Housing Urban and Rular Development Government Departments Closing in 17 days TDR #56244695

Tender For Construction Of Police Thana Sadar Bazar At Jodhpur Commissionerate Based On Pwd Integrated Bsr 2022 And Electrical Bsr 2022 Rajasthan

Issued by Government Departments · Jodhpur, Rajasthan
Tender Value
3.10 Crore
Estimated cost
Bid Submission
22 Jul 2026
17 days left
EMD
6.20 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Police Thana Sadar Bazar At Jodhpur Commissionerate Based On Pwd Integrated Bsr 2022 And Electrical Bsr 2022 Rajasthan

BOQ

Name of Work:- Construction of Police thana Sadar Bazar at Jodhpur Commissionerate Based on PWD integrated BSR 2022 and Electrical BSR 2022 Rajasthan
Sl. No. Item Description
1Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-charge.
2Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.
3Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:14.9.1 In lime mortar.
4Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix.
5CARRIAGE OF MATERIALS Earth, Sand, Lime, Morrummanure or sludge 20 KM
6Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead :Of area 3 square meter and below.
7Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if availableHard rock(blasting prohibited) useful material 30%
8Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand.
9Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyound 60 cm girth upto including 120 cm girth
10Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand
11Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level :- M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
12Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
13Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).
14Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix
15Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix
16Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix.
17Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
18Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : -- Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
19Columns, pillars, posts and struts etc.
20Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) :- Thermo-mechanically Treated bars (Conforming of relevent IS code)
21Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughout in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc:
22Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand)
23Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.Cement mortar 1 : 6 (1 cement : 6 coarse sand)
24Add extra providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry .
25Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Sand or other approved stone 50mm thick.
26Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Kota stone minimum 30mm thick.
27Supplying and fixing machine cut fine dressed Red/Pink sand stone dasa or coping, with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 50 mm thick
28Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
29Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
30Add extra over item No. 7.12 7.13 for marble printed,granite shade tile.
31P & F 1st qualityVitrified Porcelain Polished tiles on floor,skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigmentetc complete.size 600 mm X 600 mm
32Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
33Supply and fixing in cement mortar welded hand railing made out of MS round or square bars, flats etc. for staircase or verandah as per design complete in all respect (wooden or PVC hand railing to be paid extra) with priming coat of red oxide.
34Extra for providing D type pipe head as top of hand railing
35Grading roof for water proofing treatment with water proffing compound :-Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
36Crazy marble stone flooring 20mm thick marble stone with black or of specified colour topping including filling the gaps with cement marble chips mix in proportion of 4 : 7 (4cement: 7 white black or white or black marble chips) size from 1mm to 4mm by volume and under layer of 25mm thick cementconcrete [1:2:4, graded stone aggregate 12.5mm nominal size] rubbing and polishing and cement slurry etc. complete :
37Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
38Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete.
39Cement concrete flooring grade 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete :( Used Banas / Bikaner sand ) :- 75 mm thick with 20 mm thick nominal size aggregate.
40Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :- For area of each slab from 2001 to 5000 Sq.Cm 40mm thick slab
41Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete .For area of each slab upto 2001 Sqcm
42Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
43Extra for Mirror polishing on terrazzo/Kota stone work where ever required to give high gloss finish complete.
44Random rubble dry stone Kharanja under floor.
45Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish : 20 mm thick
46Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20 mm thick
47Plaster on new surface on walls in cement sand mortar 1:6 including raking of joints etc. complete fine finish 12 mm thick.
486mm cement plaster to ceiling of mix 1:3 (1 Cement : 3 fine sand)
49Making grooves as per design in plaster 10mm to 20mm wide.
50Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mm and 10 mm thick as per approved design
51Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete :- New Plastered Surface (three or more coats)
52Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
53Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision :- New Work
54Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
55Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (i) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. (ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners, junction with polymer mixed slurry.
56Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick bats complete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification.
57Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.:- Good quality South Black :- Above 3601 Cm2 Slabs
58Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone WorkFull Edge moulding
59Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone WorkHalf Edge moulding
60Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete
61Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished seamless type tubes.
62Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvaiumeseel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm shets be casted with regular modified plyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate at made at to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and foe a minimum up to 12mts with all scaffolding.
63Add extra for 0.60mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel sheet in place of 0.50mm thick
64Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).Grade 304
65Supply and Installation of WALL – PREFABRICATED INSULATED PPGL PANEL: Walls: Insulated sandwich panels for wall of total thickness mentioned below. Panel shall have 0.50mm (+/-0.04mm) thick pre coated metal sheet on both sides of rigid PUR insulation. The pre-coated metal sheet shall be PPGL (Pre Painted Galvalume Sheet with AZ coating) sheet having SDP (Super Durable Polyester) colour coat of 18 micron (min). The panels shall be vertically joined together with adjacent panel by tongue and groove joints. For joining, wall panel's metal sheet facings must have lengthwise flange (U shape) of 8mm x 8mm on groove side and 8mmx12mm on tongue side of panel. The pre-coated metal sheet (PPGL) must also be pre-strengthened by full lengthwise stiffening with semi-circular beading of 12mm width & 3 to 4mm depth at 240 (+/-5) mm pitch. Panels may have optional provision for inbuilt electrical conduit running lengthwise atvertical center of specified panels. The insulation core shall be self-extinguishing DIN 4102,Class B3 fire retardant class rigid PUR with thermal conductivity of 0.025 W/mK and with density of 40kg/m3 (+/-2kg) suitable for temperature range of -30 degree C to +80 degree C. The panel must be made using glue-free high pressure pressing self-bonding method. PPGL sheet on both sides of panel shall have a min15 micron protective plastic guard film to avoid scratches during transportation.:_ Thickness 55mm (+/- 2mm)
66Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc.Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al.Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).For fixed portion Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
67For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). :- Powder coating aluminum ( minimum thickness of powder coating 50 micron)
68Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. :- Prelaminated particle board with decorative lamination on both sides.
69Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) :- With glass panes of 5 mm thickness
70Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. :- With stainless steel cover plate
71Providing and fixing 100 mm brass lock without handle for aluminium door, or approved quality, make & design as directed by Engineer incharge
72Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge :- Powder coated minimum thickness 50 micron aluminium
73Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge :-
74S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws at not exceeding 150mm distance at all heights with all lead and lift with scafolding.
75Filling the gap upto 5 mm depth and 5 mm width in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
76Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete.
77Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' : 35 mm thick ,Commercial Veneer both side
78Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13.
79Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge :- Window openable.
80Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –chargeWindow fixed.
81Extra for additional shutter in pipe section windows with wire gauge 14 mesh x 24 gauge
82Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
83Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size. :- Welded mesh 25 mmx 25 mm x 16gauge
84Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge
85Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
86Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint.
87Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension).With 75 mm opening when closed.
88P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.:- 110 mm dia
89P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: (110 mm) Bend 87.5
90P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: (110 mm) Door tee
91P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: (110 mm) Pipe Clip
92M-35,60mm thick to be used in light traffic (Light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 KN laden weight, or an equivalent up to 0.5 million standard axles (MSA) for a design life of 20 years (Astandard axle is defined as a single axle load of 81.6 KN) like pedestrian plazas, shopping complexes ramps, car parks, office driveways , housing colonies, office complexes, rural roads with low volume traffic, farm houses , beach sites, tourist resorts, local authority footways, residential roads, etc.. :- Category ‘B’ Denated only two side like I,Z,T shape etc. as per IRC SP 63:2004
93Part B-Rain Water Harvesting
94Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS:2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe :200 mm dia Nominal bore.
95Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985 :Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985 200mm-do-.
96Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm
97Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with 40 mm thickness Diameter 900 mm
98Providing & lowering of G.I. Pipes, flange pipe including rubber washer and nuts of 8 mm dia complete in all respect I.S.I. Make.B Class 50 mm dia.
99Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge.
100Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm
101Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 3 to 5 mm
102Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.
103Part C-Boundary wall
104Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level :- M7.5 grade Nominal Mix 1: 4: 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
105Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall in : Cement Mortar 1:6 (1-Cement:6-Sand).
106Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand).
107Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
108Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. All work up to plinth level IS 456-2000:1:1:2 (1-Cement:1-Coarse sand:2-graded stone aggregate 20 mm nominal size).
109Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1- Cement:3-coarse sand) and making good the joints excluding cost of centering shuttering and reinforcement IS 456-2000:1:1:2 (1-Cement:1-coarse sand:2-graded stone aggregate 20 mm nominal size).
110Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for . Columns, pillars, posts and struts etc.
111Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) :- Thermo-mechanically Treated bars (Conforming of relevent IS code)
112Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
113Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25 mm thick
114Providing and laying cement concrete including curing,compaction etc. complete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts, struts, buttresses, string orlacing courses, parapets, coping, bed blocks, anchor blocks,plain window sills, fillets, levelling course etc up to floor fivelevel excluding the cost of centering and shuttering.M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate40mm nominal size).
115Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision :- New Work
116P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor Size 580x440mm.
117P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor
118P & F Premium quality water closet Seat Covers with brass hinges complete Solid PVC (ISI marked) grade-I White for EWC.
119P & F Premium quality Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make as per Engineer-in-charge with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall :WVC with C.P. brass bend.
120P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 550 mm x 400 mm dia for counter top
121P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 550 mm x 400 mm
122P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (large) or half stall size 610x400x80mm.
123P & F C.P. brass Urinal Flush Pipe set complete with flanged brackets of approved make. For 2 Urinals
124P & F C.P. brass Urinal Spreader for stall urinal of approved make.
125P & F Bottle Trap of approved make : C.P Brass 40 mm
126P & F Towel Rail or Ring of approved quality/make: C.P. brass Towel Rail elbow type with concealed screws size 600 mm (Heavy duty).
127C.P. Brass Towel Ring revolving type
128P & F Tooth Paste & Brush Holder of approved quality/make: Stainless Steel
129P & F Shower arm 15mm dia of approved quality/make. size 370mm.(-do-)
130P & F Bath Shower of approved quality/make. C.P. brass of Heavy & superior quality, revolving with adjustable key 150mm.
131P & F Extension Pipe for bib cocks of approved quality/make.150 X 15mm.
132P & F Jet spray for water closet with C.P. Copper Tube flange of approved make.
133Providing & fixing C.P.flange for 15mm dia taps.
134P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore.
135P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: Long body, 15mm nominal bore weight not less than 690 gm
136P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: C.P. Brass Concealed stop cock 15mm
137P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. with 37 cm long pipe and nut.
138P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia
139P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87 .5 110 mm dia
140P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Coupler (socket) 110 mm dia
141P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:Plain Tee 110 mm dia
142Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 75 mm dia
143Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110mm dia
144Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Coupler 75mm dia
145Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Coupler 110mm dia
146Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend 87.5 Dg. 75mm dia
147Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend 87.5 Dg. 110mm dia
148Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Single 'Y' with Door 75mm dia
149Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Single 'Y' with Door 110mm dia
150Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Door Bend 87.5 Dg. 110mm dia
151Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Single Tee 75mm dia
152Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Single Tee 110mm dia
153Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Single Tee with Door 75mm dia
154Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Single Tee with Door 110mm dia
155Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Nahni Trap without Jali 4” 110mm dia
156Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Vent Cowel 110 mm dia
157Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M
158Add extra over item 3.19.1 for every additional 0.10m depth above 0.5 m depth.
159P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. 32mm dia nominal bore 'B' Class
160P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:Exposed on wall 15 mm dia nominal bore 'B' Class
161P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:Exposed on wall 25mm dia nominal bore 'B' Class
162Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 20mm nominal outer dia pipes
16325 mm nominal size
16432mm nominal size
165Construction of Cement Concrete Chamber 125mm dia.C.P. Brass grating
166Construction of Cement Concrete Chamber 125mm dia on depressed floor upto 45cm height from floor with :C.P. Brass grating
167Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) all around S.W. pipe including 15 Cm. thick bed concrete as per Rajasthan PWD Specification. (Width W= Diameter of pipe in Cm+40 Cm.)( Excluding cost of pipe)100mm dia
168Making of hole in R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cutting machine complete as per direction of EI From diameter 100mm to 150mm
169Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M
170Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :15mm dia nominal bore
171Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size : 20mm dia nominal bore
172Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :32mm dia nominal bore
173P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity.
174P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore.
175P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : 20mm nominal bore.
176P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :32mm nominal bore.
177P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete :Brass wt. Not less than 300 gm,15mm.
178Hoisting Charges for each floor :For items 2.26.5 to 2.26.8
179P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers.Other sizes
180Construction of septic tank in all type sof soil with 40cm thick masonry in CM 1:6 15cm thick CC bed of 1:5:10 M-15 grade CC flooring & over stone slab covering, 80mm thick slab jointing of slab in CM 1:3, Ralthal, Kharanja, 50mm thick stone partiton walls, 20mm thick plaster in CM 1:6 finished with neat floating cement, 4Nos C.I. foot rests of approved design, two No. 450mm dia 25Kg each C.I. cover with frame, earth work etc. complete as per approed drawing incl. disposal of surplus earth wtihin a lead of 50mtr. IS 2470 (Part-I) 1985.Size 200x100x130cm (for 10users)
181Construction of septic tank in all type sof soil with 40cm thick masonry in CM 1:6 15cm thick CC bed of 1:5:10 M-15 grade CC flooring & over stone slab covering, 80mm thick slab jointing of slab in CM 1:3, Ralthal, Kharanja, 50mm thick stone partiton walls, 20mm thick plaster in CM 1:6 finished with neat floating cement, 4Nos C.I. foot rests of approved design, two No. 450mm dia 25Kg each C.I. cover with frame, earth work etc. complete as per approed drawing incl. disposal of surplus earth wtihin a lead of 50mtr. IS 2470 (Part-I) 1985.Size 230x110x150cm (for 20users)
182Construction of septic tank in all type sof soil with 40cm thick masonry in CM 1:6 15cm thick CC bed of 1:5:10 M-15 grade CC flooring & over stone slab covering, 80mm thick slab jointing of slab in CM 1:3, Ralthal, Kharanja, 50mm thick stone partiton walls, 20mm thick plaster in CM 1:6 finished with neat floating cement, 4Nos C.I. foot rests of approved design, two No. 450mm dia 25Kg each C.I. cover with frame, earth work etc. complete as per approed drawing incl. disposal of surplus earth wtihin a lead of 50mtr. IS 2470 (Part-I) 1985.Size 400x140x150cm (for 50users)
183Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 300 Cm. dia outside & 300 Cm. depth .
184Add extra if Soakage Well is filled with dry stones.
185P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded in wall & 10 cms. projected out complete.
186Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame.
187Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.size 450 x 450mm depth upto 0.5 M Cement cover with frame
188P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type.Trap size 225 X 150 mm, ferrow cement cover with frame Internal Chamber size 450 X 450mm.
189P & F Flush Valve (Hydraulic) with level complete (IS : 9758 Mark) of approved make :32mm nominal bore.
190P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : 1.0 mm thick stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer-in-charge with large waste coupling.45 x 20 x 8 20x16x8 (with drain board)
191Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodate housing and assembly pipe of following sizes in all types of alluvium strata by percussion/ rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I -& II) 1979 as amended upto date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes, with supply and wrapping of coir-rope, wherever necessary, for arresting fine sand particles. The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water).200mm –do-.
192Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 200 mm –do-
193Development of tube well as per IS specification using suitable compressor to give sand free water for required yield of the gravel packed tube well.
194Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work. 200 mm Nominal bore of pipe
195Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985.200mm-do-.
196Testing verticality of tube-well by plumbing system and yield test and draw down test by pumping system as per IS: 2800 (Part II) 1979.
197S & F tube well cover of M.S.sheet (6mm thick) with nuts and bolts complete for casing size:200mm dia
198S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
199Providing & lowering of G.I. Pipes, flange pipe including rubber washer and nuts of 8 mm dia complete in all respect I.S.1239 Marked. B Class 50 mm dia
200Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet's &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR
201Short point (up to 3 mtr.)
202Medium point (up to 6 mtr.)
203Long point (up to 10 mtr.)
204Wiring of twin control light point with 1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible copper earthconductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P- III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, roundtiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceilingrose / holder / 3 way connector ,Modular face plate with grid plate,screws, making connections, testing etc. as required. For specificationof copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiringaccessories refer Chapter E - 04, E - 05 & E - 07 For additional technicalparameters of product / work refer Annexure 'A' attached with this BSR
205Long point (up to 10 mtr.)
206Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
207On board
208Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure 'A' attached with this BSR
209Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Lightfixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity /transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , withShort & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) ,maximum power consumption should not more than the specified rating and Fixture shall be of BISstandard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LEDfixtures. (LM79 &LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer incharge. All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
210Surface Moutning
211Minimum lumen output 4200 lm
212Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
2131170mm(+/-10%) LED batten with min. lumen output 2200 lm
214Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and dinbar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR
215Metal door (single phase) IK-09 and IP-43 with Metal end box
2166 Way (6+2)
217Metal door (Three phase) IK-09 and IP-43 with Metal end box
2186 Way
219Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure'A' attached with this BSR
220Double pole MCB(With B/C curve tripping Characteristics)
22140 A rating
222Single pole MCB (With B/C curve tripping Characteristics)
2236 A to 32 A rating
224Triple pole MCB (With B/C curve trippingCharacteristics)
22550/63 A rating
226Four pole MCB (With B/C curve tripping Characteristics)
22750/63 A rating
228Providing & Fixing of Recessed/surface mounting heavy dutyVertical TPNDistribution board with Metal end box with provisionof incomer suitable for MCB / RCCB and SP / TP MCB as outgoing,made out from Galvanized steel / CRCA sheet not less then 1.2 mmthick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powderpainted with reversible door (for double door DB only ) completewith insulated 100 A rating copper bus bar, neutral bars withshrouds, earth bar , color coded interconnecting wire set ofsuitable rating and din bar,masking sheet, making internal DBterminations with copper lugs, ferrules, detachable gland plate,including making connections, testing etc. as required. OEM shallhave submit NABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additionaltechnical parameters of product / work refer Annexure 'A' attachedwith this BSR
229Double door IK-09 & IP-43 with Metal end box
2306 Way(8+18)
231Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR
2322 x 2.5 sq. mm. + 1x1.5sqmm
2332 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
2343x 1.5 sq.mm
2354 x 6.0 sq.mm
2361 x 4.0 sq.mm
2371 x 1.5 sq.mm
2382 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
239S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure 'A' attached with this BSR
24020 mm
24125 mm
24232 mm
243Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
2446.0 Sq. mm
2454 core
24625.0 Sq. mm
2473.5 core
248Supplying and making one end termination with Nickel plated heavy dutybrasssingle compression gland (as per IS 12943-1990)) SIBG type consisting of CheckNut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, CompressionNut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped withcrimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated& PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade asrequired.All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
2493 x 25.0 sq.mm
250Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb inexisting holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . foradditional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR
2519 Watt
252Providing & Fixing of of Double ball bearing, copper wounded capacitorstart single phase metallic blade fresh air fan, in existing openingincluding cost of hardware , flexible 3 core copper conductor ,makingconnections, testing etc. as required. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR
253300 mm sweep
254Providing & Fixing of Heavy duty capacitor start, copper wound Doubleball bearing 900/1400 RPM single phase Exhaust fan conforming toIS:2312 ISI marked in existing opening including making connectionstesting etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR .
255380 mm sweep(900/1400 RPM)
256Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 forwater supply suitable for submersible & jet pump with requiredfittings ie socket, elbows, tee etc. complete in all respect. All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR
257for vertical installation
25875 mm OD 6 kg / cm2
259Plate Earthing as per IS:3043 with copper Earth plate of purity >95% ofsize 600mm x 600mm x 3.0mm by embodying 3 mtr. below the groundlevel with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessorieslike nut, bolts, reducer, nipple, wire meshed funnel, and Heavy dutyweather proof poly-propylene earth pit chamber with lockable Jam freelid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.andembodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less asrequired & must record by engineer in charge during site visit and ensureto enter in measurment book. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR .
260Supply and installation of high tensile low carbon steel rod molecularlybonded with 99.9 % Copper thickness (250 microns) and confirming toUL 467, IS/IEC 62561-2 of following size and length and as per pointmentioned (a), (b), [c), (d), (e) below :-(a) Bore a hole of dia. 100 mm of required length, Place the rod in thecentre of Hole
261filled with anti corrosive conductive compounds with the permanentsealings at both the ends, CPRI/ ERDA tested with RMS capacity ofminimum 30 KA for withstanding 1 second .To ensure the moisturecontent and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for3000mm of resistance lowering earth enhancement material shall beused as a backfill compound. The compound shall be tested form NABLacredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & highconductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 withlatest amendemnts
262Connect the rod with copper Strip/Conductor/Wire with suitableclamp made from tinned copper and SS 304 BoltPlace Heavy duty weather proof poly-propylene earth pit chamberwith lockable Jam free lid suitable for safe working load 5000 Kg or moreof size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.
263Testing of earth resistance for value of 5 ohms or less as required &must record by engineer in charge during site visit and ensure to enter inmeasurment book. Test certificates for confirming above standards from OEM ismandatory. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \\"A\\" attachedwith this BSR .
26425 mm thick and 3 Mtr. Long
265Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
26610 SWG copper. Wire
267Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
268LED Street Light fixture with Minimum lumen output 12500 lm
269Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressurediecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beamangles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number havingefficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System levelLuminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff@>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA.driver should be Phase to phase protectionof 440 V for 4 Hrs. Electrical Connector , Surge Protection Min>=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hourswith 70% of Initial Lumens maintained, CRI>70 andCCT5700K355K.ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbe IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LEDfixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shallbe submitted. All as per pre approved by Engineer in charge. Foradditionaltechnical parameters ofproducts/ work , refer Annexure \\"A\\" attached with this BSR
270High Power LED Flood Light Minimum lumen output 14800 lm
271Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I.Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. asrequired. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR .
27232 mm Dia.
273Providing & Fixing of 1200 mm sweep BLDC technology power saving ceiling fan which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe up to 80 cm , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
274Without Remote
275P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm lengthextended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A'attached with this BSR
276Providing & Fixing of modular type 120 W Step Fan regulator duly ISImarked (IS 11037:1984 ) with CM/L no. printed made out of unbreakableand fire retardant vergin poly carbonate with brass terminals and captivescrews & silver alloy contact tip with IP-20 rating , including all as per preapproved by Engineer in charge,making connections, testing etc. asrequired. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR
2775 step fan regulator 2 Module 360 dgree rotating
278Providing & Fixing of following modular accessories as per PWDspecification for electrical Works, made out of unbreakable and fireretardant vergin poly carbonate with brass terminals and captive screws &silver alloy contact tip with IP-20 rating , including all as per pre approvedby Engineer in charge,making connections, testing etc. as required. Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR
279RJ-11 telephone jack single line
280Blanking plate
281Modular MCB 6 A to 32 A SP
282USB Charger 1 A - 1 M with BIS mark
283T.V. coaxial socket
284P & F Krone module with base frame in the recess / surface made out of1.2 mm thick sheet steel box, front openable, having locking arrangementsduly powder painted,including dressing, ferruling and punching oftelephone cable with krone tool etc. as required. For additional technicalparameters of product / work refer Annexure 'A' attached with this BSR
28520 Pairs
286Providing & Fixing of extra down rod of 15 mm dia . ERW (Electricalresistance welded ) of 1.6mm nominal thick medium duty steel pipeincluding cutting, threading, drilling, fixing quarter pin etc as reqd. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with thisBSR
287P/Laying ISI marked P.V.C. insulated submersible cable confirmingto(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemade from 99.90 % purity copper, stranding in acc. to IS:8130/IEC60228 for lower watt loss , oxygen free for less chances of oxidization,insulation PVC type A/C/D , flame retardant as per IS 10810-53, betteramperage rating as per IS:3961 part 5, existing pipe / open trench /Cable tray / on surface including making connection etc. as required.For additional technical parameters of product / work refer Annexure'A' attached with this BSR
2886.0 Sq.mm 3 core flat / Round
289SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB)made of flame retardent & heat resistant material having followingcurrent rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L &S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face andcentralised adjustable, trip free mechanisum, true contact positionindicator, line load interchangeability, designed for both horizontal &vertical mounting without any adverse effect on electrical performance,suitable for operation upto 55 degree and without derating upto 40degree, pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breakingcapacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock &rotary handle , including making connections etc. as required.OEM shallhave submit NABL / CPRI / ERDA accrediated lab type test certificatebefore execution All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR
2904 pole MCCB With Thermal Magnetic release
291up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
292Supplying and drawing coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor of alum. alloy braid in existing surface or recessed conduit/casing capping including making connections as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
293RG - 6
294Supplying and drawing PE Insulated & PVC Sheathed unarmouredtelephone cable with 0.5 mm dia. Solid Annealed electrolytic gradebare Copper Conductor as per IS: 8130/84 &confirming to TECspecification GR / WIR/06-03 March 2002 in existing surface orrecessed conduit/casing capping. including ferruling on each pair forIdentification etc. as required. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR
2952 pair
29620 pair
297Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC,UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable asper latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balancedtwisted in pairs, seperated by a cross-member fluted pair divider & protected by PVCJacket. Certified performance in a 4-connector configuration upto 100 Mtrs channelrequirements & transmission frequencies up to 250 Mhz. in existing MS/PVCConduits/casing capping including making connections to Information outlets and PatchPanels with jack & ferruling at both ends for identification with necessary tools forpunching, stripping, crimping and testing etc as required complete in all respect. All as perpre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR .
298Supply & fixing of square Faceplate for Flush / Surface Mount Information OutletsSingle/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions shouldbe 86mm X 86mm as required complete in all respect. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , refer Annexure \\"A\\"attached with this BSR
299Single Aperture
300Supply, Installation, Testing and Comissioning of Rack mounted 19\\" 1U, Cat6 24 Portloaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), ModularPatch Panels with Rear Cable management system and mounting hardware to mount thepatch panel. Should have port identification numbersprinted/engraved on front of thepanel. Etc. as required.All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
301Modular Patch Panel Loaded with Cat -6 I/O
302Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patchcords should be constructed of minimum 23/24 AWG, stranded bare Copper cable withFRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectorswith strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A applicationcomplying to latest ammendments Category 6/6A Standards, According. to TIA568C.2,ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirementfor 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cablecompatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af /IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts forlong durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digitalvideo and broadband/baseband analog video, Voice over internet protocal (VOIP).All as perpre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR .
303Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord
3041 Mtr
305Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double SectionCommunication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,front sturdy sheet steel frame folded from one piece and welded with minimum 5mmtoughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All roundprotective channel on the door aperture, lock integrated on front door, top and bottomcover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angleswith wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cablemanager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long powerchord for supplying power to switches, fans etc along with earth continuity kit, indicator,moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.Allas per pre approved by Engineer in charge. For additional technical parametersofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
3069 U Rack with Width 600 mm & Depth 400 mm + 100 mm
3076 U Rack with Width 600 mm & Depth 400 mm + 100 mm
308Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFPGiga Ports (provision for Fiber Giga connectivity) with related LANBase Software includingmaking connections etc as required.All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \\"A\\" attached with thisBSR
309Supply and Installation of unsheilded/360 degree sheilded Information outlets made of highimpact plastic body with ABS, FR Grade halogen free material with provision for protectionagainst dust in jack, suitable for Cat 6/6A application complying to latest ammendments,According. to Cat. 6/6A channel, It should support channel as well as componentsrequirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6Aunshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWGsolid/strandedwire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jackshould have tooless/impact termination on reliable copper tin plated Insulationdisplacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and compliedwith ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Shouldsupport Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voiceover internet protocal (VOIP) Specifications in existing modular/MS Boxes along withnecessory connections as required.All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure \\"A\\" attached with thisBSR .
310Cat 6, Un-sheilded Information Outlet
311Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 starrated) storage water heater with outer casing made of EngineeringPlastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass -line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressureInner tank, Glass Line Coated , mineral filled heating element, stem type,snap action adjustable thermostat , Dual indicating lamps Injected PUFinsulation, Multi Function Valve etc. as required held in position with2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0Sqmm PVC insulated & sheathed copper conductor and 16 A/25A threepin plug top with Portable Residual Current Device ( PRCD ) , includingmaking inlet, outlet Flexible alloy connection, testing etc. as required.All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached with thisBSR .
31225 Ltr
313Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC type FireExtinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powdercoated Internal & External Surface Deep drawn cylinder body of Mild SteelCR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve withInbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressuregauge, 450 mm long EPDM discharge tube, QR code for Product Traceabilityincluding Fixing on wall with suitable Anchor Fasteners as required offollowing capacity. Test Certificates of all the Parameters along with Hydrotest & Burst test (For Cylinder Body) Certificate from OEM / External NABLAccrediated Lab is to be submitted. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR .
314Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD MidPower LED Downlight with power coated die-cast aluminum housing with UV Stabilizednon yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, withShort & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with ,70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more thanthe specified rating and Fixture shall be of BIS standard and trade mark certificate( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures.(LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approvedby Engineer in charge. For additional technical parameters of products/ work , referAnnexure \\"A\\" attached with this BSR .
315Surface Mounting (with extruded alumn. Housing )
316Minimum lumen output 650 lm
317Minimum lumen output 1950 lm
318Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
3191-2 Module
320Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
321Wall mounting type with Adjustable Vertical Angle
322SITC of Contactor OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
323For Three phase Submersible / Mono block pump
3243.0 HP to 5.0 HP ( DOL starter )
325SITC of Radial / mixed flow ISI marked water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034 : 2018 and IS: 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 with required accessories including making connection suitable for Bore well. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
326150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.
3275.0 HP, 3-Ø, (68 - 102)Mtr, (225-85) LPM
328SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal - T/C Vs T/C, Thrust bearing shall be of carbon + S.S.The stator body of single phase pump shall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electro deposition (CED) coated and other construction material should be confirming to IS : 14220: 2018 . The overall performance of pump shall confirm to BEE energy efficiency level of 3 star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011, including making connection etc as required complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
3292.0 HP, 1-Ø, (12 -25) Mtr, (350 - 115) LPM
330Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
3311.5 TR ISEER not less then 3.8
332Supply, installation, testing and comissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
33315.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
3349.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick)
335Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
33620 mm
337Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
338Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler with hermetically sealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick) and tank (0.5 mm thick) , stainless steel water tray,minimum two nos Brass Chrome plated faucets and suitable drainage system complete in all respect with required height MS fabricated and Painted Angle iron frame ( Cost of frame to be paid Extra )complete in all respect of the following capacity. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
339cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs
340Supply, installation, testing & commissioning of following size & Material Lightning protection system accessories meeting requirement of IS/IEC 62305 and tested as per IEC 62561-2 / IS 18925 (Part 1-7) : 2025 as required.
341100 microns Copper bonded steel Solid round conductor 10 mm dia.
342Aluminium alloy Solid round conductor 8 mm dia.
343SS 304 Solid round conductor 10 mm dia.
344Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 2000 mm 40 mm GI pipe as mast
345Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 3000 mm 40 mm GI pipe as mast
346Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 5000 mm 56/40 mm GI pipe as mast
347Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 5000 mm 76/56/40 mm GI pipe as mast
348Alluminium alloy Vertical Air termination 16/10 mm with SS 304 Clamp of Size 1000 mm for Wall
349Alluminium alloy Vertical Air termination 16/10 mm with SS 304 Clamp of Size 2000 mm for Wall
350Alluminium alloy Vertical Air termination 16/10 mm with SS 304 Holder of Size 1000 mm for Parapet
351SS 304 Clamp to join Vertical Air terminal and 8/10 mm round conductor
352SS 304 Clamp to join Vertical Air terminal and 25 mm x 3 mm flat conductor
353SS 304 holder for 8/10 mm round conductor on Parapet
354SS 304 holder with Concrete base for 8/10 mm round conductor on Flat roof
355SS 304 clamp connector for 8/10 mm round conductor on metal structure
356SS 304 cross connector for 8/10 mm round conductor
357Alluminium alloy expansion piece with connector for 8/10 mm round conductor
358Alluminium alloy straight,cross & T connector for 8/10 mm round conductor
359SS 304 straight connector for 8/10 mm round conductor
360SS 304 conductor holder for 25 mm x 3 mm Flat conductor
361SS 304 holder with Concrete base for 25 mm x 3 mm Flat conductor on Flat roof
362Alluminium alloy expansion piece for 25 mm x 4 mm flat conductor
363SS 304 cross connector for 25 mm x 3 mm flat conductor
364SS 304 test joint with Polycarbonate enclosure with copper flat with 4 holes of 8/10 mm dia to connect round conductor
365SS 304 test joint with Polycarbonate enclosure with copper flat with 4 holes of 8/10 mm dia to connect round conductor
366SS 304 Earth stud for air terminal and 8/10 mm round conductor
367SS 304 Equipotential Bonding rail 500 x 50 x 10 mm
368Lightning Surge Counter designed to record and display lightning strike events. The counter shall feature a 3 digit LCD screen (0-999 events) for clear event tracking and operate on a battery powered system.
369Supply, installation, and testing of an Early Streamer Emission (ESE) Air Terminal, designed and tested in accordance with NFC 17-102 standards, with Delta T ( Initiation Advance ) time tested and certified by an ILAC-accredited high-voltage test laboratory. The air terminal shall be constructed from corrosion-resistant materials to ensure durability and long-term performance. It shall be installed at the highest point of the structure and mounted on a mast of minimum 5.5 meters or as determined by the initiation advance time (ΔT) calculations, ensuring the required protection radius. The protection radius shall be determined as per NFC 17-102, based on the level of risk protection required (Levels I to IV), with proper Earthings integration for effective lightning dissipation.
370ES-45 Triggering Advance Time (ΔT) -45µs, Protection Radius (meters) as per Highest Risk 61 Mtr.
371Supply, fabrication, and installation of a galvanized iron (GI) pipe support structure ( Lightning Mast ) with a 350 mm × 350 mm base plate and 10 mm thickness for secure mounting. The mast shall support the ESE air terminal and include provisions for a guy wire clamping system to ensure stability. It shall provide a secure arrangement for fixing the air terminal and have appropriate termination point / arrangement for connection to the downconductor.
372Total Mast height : 5-7.5 meter Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56244695
AUTHORITY Government Departments
TENDER VALUE 3.10 Crore
LAST DATE 22-07-2026
Authority
Authority Name Rajasthan Police Housing & Construction Corporation Limited
Work Description Tender for Construction Of Police Thana Sadar Bazar At Jodhpur Commissionerate Based On Pwd Integrated Bsr 2022 And Electrical Bsr 2022 Rajasthan
Basic Detail
Tender No RPIDCL/NIT-10/2026-27/D-1835 Dt. 29.06.2026
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 01 Jul 2026
Submission Date 22 Jul 2026
Open Date 23 Jul 2026
Finance
Tender Value 3.10 Crore
Tender Fee 5900
EMD 6.20 Lakhs
Exemption Available
Document List
bc535373-0fd3-4d8d-9f12-ad7ca95d804b.html
BOQ_1017710.xls
merged.pdf
TechnicalEvalutionsheet.rar
Tendernotice_1 (27).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

bc535373-0fd3-4d8d-9f12-ad7ca95d804b.html

xls

BOQ_1017710.xls

pdf

merged.pdf

rar

TechnicalEvalutionsheet.rar

pdf

Tendernotice_1 (27).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders