Tender For special repair To electrical installation In Administrative Building Ground Floor, Sanskaar Mandap And Patch Repair Of Different Small Mandir, Baba Mandir, Parvati Mandir, Different Shed Jalarpan Counter And Root Line Of Surrounding Shiv G
Tender Overview
Project Description
Tender for special repair To electrical installation In Administrative Building Ground Floor, Sanskaar Mandap And Patch Repair Of Different Small Mandir, Baba Mandir, Parvati Mandir, Different Shed Jalarpan Counter And Root Line Of Surrounding Shiv Ganga At Baba Basukinath Mandir Basukinath, Dumka.
BOQ
| Sl. No. | Item Description |
| 1 | Part - AS/R to E.I. in Administrative building of ground Floor in Basukinath Mandir. |
| 2 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required. |
| 3 | a) Group - C |
| 4 | Wiring for light/ power plug with 2x4 sq mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 no 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as reqd. |
| 5 | Wiring for circuit submain wiring along with earth wire with the following size PVC insulated copper conductor , single core cable in surface / recessed PVC conduit etc as reqd . |
| 6 | a) 2x2.5 sq mm + 1x2.5 sq mm Earth wire (For light circuit.) |
| 7 | b) 2x1.5 sq mm + 1x.5 sq mm (For double socket Board wiring) |
| 8 | c) 2x4.0 sq mm + 1x4.0 sq mm (For light Submain.) |
| 9 | d) 2x6.0 sq mm + 1x6.0 sq mm (For Power Submain.) |
| 10 | e) 1x1.5 sq, mm. (For Inverter wiring.) |
| 11 | S/F a compact unit made of 6 Module G.I./PVC box with 6 Modular cover plate in front of fixed with 2 Nos of 5/6 amps 3 pin modular type socket, 2 No. 5/6 amp modular type one way switch, well connected with suitable wire , earthing etc as reqd. |
| 12 | a) 6 Mod box with plate - 1 Nos @ 240.00 = 240.00 |
| 13 | b) 5/6 Amp switches - 2 Nos @ 67.00 = 134.00 |
| 14 | c) 5/6 Amp 3 Pin socket -2 Nos @ 88.00 = 176.00 |
| 15 | Total = 550.00 |
| 16 | Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings. |
| 17 | Supplying and fixing suitable GI box with modular plac and cover in front on surface of in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 5/6 amps modular switch. connection, painting etc. as required (For light plugs to be used in non residential buildings. |
| 18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) |
| 19 | a) 2 way single door |
| 20 | b) 4 way double door |
| 21 | c) 6 way double door |
| 22 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “B” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. |
| 23 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. |
| 24 | a) 32 amp D.P. MCB |
| 25 | b) 63 amp D.P. MCB |
| 26 | S/F stepped type electronic fan regulator on the existing modular plate & switch box including connection but excluding modular plate etc as reqd. |
| 27 | S/F Modular blanking plate on the existing modular plate & switch box excluding modular plate as reqd. |
| 28 | S/F 2 pin 5 Amp Ceiling rose on the existing junction box etc as reqd. |
| 29 | Supplying and fixing batten/ angle holder including connections etc as reqd. |
| 30 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 31 | a) 20/22W LED Tube light |
| 32 | S/F 9/10 watt LED bulb |
| 33 | S.I.T.C. of following size ceilling fan 3 blades confirming to IS:374:2019 including wiring the down roadsof suitable length (up to 30cm) with 1.5 sq. mm. PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as reqd. |
| 34 | a) 1200 mm (48'') ceiling fan |
| 35 | Part - BS/R to E.I. in sanskaar Mandap In Basukinath Mandir. |
| 36 | Supplying and drawing following size of FR PVC insulated copper conductor single core cable in existing Surface / recessed Steel / PVC conduit in cluding ddismantailing as reqd. |
| 37 | a) 2x1.5 sq mm (Loop For light point and Fan Point) |
| 38 | b) 2x2.5 sq mm (circuit For Light & Fan) |
| 39 | Supplying and fixing of followingf size of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as reqd. |
| 40 | a) 25 mm PVC Conduit |
| 41 | S/F 4 x 10 sq. mm + 2 X 6 Sq. mm Earth wire (from Busbar to 2 No. main Control Panel for submain wiring.) |
| 42 | Supplying and fixing batten/ angle holder including connections etc as reqd. |
| 43 | S/F 2 pin 5 Amp Ceiling rose on the existing junction box etc as reqd. |
| 44 | Supplying and fixing of following size of PVC / G.I box on Surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc as reqd. |
| 45 | a) 75mm x 75mm x 50mm deep/ (4''x4'') For light & Fan Point |
| 46 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 47 | a) 20/22W LED Tube light |
| 48 | S/F 15/16 watt LED bulb |
| 49 | S/F Bulk head fitting with 9/10 Watt LED Lamp etc as reqd. |
| 50 | S.I.T.C. of following size ceilling fan 3 blades confirming to IS:374:2019 including wiring the down roadsof suitable length (up to 30cm) with 1.5 sq. mm. PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as reqd. |
| 51 | a) 1200 mm (48'') ceiling fan |
| 52 | Fabrication and installation of wall mounted double door, IP 66 Protection cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade including fitting/ fixing/ connection & transportation up to work site, labour charge etc all complete.25 - 100 Amp, 10 KA, 4 pole MCCB (Incoming) = 1 Nos.6 To 32 Amp, Single Pole MCB = 24 Nos.4.0 sq. mm ISI Marked, FRLS PVC Insulated, single core copper conductor cable. = 18 Mtr.4 sq. mm copper lugs = 24 Nos.LED Indecator lam R/Y/B/G = 3 Nos.25mm x 5mm copper strips (1.15 kg/mtr) = 12 Kg |
| 53 | Part - CPatch Repair of E.I. in different Small Mandir, Baba Mandir, Parvati mandir,Kali Mandir Q - Shed Root line of surrounding Shiv Ganga in Baba Basukinath Dham at Basukinath, Dumka. |
| 54 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required. |
| 55 | a) Group - C |
| 56 | Supplying and drawing following size of FR PVC insulated copper conductor single core cable in existing surface / recessed steel / PVC conduit including dismantling as reqd. |
| 57 | a) 2 x 1.5 sq, mm. (Repairing For Light Point wiring) |
| 58 | b) 3 x 1.5 sq, mm. (wiring For Street light, Flood light and Highway light.) |
| 59 | c) 3x2.5 sq, mm. (Repairing For Light Circuit) |
| 60 | d) 3 x 4 sq, mm. (Repairing For Power circuit and Submain.) |
| 61 | Supplying and fixing of following size of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as reqd. |
| 62 | a) 20 mm PVC Conduit |
| 63 | b) 25 mm PVC Conduit |
| 64 | Supplying and fixing of following piano type switch / Socket on the existing switch box / cover including connections etc as reqd. |
| 65 | a) 5/6 Amp, one way switch |
| 66 | b) 3 pin 5/6 amps, socket outlet |
| 67 | c) 15/16 Amp, 6 Pin S.S Combined |
| 68 | d) Electronic step fan regulator, mini |
| 69 | Supplying and fixing of following size of PVC / G.I. box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc as reqd. |
| 70 | a) 75mm x 75mm x 50mm deep / (4''x4'') |
| 71 | b) 72mm x 146mm x 48mm deep / (4''x7'') |
| 72 | c) 121mm x 173mm x 48mm deep / (6''x8'') |
| 73 | Supplying and fixing of following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd. |
| 74 | a) 5/6 Amp, one way switch. |
| 75 | b) 15/16 Amp, one way switch. |
| 76 | C) 5/6 Amp, 3 pin socket outlet |
| 77 | Supplying and fixing 2 pin 5 amp, Ceiling rose on the existing junction box / wooden block including connection etc as reqd. |
| 78 | Supplying and fixing Batten / Angle Holder including connection etc as reqd. |
| 79 | Supplying and fixing of Pendant holder. (For Emergency LED Inverter Bulb.) |
| 80 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “B” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. |
| 81 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. |
| 82 | a) 6 to 32 amp D.P. MCB |
| 83 | b) 63 amp D.P. MCB |
| 84 | c) 50/63 amp TPN MCB |
| 85 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB Complete with connections, testing and commissioning etc as reqd. |
| 86 | a) 16/25 amps |
| 87 | b) 40 amps |
| 88 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB Complete with connections, testing and commissioning etc as reqd. |
| 89 | a) 40 Amps |
| 90 | b) 63 Amps |
| 91 | S.I.T.C of floowing rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. |
| 92 | a) 20/22W LED Tube light |
| 93 | S/F 15/16 watt LED bulb |
| 94 | S.I.T.C. of following size ceilling fan 3 blades confirming to IS:374:2019 including wiring the down roadsof suitable length (up to 30cm) with 1.5 sq. mm. PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as reqd. |
| 95 | a) 1200 mm (48'') ceiling fan |
| 96 | S/F 12'' (300mm) metal exaust fan / Cabin Fan |
| 97 | S/F 450 mm (18'') metal body wall fan with speed regulator suitable for single phase 220V, 50Hz AC Supply |
| 98 | Supplying and fixing Turbo force wall Air circulator (24'' 600 mm) industrial type wall fan etc as reqd. |
| 99 | S.I.T.C of following ratting recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS : 10322 part - 5 / section - 2 or IEC : 62722 with all neccssary accessories as reqd. |
| 100 | a) 15/16W LED Round down light |
| 101 | b) 18/20W LED Round down light |
| 102 | c) 15/16W LED Square Down light |
| 103 | d) 3w COB based round LED light with multiple beam angles (36 degree) |
| 104 | S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required |
| 105 | a) 90w L.E.D. Campus light. |
| 106 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required |
| 107 | a) 50/60 watt LED Flood light |
| 108 | b) 90/100 Watt LED Flood light |
| 109 | c) 200 watt LED Flood light |
| 110 | Supplying and laying of XLPE insulated PVC sheathed aluminium armoured cable working voltage upto 1100 volts as per IS: 7098 (Part I) of following sizes. |
| 111 | a) 4 core 10 sq mm |
| 112 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as reqd. Up to 35 sq. mm, Clamped with 1mm thik G.I. Saddle) |
| 113 | Supplying and fixing cable junction box with 1 no. single pole MCB suitable for inductive load. make:- Sintex / Hensel or equivelant. |
| 114 | 6 way, Double door MCB |
| 115 | 2 way, Single door MCB |
| 116 | CGST@9% |
| 117 | CGST@9% |
| 118 | Add Labour Cess@1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender