Tender For Repair/Maintenance Of Unserviceable Internal Wiring Electrical Fittings, Repairs/Ceiling/Exhaust Fans/Summer Appliances And Day To Day Electrical Complaints At D, E, F Type Officers Qtrs,Scientist Hostel, Dlomi & Swimming Pool At Drdo Town
Tender Overview
Project Description
Tender for Repair/Maintenance Of Unserviceable Internal Wiring Electrical Fittings, Repairs/Ceiling/Exhaust Fans/Summer Appliances And Day To Day Electrical Complaints At D, E, F Type Officers Qtrs,Scientist Hostel, Dlomi & Swimming Pool At Drdo Township Kanchanbagh Hyderabad.
BOQ
| Sl. No. | Item Description |
| 1 | Repair / maintenance of internal/Building light fittings of any type like tube lights / wall bracket light fittings / ceiling lights / mirror lights/ high& Medium bay lights in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like, tube rod, side holders, holders, lamps etc all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like, capacitor, lamp holder, connector, connection wire, LED tube, Bulbs etc, replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M. |
| 2 | (v) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below. (vii) The contractor should submit the copy of qualification,Experience as Electrician and police verification certificates while sigining the site orders.(viii) The contractor is fully responsible for providing the safety standards to be maintained by the electricians while attending the electrical defects.Any complaints pending for more than 72 hours, a penalty of Rs 100 per day per docket would be recovered. |
| 3 | S&F LED tube 20Watt, 6500K CCT,professional luminaries with luminous efficiency not less than 120Lm/watt, Single side connection with < 10% THD. Make: Havells/Polycab/Philips/Wipro |
| 4 | S&F in replacment indoor industrial type surface/wall mounted LED integral batten 20W, 6500K CCT, aluminium extruded body and polycarbonate diffuser, <10%THD, integral electronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete removing unserviceable fittings all as specified and directed. .Make : Havells/Polycab/Philips/Wipro |
| 5 | S&F in replacment LED PLL lamp Hercules 18Watt, professional luminaries single side connection with < 10% THD. Make: Make:Havells/ Jaquar/Crompton/Polycab/wipro |
| 6 | S&F in replacment indoor industrial type recess mounted LED Surface mounted for POP ceiling round downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency.15W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete removing unserviceable fittings all as specified and directedMake : Make:Havells/ Jaquar/Crompton/Polycab/wipro |
| 7 | S&F in replacment indoor industrial type recess mounted LED Surface mounted for Recessed Mounting ceiling round downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency.15W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete removing unserviceable fittings all as specified and directedMake : Make:Havells/ Jaquar/Crompton/Polycab/wipro |
| 8 | S&F led luminaire 600 mm x 600 mm 35/36 watt, 220V AC recessed/surface mounted type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete. Make:Havells/ Jaquar/Crompton/Polycab/wipro |
| 9 | Supply & Fix in replacement recess mounted LED luminaire 36W 2'x2', 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for POP ceiling or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed. Make : Make:Havells/ Jaquar/Crompton/Polycab/wipro |
| 10 | Supply & Fix recess mounted LED luminaire 36W 4'x1' of size 1195x295x70 mm, 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for Armstrong/ US Gypsum or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed. Make:Make:Havells/ Jaquar/Crompton/Polycab/wipro |
| 11 | S&F in replacement recess mounted LED high bay light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of luminous efficacy 150lm/watt 120W, 240V, 5000K CCT, aluminium heat sink alongwith inbuilt elctronic driver, wide beam angle , including hanging the fitting with required hook arrangement required at site. Make: Make:Havells/ Jaquar/Crompton/Polycab/wipro |
| 12 | S&F in replacement LED security light fiitting of luminous capacity 2500lumens,IP-66 protection, 5700K CCT, inbuilt electronic driver with <10%THD made up of die cast aluminium housing with high power LED as lighting source and lens embeded toughened glass cover, separate driver compartment complete fixing with GI bracket made out of 40mm bore GI pipe light grade 1.5Mtr long bend to shape and fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed by Engr-in-charge. Make:Havells/ Jaquar/Crompton/Polycab/wipro |
| 13 | Material and Labour for sub main wiring with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including one run of 2.5 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit all as specified and directed. Note : 2 Runs of 2.5 sqmm cable 1 run of 2.5 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. |
| 14 | All as per srl item No. 12 here-in-before but with 2 runs 4 sqmm including 1 run of 4 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia ISI marked PVC conduit..Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. |
| 15 | All as per srl item No. 12 here-in-before but with 2 runs 6 sqmm including 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia PVC conduit.Note : 2 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment. |
| 16 | All as per srl item No. 12 here-in-before, but sub main wiring with 4 runs of 4sqmm with 2 run of 4 sqmm copper conductor FRLS as earth continuity wire in not less than 25mm dia PVC conduit.Note : 4 Runs of 4 sqmm cable 2 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment. |
| 17 | Material and Labour for sub main wiring with 4 runs of 6 Sqmm single core ISI marked PVC insulated unsheathed cable 1100 Volts grade multistranded copper conductor cable drawn through in and including surface/concealed rigid PVC conduit medium grade of size not lless than 25mm dia and conduit accessories such as bends, tees, junction boxes type on walls, roof, floors etc.. including providing 2 runs of 6 Sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable as earth continuity conductor and connecting to earth dolly wire including taking down unserviceable sub main wiring and conduit all as specified and directed. Note :- 4 Runs of 6 sqmm cable 2 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment including taking dow unserviceable sub main wiring including conduit all as directed.Make for Item No 12 to 16 :For Copper wire : Finolex/Nicco/Havells/Gloster/KEIFor PVC conduit : Sudhakar/Polyplast/Supreme/GM Make of Gang Boxes: GM/Havells/Legrand |
| 18 | Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, in PVC casing & caping type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-One light/ fan point controlled by one, one way switch |
| 19 | One socket outlet 5 pin 5 amps controlled by one switch on same board. |
| 20 | One socket outlet 5 pins 5 amps controlled by one switch on independent board. |
| 21 | All as per item No. 19 here-in-before but wiring with 4.00 Sqmm for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 4 Sqmm PVC insulated multi stranded copper earth continuity conductor and connected to common earth dolly. Make For Copper wire : Finolex/Havells/Gloster/KEI.For PVC conduit :Sudhakar/Polyplast/ GM/Modi. NOTE : The Contractor is responisible for arranging all tools required at site. |
| 22 | Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:-One light/ fan point controlled by one, one way switch |
| 23 | One light point controlled by one, two way switch |
| 24 | One 5 Amps socket point on independent board. |
| 25 | One 5 Amps socket point on same board with other switches |
| 26 | All as per item No. 24 here-in-before but wiring with 2.5 Sqmm FRLS for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 2.5 Sqmm PVC insulated multi stranded FRLS copper earth continuity conductor and connected to common earth dolly. |
| 27 | All as per item No. 24 here-in-before but wiring with 4.00 Sqmm FRLS for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 4 Sqmm PVC insulated multi stranded FRLS copper earth continuity conductor and connected to common earth dolly. |
| 28 | S&F in repairs PVC / polycarbonate Angle/Batten type lamp holders retrofit type.Make: Anchor/GM/Cona |
| 29 | S&F in replacement for white cover plate with frame 8 module. |
| 30 | S&F in replacement for white cover plate with frame 6 module. |
| 31 | S&F in replacement for white cover plate with frame 4 module. |
| 32 | S&F in replacement for white cover plate with frame 3 module. |
| 33 | S&F in replacement for Modular socket 6A 2/3 Pin 2 module. |
| 34 | S&F in replacement for Modular socket 16A 2/3 Pin 2 Module. |
| 35 | S&F in replacement for modular switch 1 way 6A 1 module. |
| 36 | S&F in replacement for modular switch 1 way 16A 1 module. |
| 37 | S&F in replacement of modular fan regulator 120W,240V, 2module, suitable for ceiling fan of 1200/1400mm sweep. |
| 38 | S&F in replacement of modular fan regulator 120W,240V, 1 module, suitable for ceiling fan of 1200/1400mm sweep. |
| 39 | S&F in replacement for modular switch 2 way 6A 1 module. Make of item No 6 to 14: L&T/Schneider/Crabtree |
| 40 | S & F in replacement of switch piano flush type 5 Amps SP one way all as specified. (Make:-Anchor/Cona/GM) |
| 41 | S & F in replacement of switch piano flush type 15 Amps SP one way all as specified. (Make:-Anchor/Cona/GM) |
| 42 | S&F in replacement of fan regulator 120W,240V, switch type suitable for ceiling fan of 1200/1400mm sweep. |
| 43 | S&F in replacement of fan regulator 120W,240V, socket type suitable for ceiling fan of 1200/1400mm sweep. |
| 44 | S & F in replacement of socket combination 5 Amps flush mounted 3/5 pin multi purpose all as specified. Make:-Anchor/Cona/GM |
| 45 | S & F in replacement of socket combination 5/15 Amps flush mounted 3/5 pin multi purpose all as specified. Make:-Anchor/Cona/GM |
| 46 | Supply and fix in replacement MCB DB 08 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Make: Legrand/ Schneider/L&T/C&S |
| 47 | Supply and fix in replacement MCB DB 04 way SPN (single door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed . Make: Legrand/ Schneider/L&T/C&S/Havells |
| 48 | Supply and fix in replacement MCB DB 12 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells |
| 49 | Supply and fix in replacement VTPN DB 04 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 250 amp rated copper busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits including provision of incoming MCCB & outgoing SP/TP MCBs as outgoing complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells |
| 50 | Supply and fix in replacement MCB TPN DB 04 way (double door) sheet metal enclosure factory made suitable for MCB TPN incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells |
| 51 | Supply and fix in replacement VTPN DB 08 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits including provision of incoming MCCB & outgoing SP/TP MCBs as outgoing complete as reqd at site as directed. Make: Legrand/ Schneider/L&T/C&S/Havells |
| 52 | Supply and fix in replacement VTPN DB 12 way (double door) sheet metal enclosure factory made suitable for MCCB 415 volts incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits including provision of incoming MCCB & outgoing SP/TP MCBs as outgoing complete as reqd at site as directed. Make : Legrand/L&T/Schneider/Havells |
| 53 | Supply and fix inreplacement of MCB single pole 6-32 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all as specified and directed. |
| 54 | S&F in replacement of MCB SPN 32-40 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all as specified and directed. |
| 55 | S&F in replacement of MCB TP 40 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve all as specified and directed. |
| 56 | S&F in replacement of MCB TPN 63 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve all as specified and directed. |
| 57 | Supply & Fix in replacement PVC insulated round cable 3 core stranded copper conductor 2.5 sqmm as in connection cord. |
| 58 | Supply and fix in replacement metal clad plug top 3 pin, 20 amps, ISI marked heavy duty for AC connection cord. |
| 59 | Supplying and fixing 1100 volts grade cable PVC insulated copper strandard conductor cable of size 1.5 sqmm flat or circular complete all as specified and directed. |
| 60 | All as per item No. 58 above but of size 2.5 sqmm |
| 61 | All as per item No. 58 above but of size 4.0 sqmm |
| 62 | All as per item No. 58 above but of size 6.0 sqmm |
| 63 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 64 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender