Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #56240927

Tender For Repair To Water Supply Distribution Network Including Disinfection Of Water Supply At Various Pump House And Repair To Various Submersible Pump, Booster & Electric Control System At Af Station Chandigarh Under Ge (Af) Chandigarh

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
14 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair To Water Supply Distribution Network Including Disinfection Of Water Supply At Various Pump House And Repair To Various Submersible Pump, Booster & Electric Control System At Af Station Chandigarh Under Ge (Af) Chandigarh

BOQ

Name of Work:- REPAIR TO WATER SUPPLY DISTRIBUTION NETWORK INCLUDING DISINFECTION OF WATER SUPPLY AT VARIOUS PUMP HOUSE AND REPAIR TO VARIOUS SUBMERSIBLE PUMP, BOOSTER & ELECTRIC CONTROL SYSTEM AT AF STATION CHANDIGARH UNDER GE (AF) CHANDIGARH
Sl. No. Item Description
1Excavation in trenches in soft/ loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth for foundation, laying of pipes etc. and getting out complete all as specified and directed.
2Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each soft and loose soil, complete all as specified and directed.
3Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting points complete all as specified and directed.
4Material & Labour for sand cushioning to cables with a layer of sand 8cm deep before laying the cable and 15cm depth after laying & stretching of cable complete all as specified. Note: Punned thickness overall 18cm shall be measured & paid.
5Material & Labour for old size sub class `B` burnt bricks as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed.
6Supply and replacement of sluice valve CI body brass spindle with hand operated iron wheel, both ends flanged and drilled including ring, nuts, bolts, washers & 02 Nos rubber insertion packing, class PN 1.6 conforming to IS 14846-2000 of following sizes complete all as specified and directed.
7150mm bore.
8100mm bore.
980mm bore.
10Supply and replacement of fully automatic star delta starter suitable for 40 HP Non clog submersible electric driven pump set, 3 Phase, AC 415 volt, 50 Hz (for min current carrying cap 62 amps) with MS enclosure with standard protection i.e. single phase, over volt/ under volt etc. complete. Make: BCH/ Siemens/ Schneider.
11Supply and fixing in replacement FASDS suitable for 15 HP Non clog submersible electric driven pump set, 3 Phase, 415 volt, 50 Hz, AC (for minimum current carrying cap 62 amps) with MS enclosure and Std protection i.e. single phase, over volt/ under volt etc. complete all as specified. Make: BCH/ Siemens/ Schneider.
12Supply and replacement PVC insulated, unsheathed copper conductor cable 16 Sqmm, 3 core, flat in shape suitable for submersible pump motor complete all as specified and directed.
13Supply and fixing MCCB, TPN, 100 Amp, 415 volt ,Adjustable type thermal magnetic release breaking capacity 25 KA in and including taking down old unservicable MCCB , complete all as specified and directed by Engrineer-in-Charge. Note for item No 10 & 11 : Make and frame size of the new MCCB should be as per the existing unsv MCCB so that new MCCB can be fixed and connected properly in the panel
14Supply and fixing MCCB, TPN, 160 Amp 415 volt ,Adjustable type thermal magnetic release breaking capacity 25 KA in and including taking down old unservicable MCCB , complete all as specified and directed by Engrineer-in-Charge.
15Supply and fixing Motor protection unit(MPU) three phae 415 volt , 50 HZ ,automatic phase sequence corrector automatically correct inut reverse phase, single phase protection, LV, HV, LIV, Auto of loft, timer, Dry running under & over current, unbalancing ,float switch with built in CTs (Automatic-RTM ) in and including taking down old unservicable Motor protection unit , complete all as specified and directed by Engrineer-in-Charge.
16Supply and fixing Cast iron foot valve of size 80mm dia bore ISI marked with gun metal flapper and high quality pressure stop gasket, nuts, bolts and washers etc complete all as threaded type/flanged type or as per existing sample/ model including providing joints and jointing materials as rubber washers/gaskets with suitable type/ size of bolts and nuts, etc, including dewatering of balancing dirty water from the well chamber in and including taking down old unservicable cast iron foot valve , complete all as specified and directed by Engrineer-in-Charge.
17All as per item No 13 here in before but of size 100 mm bore, complete all as specified and directed by Engrineer-in-Charge.
18Supply and fixing Display board for electric shock treatment chart of size 850x600 mm made out of CRCA sheet 2 mm thick with square pipe 35x35 mm foxed around sheet by welding and making hanging arrangement on top the board. Board shall be painted with two coats of stove enameled paint (Navy Blue) over a coat of red oxide primer and writing the detail with florescent reflective tape (As per sample) by digital computerized printing style , complete all as specified and directed by Engrineer-in-Charge.
19Material & labour for repair to Mono block pumping set upto 1HP, rewinding with existing size of copper conductor wire PVC insulated and repair to pump by replacing the neck rings, motor bush distance sleeves pump coupling stud sealing kit thrust plate and nuts and refixing in same position and testing, complete all as specified and directed by Engrineer-in-Charge.
20Material & labour for repair to dry type motor starter suitable for 30 HP by replacing the following, Power contactor 4 pole 25 Amp 415 volt, overload relay 23to 32 Amp, Electronic timer switch 220 volt to 250 volts , complete all as specified and directed by Engrineer-in-Charge.
21Material & labour for repair to dry type motor starter suitable for 40 HP by replacing the following, Power contactor 4 pole 40 Amp 415 volt, overload relay 26 to 40 Amp, Electronic timer switch 220 volt to 250 volts , complete all as specified and directed by Engrineer-in-Charge.
22Material & labour for repair to dry type motor starter suitable for 15 HP by replacing the following, Power contactor 4 pole 16 Amp 415 volt, overload relay 8.9 to 13.5 Amp, Electronic timer switch 220 volt to 250 volts , complete all as specified and directed by Engrineer-in-Charge.
23Supply and fixing ON Load type changeover switch, 4 pole, 415 volts, 50 HZ AC, of capacity 200 Amps with sheet enclosure in and including taking down old unservicable change over switch , complete all as specified and directed by Engrineer-in-Charge.
24Supply and fixing Spare coil of Power contactor (Existing type) 4 pole, 415 volts and supply and fix new spare coil suitable for MCX-33 Power contactor in and including taking down old unservicable spare coil, complete all as specified and directed by Engrineer-in-Charge.
25Supply and fixing rubber mat 1.0mx2.0mx2.5mm thick duly tested for 11000 volt grade, ISI marked as in replacment, complete all as specified and directed.
26Supply & laying LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 70 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing in and including taking down old unservicable cable , complete all as specified and directed by Engrineer-in-Charge.Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
27Material & labour for repair and servicing of LT panel board by cleaning complete with carbon Tetra chloride solution, replacement of thimbles/ over heated cable pecies/ servicing of starter etc (of pump house installed at different locations) , complete all as specified and directed by Engrineer-in-Charge including carrying out following jobs of renewal :- (a ) Internal wiring of suitable size.(b ) Volt meter 0-500 volt with selector switch -1 No.(c) Amp meter 0-200 A with slector switch and CT of suitable ratio -1 No.
28Supplying, laying, jointing and testing medium grade GI pipe of following sizes inclusive of all fittings such as bends, Tees, unions, elbows, reducers and sockets etc. laid in trenches or fixed to walls and ceilings or laid in floors including taking up or down existing tubing and connections, cleaning for re fixing or removal to store, complete all as specified and directed
2920 mm bore
3025 mm bore
3150 mm bore
3280 mm bore
33100 mm bore
34Cutting existing 20 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc, complete all as specified and directed by Engineer-in-Charge.
35Cutting existing 25 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc, complete all as specified and directed by Engineer-in-Charge.
36Cutting existing 40 to 50 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc, complete all as specified and directed by Engineer-in-Charge.
37Cutting existing 80 to 100 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc, complete all as specified and directed by Engineer-in-Charge.
38Supplying, laying DI pipe 80 mm (certifugally cast) class 'K-9' LA (ISI Mark) in any length with spigot and socket ends as per is 1536-2001 jointed with rubber gasket joint and laid in trenches or in any position in and including taking up or down existing DI/CI pipe and connections, cleaning for refixing or removal to store, complete all as specified and directed by Engineer-in-Charge.Note for item No 30 to 31: Fittings & specials as required shall be provided by the contractor. Contractor's rate shall be deemed to include the cost of fittings provided.
39All as per item No 30 here in before but DI pipe 100 mm (certifugally cast) class 'K-9' (ISI Mark) , complete all as specified and directed by Engrineer-in-Charge.
40All as per item No 30 here in before but DI pipe 150 mm (certifugally cast) class 'K-7' (ISI Mark) , complete all as specified and directed by Engrineer-in-Charge.
41Supply and fixing Mild steel water pipe heavy duty both end flanged as column pipe of 80 mm bore (each length of pipe 3 metre long) in and including taking out existing unserviceable pipe, complete all as specified and directed by Engineer-in-Charge.
42Supply and fixing Gun metal/globe/ gate valve with iron wheel handle screwed at both ends ISI marked suitable for GI pipe including taking down old gate valve of following sizes complete all as specified and directed.
4320 mm bore
4425 mm bore
4540 mm bore
4650 mm bore
47Supply and fixing Cast iron Non return valve of 100 mm dia with provn of two end spoigot and socket suitable for rubber tyton joint and one end flanged fixed with removable MS plate incl ,rubber gas kit,nut,bolt ,washers,and making suitable fixing arrangement to spoigot and sockete DI 200 MM dia pipe etc in and including taking up or down old unservicable CI valve , complete all as specified and directed by Engineer-in-Charge Note : Fitting will be measured and paid separetly, if any, required.
48Supply and fixing Cast iron Non return valve of 150 mm dia with provn of two end spoigot and socket suitable for rubber tyton joint and one end flanged fixed with removable MS plate incl ,rubber gas kit,nut,bolt ,washers,and making suitable fixing arrangement to spoigot and sockete DI 200 MM dia pipe etc in and including taking up or down old unservicable CI valve , complete all as specified and directed by Engineer-in-Charge Note : Fitting will be measured and paid separetly, if any, required.
49Supply and fixing Cast iron Air release valve with two air outlets of 80 mm bore with fixing arrangement in and including taking up or down old unservicable CI Air release , complete all as specified and directed by Engineer-in-Charge
50Supply and fixing Cast iron Air release valve with two air outlets of 100 mm bore with fixing arrangement in and including taking up or down old unservicable CI Air release , complete all as specified and directed by Engineer-in-Charge
51Taking out the sluice valve 80mm dia bore and refacing, regrinding and refixing etc, complete all as specified and directed by Engrineer-in-Charge.
52Taking out the sluice valve 100mm dia bore and refacing, regrinding and refixing etc, complete all as specified and directed by Engrineer-in-Charge.
53Taking out the sluice valve 150mm dia bore and refacing, regrinding and refixing etc, complete all as specified and directed by Engrineer-in-Charge. Please Enable Macros to View BoQ information
54Taking out the sluice valve 150mm dia bore and refacing, regrinding and refixing etc, complete all as specified and directed by Engrineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56240927
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Water Supply Distribution Network Including Disinfection Of Water Supply At Various Pump House And Repair To Various Submersible Pump, Booster & Electric Control System At Af Station Chandigarh Under Ge (Af) Chandigarh
Basic Detail
Tender No GE (AF)/CHD/T-21/2026-27
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 30 Jun 2026
Submission Date 21 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
22142de1-444a-4836-a1a0-3a7f868bd677.html
BOQ_868403.xls
Tender21.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

22142de1-444a-4836-a1a0-3a7f868bd677.html

xls

BOQ_868403.xls

pdf

Tender21.pdf

pdf

Tendernotice_1.pdf