Tender For special Repair Of Boundary Wall Of Helipad Area And special Repair To Drainage From Rp Gate To Helipad Of Avn Sqn Under Ge Nagrota
Tender Overview
Project Description
Tender for special Repair Of Boundary Wall Of Helipad Area And special Repair To Drainage From Rp Gate To Helipad Of Avn Sqn Under Ge Nagrota
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-Jul-2026 | REVISED BOQ | BOQ | 22-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick work, stone/boulder masonry built in cement mortar complete all as specified and directed. |
| 2 | M&L for Brickwork with sub class ‘B’ bricks old size, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 CM complete all as specified and directed. |
| 3 | All as per ser item No 2 but except bricks |
| 4 | M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and directed. |
| 5 | All as per ser item No 4 but except stones |
| 6 | M&L for Brick work with sub class 'B' (old size) bricks, straight or curved on plan to any radius built in cement sand mortar 1:6, complete all as specified and directed. |
| 7 | All as per ser item No 6 above but except bricks |
| 8 | Taking down cement plaster on brick or stone walls, etc .including raking out joints, hacking for key, scrubing down with water etc complete all as specified and directed. |
| 9 | M&L for Rendering 15mm thick in cement mortar 1:4 on on fair faces of brickwork/ stone masonry surfaces or concrete surfaces or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | Providing, cement concrete Type B-0 1:2:4 (12.5mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 11 | Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below & above GL) unreinforced complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 13 | M&L for Cement concrete Type C2 (1:3:6) using 40 mm graded crushed stone aggregate in surface channels and drains complete all as specified and directed. |
| 14 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 15 | M&L for Precast reinforced cement concrete M-15 (1:2:4 nominal mix ) type B-I, (Using 20mm grade crushed stone aggregate) set in cement mortar 1:4 as in cover slab , drain cover, manhole cover or etc. complete all as specified and directed. |
| 16 | M&L for TMT MS bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | M&L for Mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to E-165 (Fe-290) complete all as specified and directed. |
| 18 | S&F Reinforced concrete pipes, 600mm dia class NP2, ISI marked laid and jointed complete with collars complete all as specified and directed. |
| 19 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 20 | Excavating over areas not exceeding 1.5 m deep and getting out as in any type of soil complete all as specified and directed. |
| 21 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 22 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 23 | M&L for RCC type M-25 (design mix) using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 24 | M&L for RCC type M-25 (design mix) using 20 mm graded stone aggregate as in walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses for box type of culvert complete all as specified and directed. |
| 25 | M&L for RCC type M-25 (design mix) using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 26 | M&L for mild steel bars 5 mm dia over and upto including 10mm dia in stirrups , spacers and binders and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 27 | M&L for Formwork to sides of concrete foundations, footings, bases of columns raft and raft beams sides and soffits (if any) of foundation and plinth beams: and similar work vertical to batter complete all as specified and directed. |
| 28 | M&L for Formwork to faces of walls, retaining wall, abutments, parapets, staircase railing and similar works including attached pillasters, buttressess etc in rough finished flat surface of concrete complete all as specified and directed. |
| 29 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed. |
| 30 | Removing Demolition material to a distance of 500m or under outside MoD land including loading / unloading and stacking at the destination complete all as specified and directed. |
| 31 | Cleaning of drain or channel in any depth and in any position by reomoving liquid mud /soil, organic or inorganic matters form the drain and making it good for repair work including desposing the waste as per SSR clause complete all as specified and directed. |
| 32 | M&L for Reinforced cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in beams, cantilivers, bressummers, lintels over 1.5 m span complete all as specified and directed. |
| 33 | M&L for use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. on flat rough finished surface of concrete complete all as specified and directed. |
| 34 | TMT bars 10mm dia & over cut to length bent to shape required including, cranking, bending spirally, hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 35 | M&L for preparation of new plastered/unplastered surface and finishing walls with Acrylic Smooth exterior paint of required shade as approved by GE with two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on walls over 3mm thick plaster of paris putty including necessary scaffolding etc complete all as specified and directed.Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b) The acrylic emulsion paint work shall be carried out by using smart painting tools and techniques as specified in Particular Specifications and Contractor will have to produce necessary documents for purchase of smart painting tools or rent receipt of these tools along with bill/RAR.The bidders are requested take this aspect in consideration before quoting their rate and no claim on account of misunderstanding or otherwise shall be admissible on this account. (c) The painting is to be done in one or more shades as approved by GE. |
| 36 | M&L for preparation of old decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasy spots and finishing walls with Acrylic Smooth exterior paint of required shade as approved by GE with two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on walls over 3mm thick plaster of paris putty including necessary scaffolding, etc complete all as specified and directed.Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b) The acrylic emulsion paint work shall be carried out by using smart painting tools and techniques as specified in Particular Specifications and Contractor will have to produce necessary documents for purchase of smart painting tools or rent receipt of these tools along with bill/RAR.The bidders are requested take this aspect in consideration before quoting their rate and no claim on account of misunderstanding or otherwise shall be admissible on this account. (c) The painting is to be done in one or more shades as approved by GE. |
| 37 | M&L for preparation of old decorated plastered or unplastered surface including complete removal of existing treatment by machinary only, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasy spots and applying two coat of cement base paint on walls complete all as specified and directed.Note: (i) The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage. |
| 38 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement concrete and making good disturbed ground complete all as specified and directed. |
| 39 | Dismantling of Barbed wire in fencing of any description complete all as specified and directed. |
| 40 | S&F mild steel work such as in angle iron fencing posts swan neck, struts and flat iron fillets, gates etc,cutting tops to shape as directed including drilling hole, punching,splitting ends to secure chain link fencing or fixing of barbed wire to posts including all necessary cutting, welding bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 quality complete all as specified and directed. |
| 41 | Fixing only Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 42 | S&F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as complete all as specified and directed. |
| 43 | S&F in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified and directed. (Each line wire to be measured) |
| 44 | Restraining and resecuring including making good staples etc. galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing and straining rails and straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire stapples or steel pins etc. complete all as specified and directed. (Each line wire to be measured) |
| 45 | S&F in Repair Punched Tape Concertina Coil (including spike and handle) with 56 loops and dia 600mm, Max covered length 10 RM, having a core wire of high carbon spring steel of high tensile strength conforming to IS 4454/Part-I/Grade-SM, duly hot dipped galvanized with heavy zinc coating with minimum 230 gms per Sqm. The punched tape and core wire (2.5 + 0.35mm dia) shall be heavy galvanized (IS-1730) (Wire-275GSM & strip-200 GSM) conforming to IS-513 to provide protection against outdoor exposure. The punched tape shall mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of the coil. The width of strip as 19mm and spacing of blades 24.00 + 0.5 mm C/C. The weight of each coil shall be 8.50 + 5% Kgs without packing material and coil length 10 Mtr (maximum) when opened up, (Each coil should packed with bituminized hessian cloth for providing protective packing) as in fencing including fixing with special galvanised fasteners such as J clips, C clips, U clips fixed at any height on compound wall including dismantling old concertina coil wire including necessary scaffolding as required complete all as specified and directed.[Note: After stretching the coil the length of the compound wall on which it has been stretched shall be measured as straight length for payment] |
| 46 | M&L for framed work such as grills , gratings etc with ends of bars shouldered and /or riveted or forged into spikes , framed guard bars, barred iron doors, ladders, framed balusters: walk ways , railings frame work of water tanks and similar work confirming to Fe290, Gde E-165 complete all as specified and directed. |
| 47 | M&L for Preparation of new steel surfaces or iron works of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 48 | M&L for Prepartion of old steel and iron surfaces exceeding 10cm width or girth and applying one coat of synthetic enamal paint, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 9 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender