| Sl. No. | Item Description |
| 1 | Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power) etc complete and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. |
| 2 | Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs,isolator, etc complete all as specified and as directed by Engineer-in charge.. |
| 3 | Taking down existing unserviceable sub main wirings with PVC conduits / PVC casing-caping and making good disturbed surfaces complete all as specified and as directed by Engineer-in charge. |
| 4 | M&L for point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables (FRLS) drawn through and including surface type in PVC Conduits with all accessories complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable (FRLS) green in colour as earth continuity wire connecting to common earth point including 1.6 mm thick mild steel sunken boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of steel screws for mounting switches, sockets, regulators etc complete for one light/fan/bell point controlled by one ,one way switches complete all as specified and as directed by Engineer-in charge. |
| 5 | All as per item No. 4 above but One light point controlled by 2- way switches, with cables 1.5 sqmm size.complete all as specified and as directed by Engineer-in charge. |
| 6 | All as per item No. 4 above but one 5 Amps 3/5 pin socket outlet on the same board with other switches. |
| 7 | All as per item No.4 above but one 5 Amps 3/5 pin socket outlet on independent board. |
| 8 | All as per item No. 4 above but wiring with 2.5 sqmm copper cables with 2.5 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on independent board. |
| 9 | All as per item No. 4 above but wiring with 4 sqmm copper cables with 4 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on independent board. |
| 10 | M&L for point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables (FRLS) passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable (FRLS) green in colour as earth continuity wire connecting to common earth point including including 1.6 mm thick mild steel sunken boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of steel screws for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed by Engineer-in charge. |
| 11 | All as per item No 10 here-in-before but one 5 Amps 3/5 pin socket outlet on the same board with other switch. |
| 12 | All as per item No 10 here-in-before but one 5 Amps 3/5 pin socket outlet on independent board. |
| 13 | All as per item No. 10 above but wiring with 2.5 sqmm copper cables with 2.5 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on independent board. |
| 14 | All as per item No. 10 here-in-before but wiring with 4 sqmm copper cables with 4 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on indipendent board. |
| 15 | All as per item No 10 here-in-before but wiring in existing conduit / casing caping for one light/fan/bell point controled by one , one way switch 5 Amps . |
| 16 | All as per item No 10 here-in-before but wiring in existing conduit / casing caping for one 5 Amps 3/5 pin socket outlet on the same board with other switch. |
| 17 | All as per item No 10 here-in-before but wiring in existing conduit / casing caping for one 5 Amps 3/5 pin socket outlet on independent board. |
| 18 | All as per item No. 10 here-in-before but wiring in existing conduit / casing caping for wiring with 4 sqmm copper cables with 4 Sqmm copper cable as continuous earth wire for one 5/15 Amps switch socket outlet on indipendent board. |
| 19 | S&F switch piano, flush button, 5/6 Amps single pole, one way, 230 Volts.complete all as specified and as directed by Engineer-in charge. |
| 20 | S&F Switch piano, flush button, 5/6 Amps, single pole, two way, 230 Volts complete all as specified and as directed by Engineer-in charge. |
| 21 | S&F socket outlet, 3/5 pin, 5 Amps, flush type. complete all as specified and as directed by Engineer-in charge. |
| 22 | S&F switch socket combination, 3/5 pin, 5 Amps, flush type. Complete all as specified and as directed by Engineer-in charge. |
| 23 | S&F Switch socket combination multi-purpose 3pin, 15 Amp and 3 pin, 5 Amps complete all as specified and as directed. |
| 24 | S&F Ceiling rose surface bakelite 65x50 mm, two to three terminals.complete all as specified and as directed. |
| 25 | S & F Bell push,flush type,5 Amp. complete all as specified and as directed. |
| 26 | S & F stepped type electronic fan regulator flush type 220 Volt all as specified and as directed. |
| 27 | M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cable (FRLS) drawn through and including Concealed in PVC Conduits with all accessories complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable (FRLS) green in colour as earth continuity wire connecting to common earth point including 1.6 mm thick mild steel Modular Metal flush box of suitable size for mounting switches, sockets, regulators etc complete for one light/bell point /ceiling fan/ exhaust fan controlled by one ,one way switches complete all as specified and as directed by Engineer-in charge. |
| 28 | All as per item No. 27 above but one 5 Amps 3/5 pin socket outlet on independent board. |
| 29 | All as per item No. 27 here-in-before but one 5 Amps 3/5 pin socket outlet on the same board with other switches. |
| 30 | All as per item No. 27 here-in-before but wiring with 4 sqmm copper cable with 4 Sqmm copper cable as continuous earth wire for one 5/6 pin /16 Amps socket out let on independent board. |
| 31 | S&F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 32 | S&F Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 33 | S&F modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed. |
| 34 | S&F modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 35 | S&F modular type fan regulator 120 Watts , 2 module , complete all as specified and directed. |
| 36 | S&F modular type bell push switch , 1 module , complete all as specified and directed. |
| 37 | S & F modular white cover plate with frame, 2 module complete all as specified and as directed. |
| 38 | All as per item No 37 above but 3 module |
| 39 | All as per item No 37 above but 6 module |
| 40 | All as per item No 37 above but 8 module |
| 41 | S & F Buzzer,Ding Dong AC,230 volts,single pole.complete all as specified and as directed. |
| 42 | S & F LED light fitting,1x10 watt bulk head luminaries,,6500k CCT , IP65 made of PDC aluminium with opal diffuser etc.complete with all accessories including taking down old one complete all as specified and directed. |
| 43 | S & F LED batten suitble for indoor application 20 W, 4' length , wall mounted with polycarbonate housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down old complete all as specified and as directed by Engr-in-Charge |
| 44 | S & F LED batten suitble for indoor application 10 W, 2' length , wall mounted with polycarbonate housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down old complete all as specified and as directed by Engr-in-Charge. |
| 45 | Supply and fix recess mounted low glare LED flat panellight 2'X2' size deep drawn CRCA sheet steel housing duly powder coated in slim housing with high efficient LEDs & glare free opal diffuser, IP-20 and system efficacy minimum 100 lm/W, of 36 watt white/warm white for armstrong/grid ceiling mounting system complete prewired using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100 V grade including taking down old complete all as specified and directed. |
| 46 | Supply and fix recess mounted low glare LED flat panellight 2'X2' size deep drawn CRCA sheet steel housing duly powder coated in slim housing with high efficient LEDs & glare free opal diffuser, IP-20 and system efficacy minimum 100 lm/W, of 36 watt white/warm white for POP ceiling mounting system complete prewired using 1.5 Sqmm FRLS PVC insulated (Unsheathed) 3 core copper conductor cable, 1100 V grade including taking down old complete all as specified and directed. |
| 47 | S&F 5/6 watt LED recess mounted LED edge lit slim down light with die cast aluminium housing finished in premium white powder coating with efficacy min 100 lumen/watt round/square type as per site conditions warm white/white including connecting up with twin core flexible copper conductor cable and taking down old fitting complete all as specified and directed. |
| 48 | S&F 12 watt LED recess mounted LED edge lit slim down light with die cast aluminium housing finished in premium white powder coating with efficacy min 100 lumen/watt round/square type as per site conditions warm white/white including connecting up with twin core flexible copper conductor cable and taking down old fitting complete all as specified and directed. |
| 49 | S&F 15 watt LED recess mounted LED edge lit slim down light with die cast aluminium housing finished in premium white powder coating with efficacy min 100 lumen/watt round/square type as per site conditions warm white/white including connecting up with twin core flexible copper conductor cable and taking down old fitting complete all as specified and directed. |
| 50 | S&F 20 watt LED recess mounted LED edge lit slim down light with die cast aluminium housing finished in premium white powder coating with efficacy min 100 lumen/watt round/square type as per site conditions warm white/white including connecting up with twin core flexible copper conductor cable and taking down old fitting complete all as specified and directed. |
| 51 | S & F LED 25 Watt street light fitting made of PDC aluminium housing with energy efficient LEDs, direct modular IP lens, IP66 and with system efficacy of 120 lm/W for bldg secutiry complete with light grade GI brackets, Nuts, bolts, clamps complete with all accessories internaly pre wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old complete as specified and as directed by Engineer in charge |
| 52 | M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked PVC casing and capping with all necessary accessories complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC casing andcapping with all necessary accessories will be measured as one length). |
| 53 | M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC casing and capping with all necessary accessories complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC casing and capping with all necessary accessories will be measured as one length). |
| 54 | M&L sub main wiring surface type/ concealed type as required at site with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length). |
| 55 | M&L sub main wiring surface type/conealed type as required at site with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length). |
| 56 | M&L sub main wiring surface type/conealed type as required at site with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Four runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length). |
| 57 | M&L sub main wiring surface type/conealed type as required at site with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 10 Sqmm, 1100 volts grade (FRLS) and one run of 10 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Four runs of 10 Sqmm cable, one run of 10 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length). |
| 58 | M&L sub main wiring surface type/conealed type as required at site with four runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 16 Sqmm, 1100 volts grade (FRLS) and one run of 16 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows complete all as specified and as directed. (Note :- Four runs of 16 Sqmm cable, one run of 16 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length). |
| 59 | Supply and fix in repair single pole and neutral enclosures with a two pin and earth plug and socket complete with one double pole MCB 20 A , 240 V complete all as specified and as directed. |
| 60 | S&F factory made board distribution in sheet steel enclosure without bus bar SPN, 2 way, 240 Volts suitable for fixing MCBs.complete all as specified and as directed by Engineer-in charge. |
| 61 | S&F Factory made board distribution in sheet steel enclosure with 200 Amps rated bus bar SPN, 4 way double door 240 Volts suitable for fixing MCBs.complete all as specified and as directed by Engineer-in charge. |
| 62 | S&F sheet metal enclosure, (for DB's when MCBs to be used), flushed in wall single pole and neutral Double door, 8 way, 240 Volts with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed. |
| 63 | S&F sheet metal enclosure, (for DB's when MCBs to be used), flushed in wall single pole and neutral Double door, 12 way, 240 Volts with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed. |
| 64 | S&F MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, TPN 4 way with 200 Amps rated bus bar , 415 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed. |
| 65 | Supply and fix load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 125 Amps, 16 KA, busbars , neutral link, blanking plates and IP 43 protection complete with all accessories all as specified and as directed by Engineer-in-Charge. Note: Outgoing MCBs shall be measured and paid separately. |
| 66 | Supply and fix load line distribution board TPN vertical, 8 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 125 Amps, 16 KA, busbars , neutral link, blanking plates and IP 43 protection complete with all accessories all as specified and as directed by Engineer-in-Charge. Note: Outgoing MCBs shall be measured and paid separately. |
| 67 | S&F MCB, SP, 240 Volts, 5 to 32 Amps. 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB complete all as specified and as directed |
| 68 | S&F MCB, SPN, 240 Volts, 5 to 32 Amps. 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and neutral in the MCB DB complete all as specified and as directed |
| 69 | S&F MCB, SPN, 240 Volts, 40 to 63 Amps. 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and neutral in the MCB DB complete all as specified and as directed |
| 70 | S&F MCB, TPN, 415 Volts, 16 to 32 Amps., 10 KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral in the MCB DB complete all as specified and as directed |
| 71 | S&F MCB, TPN, 415 Volts, 40 to 100 Amps., 10 KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral in the MCB DB complete all as specified and as directed Please Enable Macros to View BoQ information |
| 72 | S&F MCB, TPN, 415 Volts, 40 to 100 Amps., 10 KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral in the MCB DB complete all as specified and as directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender