Tender For Repair/Maint Of Fire Fighting, Distribution Network, Pipe Line, Pumps, Panels, Valves And Connectedallied Service At Cod Technical Area Under Ge (I) Kanpur
Tender Value
40 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
19 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Fire Fighting, Distribution Network, Pipe Line, Pumps, Panels, Valves And Connectedallied Service At Cod Technical Area Under Ge (I) Kanpur
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) Kanpur Name of Work : REPAIR/MAINT OF FIRE FIGHTING, DISTRIBUTION NETWORK, PIPE LINE, PUMPS, PANELS, VALVES AND CONNECTEDAllIED SERVICE AT COD TECHNICAL AREA UNDER GE (I) KANPUR Contract No : GE(I)/KAN/T-40 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders areAllowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Items/Works Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide in any type of soil for laying and taking out of GI/CI pipes complete all as specified and directed. |
| 3 | Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 4 | Removing excavated soils to a distance not exceeding 50 m and depositing where directed complete all as specified and directed. |
| 5 | M&L for drilling hole at a depth up to 1.5 mtr below the normal ground level of suitable size to insert upto 250 mm dia pipe across the road in horizontal position only by pneumatic hydraulic drilling machine with compressor complete all as specified and directed. Note Excavation for position the drilling machine and excavation to pass the MS pipe inside horizontal bore wil be measured and paid separately. |
| 6 | Disconnecting and taking up/taking down any type or any size of old MS pipe and cleaning and segregate the serviceable/unserviceable MS pipe for relaying/re-fixing the serviceable pipe and removing of unserviceable pipe from the site including necessary earth work and necessary pipe jointing/welding work any other requirement for connecting pipe and contractor will complete all as specified and directed. Note- Old/ existing pipe line under RCC/ foundation, BLDG or under any permanent infrastructure will not be dismantaled, and same will not be issued under schedule of credit. Also new pipe line has to be diverted as directed by Engr-In-Charge. |
| 7 | Relaying, jointing and testing of serviceable old MS pipe of size 80 mm bore (taking down under srl item No 5) in new or old position including new fittings such as bends, elbows, Tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc. required at site laid in trenches or on floors/road/path etc and making good the disturbed surface to match with existing surface as PCC work in 1:2:4 type B-1 (using 20 mm graded crushed stone aggregated) complete all as specified and directed. |
| 8 | All as per item No 6 above but of size 100 mm complete all as specified and directed. |
| 9 | All as per item No 6 above but of size 150 mm complete all as specified and directed. |
| 10 | All as per item No 6 above but of size 200 mm complete all as specified and directed. |
| 11 | Supply, laying & testing (in replacement) MS pipe ERW steel 80 mm dia heavy duty including welding work and specials as per IS 3589 (1981) and thickness 4.8 mm duly painted with two coats of synthetic enamel paint over and including a coat of zinc chromate primer complete all as specified and directed. |
| 12 | All as per item No 10 above but of size 100 mm complete all as specified and directed. |
| 13 | All as per item No 10 above but of size 150 mm of thickness 6 mm complete all as specified and directed. |
| 14 | All as per item No 10 above but of size 200 mm of thickness 6 mm complete all as specified and directed. |
| 15 | All as per item No 10 above but of size 250 mm of thickness 6 mm complete all as specified and directed. |
| 16 | All as per item No 10 above but of size 300 mm of thickness 6 mm complete all as specified and directed.Note for Item No 10 to 15: The Existing Pipe line passing through existing building foundation, Hard standing or any other area, where excavation is not possible to replace the leakages of pipe line are to be diverted with new pipe line as directed by Engr-In-Charge and Schedule of Credit for diverted line wil not be issued. |
| 17 | Supply and laying bitumen membrane of 4.0 mm thickness (coating/ wrapping) over a 80 mm MS pipe, including rubbing cleaning & painting/ applying bituminous primer solution before laying bitumen wrapping layer. Inner wrap (Coating/ wrapping) of bitumen must consist of inorganic or polymer fiberglass cloth & outer wrap must have to be tough layer of protective tape or material to protect against mechanical damage from soil or environment factor, bitumen wrap to be laidAll around the pipe and heated upto 215 to 2400C for proper sticking of bitumen wrap over MS pipe complete all as specified and directed. |
| 18 | All as per item No 16 above but of size 100 mm complete all as specified and directed. |
| 19 | All as per item No 16 above but of size 150 mm complete all as specified and directed. |
| 20 | All as per item No 16 above but of size 200 mm complete all as specified and directed. |
| 21 | All as per item No 16 above but of size 250 mm complete all as specified and directed. |
| 22 | M&L for construction of fly ash brick masonry valve pit chamber of size 950 mm X 950 mm X 950 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded onAll four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE) including two coat of approved synthetic enamel paint over and including one coat of red oxide primer on prepared steel surface complete all as specified and directed and old retrieved MS frame and MS sheet shall be deposited to MES sore yard. |
| 23 | S&F in replacement of cast iron double flanged sluice valve of size 80mm bore class PN 1.6 confirming to IS 14846/2000 with with high tensile stainless steel spindle with CI wheel, Gun Metal Nuts/rings 'I' bolt, ISI marked including replacement of rubber packing complete all as specified and directed. Make : Kirloskar/Upadhyay/BIR |
| 24 | All as per item No 22 above but sluice valve of size 100mm complete all as specified and directed. |
| 25 | All as per item No 22 above but sluice valve of size 150mm complete all as specified and directed. |
| 26 | All as per item No 22 above but sluice valve of size 200mm complete all as specified and directed. |
| 27 | All as per item No 22 above but sluice valve of size 250mm complete all as specified and directed. |
| 28 | All as per item No 22 above but sluice valve of size 300mm complete all as specified and directed. |
| 29 | Taking down gun metal gate valves of any type and size upto 80 mm bore complete all as specified and directed. |
| 30 | S&F gun metal iron gate valve 25 mm dia with iron wheel head, screwed both ends for iron pipe, ISI marked, complete all as specified including dismantling the old unserviceable existing valve complete all as specified and directed. |
| 31 | All as per item No 29 above but of size 40 mm bore complete all as specified and directed. |
| 32 | All as per item No 29 above but of size 50 mm bore complete all as specified and directed. |
| 33 | All as per item No 29 above but of size 80 mm bore complete all as specified and directed. |
| 34 | Supply and fixing in replacment of Non Return valve of 80 mm dia both end flanged suitable for cast iron including all fittings washer, nuts & bolts etc complete all as specified and directed. |
| 35 | All as per item No 33 above but of size 100 mm bore complete all as specified and directed. |
| 36 | All as per item No 33 above but of size 150 mm bore complete all as specified and directed. |
| 37 | All as per item No 33 above but of size 200 mm bore complete all as specified and directed. |
| 38 | M&L for cleaning of semi under ground reservoir up to 1000000 gallons capacity at staging including removal ofAll deposited scales, dirt and settled sand particals from intake of circulating pipe, cleaning with brushing, sweeping and brooming of inner and outer wall of the tank and washing the complete with bleaching powder solution and M&L for painting to rising main, delivery pipe, wash out and over flow pipes of 150mm bore existing water mains with two coats of synthetic enamle paints and also re-writing date of cleaning and marking of rising & delivery mains etc.Note : 1. The work shall be carried out through only by trained staff with hygiene and safety equipments 2. Responsibility for insurance and safety of team will solely rest with the contractor. 3. Cost of temporary supports such as props, jacks, scaffolding etc as required at site is deemed to be included in unit rates quoted. |
| 39 | M&L for replacement of MS angle iron/Channel support for motor/pump incl nut bolt etc incl painting and making good all disturbed surfaces with PCC 1:2:4 complete all as specified and directed. |
| 40 | Supply and fixing in replacement fire hydrant landing valve type ‘A’ (single head outlet) of 63 mm dia of size confirming to IS 5290 complete all as specified and directed. |
| 41 | Supply and fixing in replacement Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard for housing 2 Nos X (Rubber Reinforced fire hose reel) 63 mm dia 15 mtrs length, branch pipe, nozzle, coupling extra of MS sheet of thickness 2 mm complete all as specified and directed. |
| 42 | Supply and fixing in replacement Hose box made of 18 gauge MS Sheet 1110mm X 820mm X 600mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard for keeping 01 No fire hydrant fire hose reel drum set with rubber hose pipe of 30 mtrs, branch pipe, nozzle, coupling extra of MS sheet of thickness 2 mm alongwith providing angle iron frame stand to mount Hose box including PCC work & excavation complete all as specified and directed. |
| 43 | Supply and fixing in replacement 63 mm dia gun metal branch pipe with 12.5/15 mm nozzle conforming to IS 903 complete all as specified and directed. |
| 44 | Supply and fixing in replacment of fire hydrant fire hose reel drum set with rubber hose pipe of 30 mtrs length/ 20 mm confirming IS 884/ 1985 rolled in drum including brass shutoff nozzle complete control valve, mounting brackets, nuts & bolts etc complete all as specified and directed. |
| 45 | Supply anf fixing in replacment of fire hydrant white colour hose reel (Rubber Reinforced fire hose reel) 63 mm dia 15 mtrs length with stainless steel coupling fixed at both side ends complete all as specified and directed. |
| 46 | M&L for cement concrete 1:4:8 type C-2 (using 40 mm grade stone aggregates) as in foundation, filling and mass concrete including sub base of floors complete all as specified & directed. |
| 47 | M&L for mock drill, trial, testing and checking/ identifying any leakage in pipe lines of complete firefighting system (Booster Pump House). Details of testing & trails is as follows ;-(a) Operation/ Opening & closing of all 300/200/ 150/ 100 mm sluice valve.(b) Operation of diesel driven 150 HP pump, electric driven 150 HP pump & 20 HP Jockey pump during testing & trial.(c) Inspection of all the fire hydrants for proper operation of fire hydrant handle wheels for opening & closing and also for availability of water in each hydrant with proper pressure. Incase of any leakages, no water avl or low water pressure and non-operation of fire hydrant noticed, to be reported to JE & Engr-In-Charge.(d) Checking/ inspection of leakages in 80 mm, 100 mm, 150 mm, 200 mm, 250 mm & 300 mm MS pipe, connected with Booster pump house & spreadAll over for 6-7 KM in COD Kanpur dept area, laid in open & buried in earth. Any leakages find to be intimated to JE & Engr-In-Charge.(e) During mock drill of firefighting, transporting & fixing of hose reel with fire hydrant, opening of 30 mtrs rubber hose reel drum from MS housing safely for operation and also cleaning & re-fix the same after the mock drill. (f) To execute above mentioned task during mock drill of firefighting, contractor has to provide 05 personnel, whom are aware of plumbing work & firefighting systems. Contractor has to provide transportation & communication system to his team during the testing and mock drill for proper operation of pumps and identification of leakage in pipe line, sluice valve and hydrants. Note:- Contractor has to carryout above mentioned mock drill for firefighting in every 15 day (02 times in a month) or when every directed by JE & Engr-In-Charge |
| 48 | Repair/ servicing to complete diesel driven pump set any make/model 150 HP of any make water cooled diesel engine by taking out dismantling segregation ofAll parts and re-assembling after duly repair/replacement/ servicing of following new part fixing includingAll type machine work such as turning reaming etc washing cleaning, greasing, wires, gaskets, V belts, rubber hoses, cleaning of engine externly by vacuum cleaner and greasing of bearing, replacement of engine oil, flexible coupling &All type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note: Any other accesories found unserviceable that shall be replaced & paid under respective items of the Schedule complete all as specified and directed. |
| 49 | S&F in replacement of Lub oil filter element for 150 HP pump set as per sample complete all as specified and directed. |
| 50 | S&F in replacement of Fuel filter element for 150 HP pump set as per sample complete all as specified and directed. |
| 51 | S&F in replacement of dry type air cleaner for 150 HP pump set as per sample complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 days