Tender For Supply Installation Testing and Commissioning of 06 Nos Split Type Air Conditioners, Repair And Maintenance Of Existing Ug Cable Of Sand Model (Being Used As A Conference Hall) At Adm Of Shq Bsf Indreshwar Nagar.
Tender Value
5.99 Lakhs
Estimated cost
Bid Submission
07 Jul 2026
2 days left
EMD
11990
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of 06 Nos Split Type Air Conditioners, Repair And Maintenance Of Existing Ug Cable Of Sand Model (Being Used As A Conference Hall) At Adm Of Shq Bsf Indreshwar Nagar.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). (i) 2 TR with 5 star BEE rating, Inverter type- Cooling only. |
| 2 | Supplying and drawing 3 x 4 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 3 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (i) 6 pin 15/16 A socket outlet. |
| 4 | Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modular switches in recess etc. as required (i) 1 or 2 Module (75mmX75mm). |
| 5 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (i) 3.5 X 185 sq. mm (57 mm). |
| 6 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. (i) 300 mm dia |
| 7 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. (i) 250, 50KA, FPMCCB |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (i) Above 95 sq. mm and upto 185 sq. mm. |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (i) Above 95 sq. mm and upto 185 sq. mm. |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (i) Above 95 sq. mm and upto 185 sq. mm. |
| 11 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 12 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3½ X 35 sq. mm |
| 13 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3½ X 70 sq. mm |
| 14 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3½ X 185 sq. mm |
| 15 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3½ X 240 sq. mm |
| 16 | Supplying and fixing of 25 x 12 mm sizes of PVC casing caping in surface etc as required. |
| 17 | Supplying and fixing 5 KVA stablizer having following technical specification, copper winding, input voltage - 90 volt to 300 volt, digital display meter etc as required. (make V-guard/ Luminous/ Mircotek. |
| 18 | Supplying and fixing 4 way 200 Amp aluminium bus bar distribution board complete with connections, testing and commissioning etc. as required. |
| 19 | SITC of dust & vermin proof outdoor type compartmentalized floor mounted feeder pillar/ joint box of size not less then 450 mm (Height) x 450 mm (width) x 300 mm (deep) suitable for 415 volt 3 phase 50 Hz A.C supply, fabricated out of 2 mm thick CRCA sheet steel, tapered roof, front and rear openable, both side locking arrangement, 3 mm thick gland plate, 200 Amps four pole Aluminium bus bar with base, connection and interconnection with copper conductor/ PVC insulated cable / insulated Aluminium bus bar strip of appropriate size terminal block etc, to be fitted on base frame made out of 50 mm x 50 mm x 5 mm (thick) GI angle having 80 cm legs for erection on ground etc as required. The feeder pillar shall be erected in cement concrete foundation of size 450 mm x 300 mm (width) x 700 mm height embedded 400 mm below ground level and 300 mm above ground level and angle lugs to be grouted in the cement concrete foundation etc complete as required. (CPRI approved). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender