Power Government Departments Closing in 18 days TDR #56243053

Tender For annual rate contract Of Periodical Repair Jobs For Thermal Insulation Work Pertaining To Boiler, Turbine And Its Auxiliaries Of 2X600mw Unit-I And Ii, Rgtpp, Hpgcl, Khedar, Hisar For A Period Of Two Years.

Issued by Government Departments · Hisar, Haryana
Tender Value
69.66 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
18 days left
EMD
1.64 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for annual rate contract Of Periodical Repair Jobs For Thermal Insulation Work Pertaining To Boiler, Turbine And Its Auxiliaries Of 2X600mw Unit-I And Ii, Rgtpp, Hpgcl, Khedar, Hisar For A Period Of Two Years.

BOQ

Name of Work:- ARC of periodical repair jobs for Thermal insulation work pertaining to Boiler, Turbine and its Auxiliaries of 2X600MW Unit-I and II, RGTPP, HPGCL, Khedar, Hisar for a period of two years.
Sl. No. Item Description
1Thermal Insulation works pertaining to Boiler and its auxiliaries
2Providing new Insulation with refixing of old cladding in Boiler Furnace Area. Insulation (Type: Rock Wool Felt, Thickness-200mm) Netting: GI, Cladding (Old Corrugated sheet)
3Providing new Insulation with new cladding in Boiler Furnace Area. Insulation (Type: Rock Wool Felt, Thickness-200mm) Netting: GI, Cladding (Corrugated Al. Sheet, Thickness: 1.2 mm)
4Providing New Insulation with refixing of old cladding in Boiler Furnace Wind Box and APH Area. Insulation (Type: Rock Wool Felt, Thickness-200mm) Netting: GI, Cladding (Old Corrugated sheet)
5Providing New Insulation with New Cladding in Boiler Furnace Wind Box and APH Area. Insulation (Type: Rock Wool Felt, Thickness-190 mm) Netting: GI, Cladding (Corrugated Al. Sheet, Thickness: 1.2 mm)
6Providing New Insulation with refixing of old cladding in Drum DownComers pipers 24 to 80 m elevation, ring header including man holes of ring header at 9 meter elevation, main steam to PRDS line, main steam line and ID fan area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Old plain sheet)
7Providing New Insulation with new cladding in Drum Down-Comers pipers 24 to 80 m elevation, ring header including man holes of ring header at 9 meter elevation, main steam to PRDS line, main steam line and ID fan area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Al. Sheet, Thickness: 0.56 mm)
8Providing New Insulation with refixing of old Cladding in Bottom of Zpanel at 9 meter elevation and ESP Hopper area. Insulation (Type: Rock Wool Felt, Thickness-150 mm) Netting: GI, Cladding (Old Corrugated sheet)
9Providing New Insulation with new cladding in Bottom of Z-panel at 9 meter elevation and ESP Hopper area. Insulation (Type: Rock Wool Felt, Thickness-190 mm) Netting: GI, Cladding (Corrugated Al. Sheet, Thickness: 1.2 mm)
10Providing New Insulation with new cladding in Fuel Oil Lines/after Vent/Drain line valve i.e. Drum Vent, CBD Drain (Left and Right) and Vent, LTSH Drain line and Ring Header Drain Valve area. Insulation (Type: Rock Wool Felt, Thickness-50 mm) Netting: GI, Cladding (Al. Sheet, Thickness: 0.56 mm)
11Filling Inside Cover Plates. Providing only new Insulation in Burner Panel area. Insulation (Type: Rock Wool Felt, Thickness-120 mm) Netting: GI.
12Providing New Insulation with New Cladding in Vent/Drain i.e. Drum Vent, CBD Drain (Left and Right), SH Spray Line and Vent, LTSH Drain line and Ring Header Drain Valve area. Insulation (Type: Rock Wool Felt, Thickness-100 mm) Netting: GI. Cladding (Al. Sheet, Thickness: 0.56 mm)
13Providing New Insulation with New Cladding in Primary and secondary Hot Air Duct at, 6 M to 30 M elevation area. Insulation (Type: Rock Wool Felt, Thickness-170 mm) Netting: GI. Cladding (Corrugated Al. Sheet Thickness: 1.2 mm)
14Providing New Insulation with refixing of old cladding in Primary and secondary Hot Air Duct at , 6 M to 30 M elevation area. Insulation (Type: Rock Wool Felt, Thickness-170 mm) Netting: GI. Cladding (Old Corrugated Sheet)
15Providing New Insulation with New Cladding in Flue Gas Duct area. Insulation (Type: Rock Wool Felt, Thickness-40 mm) Netting: GI. Cladding (Corrugated Al. Sheet Thickness-1.2 mm )
16Providing New Insulation with refixing of old cladding in Flue Gas Duct area. Insulation (Type: Rock Wool Felt, Thickness-40 mm) Netting: GI. Cladding (Old Corrugated Sheet)
17Providing New Cladding sheet on existing insulation in any area boiler/ hot duct/cold duct/wind box/ ESP hopper /ESP duct. Cladding (Corrugated Sheet Al Thickness: 1.2 mm)
18Providing New Cladding sheet on existing insulation in Any area line of vent/drain/main steam line/ bottom Ring Header line. Cladding (Al. Sheet Thickness: 0.56 mm)
19Refixing of Old cladding Sheet in any of the area pertaining to Boiler and its auxiliaries. Cladding (Old Corrugated/ plain sheet)
20Thermal Insulation works pertaining to Turbine and its auxiliaries
21Alumina silicate Felt with refractory plaster, Thickness:200 mm
22Alumina silicate Felt with refractory plaster, Thickness:160 mm
23refractory plaster, Thickness:20 mm
24Alumina silicate Felt, Insulation Thickness-200 mm ,Al sheet Thickness:0.71 mm
25Alumina silicate Felt, Insulation Thickness-150 mm ,Al sheet Thickness:0.71 mm
26Alumina silicate Felt ,Thickness 120 mm ,Al sheet Thickness:0.71 mm
27Alumina silicate Felt ,Thickness 100 mm ,Al sheet Thickness:0.71 mm
28Alumina silicate Felt ,Thickness 80mm ,Al sheet Thickness:0.71 mm
29Alumina silicate Felt ,Thickness 50 mm ,Al sheet Thickness:0.71 mm
30Rock Wool felt ,Insulation Thickness 160 mm,Al sheet Thickness:0.71 mm
31Rock Wool felt ,Insulation Thickness120 mm ,Al sheet Thickness:0.71 mm
32Rock Wool felt,Insulation Thickness 100 mm,Al sheet Thickness:0.71 mm
33Rock Wool felt ,Insulation Thickness 80 mm ,Al sheet Thickness:0.71 mm
34Rock Wool felt , Insulation Thickness 50 mm ,Al sheet Thickness:0.71 mm
35Cladding Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56243053
AUTHORITY Government Departments
TENDER VALUE 69.66 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Haryana Power Generation Corporation Limited
Work Description Tender for annual rate contract Of Periodical Repair Jobs For Thermal Insulation Work Pertaining To Boiler, Turbine And Its Auxiliaries Of 2X600mw Unit-I And Ii, Rgtpp, Hpgcl, Khedar, Hisar For A Period Of Two Years.
Basic Detail
Tender No 2026DD06E86B 8E10 44D5 8A26 62C5304E56B3712PGC
Bidding Type Tender
Location
City Hisar
State Haryana
Key Dates
Publish Date 01 Jul 2026
Submission Date 21 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 69.66 Lakhs
Tender Fee 1180
EMD 1.64 Lakhs
Exemption Available
Document List
BOQ_611838.xls
cbc112b0-eccb-40a9-9780-95f23a0c752b.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_611838.xls

html

cbc112b0-eccb-40a9-9780-95f23a0c752b.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders