Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #56241640

Tender For maintenance of Various Shopping Centre In Trans Yamuna Area. Sh: Running Maintenance & Operation Of Fire Fighting System, Fire Alarm System, Clear Water Pump Set, Sub P/Set, electrical installation & Fans At Dda Building Laxmi Nagar Dist.

Issued by Local Bodies · Delhi, Delhi
Tender Value
27.77 Lakhs
Estimated cost
Bid Submission
08 Jul 2026
6 days left
EMD
55558
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance of Various Shopping Centre In Trans Yamuna Area. Sh: Running Maintenance & Operation Of Fire Fighting System, Fire Alarm System, Clear Water Pump Set, Sub P/Set, electrical installation & Fans At Dda Building Laxmi Nagar Dist. Centre.

BOQ

Name of Work:- M/o various shopping centre in trans Yamuna Area. SH: Running Maintenance & Operation of fire fighting system, fire alarm system, clear water pump set, sub p/set, EI & Fans at DDA building Laxmi Nagar Dist. Centre.
Sl. No. Item Description
11.0) Running, maintenance & operation of various E&M services at DDA building Laxmi Nagar Distt. Centre. By deploying following manpower:- (i) Operator Gr.II cum technician round the clock -3 Nos. on daily basis.(ii) Lift Operator Gr. II -2 Nos.on daily basis.(iii) Khallasi 1 No.on daily basis.
22.0) Servicing of DG Set 160 KVA (kirloskar make) including labour charges for complete servicing and testing i/c commissioning etc complete as reqd replacement/ repair/calibration of following, Diesel and oil filter, Air cleaner electrical, Coolant, Hose pipe set with clamp, Engine self repairing and servicing i/c replacement of part, Fuel pump repair and calibration, Engine oil.
33.0) LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 3.01) 18- 22 Watt
44.0) Supply and replacement of fan regulator switch in the existing electric board i/c connection, testing etc. as required.
55.0) Supply and replacement of cooler pump 230 Volt, AC supply having 12.0 watt consumption with maximum water filled with lift 1.5 mtr. Immersion depth 200 mm connection, testing etc. as required.
66.0) Supply & replacement of desert coolers pads of wool with mesh wire (3 Nos.) suitable for 18\\"/20\\" desert cooler i/c removal of old, cleaning of dust after removing cooler from the window and reinstallation of the same at window etc. Complete as required.6.1) Wood wool pad with wire mesh.- 3 Nos.
77.0) Supply & replacement of cooler kit (Fan size 18\\"/20\\" i/c blade, motor) connection, testing, and commissioning etc. as reqd.
88.0) Supplying and replacement round copper cable lead of size 40/76 mm three core of 3 Mtrs. long i/c providing/ fixing 3 pin 15 Amp top plug etc. complete as required.
99.0) Rewinding of 48\\" ceiling fan oiling, greasing servicing, cleaning dismantling and re- assembling along with testing, commissioning etc. as required.
1010.0) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required..
1110.1) 5/6 amps switch
1210.2) 3 pin 5/6 A socket outlet
1310.3) 15/16 A switch
1410.4) 6 pin 15/16 A socket outlet
1511.0) Repairing & rewinding of following rating submersible pump set (Motor & Pump) i/c remettling of impeller, bush, neck ring etc. complete as reqd.11.1) 3 HP
1612.0) Supply & replacement of following parts in existing electrical panel.
1712.1) DOL Starter (make- L&T or similar )
1812.2) FASD ML 1.5 motor Starter (make- L&T or similar superior)
1912.3) 3 Pole 25 Amp. Contactor (make- L&T or similar)
2012.4) Overload Relay suitable for ML 1.5 starter (make- L&T or similar )
2112.5) Digital A. Meter, V. Meter of suitable range (L&T make, class 1 or similar)
2212.6) Single phase preventer (L&T Make or similar)
2313.0) Supplying & replacement of following sizes of XLPE aluminium conductor armoured Power cable 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed.
2413.1) 3C x 16 sq. mm.
2513.2) 4C x 25 sq. mm.
2614.0) Performing of following job for repairing 7.5 HP mono block pump set assembly (clear water)i/c dismantling ,re-assembling and testing etc. complete as reqd.
2714.1) Rewinding of Motor
2814.2) S/R of Ball bearing
2914.3) S/R of Gland Sleeve
3014.4) S/R of Neck ring
3114.5) Labour charges for servicing i/c cartage and assembling of pump set in suction line
3215.0) Performing of following job for repairing of 7.5 HP Veda pump set assembly (dewatering ) i/c dismantling ,re-assembling and testing etc. complete as reqd.
3315.1) Rewinding of Motor
3415.2) S/R of Ball bearing No. 3306
3515.3) S/R of Ball bearing No. 6234
3615.4) S/R of Mechanical seal
3715.5) S/R of Oil 1 Ltr.
3815.6) Rubber seals
3915.7) Labour charges for servicing i/c cartage and assembling of pump set in suction line
4016.0) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. .
4116.1) Single pole
4216.2) Double pole
4316.3) Triple pole and neutral
4417.0) Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required.
4517.1) 40 A
4617.2) 60 A
4718.0) Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
4818.1) 1 x 1.5 sq. mm
4918.2) 3 x 1.5 sq. Mm
5018.3) 3 x 2.5 sq. mm
5118.4) 3 x 4 sq. mm.
5219.0) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
5319.1) 25mm
5419.2) 20 mm
5520.0) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
5621.0) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 21.01) Group C
5722.0) Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning (including deduction of cost for replaced item) of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
5823.0) Replacement & installation of exhaust fan (metallic body) of size 12\\" i/c connections,making good the damages ,iron angle & painting with screws,nuts & bolts etc. complete as required.
5924.0) Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. As required.
6024.1) 1 or 2 Module
6124.2) 3 Module
6224.3) 4 Module
6324.4) 6 Module
6424.5) 8 Module
6524.6) 12 Module
6625.0) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. As required.
6725.1) 5/6 A switch
6825.2) 15/16 A switch
6925.3) 3 pin 5/6 A socket outlet
7025.4) 6 pin 15/16 A socket outlet Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56241640
AUTHORITY Local Bodies
TENDER VALUE 27.77 Lakhs
LAST DATE 08-07-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Various Shopping Centre In Trans Yamuna Area. Sh: Running Maintenance & Operation Of Fire Fighting System, Fire Alarm System, Clear Water Pump Set, Sub P/Set, electrical installation & Fans At Dda Building Laxmi Nagar Dist. Centre.
Basic Detail
Tender No 15/EE/ELD-1/DDA/NIT/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 30 Jun 2026
Submission Date 08 Jul 2026
Open Date 09 Jul 2026
Finance
Tender Value 27.77 Lakhs
Tender Fee Ref. Documents
EMD 55558
Exemption Not Available
Document List
2778e67c-d861-4354-b9c2-ebf6b7db368b.html
BOQ_961762.xls
Tenderdocument15ELD01.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

2778e67c-d861-4354-b9c2-ebf6b7db368b.html

xls

BOQ_961762.xls

pdf

Tenderdocument15ELD01.pdf

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders