Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56240946

Tender For Repair To Drains, Compound Wall, Repair And Desilting, Cleaning/Replacement Of Float Valve Oh Tanks, Repair And Maintenance Of Internal Wiring, Ceiling Fan, Security Light Along With Allied Wks In Sila Grn Under Age Reasi Of Ge Nagrota

Issued by Statutory Bodies & Commissions/Committees · Jammu, Jammu and Kashmir
Tender Value
50 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
15 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair To Drains, Compound Wall, Repair And Desilting, Cleaning/Replacement Of Float Valve Oh Tanks, Repair And Maintenance Of Internal Wiring, Ceiling Fan, Security Light Along With Allied Wks In Sila Grn Under Age Reasi Of Ge Nagrota

BOQ

Name of Work:-
Sl. No. Item Description
1Demolition of trellis work (Jafri), including taking as under of battens intrellis (posts and rails measured separately) complete all as specified and directed.
2Demolition of Brickwork or stone/boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
3Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
4Taking down cement plaster on brick or stone walls or any description, including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
5M & L for RCC (Type B1 1:2:4 of 20 mm graded crushed stine aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
6M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
7M& L for RCC (Type B1 1:2:4 of 20 mm graded crushed stone aggregate) Columns, pillars, piers, posts and struts complete all as specified and directed.
8M & L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide complete all as specified and directed.
9M & L mild steel bars10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and direceted
10M & L mild steel bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and direceted
11M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:6 complete all as specified and directed.
12M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
13M & L PCC 1:3:6 20 mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water roughs and the like including weathering, slightly rounded or hamfered angles and throating, complete all as specified and directed.
14M & L for Rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 with water proofing compound finished fair and smooth complete all as specified and as directed.Note: water proofing compound shall be measured seprately.
15Supply only liquid water proofing compound complete all as specified and directed.
16Material & Labour for priming new surface of wall with alkali resistant priming coat and applying two coats of cement base paint complete all as specified and directed.Note: The painting is to be done using smart painting tools and technique as mentioned in Particular specification. Tenderer shall take this aspect in consideration before quoting his rates and no claim on account of misunderstanding or any thing else shall be admissible/acceptable at any later stage.
17Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
18M&L 100mm thick Cement concrete type 1:3:6 type C-2(using 40 mm graded crushed stone aggregate) as in floors including necessary formwork etc complete all as specified and directed.
19M&L coloured rubberised Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and directed.
20Supply only Fine aggregate (sand) for laying to floor finishes complete all as specified and directed.
21M&L coloured and with white cement & pigments chequered cement concrete tiles 20cmX20cmx25mm thick set jointed and pointed in neat cement slurry in floors complete all as specified and directed.
22M&L for cement concrete (type 1:2:4 20mm graded crushed aggregate in kerbs or mud stops rounded or chamfered on edges complete all as specified and directed.
23M&L Random rubble stone masonry uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
24Rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth complete all as specified and as directed.
25M & L 20 mm thick rendering in cement mortar 1:4 over stone wall suface finished even and smooth without using extra cement complete all as specified and as directed.
26M & L for Preparing new plastered or unplastered surfaces and applying three coats of white wash on walls complete all as specified and as directed.
27Extra for forming fair faces (finished drain of channel 30 cm inner grith in cement concrete using extra cement including forms moulds mitred stopped end etc complete, all as specified and directed.
28Cleaning of sewage lines which are blocked /filled with sludge, semi solid/ material etc by roding manholes to manholes manually or by sewage cleaning machine without causing any damage to sewage line / manholes manholes covers taking out and refixing the covers and removing the sludge to a non inhabitant area or buried into ground all as specified for the 150mm internal dia of pipe complete all as specified and directed.
29Cleaning of sewage lines which are blocked /filled with sludge, semi solid/ material etc by roding manholes to manholes manually or by sewage cleaning machine without causing any damage to sewage line / manholes manholes covers taking out and refixing the covers and removing the sludge to a non inhabitant area or buried into ground all as specified for the 100mm internal dia of pipe complete all as specified and directed.
30Cleaning of septic tanks, soakage well of any capacity and manholes by Desludging / dewatering including inlet/ outlet chambers, removing out all scum, silt, residuals sludge (both organic and inorganic nature) after plugging the incoming sewage lines through combined high pressure water jetting cum suction (Vacuum) type machine mounted on LCV/HCV facility of high pressure vacuum and removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, complete all as specified and directed.
31Cleaning of blockage of any type of wc (Indian/pedestal) from WC pan to Ist manhole in single storied bldg including resetting/ refitting of asccess door in soil pipe where opened without causing any damage to the wc pan 'P' or 'S' trap and pipe including fitting complete all as specified and directed.
32Cleaning of blockage of any type in Nahani trap provided in bath room, kitchen and indoor waste water pipe of kitchen sinks and WHB and removing all the sludge and foreign material from the trap and waste pipe from blocked trap to gully trap/ surface drain wherever opened or without causing any damage to the trap and pipe complete all as specified and directed.
33Taking up or down steel tubing and connection for 15mm tubing incl cleaning for refing or removal complete all as specified and directed.
34Taking up or down steel tubing and connection for 20 mm tubing incl cleaning for refing or removal complete all as specified and directed.
35S&F GI tubing 15mm bore medium grade with all fittings fixed to wall, ceiling / floor complete all as specified and directed.
36S&F GI tubing 20 mm bore medium grade with all fittings fixed to wall, ceiling / floor complete all as specified and directed.
37Cleaning of service RCC/Ferro/PVC service/over head tank cleaning process as under (a) Dewatering using submerssible pump/bailing out of water to dispose the minimum level of dirty water from the tank. (b) Cleaning the tank/ UG sump bottom, walls and ceiling using high pressure water jet to dislodge the algae calcinations, dirt etc.(c) Disposing the dirt water sludge etc., using specially designed sludge removal pump.(d) Cleaning the tank inside throughly by using industrial grade vaccum pump to make the tank inside free from dirt, algea and sludge etc.(e) Treating the inside walls, bottom, ceiling of tank including all nooks and corners by using and spraying anti bacterial agent such as hydrogenperoxide (bio degradable) for disinfection of tank inside.(f) Total disinfection and sterlisation of tank hyginecally cleaned and bacteria free and safeby Eco-Friendly for storage of water. Note :- Incl cleaning of outlet pipe upto stop cock/gate valve by removing and refixing the same and making the line serviceable after cleaning & Qty of tank are consider for cleaning twice in a Year and Date of cleaning to be written over head tank after cleaning.
38For exc 250 ltrs and not exc 500 ltrs capacity
39For exc 501 ltrs and not exc 1000 ltrs capacity
40For exc 1001 lt and not exc 2000 lt capacty
41For exc 2001 lt and not exc 5000 lt capacty
42S & F Rotational moulded polyethylene water 500 ltr Capacity storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I incl Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe 20mmdia . (Minimum weight 2 0 m m - 2 1 0 g m s) Including taking down existing water tank and float valve complete all as specified and directed.
43S & F Rotational moulded polyethylene water 1000 ltr Capacity storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I incl Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe 20mmdia . (Minimum weight 2 0 m m - 2 1 0 g m s).Including taking down existing water tank and float valve complete all as specified and directed.
44Supply & Fixed in repairs brass float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to iron pipe of bore 20mm complete all as specified and directed.
45Supply & Fixed in repairs brass float valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to iron pipe of bore 15mm complete all as specified and directed.
46S & F in repair PVC (SWR) branch bends any radius 110mm bore of pipe complete all as specified and directed.
47S & F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floors complete all as specified and directed.
48S&L in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
49S&F as in repair Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests complete all as specified and directed.
50Supply & fixed PVC flushing cistern low level of capacity of 10 ltr, white, valve less symphonic action type complete with inlet ball valve float and handle or Push button type including brackets and fixed in repair complete all as specified and directed.
51S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mmcomplete all as specified and directed.
52Excavation in trenches in soft/ loose soil exc 1.5 m deep and getting out including forming bottom to required level or slop for laying pipe, concrete bed manhole etc n.exc 10 Sqm on plan complete all as specified and directed. (pipe and concrete bed shall be measured and paid separately )
53Returning filling in soft/ loose soil including spreading levelling ,watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
54Removing of excavated surplas materials to a distance exc 50 m but nexc 100 mm and depositing where directed a level n.exc 1.5 mtrs above the starting point complete all as specified and directed.
55Demolition or breaking up 150 mm dia drain pipe including fittings of any desciption in any position and removing rubbish upto a distance of n. exc 50 mtr complete all as specified and directed.
56M&L for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 for 150 m bore of pipe complete all as specified and directed.
57M&L Reinforced concrete pipes, class NP3, laid and jointed complete with collars 150 mm bore laid in trenches and jointed with CM 1:1 complete all as specified and directed.
58Demolition of brick work of any description and in any position built in CM and removing rubbish upto a distance of n exc 50 mtr complete all as specified and directed.
59M&L for brick work built in CM 1:4 with sub class 'B' bricks straight or curved on plan exc 6 m mean radius complete all as specified and directed.
60M&L for rendering 15 mm thick on fair faces of brick work internal faces in manhole/Drain in CM 1:4 using WPC as per manufacturer instruction incl finishing the surfaces even & smooth without using extra cement complete all as specified and directed.
61M&L rendering 15 mm thick on other than fair faces of brick surfaces or concrete surfaces and finished surfaces even & fair in CM 1:6 complete all as specified and directed.
62Demolition of reinforced cement concrete as in cover slabs of any description, removal of debris to beyond MD land complete all as specified and directed.
63M&L for precast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in manhole cover slab with plain fair faces and set in CM 1:4 complete all as specified and directed.
64M&L TMT mild steel bars 6 mm to 8 mm dia cut to length, bent to shape required, including cracking, bending, spirally for hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
65All as above Ser item No 60 but 10 mm dia MS round bar as in handle
66M& L for Excavating in post holes (or similar holes)in hard dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
67M&L PCC 1:4:8 Type D2 ( using 40mm graded crushed stone agg) , as in fdn filling and mass concrete complete all as specified and directed.
68S& F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed.
69M&L for Preparing steel painted New previously un-treated surface to receive painting, including washing and cleaning, one coat priming with Red oxide zinc chrome etc. over 10cm in width or girth, not otherwise described & applying two coats of synthetic enamel paint in any pattern complete all as specified and directed.
70Note: 1. The schedule rates include collecting of complaints from the concerned JE and returning done complaints at the earliest.2. The quantities are tentative and are liable to change as per day to day complaints .3. The Quantities are to be executed in day to day complaints and cannot be explained at the time of handing over of site.4. Supervisor will collect the complaints from the complaint cell and complete the same and feedback given to the complaint cell on same day & if complaint is not attended within 24 hour a penal recovery @ Rs. 1000.00 per complaint per day will be recovered from contractor due payment.5. A complaint register will be maintained by the contractor bearing details of every complaint attended shall be entered by the contractor daily including details like building No, Location etc, and the register shall be signed by contrcator, JE Civ and Engineer in Charge. The register will be submitted alongwith RAR/ Final bill for technical check.
71Taking down carefully surface aluminium or copper point wiring with PVC casing-caping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed.
72M&L for point wiring in repair with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-caping not less than 32x16 mm ISI marked ivory colour with all fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete all as specified and directed as required for the following :-
73One light point controlled by one switch.
74One fan point controlled by one switch.
75One socket outlet 6 Amp controlled by one switch on the same board with other switches.
76One socket outlet 6 Amp controlled by one switch on indepdendent board.
77One bell point controlled by one bell push.
78M&L for point wiring in repair with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-caping not less than 32x16 mm ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets for one 16 Amp socket outlet point controlled by one switch on independent board complete all as specified and directed.
79S&F in repair angle holder, insulated polycabonate body with back plate complete all as specified and directed.
80S&F in repair switch piano flush button single pole one way 6 Amp complete all as specified and directed.
81S&F in repair switch piano flush button single pole one way 16 Amp complete all as specified and directed.
82S&F in repair socket outlet 2 in 1, 3 pin 6 & 16 Amp flush type complete all as specified and directed.
83S&F in repair socket outlet 2 in 1, 2 & 3 pin, 6 Amp, flush type complete all as specified and directed.
84S&F in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
85S&F in repair Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and directed.
86S&F in repair Plug Top of socket outlet 6 Amp complete all as specified and directed.
87S&F in repair Plug Top of socket outlet 16 Amp complete all as specified and directed.
88S&F in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp box type complete universal complete all as specified and directed.
89S&F in repair Switch socket combination 2 in 1, 3 pin, 5 Amp box type complete universal complete all as specified and directed.
90S & F in repair Modular switch 5/6 Amps suitable for 1 Module complete all as specified and directed.
91S & F in repair Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified and directed.
92S & F in repair Modular switch 15/16 Amps suitable for 1 Module complete all as specified and directed.
93S & F in repair Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and directed.
94S & F in repair Modular Fan step Regulator electronic, 120 watts 2 Module complete all as specified and directed.
95S&F in repair ceiling rose 3 plates polycarbonate body complete all as specified and directed.
96S&Fin repair hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified and directed.
97S&F in repair bell push, flush type, 6 Amp 240 volts complete all as specified and directed.
98S&F in repair door bell, AC, 240 volts, single pole complete all as specified and directed.
99M&L in replacement of sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked minimum 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sq mm as earth continuity conductor connected to commen earth and earth dolly complete including taking down existing UNSV complete all as specified and directed.Note: Two runs of 6Sqmm FRLS PVC insulated unsheathed 1100 volts grade cable and One run of PVC conduit shall constitute as 1 RM for the measurement purpose.
100S & F Sub main wiring with PVC insulated, FRLS cable 2 single core 4 Sq mm 1100 V grade with stranded copper conductor on and incl PVC rigid non metalic conduit (ISI marked) in concealed incl all specials like joint, elbow , Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4 sq mm for earth continuity conductor complete all as specified and directed.Note: Two runs of 4Sqmm FRLS PVC insulated unsheathed 1100 volts grade cable and One run of PVC conduit shall constitute as 1 RM for the measurement purpose.
101M&L in repair for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as specified.
102S&F in repair MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 Amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces complete all as specified and directed as required with following ratings & ways:-
103SPN, in repair 240 volts, 4 ways.
104SPN, in repair 240 volts, 8 ways.
105SPN, in repair 240 volts, 12 ways.
106TPN, in repair 415 volts, 4 ways.
107S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed of following ratings:-
108Single pole 6 to 32 Amp.
109Single pole 40 to 63 Amp.
110Double pole 10 to 32 Amp.
111Double pole, 40 to 63 Amp.
112Four pole 40 to 63 Amp.
113S&F in repair LED tube light batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser and mounting accessories duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 22 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as specified and directed.
114All as pr Item No 24 here in before but for LED tube light batten warm type (Yellow Lumen) complete all as specified and directed.
115S&F in repair LED tube light batten (2 Fit ) made of CRCA sheet housing with a PC glossy difusser and mounting accessories duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as specified and directed.
116S&F in repair LED (bulb) fixture 18 watt including connection complete all as specified and directed.
117S&F in repair LED (bulb) fixture 12 watt including connection complete all as specified and directed.
118S&F in repair LED (bulb) fixture 10/9 watt including connection complete all as specified and directed.
119S&F in repair LED bulkhead fitting 9 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete all as specified and directed.
120S&F in repair energy efficient recessed mounted LED luminaire suitable for 2'x2' , 36 watt 230 V 50 Hz, grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 Sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required complete all as specified and directed.
121All as pr Item No 101 here in before but for LED luminaire warm type (Yellow Lumen) complete all as specified.
122Taking down unsv ceiling fans 1200/1400 mm sweep 230 v, AC supply, single phase from site, depositing in MES store yard, dismantling all parts, checking serviceability of all parts & continuity of copper winding, (Burn out winding Fan should be staking aside for rewinding), including cleaning all the components of fan, oiling , greesing, including reolacement of rusted /unsv nuts. bolts split Pin rubber reel machine screws, shaft, capacitor, clAmps, etc as required complete all as specified and directed.
123Taking down unsv Exhaust Fan 200/230/300 mm sweep 230 v, AC supply, single phase from site, depositing in MES store yard, dismantling all parts, checking serviceability of all parts & continuity of copper winding, (Burn out winding Fan should be staking aside for rewinding), including cleaning all the components of fan, oiling , greesing, including replacement of rusted unsv nut, bolts, rubber, machine screws. shaft, capacitor, clAmps. etc complete all as specified and directed.
124Taking out, burnt winding wire from ceiling fans (Which required rewinging, Obtained from item No.01) motor of 1200/1400 mm sweep 230 v, AC supply, single phase, Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & size, thoroughly cleaning all the components complete all as specified and directed.
125Taking out, burnt winding wire from Exhaust fans (Which required rewinging, Obtained from item No.02) motor of 300 mm sweep 230 v, AC supply, single phase, Transporting to contractor workshop for rewinding the same with super enameled copper winding wire of existing gauge/turns & size, thoroughly cleaning all the components of fan, oiling complete all as specified and directed.
126All as per Sri Item No 106 here-in-above but for exhaust fan of size 400/450 mm complete all as specified and directed.
127S&f in replacement ball bearing of ceiling / exhaust fan of any size and required with alignment of shaft and testing complete all as specified and directed.
128S& F in replacement of AC film capacitor 4.0 mfd, 440 volts suitable for any type ceiling fan/exhaust fan in FR plastic casing including connection complete all as specified and directed.
129S& F in replacemen of AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete all as specified and directed.
130Replacement of old unserviceable fan blades made of MS sheet duly powder coated ,of type make and colour as of ceiling fan suitable for 1200mm sweep ceiling fan of any make incl all accessories complete all as specified and directed.
131Replacement of Blade assembly of Exhaust fan with fixing hexagonal nut of size 300 to 450mm complete all as specified and directed.
132Replacement of iron Frame of exhaust fan 4 way with welded and painted complete all as specified and directed.
133M & L for Gun metal bush of exhaust fan complete all as specified and directed.
134S&f in replacement of rubber reel with a pair of clAmp, nuts, bolts, split pins etc suitable for ceiling fan down rods complete all as specified and directed.
135S&F in replacementl of PVC canopy suitable for ceiling fan of any size complete all as specified and directed.
136S&F in replacement of PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 Sqmm complete all as specified and directed.
137S&F in replacement of down rod of ceiling fan made of Gl pipe medium grade 15 mm bore of length upto 600 mm including cutting. threading. painting etc as required complete all as specified and directed.
138Taking down of desert cooler fixed at any position, cleaning internally and externally by scraping all scales dirt etc and repairs to desert cooler to check leakage, tightening ( By replacing screws, nuts and bolts etc) including painting of desert cooler with spray machine with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer, letters, Refixing of the desert cooler after necessary oilling and greasing of fan and water lifting pump complete all as specified and directed.
139Supplying in replacement Fan motor 1/6 HP, 230 volt, single phase for the existing desert cooler complete all as specified and directed.
140Supplying in replacement Water lifting pump, Vertical type, 18 watts, 230 volt, 50 C/S, single phase suitable for desert coolers complete all as specified and directed.
141Supplying in replacement Side panel made out of 1.0 mm thick Gl sheet, fixed with iron handle suitable for desert coolers of capacity 3000 cfm including two coats of synthetic enamel hammer tone paint over a one coat of red oxide primer on both side of Dane! complete all as specified and directed.
142Supplying in replacement High density polythene pipe 15 mm dia complete all as specified and directed.
143Supplying in replacement Complete steel body of desert cooler of capacity 3000 cfm duly painted with two coats of synthetic enamel hammer tone paint over one coat of red oxide primer. The body of desert cooler shall be fabricated complete all as specified and directed as under:- (a) The top and bottom made out of 1.25 mm thick Gl sheet.(b) side panels (set of three) made out 1.00 mm thick Gl sheet.(c) Front Grill of suitable size and of approved quality.
144Supplying and Replacement Three-way water distributor, heavy duty, PVC, including necessary nuts and bolts complete and taking out old distributor complete all as specified and directed.
145Supplying in replacement Selector Switch regulator, suitable for Desert coolers exhaust fan complete all as specified and directed.
146Supplying in replacement of capacitor 4 mfd suitable for Desert cooler complete all as specified and directed.
147Re-wiring of desert cooler with suitable size of copper conductor PVC insulated cable and providing main lead three metre long of 3 core PVC insulated copper conductor of size 23/ .0076 complete all as specified and directed.
148Dismantling and taking out Old, Unserviceable fan motor from the desert cooler and rewinding with supper enamel copper winding wire of suitable size, varnishing etc including replacement of bushes, assembling testing and refixing at the existing site complete all as specified and directed.
149M& L for fabrication of desert cooler stand made out of MS angle iron 40x40x6mm thick all as per existing size suitable at site incl painting ith two coats of synthetic enamelled paint over a coat of red oxide primer coat complete all as specified and directed.
150Repairs to voltage stabilizer, single phase with input voltage 135 - 190 V and output voltage 200-240 volt, capacity 5 KVA by dismantling and taking out burnt main transformer and rewinding with super enamelled copper wire of suitable size including varnishing and insulation material etc. complete all as specified and directed.
151All as above Ser item No 134 but for capacity 03 KVA
152All as above Ser item No 134but for capacity 01 to 02 KVA
153Disconnecting the inlet and outlet connections of the existing Geyser 25/50 Ltr, taking down carefully, cleaning/descaling the blocks both in Gl pipes and water heater refixing the bolts by proper grouting in the wall and refixing the water heater in the same or in other places complete all as specified and directed.
154S&F in place of unsv PVC connection of any make with (ISI Mark) having10mm dia, 45 cm long with steel reinforcement suitable for hot & cold-water geyser outlet supply with 02 Nos of Unions/ cup shaped cover with washers complete all as specified and directed..
155Replacement of unserviceable heating element of geyser 2KW/1.5 KW complete all as specified and directed.
156Replacement of unserviceable thermostat of geyser 2KW/1.5 KW complete all as specified and directed.
157S & F in replacement of pressure release valve suitable for 25/50 ltr electric water heater complete all as specified and directed.
158S&F in replacement of U/S apparatus plate of geysers 25/50 litre capacities by brazing not exceeding 5 mm thick complete all as specified and directed.
159Replacement of unserviceable Inner Tank of geyser steel body of capacity 25/50 Ltrs as existing patten complete all as specified and directed.
160Replacement of unserviceable PVC flexible pipe inlet 16mm outer dia and 450 mm long for hot/cold water heavy duty with brass nuts & bolts complete all as specified and directed.
161Disconnecting the inlet and outlet connections of the existing solar water heater 300 Ltr, taking down carefully, cleaning/descaling the blocks both in Gl pipes and water heater refixing the bolts by proper grouting in the wall and Refixing the water heater in the same or in other places complete all as specified and directed.
162Replacement of unserviceable- heating element of solar water heater 300 Ltr 2KW/1.5 KW complete all as specified and directed.
163Replacement of unserviceable thermostat of Solar water heater 300 ltr 2KW/1.5 KW complete all as specified and directed.
164Replacement of unserviceable appratus plate of Solar water heater 300 ltr capacity by brazing not exeeding 5 mm thick complete all as specified and directed.
165Supply only PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm complete all as specified and directed.
166Supply only PVC insulated FRLS multistranded copper conductor cable 2.5 Sqmm complete all as specified and directed.
167Supply only Angle holder,in repair insulated polycabonate body with back plate complete all as specified and directed.
168Supply only Switch piano flush button single pole one way 6 Amp complete all as specified and directed.
169Supply only Switch piano flush button single pole one way 16 Amp complete all as specified and directed.
170Supply only Socket outlet 2 in 1, 3 pin 6 & 16 Amp flush type complete all as specified and directed.
171Supply only Socket outlet 2 in 1, 2 & 3 pin, 6 Amp, flush type complete all as specified and directed.
172Supply only Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
173Supply only Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and directed.
174Supply only Plug Top of socket outlet 6 Amp complete all as specified and directed.
175Supply only Plug Top of socket outlet 16 Amp complete all as specified and directed.
176Supply only Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp box type universal complete all as specified and directed.
177Supply only Switch socket combination 2 in 1, 3 pin, 5 Amp box type universal complete all as specified and directed.
178Supply only Modular switch 5/6 Amps suitable for 1 Module complete all as specified and directed.
179Supply only Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified and directed.
180Supply only Modular switch 15/16 Amps suitable for 1 Module complete all as specified and directed.
181Supply only Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and directed.
182Supply only Modular Fan step Regulator electronic, 120 watts 2 Module complete all as specified and directed.
183Supply only Ceiling rose 3 plates polycarbonate body complete all as specified and directed.
184Supply only Hum free electronic step fan regulator 120 - 280 volts of 100 watt complete all as specified and directed.
185Supply only MCBs of 'C' series having breaking capacity 10 KA, ISI marked Single pole 6 to 32 Amp complete all as specified and directed.
186Supply only MCBs of 'C' series having breaking capacity 10 KA, ISI marked Single pole 40 to 63 Amp complete all as specified and directed.
187Supply only MCBs of 'C' series having breaking capacity 10 KA, ISI marked Double pole 10 to 32 Amp complete all as specified and directed.
188Supply only MCBs of 'C' series having breaking capacity 10 KA, ISI marked Double pole, 40 to 63 Amp complete all as specified and directed.
189Supply only MCBs of 'C' series having breaking capacity 10 KA, ISI marked Four pole 40 to 63 Amp complete all as specified and directed.
190Supply only LED tube light batten (1.2 m) 22 Watt complete all as specified and directed.
191Supply only LED tube light batten warm type (Yellow Lumen) 22 Watt complete all as specified and directed.
192Supply only LED (bulb) fixture 18 watt complete all as specified and directed.
193Supply only LED (bulb) fixture 12 watt complete all as specified and directed.
194Supply only LED (bulb) fixture 10/9 watt complete all as specified and directed.
195Supply only LED bulkhead fitting 9 watt complete all as specified and directed.
196Supply only Recessed mounted LED (Ceiling light) luminaire suitable for 2'x2' , 36 watt complete all as specified and directed.
197Supply only Recessed mounted LED (Ceiling light) luminaire suitable for 2'x2' , 36 watt warm type (Yellow Lumen) complete all as specified and directed.
198Supply only Rbber reel with a pair of clAmp, nuts, bolts, split pins etc suitable for ceiling fan down rods complete all as specified and directed.
199Supply only Condensor 1.5 MFD suitable for PVC exhaust fan / wall mounting fan complete all as specified and directed.
200Supply only Condensor 2.5 MFD suitable for ceiling fan / wall mounting fan complete all as specified and directed.
201Supply only Condensor 4 MFD suitable for PVC exhaust fan of any sweep complete all as specified and directed.
202Supply only Ceiling fan blades made of MS sheet duly powder coated complete all as specified and directed.
203Supply only Blade assembly of Exhaust fan with fixing hexagonal nut of size 300/450mm complete all as specified and directed.
204Supply only Down rod of ceiling fan made of Gl pipe medium grade 15 mm bore of length upto 600 mm complete all as specified and directed.
205Supply only Submersible type tullu pump for desert cooler of capacity 1/85 HP, single phase 230 volt 50 Hz copper bound etc complete all as specified and directed.
206Supply only Wooden wool pads including wire mesh suitable up to 5000 cuf/m complete all as specified and directed.
207Supply only PVC pipe of 15 mm dia with water PVC Three way water distributor, heavy duty and PVC elbow complete all as specified and directed.
208Supply only PVC fan blade suitable for desert cooler of capacity up to 5000 cuf/Min complete all as specified and directed.
209Supply only PVC connection of any make with (ISI Mark) having 10mm dia, 45 cm long with steel reinforcement suitable for hot & Cold water complete all as specified and directed.
210Supply only Heating element of geyser 2KW/1.5 KW complete all as specified and directed.
211Supply only Thermostat of geyser 2KW/1.5 KW complete all as specified and directed.
212Supply only Pressure release valve suitrable for 25/50 ltr electric water heater complete all as specified and directed.
213Supply only Apparatus plate of geysers 25/50 litre capacity by brazing not exceeding 5 mm thick complete all as specified and directed.
214Supply only Inner Tank of geyser steel body of capaciy 25/50 Ltrs complete all as specified and directed.
215Supply only PVC flexible pipe inlet 16mm outer dia and 450 mm long for hot/cold water heavy duty with brass nuts & bolts complete all as specified and directed.
216Heating element of solar water heater 300 Ltr 2KW/1.5 KW complete all as specified and directed.
217Supply only Thermostat of solar water heater 300 Ltr 2KW/1.5 KW complete all as specified and directed.
218Supply only Apparatus plate of solar water heater 300 Ltr 25/50 litre complete all as specified and directed.
219Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a soft/Hard soil for laying underground cables/ errection of steel tubular poles / stay pit etc complete all as specified and directed.
220M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed.
221Returning, filling in incl spreading,levelling watering and well ramming in layer n exc .25 cm in soil each layer complete all as specified and directed.
222Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed.
223M & L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class 'B' (old size) bricks laid dry flat, complete all as specified and directed.
224Supply, laying and testing of cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cable heavy duty with standard aluminium conductor, 1100 volts grade, cross sectional area 3.5 core 50 Sqmm complete all as specified and directed..
225All as above Ser item No 208 but 35 Sqmm 4 core
226All as above Ser item No 208 but 25 Sqmm 4 core
227All as above Ser item No 208 but 10 Sqmm 4 core
228All as above Ser item No 208 but 10 Sqmm 2 core
229All as above Ser item No 208 but 6 Sqmm 2 core
230S & F inreplacement of GI tubing 50 mm dia light grade 1.2 mtr long pipe bent to shape 120 degree for mounting of security light and fixed to wall/pole, with suitable MS clAmps 4 Nos with nut and bolt and washers including connecting complete including of suitable length as per direction complete all as specified and directed.
231Supply and fix 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 2.5 Sqmm for electrical connections to the street lights fittings complete all as specified and directed.
232Supply and laying GI Tubing Light grade 40 mm Bore dia as Cable Protection fixied on walls/ poles by using the suitable size clAmps, nuts, bolts etc or laid in trenches complete all as specified and directed.
233Supply and laying GI Tubing Light grade 50 mm Bore dia as Cable Protection fixied on walls/ poles by using the suitable size clAmps, nuts, bolts etc or laid in trenches complete all as specified and directed.
234M & L Dismantling and taking down carefully flood light, street light /perimeter lighting luminaries from its position of any size /wattage from over head line poles or from elevated sentry post for carrying out repair/replacement of burt/worn out accessories and removing unserviceable items frim site and depositing to MES store yard at Reasi, including material and insulated copper conductor single core cable 1.5 Sqmm size, connector block, screws etc. Refixing the fitting after repair to its position complete all as specified and directed. (Note : Contractor responsibility is to liase with the department concerned for LT supply shut down required to carry out the work & aslo ensure the safety of labour emploued by giving them safety wquipments like helmet, gloves safety blt, discharge rod etc and nothing extra shall be permissible in this account.
235Supply and fix Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm complete all as specified and directed.
236Supply and fix Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm complete all as specified and directed.
237Supply and fix Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 16 Sqmm complete all as specified and directed.
238Timer switch with sheet metal enclosure pole mounted type fabricated out of 16 gauge steel sheet consisting of following : - (i) Digital type time swith 24 hours with Power contactor single phase of 65 /TP Amp and MCB of 63 Amp SPN complete all as specified and directed.
239M & L for cleaning, preparing and painting with one coat of aluminium paint to steel tubular pole 9 mtr long complete with cross arms, MS channels, angle, iron, frame work, etc incl numbering of pole with black enameled paint from stencil, complete all as specified and directed.
240Cutting of road not exceeding 100 CM depth for laying of UG Cable incl make good the surface of road with cement plaster mix 1:2 of suitable quantity, complete all as specified and directed.
241S&F in replacement of MCCB 160 Amp, 4 pole 16KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides complete all as specified and directed.
242S&F in replacement of MCCB 25 to 100 Amp, 4 pole 16KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides complete all as specified and directed.
243S&F of 35 W LED Street Light luminaire confirmining incliding all necessary arrangemet for fixing on Pole made up SITC of high quality integrated LED street light with a minimum system lumen of 4500 Lm and system wattage not exceeding 35 W with nominal effiiciency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The housing should be of non- Corrosive high - pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK ratingof 0.7. The luniunaire should have 5 KV internal 10 KV external surge protection in the luminaire. incl takin down old unsv light fittings complete all as specified and directed.
244S&F of 60 W LED Street Light luminaire confirmining incliding all necessary arrangemet for fixing on Pole made up SITC of high quality integrated LED street light with a minimum system lumen of 6600 Lm and system wattage not exceeding 60 W with nominal effiiciency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The housing should be of non- Corrosive high - pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK ratingof 0.7. The luniunaire should have 5 KV internal 10 KV external surge protection in the luminaire. incl takin down old unsv light fittings complete all as specified and directed.
245S&F of 90 W LED Street Light luminaire confirmining incliding all necessary arrangemet for fixing on Pole made up SITC of high quality integrated LED street light with a minimum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal effiiciency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The housing should be of non- Corrosive high - pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK ratingof 0.7. The luniunaire should have 5 KV internal 10 KV external surge protection in the luminaire. incl takin down old unsv light fittings complete all as specified and directed.
246S&F of 70W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture. The luminaire should have a minimum system lumen output of 10800 lumens and 70 Watts. The fixture shall have a CRI of minimym 70. The fixture shall be designed for a system life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lAmp and gear compartement) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operaing voltage rang of 20-277V, surge protection of 10 KV, PF. 0.95, THD<10% inc taking down old unsv light fittings complete all as specified and directed
247S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture. The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimym 70. The fixture shall be designed for a system life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lAmp and gear compartement) and Mechanical impact resistance rating of IK>=07. The fixture driver should have an operaing voltage rang of 20-277V, surge protection of 10 KV, PF. 0.95, THD<10% inc taking down old unsv light fittings complete all as specified and directed
248Supply and Fixing in replacement of old burnt constant current driver suitable for following LED security kight/Flood light fitting of 35 to 60 W capaity complete all as specified and directed.
249Supply and Fixing in replacement of old burnt constant current driver suitable for following LED security kight/Flood light fitting of 72 to 100 W capaity complete all as specified and directed.
250Supply and Fixing in replacement of old burnt constant current driver suitable for following LED security kight/Flood light fitting of 120 to 180 W capaity complete all as specified and directed.
251S & F in repair MCB TPN 63 Amp 415 Volts 50 Hz AC 10 KA with necessary lugs incliding lugs, including taking down existing MCB complete all as specified and directed.
252Supply and fix aluminium lugs of any type / shape of capacity from 10 Sqmm to 25 Sqmm complete all as specified and directed.
253Supply and fix aluminium lugs of any type / shape of capacity from 35 Sqmm to 95 Sqmm complete all as specified and directed.
254Supply and fix aluminium lugs of any type / shape of capacity from 120 Sqmm to 240 Sqmm complete all as specified and directed.
255Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity complete all as specified and directed.
256Material and labour for Outdoor type factory made Bus bar chamber of size 0.45 x 75 x 0.40 M depth made out of CRCA sheet 3.15 mm thick, suitable for 63 Amp Changeover switch 4 pole, 415 volt, 25 KA having locking arrangement, provn of suitable hole at bottom for incoming and outgoing UG cables incl painting with 2 coat of powder coated paint over a coat of red oxide promer on exterior and interior faces of Bus bar chamber, errection of Bus bar chamber with PCC 1:2:4 type B2 and fixing and connection of changeover switch including earth work and provn of suitable frame at bottom made out of angle iron of size 40 x40 x6mm thick complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56240946
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 50 Lakhs
LAST DATE 22-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Drains, Compound Wall, Repair And Desilting, Cleaning/Replacement Of Float Valve Oh Tanks, Repair And Maintenance Of Internal Wiring, Ceiling Fan, Security Light Along With Allied Wks In Sila Grn Under Age Reasi Of Ge Nagrota
Basic Detail
Tender No CANO GEN/TOKEN-49/2026-2027
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 30 Jun 2026
Submission Date 22 Jul 2026
Open Date 27 Jul 2026
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Available
Document List
8a70acc3-cddd-4a3a-aa3e-83f9cbfaa223.html
BOQ_868344.xls
TENDER49.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

8a70acc3-cddd-4a3a-aa3e-83f9cbfaa223.html

xls

BOQ_868344.xls

pdf

TENDER49.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders