Banking and Finance Government Departments Closing in 1 days TDR #56243012

Tender For Design, Engineering, Supply, Erection, Installation, Testing And Commissioning Of Calibration Wind Tunnel Facility At Mohasa-Babai Ndustrial Area, District- Narmadapuram, Madhya Pradesh

Issued by Government Departments · Hoshangabad, Madhya Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Jul 2026
1 days left
EMD
10 Lakhs
Bank guarantee accepted
Document Fee
35400
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshangabad → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Design, Engineering, Supply, Erection, Installation, Testing And Commissioning Of Calibration Wind Tunnel Facility At Mohasa-Babai Ndustrial Area, District- Narmadapuram, Madhya Pradesh

BOQ

Name of Work:- DESIGN, ENGINEERING, SUPPLY, ERECTION, INSTALLATION, TESTING AND COMMISSIONING OF CALIBRATION WIND TUNNEL FACILITY AT MOHASA-BABAI NDUSTRIAL AREA, DISTRICT- NARMADAPURAM, MADHYA PRADESH
Sl. No. Item Description
1A -Design, Engineering and Project Management
2Detailed aerodynamic, mechanical, electrical, control, civil, and structural design of the closed-return calibration wind tunnel, including CFD analyses, flow-conditioning design, diffuser design, vibration and structural analysis
3Preparation of complete construction documents: civil, structural, architectural, electrical SLDs, HVAC drawings, P&IDs, control logic flow charts, layout plans
4Project management, design coordination, QA/QC plan, documentation control, Testing & Inspection Plans (TIP), progress reporting up to completion of SAT
5B- Wind Tunnel Main System
6Closed-return wind tunnel structure (ducts, corners, support frames, access doors); internal duct surface finish and aerodynamic smoothness as specified (including maximum surface roughness requirement where applicable)
7Test section assembly: minimum two modular cells (>= 1.00 m x 1.00 m; total enclosed length >= 4.0 m) with access provisions and mounting systems; windows only if required by design and compliant with flow-quality requirements
8Contraction unit with contraction ratio >= 6:1 (preferred >= 8:1), including fairings and structural supports
9Flow-conditioning system: honeycombs (L/D >= 7), screens (4–6), supports and alignment fixtures
10Diffuser system with anti-separation aerodynamic design, engineered for static pressure recovery coefficient Cp ≥ 0.65 (as defined and substantiated in the approved technical submission), including transition sections, expansion geometry, and associated turning elements as required by the tunnel circuit.
11Axial fan and motor system with inlet/outlet silencers and integrated acoustic treatment to achieve equipment-level noise requirement as specified (<= 85 dB(A) at 1 m at maximum operating condition)
12Vibration isolation system for tunnel, fan and rotating equipment (springs/isolators/dampers) as per vibration criteria specified
13C- Flow Measurement, Instrumentation and DAS/DAQ
14Primary flow measurement system (Pitot-static probes, differential pressure measurement chain, manifolds/tubing)
15Low-speed reference system (thermal anemometer or equivalent reference system) for low-speed calibration range as specified
16Optional laser-based system (LDA/PDA), if offered and accepted by MPIDC/NIWE as an optional enhancement; to be quoted as a separate optional line item
17Reference pressure sensors (absolute and differential) and associated hardware meeting specified accuracies and uncertainty requirements
18Reference temperature and humidity sensors (test section and ambient) meeting specified accuracies and stability requirements
19Additional reference instrumentation (barometric pressure sensor, probes, accessories) required to achieve declared CMC and uncertainty budget
20ISO/IEC 17025 accredited calibration of all reference instruments (certificates included in handover dossier)
21DAQ hardware: signal conditioning modules, networking components, data servers/storage, UPS interface
22DAS and control software: licences, real-time monitoring, automated sequences, reporting tools, access control and audit logging
23Control system hardware (PLC, HMI, safety relays, control panels, wiring and I/O)
24Integration, configuration, and commissioning of flow reference instrumentation, signal conditioning, DAS/DAQ, control system, and associated wiring/EMI mitigation; including demonstration through a documented uncertainty analysis that the combined contribution of the reference measurement chain (k = 2) complies with the limits specified in the Technical Specifications (i.e., ≤ ±0.005 m/s for 0.5–1.0 m/s and ≤ ±0.5% of reading above 1.0 m/s).
25D- Mechanical, Electrical, HVAC and Tunnel Building Services
26Foundation and inertia blocks for tunnel and rotating equipment (excavation, RCC, anchoring)
27Superstructure and building works (tunnel hall, control room, service rooms, support spaces, doors/windows, finishes) as per approved Master Layout and IFC drawings
28Electrical system up to the Utility Interface Point and within facility: incoming supply interface, MSB/DBs, cabling, earthing, lightning/surge protection, lighting and power outlets
29UPS system (minimum 30 minutes autonomy) for critical loads: DAS, PLC/HMI, reference instruments, networking and safety circuits, as specified
30Provision and interface for standby generator including ATS and essential load panel (excluding DG set supply if quoted separately)
31HVAC system (PAHU/AHUs, chillers/condensing units, pumps, ducts, diffusers, controls, vibration isolation) supporting building-level ambient control and coordination with tunnel internal environmental control
32Air-filtration system (multi-stage; final stage ISO 16890 ePM1 >= 80% or equivalent) with maintenance access provisions
33Building and internal acoustic treatment to achieve: (i) equipment-level noise compliance; and (ii) control room Leq <= 65 dB(A) during representative high-speed operation, as specified
34Fire detection and suppression systems, alarms, safety signage and emergency exits as per NBC India and applicable standards; clean agent protection where required for electronics
35Diesel generator set (DG) sized at >= 125% (recommended) of declared essential load (kVA to be proposed by bidder), including AMF/ATS panel and integration with UPS and control systems, where DG supply is within bidder scope
36E- Calibration, Commissioning, SAT and Documentation
37Factory Acceptance Tests (FAT) for tunnel subsystems, fan, DAQ/DAS, instrumentation and safety interlocks; FAT reports
38Transport, unloading, on-site installation and alignment of tunnel and systems
39Site Acceptance Tests (SAT): flow-quality verification, CMC validation, Cp verification (where applicable), noise tests and environmental stability verification as per approved SAT protocol
40SAT protocol submission, SAT report submission; rectification and re-testing until compliance with mandatory requirements
41As-built drawings (civil, structural, electrical/HVAC/services, tunnel), editable CADs and control/DAS configurations
42Operation and Maintenance Manuals (tunnel, HVAC, electrical, DAS, instrumentation), preventive maintenance schedules and spares list
43F- Training and Accreditation Support
44On-site training for NIWE staff on tunnel operation, safety, DAS/control use and routine maintenance
45Technical training on anemometer and wind-vane calibration, data analysis and uncertainty evaluation
46Accreditation support package aligned to ISO/IEC 17025 and applicable technical standards (IEC 61400-12-1, IEC 61400-50-1, MEASNET procedure, IECRE ODs): documentation templates, uncertainty budgets, internal audit/gap analysis support
47NABL/MEASNET/IECRE support roadmap: evidence-generation plan, mock audits support and CMC documentation package (recognition/assessment timelines external to bidder; bidder support obligations as per tender)
48G- Spares, Tools and Accessories
49Recommended spare parts for first 5 years (fan components, sensors, DAQ modules, filters, etc.) as per bidder recommended stock levels and criticality
50Special tools/test equipment required for periodic maintenance and intermediate calibration checks
51H- Warranty Phase Support
52Comprehensive support during 60-month warranty (preventive visits and breakdown response as per tender)
53Resident engineer/technical specialist support for 60 months after commissioning/SAT (where required by tender)
54I- Defect Liability Period (DLP)
55DLP Period – Year 1 (as per accepted DLP proposal)
56DLP Period – Year 2 (as per accepted DLP proposal)
57DLP Period – Year 3 (as per accepted DLP proposal)
58DLP Period – Year 4 (as per accepted DLP proposal)
59DLP Period – Year 5 (as per accepted DLP proposal) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56243012
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 13-07-2026
Authority
Authority Name Madhya Pradesh State Industrial Development Corporation Ltd
Work Description Tender for Design, Engineering, Supply, Erection, Installation, Testing And Commissioning Of Calibration Wind Tunnel Facility At Mohasa-Babai Ndustrial Area, District- Narmadapuram, Madhya Pradesh
Basic Detail
Tender No MPIDC/Tech-RFP/CE/2026/257
Bidding Type Tender
Location
City Hoshangabad
State Madhya Pradesh
Key Dates
Publish Date 01 Jul 2026
Submission Date 13 Jul 2026
Open Date 14 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 35400
EMD 10 Lakhs
Exemption Not Available
Document List
137ef363-0427-4ce0-b6ee-0a171bb2cbc5.html
BOQ_624542.xls
C03NIT257.pdf
C07NIT257.pdf
C10NIT257.pdf
EOIPublish.pdf
RFPNIT257.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

137ef363-0427-4ce0-b6ee-0a171bb2cbc5.html

xls

BOQ_624542.xls

pdf

C03NIT257.pdf

pdf

C07NIT257.pdf

pdf

C10NIT257.pdf

pdf

EOIPublish.pdf

pdf

RFPNIT257.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders