Tender For Turnkey Construction Of One No. Of 33Kv Feeder Bay And Associated Works At 220/132Kv Rangia Gss, Aegcl For Tamulpur Medical College
Tender Value
1.11 Crore
Estimated cost
Bid Submission
22 Jul 2026
18 days left
EMD
2.25 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Turnkey Construction Of One No. Of 33Kv Feeder Bay And Associated Works At 220/132Kv Rangia Gss, Aegcl For Tamulpur Medical College
BOQ
| Sl. No. | Item Description |
| 1 | Supply of equipment and accessories |
| 2 | 33 kV , 31.5kA/3sec ,2000A Gang operated Vacuum Circuit Breaker complete with mounting structure and accessories including terminal connectors etc. |
| 3 | 33kV ,25 kA,1250A motorised isolators with single earth switch complete with all fittings and accessories including terminal connectors |
| 4 | 33kV ,25 kA,1250A motorised isolators without earth switch complete with all fittings and accessories including terminal connectors |
| 5 | 33kV, 400/1-1A,2 core single phase CT complete with all fittings and accessories including terminal connectors and marshalling box as required (0.2 Class,live tank type ) |
| 6 | CT Junction Box |
| 7 | 33kV lightning arrester and surge monitor complete with all fitting and accessories including terminal connectors |
| 8 | 33 kV PT (33/√3)/(110/√3) with all terminal connectors (accuracy class 0.2) |
| 9 | 33kV post insulator with all fittings including terminal connectors |
| 10 | Mounting structures with mounting and foundation bolts as per drawing |
| 11 | 33 kV motorised isolators with single earth switch |
| 12 | 33 kV motorised isolators without earth switch |
| 13 | 33 kV CT |
| 14 | 33 kV LA |
| 15 | 34 kV PT |
| 16 | 33 kV PI |
| 17 | SAMAST compliant ABT energy meter including installation |
| 18 | clamps and connectors |
| 19 | ACSR Panther conductor |
| 20 | T Clamps Zebra to Panther |
| 21 | Isolator clamps (Panther) |
| 22 | CT Clamps (Panther) |
| 23 | CB Clamps |
| 24 | BPI Clamps |
| 25 | Earthmat Extension and grounding of equipments |
| 26 | 65 X 12 mm GI flat earthing conductor for earthing of indoor L.T and control pannels, junction box, marshalling boxes , cable trenches etc |
| 27 | 50 X 6 MM GI flat |
| 28 | Earth electrode , 100mm dia , 3m long GI pipe |
| 29 | XLPE control cable (Cu) and power cable (Al) |
| 30 | 4C X 2.5 sq.mm |
| 31 | 7C X 1.5 sq.mm |
| 32 | 12C X 1.5 sq.mm |
| 33 | XLPE power cable (Al) |
| 34 | 2C X 6 sq.mm |
| 35 | 4C X 16 sq.mm |
| 36 | LED flood lights (100W) for switchyard illumination, including fitting and fixing |
| 37 | Supply of AC marshalling Kiosk including construction of foundation , installation and cable foundation . 1) 2 No 63A, 4P (incomer) 2) 3 No 25 A, 4P(outgoing) 3) 8 No 16A, 4P(outgoing) 4) 8No 10A, 4P (outgoing) 5) 5 No 10A,2P (outgoing) |
| 38 | 415V AC Distribution Board (o/g feeder 10 Nos) Outdoor type |
| 39 | Mandatory spares |
| 40 | 33kV ,400/1-1A, 2core single phase CT |
| 41 | Master trip relay |
| 42 | Bay control unit |
| 43 | O/C &E/F relay |
| 44 | 33kV LA |
| 45 | 33kV Vacuum CB |
| 46 | Mandatory spares for 33 kV Isolators |
| 47 | 33kV, 25KA,1250A isolators female/fixed contact |
| 48 | 33kV,25kA,1250A isolator male/moving contact |
| 49 | C&R Panel |
| 50 | 33 kV feeder C&R panel (Simplex type) with BCU, ethernet switch with all accessories suitable for SAS integration with existing SAS (Make:SIEMENS) |
| 51 | Supply of equipment and accessories |
| 52 | 33 kV , 31.5kA/3sec ,2000A Gang operated Vacuum Circuit Breaker complete with mounting structure and accessories including terminal connectors etc. |
| 53 | 33kV ,25 kA,1250A motorised isolators with single earth switch complete with all fittings and accessories including terminal connectors |
| 54 | 33kV ,25 kA,1250A motorised isolators without earth switch complete with all fittings and accessories including terminal connectors |
| 55 | 33kV, 400/1-1A,2 core single phase CT complete with all fittings and accessories including terminal connectors and marshalling box as required (0.2 Class,live tank type ) |
| 56 | CT Junction Box |
| 57 | 33kV lightning arrester and surge monitor complete with all fitting and accessories including terminal connectors |
| 58 | 33 kV PT (33/√3)/(110/√3) with all terminal connectors (accuracy class 0.2) |
| 59 | 33kV post insulator with all fittings including terminal connectors |
| 60 | Mounting structures with mounting and foundation bolts as per drawing |
| 61 | 33 kV motorised isolators with single earth switch |
| 62 | 33 kV motorised isolators without earth switch |
| 63 | 33 kV CT |
| 64 | 33 kV LA |
| 65 | 34 kV PT |
| 66 | 33 kV PI |
| 67 | SAMAST compliant ABT energy meter including installation |
| 68 | clamps and connectors |
| 69 | ACSR Panther conductor |
| 70 | T Clamps Zebra to Panther |
| 71 | Isolator clamps (Panther) |
| 72 | CT Clamps (Panther) |
| 73 | CB Clamps |
| 74 | BPI Clamps |
| 75 | Earthmat Extension and grounding of equipments |
| 76 | 65 X 12 mm GI flat earthing conductor for earthing of indoor L.T and control pannels, junction box, marshalling boxes , cable trenches etc |
| 77 | 50 X 6 MM GI flat |
| 78 | Earth electrode , 100mm dia , 3m long GI pipe |
| 79 | XLPE control cable (Cu) and power cable (Al) |
| 80 | 4C X 2.5 sq.mm |
| 81 | 7C X 1.5 sq.mm |
| 82 | 12C X 1.5 sq.mm |
| 83 | XLPE power cable (Al) |
| 84 | 2C X 6 sq.mm |
| 85 | 4C X 16 sq.mm |
| 86 | LED flood lights (100W) for switchyard illumination, including fitting and fixing |
| 87 | Supply of AC marshalling Kiosk including construction of foundation , installation and cable foundation . 1) 2 No 63A, 4P (incomer) 2) 3 No 25 A, 4P(outgoing) 3) 8 No 16A, 4P(outgoing) 4) 8No 10A, 4P (outgoing) 5) 5 No 10A,2P (outgoing) |
| 88 | 415V AC Distribution Board (o/g feeder 10 Nos) Outdoor type |
| 89 | Mandatory spares |
| 90 | 33kV ,400/1-1A, 2core single phase CT |
| 91 | Master trip relay |
| 92 | Bay control unit |
| 93 | O/C &E/F relay |
| 94 | 33kV LA |
| 95 | 33kV Vacuum CB |
| 96 | Mandatory spares for 33 kV Isolators |
| 97 | 33kV, 25KA,1250A isolators female/fixed contact |
| 98 | 33kV,25kA,1250A isolator male/moving contact |
| 99 | C&R Panel |
| 100 | 33 kV feeder C&R panel (Simplex type) with BCU, ethernet switch with all accessories suitable for SAS integration with existing SAS (Make:SIEMENS) |
| 101 | Erection of mounting structure as required ,including construction of foundation and supply of all foundation materials including labour cost etc. and structure earthing |
| 102 | 33 kV Vacuum CB |
| 103 | 33 kV CT |
| 104 | 33 kV Isolator (one with earth switch and two without earth switch) |
| 105 | 33kV LA |
| 106 | 33KV Post insulator |
| 107 | Erection, testing and comissioning including laying of control cables and equipments earthing as required |
| 108 | 33 kV VCB |
| 109 | 33 kV CT |
| 110 | 33 kV Isolator (one with earth switch and two without earth switch) |
| 111 | 33 kV LA |
| 112 | 33 kV Post Insulator |
| 113 | Installation of earthing system |
| 114 | Installation of earth electrode with test links including contruction of covered earth pits |
| 115 | Construction of extended earthmat using GI flat and connection to risers for equipment earthing as directed |
| 116 | Construction of cable trench and slab (supply of all materials including labour cost etc.) |
| 117 | C-type |
| 118 | D-type |
| 119 | Switchyard PCC and gravelling |
| 120 | Providing 80 mm thick PCC based in prop 1:4:8 as per drawing and specifications including supply of all materials and labour |
| 121 | Providing switchyard gravelling (100 mm thickness) levelling etc as per directive of site engineer. |
| 122 | Installation and commissioning of the C&R panel |
| 123 | Erection testing & Commissioning of C&R panel and intregration with existing SAS (Including Testing and Commissioning) of Make: SIEMENS |
| 124 | Dismantling of existing equipment, structre, foundation etc. as per site requirment. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender