Tender For Provision Of Electric Chimney And Water Coolers At Nd Androth Under Ge (Navy) Lakshadweep
Tender Overview
Project Description
Tender for Provision Of Electric Chimney And Water Coolers At Nd Androth Under Ge (Navy) Lakshadweep
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Jul-2026 |
| 2 | 28-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, install and commissioning of wall mounted fully automatic autoclean smart chimney with odour sensor having air flow capacity 1350 m3/ hr , noise level 60 dB, LED lamp - 01 of 1.5 Watt, single phase supply, 240 volts,50 H, with remote control, auto clean alarm, soft light and gesture controlled electro thermal auto clean technoloy complete all as specified and as directed. Make :- FABER / GLEN / HINDWARE |
| 2 | S&F oil filter and oil cap complete all as specified and as directed. |
| 3 | S&F exhaust duct of size 300X300x600mm length made out of 0.6mm thick GI sheet including all supporting materials complete all as specified and as directed . |
| 4 | S&F exhaust duct elbow of size 300X300 made out of 0.6mm thick GI sheet including all supporting materials complete all as specified and as directed . |
| 5 | S&F exhaust duct wiremesh installation made out of 0.6mm thick GI sheet including all supporting materials complete all as specified and as directed . |
| 6 | S&F exhaust duct of size 300X300x600mm length fan box made out of 0.6mm thick GI sheet including all supporting materials complete all as specified and as directed . |
| 7 | Point wiring with PVC insulated unsheathed and multistranded copper conductor cable ISI marked, 1100 volt grade FRLS of size 1.5 Sqmm drawn in concealed suitable PVC rigid conduit with all fittings and accessories, fixing one MS pressed 1.6mm thock modular terminal box woth modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected common earth dolly as specified for one light / fan point controlled by one switch complete all as specified and as directed . |
| 8 | Point wiring with PVC insulated unsheathed and multistranded copper conductor cable ISI marked, 1100 volt grade FRLS of size 2.5 Sqmm drawn in concealed suitable PVC rigid conduit with all fittings and accessories, fixing one MS pressed 1.6mm thock modular terminal box woth modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 2.5 Sqmm as earth wire connected common earth dolly as specified for one 16 Amp socket point controlled by one 16 Amp switch complete all as specified and as directed . |
| 9 | S&F modular switch, 1 way, 6A, 1 module complete all as specified and as directed. |
| 10 | S&F modular switch, 1 way, 16A, 1 module complete all as specified and as directed. |
| 11 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed. |
| 12 | S&F Exhaust fan of sweep 300 mm made of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, RPM 1200, copper winding complete all as specified and as directed . |
| 13 | M&L submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with four single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 sq mm (FRLS) in and including concealed 25mm dia PVC conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old sub main wiring complete all as specified and directed .NOTE: Five runs of 10.0 sqmm cable and one run of PVC conduit shall be paid as one unit . |
| 14 | M&L submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with four single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 4.0 sq mm (FRLS) in and including concealed 20mm dia PVC conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old sub main wiring complete all as specified and directed .NOTE: Five runs of 4.0 sqmm cable and one run of PVC conduit shall be paid as one unit . |
| 15 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V 20 amps complete all as specified and as directed . |
| 16 | S&F in replacement of distribution board VTPN 4 way vertical type double door 415 volts as per IP-43 with provision for MCCB 63 Amps as incomer and SP/SPN/TPN MCB as outgoing and electrically connected up complete all as specified and as directed . |
| 17 | S & F MCCB 63 Amps 16 KA, 4 Pole, 415 V 50 Hz including all connections complete all as specified and as directed . |
| 18 | S& F MCB SPN 32 amps, 240 volts,10 KA 'C' curve complete all as specified and as directed. |
| 19 | S&F MCB SP, 5 to 32 amps, 240 volts,10 KA 'C' curve complete all as specified and as directed. |
| 20 | S&F MCB SP, 40 amps, 240 volts,10 KA 'C' curve complete all as specified and as directed. |
| 21 | Supply & laying CPVC pipes 25mm bore, SDR 13.5 and plain CPVC SDR 11 fittings in trenches complete all as specified and as directed. |
| 22 | S&F Gun metal, globe or gate valves 25mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 23 | Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead 32X6mm by means nut, bolt, check nuts and washer of galvanized iron as earth lead protected by provision of GI light grade pipe 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point including testing complete all as specified and as directed. |
| 24 | Supply, installation, commissioning of Water cooler partialy stainless steel body electric driven,single phase having storage capacity 80 Ltrs and nominal cooling capacity of 40 Ltrs per hour complete all as specified and as directed . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender