
17Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete
18Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm.
19Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete.
20Size 40 mm
21Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
22Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
23Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
2435 mm thick including ISI marked Stainless Steel butt hinges with necessary screws single leaves shutters
25Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
2625 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws
27Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
28Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage ofwater etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
29Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
30Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 98x40 mm & sash 30 x 55 mm with zinc alloy (zamak) powder coated handle with multi-locking system. (Height upto 1.8m)
31Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood30 mm thick
32Providing & fixing fly proof wire gauze to windows, clerestory windows &doors with M.S. Flat 15x3 mm and nuts & bolts complete.
33Stainless steel (grade 304) wire gauze of 0.5 mm dia wireand 1.4 mm aperture on both sides
34Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
35Of area beyond 3 sq. metres
3612 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
3715 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand)
38Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
39Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete.
40Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
41Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) (Apex Ultima, Weather coat All guard) Asian/ Berger.
42Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
43Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
44Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
45(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
46With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
47Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
48Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
49Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
50Providing and fixing soil, waste and vent pipes. Sand cast iron S&S pipe as per IS: 1729
51Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :
52Providing lead caulked joints to sand cast iron rain water pipes and fittings : 100 mm dia Pipe
53Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 1729
54Providing and fixing heel rest sanitary bend Sand cast iron S&S as per IS - 1729
55Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
56COST OF C.C. ROAD
57COST OF TESILE STRUCTURE
58Applying of Gunite in ratio 1:4 to an average thickness of 50-55 mm and excluding Mild Sreel or Iron work in Reinforcement Concrete.
59Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenchesor drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock
60Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
61Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
62Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
63Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
64Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). PLINTH BEAM
65Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). LINTEL
66Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). SLAB
67Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). SLAB BEAM
68Centering and shuttering including strutting, propping etc. and removal of form for :
69Foundations, footings, bases of columns, etc. for mass concrete
70Suspended floors, roofs, landings, balconies and access platform
71Lintels, beams, plinth beams, girders, bressumers and cantilevers
72Weather shade, Chajjas, corbels etc., including edges
73Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
74Brick Work with common burnt clay ( non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand)
75Brick Work with common burnt clay ( non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 ( 1 cement : 4 coarse sand)
76Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size)
77Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
78Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- Anti-Termite Treatment of the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
79Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
80Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete size 250x16 mm
81Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
82250x10 mm
83150x10 mm
84Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm
85Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
8635 mm thick single leaf shutters
87Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
88Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
89Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
90Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes
91Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
92Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
93(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
94(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
9512 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
9615 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand)
9715 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. In plinth.
98Add for plaster groove in plastered surface or moulding to R.C.C. projections.
99Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials, labour T & P etc for proper completion of the work.
10025 mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of size 20 mm and below) by laid over base concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips.
101Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
102Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
103Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
104Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
105Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
106Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
107110 mm diameter
108Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
109Coupler
110110 mm
111110 mm bend
112110 mm Shoe
113Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
114110 mm
115Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
116Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
117White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
118Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
119Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.
120White Vitreous China Wash basin size 630x450 mmwith a single 15 mm C.P. brass pillar tap
121Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
12232 mm dia
123Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
124Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required.
125Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
126Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and Single half urinal basins with 5 litre white P.V.C. automatic flushing cistern.
127Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.
128Granite Stone of approved shade
129Providing and fixing unplasticised PVC connection pipe with brass unions.
13015 mm nominal bore
131Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge.
132Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
133a) 15 mm nominal bore
134Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. ( for sink)
135a) 15 mm nominal bore
136Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931
137a) 15 mm nominal bore
138Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:
13915mm nominal bore
140Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
141Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
142Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
143450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
144Providing & fixing soil, waste and vent pipes.
145Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
146a) 100mm dia centrifugally cast iron S & S pipe.
147b) 75mm dia centrifugally cast iron S & S pipe.
148Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. ( for wash basin waste )
14932mm dia nominal bore
150SS 304 grade coupling with EPDM rubber gasket
151b)75mm
152SS 304 grade coupling with EPDM rubber gasket
153Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal
154size). Including cost of cutting holes & making good the walls etc.
155a) for 100mm dia pipe.
156b) for 75mm dia pipe.
157Providing & fixing cast iron coller.
158a) 100mm dia.
159b) 75mm dia.
160Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
161a) 100mm inlet & 100mm outlet.
162a) 100mm inlet & 75mm outlet.
163Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.
164a) 100mm
165b) 75mm
166Providing and fixing plain bend of required degree.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
167a) 100mm
168b) 75mm
169Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
170100x100x100mm
17175x75x75mm
172Providing and fixing centrifugaly cast iron single equal plain junction of required degree.
173100x100x100mm
17475x75x75mm
175Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :
176100x100x75mm
177Providing and fixing single unequal plain invert branch of required degree :
178100x100x75mm
179Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.)
180a) 100mm
181b) 75mm
182Providing and fixing cast iron terminal guard.
183100 mm
18475 mm
185Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
186Concealed work including cutting chases and making good the walls etc.
18715mm dia nominal outer dia pipes
18820mm dia nominal outer dia pipes
18925mm dia nominal outer dia pipes
190Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
191Internal work-Exposed on wall
19220mm dia nominal bore
19325mm dia nominal bore
19432mm dia nominal bore
19540mm dia nominal bore
196Providing and fixing gun metal gate valve with wheel of approved quality.
19725mm dia nominal bore
19832mm dia nominal bore
19940mm dia nominal bore
200Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20125 mm nominal bore
202Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group A
203Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
204Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2052 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2062 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2072 X 4 sq. mm + 1 X 4 sq. mm earth wire
2082 X 6 sq. mm + 1 X 6 sq. mm earth wire
2092 X 10 sq. mm + 1 X 6 sq. mm earth wire
2102 X 16 sq. mm + 1 X 6 sq. mm earth wire
2114 X 6 sq. mm + 2 X 6 sq. mm earth wire
2124 X 10 sq. mm + 2 X 6 sq. mm earth wire
2134 X 16 sq. mm + 2 X 6 sq. mm earth wire
214Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
215Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
216Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
217Supply and Fixing of LED Tube Light with batten suitable for up to 1 x 22 watt Led tub light fitting including tube on Surface complate in al respect.
218SITC of High efficacy 18 W Surface mounted Downlight with Aluminium (99% Purity) Sink, available shape. PC diffurser in white powder coated finish with built in electronic low THD (< 10%) LED driver complete in all respect.
219SITC of Decorative, wall mounting , brushed nickle finish fixture with Opal Glass diffuser suitable with 9 w led lamp B22 base complete in all respect.
220SITC of basic all purpose surface and wall mounted 10W LED batten with powdered coated aluminum housing & integrated electronic drive with THD< 10% complete in all respect.
221SITC of designed with beautiful aesthetics using new generation technology in LED to enliven your outdoor and indoor areas in perfect synchronization with functionality and aesthetics. Family of bulkhead designed to complement the geometry of the area with morden design complete in al respect.
222Brush Less DIrect Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
223Supply & fixing of exhaust fan with louvers 300mm sweep, AC single phase 240 volts, 50Hz and connecting up complete including built in louvers and provision of cable 3 core of size 0.5 sqmm (16/0.2 mm ) from ceiling rose to fan as specified and directed.
224Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
225Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
226Supplying and fixing brass batten/ angle holder including connection etc. as required.
227Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
228Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
229Upto 450 mm sweep
230Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
231Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
232Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2338 way (4 + 24), Double door
234Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
235Single pole
236Single pole and neutral
237Double pole
238Triple pole
239Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
240Supplying and fixing of, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
241MCB 63 Amp. FP 10 KA
242MCB 40 Amp. FP 10 KA
243Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV Grade of following size as required complete with in all respect.
24435 Sq mm 3-1/2 Core
245240 Sq mm 3-1/2 Core
246Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
247Upto 35 sq. mm
248Above 185 sq. mm and upto 400 sq. mm
249Supply and burring of safe Earthing Electrode T-19 (Hot Dip Galvanized ), Length up to 3000mm , outer Dia 50 mm inner Dia 25mm, terminal Dia 12mm , outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filed with crystalline conductive mixture (CCM) having anti corrosive & conductive propperty with 50 khs acrivated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board , the cost of G.I. strip will be extra ) along with 30cm square C.I. frame with hinged cover & masonry housing.
250Supply and laying of 25 mmx 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respect.
251Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
252Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
253Supply Installation, testing & commissioning of 500W LED flood light, min 6000 lm LED Light fixture (IP-66) suitable for wall miunting complate with all accessories etc. of an approved make and shade as approved by consultants, including wiring with 3c x 2.5 mm2 FRLS PVC insulated copper wire from pole box to control gear box of fitting . the fixture shall exactly be as per approved make of material. Wipro cat ref; LF45-622-060-57-XX or euqivalent in trilux & philips.
254Supply & fixing of 6 meter GI Octagonal Pole of approved make (top dia 70mm Bottom Dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mte length) on RCC foundation including the cost of foundation including the cost of foundation, foundation bolts, excavation & back filling and with inbuilt junction box with MCB, and wiring till fixture, sleeve in foundation, Required T&P complete in all respect Make: Wipro/Philips.
255Supply and fixing of LR19-561-XXX-57-HY 30W All in One Solar Streetlight, 60Wp High Efficiency Monocrystalline Silicon Panel, 30W+10% System Wattage System lumens 4500+10%, CCT-570K+500K,CRI>70,24 Ah Life PO4 Battery, High Efficiency Battery with higher life of >2000 cycles, Full Power up to 8Hr. (At fully charge battery) Saving mode up to 24Hr. (At fully charge battery), automatic Dusk to Dawn Feature, integral PIR sensor for motion detection.
256Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.
257Phase to Phase -minimum 20mm
258Phase to neutral -minimum 15mm
259Incoming:
260one(1) No. 500 Amp. MCCB-1No.
261Metering
262One(1) No. (0-500V) voltmeter with control fuse & selector switch.
263One(1) No. (0-500A) CT operated Ammeter with selector switch, CTs etc
264One(1) Set of Phase Indication Lamp.
265Bus Bar
266One(1) No. 630A, TPN aluminimum bus of suitable length.
267outgoing
268All outgoing feeders shall be provided with one sets of phase indicating lamps and indication lamp with protection MCB, and Digital Ammeter and CT's.
269100 KVAR Capacitor Panel (1 Nos.160 amp TPN MCCB of 36 KA service breaking capacity and trip setting as required along with heavy duty soild neutral link)
27014 Nos. 63 amp FP MCCB of 36 KA serivce breaking capacity and trip setting as required along with heavy duty soild neutral link.
27112 Nos. 40 amp FP MCCB of 36 KA serivce breaking capacity and trip setting as required along with heavy duty soild neutral link.
272100KVAR Capacitor bank dalta type per SLD connected in , 3 phase , 50Hz . Power capacitors for improving the power factor at the HV switchgear including improving the p[ower factor at the HV switchgear including providing adequate capacity MCCBs, Auto P.F. sensing devices/ relays, protection relays, indication instruments, P.F. meter time delay relays,contactors etc complete with control wiring as per specifications. the capacitor banks and switchgears shall be housed in floor mounted , free standing type sheet metal cubicle fabricated out of 1.6/2mm thick CR Sheet steel, complete with painting, earthing danger board etc as required. 1000 KVAr capacitors the wiring and control shall be provided to connect the capacitors in max .16 steps complete with discharge resistance Auto/Manual operation ON/OFF indication complete as required.
273Metering and protection
274Digital meter with selector switch (RYB)
275Protectionas per SLD
276All ACB's of incoming shall be electrically and mechanically interlocked.
277All outgoing should have anmeter and RYB indications with backup MCB as indications with backup MCB as indicated in single line diagrams.
278Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
279Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2802 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2812 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2824 X 16 sq. mm + 2 X 6 sq. mm earth wire
283Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
28425 mm
285Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
286Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
287Supplying and fixing brass batten/ angle holder includingconnection etc. as required.
288Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioningetc. as required.
289Upto 450 mm sweep
290Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes.
291Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
292Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.
293Single pole
294Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
295100 A, 16 KA,TPMCCB
296Supplying and fixing 40/63A rating, 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Three poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Similar to Legrand DX3 AC MCBs or equivalent.
297Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
298Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
299Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
300Brush Less DIrect Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al bodyPower Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (prefreably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
301Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
302Supply of Totally enclosed exhaust fan, 300mm sweep continously rated highly efficient heavy-dutymotor similar to Crompton Cat. Ref. Trans Air 12\\" or equivalent.
303Supply and fixing of 9W LED retrofit bulb.
304Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
305up to 1.50 m depth
306Pipes 80 mm to 300 mm diameter
307Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
308150 mm. dia. RCC Pipes
309Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
310150 mm. dia.
311Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
312With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
313Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
314up to 1.50 m depth
315Pipes 80 mm to 300 mm diameter
316Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete.
317150 mm. dia. RCC Pipes
318Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
319250 mm. dia.
320Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
321Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
322With common burnt clay FPS (non modular) bricks of class designation 75
323(i) For Sewer Line
324Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
325Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).
326With common burnt clay FPS (non modular) bricks of class designation 75
327(i) For Sewer Line
328Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
329Cost of Filtration Tank (2.5 m dia with 3.00 m deep)
330Cost of P.V.C. PIPE Drain
331Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
332Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
333Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm
334Fine dressing of the ground
335Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
336Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately).
337With grass Turf
338Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
339Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :
340Holes 90 cm dia, and 90 cm deep
341Supply and stacking of Bottle palm plant of ht. 210-240 cm bottom girth 30-35 cm well developed in big HDPE bags.
342Water Tank (CPWD PAR 01-04-2023 Sl. No. 4.1)
343Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenchesor drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock
344Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
345Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
346Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8 graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation.
347Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
348Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). PLINTH BEAM
349Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). LINTEL
350Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). SLAB
351Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). SLAB BEAM
352Centering and shuttering including strutting, propping etc. and removal of form for :
353Foundations, footings, bases of columns, etc. for mass concrete
354Suspended floors, roofs, landings, balconies and access platform
355Lintels, beams, plinth beams, girders, bressumers and cantilevers
356Weather shade, Chajjas, corbels etc., including edges
357Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
358Brick Work with common burnt clay ( non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand)
359Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size)
360Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
361Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- Anti-Termite Treatment of the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
362Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
363Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete size 250x16 mm
364Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
365250x10 mm
366150x10 mm
367Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm
368Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
36935 mm thick single leaf shutters
370Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
371Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
372Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
373Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes
374Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
375Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
376(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
377(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
37812 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
37915 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand)
38015 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. In plinth.
381Add for plaster groove in plastered surface or moulding to R.C.C. projections.
382Making drip course in sun shade or facia as per direction of Engineer incharge including supply of all materials, labour T & P etc for proper completion of the work.
383Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by approved make & colours), of 1st quality conforming to IS : 15622, of approved make, in colours & shade, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
384Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
385Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
386Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
387Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
388Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
389Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
390Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
391110 mm diameter
392Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
393Coupler
394110 mm
395Bend 87.5°
396110 mm bend
397Shoe (Plain)
398110 mm Shoe
399Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
400110 mm
401Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
402Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :
403W.C. pan with ISI marked black solid plastic seat and lid
404Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.
405White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
406Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
407Providing and fixing unplasticised PVC connection pipe with brass unions
40845 cm length
40915 mm nominal bore
410Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge.
411Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
412a) 15 mm nominal bore
413Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931
414a) 15 mm nominal bore
415Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath)
41615 mm diameter
417Providing and fixing C.P. brass shower rose with 15 or 20mm inlet
418150 mm diameter
419Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:
42015mm nominal bore
421Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
422Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
423Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
424450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
425Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
426Concealed work including cutting chases and making good the walls etc.
42720mm dia nominal outer dia pipes
42825mm dia nominal outer dia pipes
429Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
43032mm dia nominal bore
431Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
432Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C
433Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4342 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4352 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4364 X 16 sq. mm + 2 X 6 sq. mm earth wire
437Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required.
43825 mm
439Supplying and fixing brass batten/ angle holder includingconnection etc. as required.
440Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioningetc. as required.
441Upto 450 mm sweep
442Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes.
443Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
444Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.
445Single pole
446Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminalspreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
447100 A, 16 KA,TPMCCB
448Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
449Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
450Providing and fixing 25 mm X 5 mm G.I. strip on surface or inrecess for connections etc. as required.
451Supply of Totally enclosed exhaust fan, 300mm sweep continously rated highly efficient heavy-dutymotor similar to Crompton Cat. Ref. Trans Air 12\\" or equivalent.
452Supply and fixing of 9W LED retrofit bulb. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56245526
AUTHORITY Government Departments
TENDER VALUE 4.94 Crore
LAST DATE 13-07-2026
Authority
Authority Name Uttar Pradesh Jal Nigam
Work Description Tender for Renovation Work Of Pt. Shiv Kumar Shastri New Hostel In S Urnanand Sanskrit University At Varanasi
Basic Detail
Tender No 895/Karya-6/(26)/28 Dated 22-06-2026
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 01 Jul 2026
Submission Date 13 Jul 2026
Open Date 14 Jul 2026
Finance
Tender Value 4.94 Crore
Tender Fee 11800
EMD 9.90 Lakhs
Exemption Not Available
Document List
21bd0b9f-3a27-4e50-8d44-08b83481d310.html
BOQ_2185717.xls
TenderDocuments.pdf
Tendernotice_1 (27).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

21bd0b9f-3a27-4e50-8d44-08b83481d310.html

xls

BOQ_2185717.xls

pdf

TenderDocuments.pdf

pdf

Tendernotice_1 (27).pdf

TenderDetail
Loading tenders