Tender for Repair / Maintenance Of External Electrification Work Required For Oh Line, Cable, Vcb, Transformers, Solar Street Light Poles And Its Work At Nai, Nofra & 30 M Under Ge(P) No-1 Jabalpur.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling carefully the existing Un-serviceable LT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor complete all as specified and directed. |
| 2 | Supply and stringing, stretching and fixing ACSR conductor for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size complete all as specified and directed. |
| 3 | Fixing only/stringing only old dismantled ACSR conductor for over head line securing on pole complete including binding wire, etc of any size complete all as specified and as directed.Note for item Srl No 2 & 3 : Jumper on cut point/2 pole structure/4 pole structure shall be provided with PVC insulated sleeves. Rates shall be included of jumper and tree branch cutting to make safe distance from pole /OH line. complete all as specified and directed. |
| 4 | Dismantling/taking down of insulators of any type/size from HT/LT poles/DOs/GODs complete all as specified and directed. |
| 5 | Dismantling of existing old cross arms etc made of mild steel channel, angle iron, flat iron, back plates, nuts, bolts, washers etc complete all as specified and directed. |
| 6 | S&F in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for 11000 volts grade complete all as specified and directed. |
| 7 | S&F in repair Disc type insulator, porcelain, vitreous, 145 mm high and 255 mm dia, ball & socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed. |
| 8 | ~ditto~ all as per item No 7 here in before but 100 mm height, 65 mm dia for 1100 Volts grade complete all as specified and directed. |
| 9 | S&F in repair Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps 31 x 3 mm, washers, insulator bolts and washers and nut of height 75 mm and 90 mm dia for working pressure 1100 Volts complete all as specified and directed. |
| 10 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural mild steel sections conforming to Fe-410-0 grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfacescomplete all as specified and directed. |
| 11 | S&F in repair Switch air break, gang operated, out door type, triple pole, HT 11000 volts, 200 Amps, vertical type with 3 insulators mounted with fixed contacts of phospor bronze and moving contacts of copper, manually operated from ground level with operating mechanism including mild steel galvanised light grade 25mm bore operating rod, pad locking arrangement, complete all as specified and directed. |
| 12 | S&F in repair Drop out expulsion fuse assembly with fuse carrier, triple pole HT 11000 Volts, 200 Amps, out door type (having two Nos post insulators mounted on MS Channel for each pole ) complete all as specified and directed. |
| 13 | S&F in replacement of lightening arrestors Expulsion type complete with all fitting, transmission class, discharge capacity upto 65 kilo Amps suitable for 11k Volts and connecting to earth wire complete all as directed including taking down the u/s bursted lightning arrestors from OH structure complete all as specified and directed. |
| 14 | M&L for Out door cable end jointing kit (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (earthed) grade, of cross sectional area 120 to 150 Sqmm 3 core. (Note: Taking out of existing cable, cutting faulty ends if required, are deemed to be included in the item rate quoted) complete all as specified and directed. |
| 15 | Supply & Fixing in repairs Danger notice plate for LT, 20 x 15cm x 1.60 mm thick, mild steel sheet, vitreous, enamelled white, with letters, figures and conventional skull & bones in single red colour and fixed on LT Panel using suitable nuts, bolts and washers of required size complete all as specified and directed. |
| 16 | Supply only Electrical Rubber hand gloves as per ISI specification for operating voltage 11 KV complete all as specified and directed. |
| 17 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. including taking out old U/S mats and remove from site complete all as specified and directed. |
| 18 | Supply only 20 feet bamboo ladder, width 1 feet, step gap 10 inch, complete all as specified and directed. |
| 19 | M&L for Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified and directed. |
| 20 | Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. |
| 21 | Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. |
| 22 | M&L for cushioning for protection of cable using dry river sand or M Sand, free from particles complete all as specified and directed. |
| 23 | Supplying and laying Un-reinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 24 | M&L for Cutting the existing hard standing/road and making good after laying of cable/pipe with 100mm thick PCC 1:2:4 mix, type B-I including finishing to match existing surfaces complete all as specified and directed. |
| 25 | Taking out old unserviceable, burnt, punctured aluminium conductor cable of any grade and cross sectional area from the excavated trenches, ducts, laid in floors, along poles/ walls/ equipments etc., laid and passed through pipes or laid bare in road crossing/drains/ paths/along walls/poles/floors etc and in similar locations complete all as specified and directed. |
| 26 | Supply, laying and testing in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area complete all as specified and directed. |
| 27 | (a) 70 Sqmm 3.5 core |
| 28 | (b) 50 Sqmm 3.5 core |
| 29 | (c) 25 Sqmm 3.5 core |
| 30 | (c) 16 Sqmm 4 core |
| 31 | (c) 10 Sqmm 4 core |
| 32 | (d) 10 Sqmm 2 core |
| 33 | Taking out old unserviceable, GI tubing of any size upto 80 mm bore from the excavated trenches, ducts, floors, along poles/ walls/ equipments, road crossing/drains/ paths etc complete all as specified and directed. |
| 34 | Supply and laying in trenches/under roads/crossings or fixed to wall/pole/roof, GI tubing light grade of following sizes for protection of UG cables :- Note : Payment for excavation, earth work, PCC shall be paid for separately under relevant items of Schedule.complete all as specified and directed. |
| 35 | (a) 80 mm dia |
| 36 | (b) 50 mm dia |
| 37 | (c) 40 mm dia |
| 38 | Disconnecting all cable connections and taking out u/s MCCB/MCBs any type/capacity upto 400 Amps, TP/FP/TPN, 415 Volt from Panel Boards/feeder boxes and remove from site. complete all as specified and directed. |
| 39 | Supply & Fixing MCCB, 4 Pole, 250 Amps, with thermal release, 415 Volt, 36 KA, including connecting up using suitable size of lugs. complete all as specified and directed. |
| 40 | Supply & Fixing MCCB, 4 Pole, 200 Amps, with thermal release, 415 Volt, 36 KA, including connecting up using suitable size of lugs. complete all as specified and directed. |
| 41 | Supply & Fixing MCCB, 4 Pole, 160 Amps, with thermal release, 415 Volt, 25 KA, including connecting up using suitable size of lugs. complete all as specified and directed. |
| 42 | Supply & Fixing MCCB, 4 Pole, 100 Amps, with thermal release 415 Volt, 16 KA including connecting up using suitable size of lugs.complete all as specified and directed. |
| 43 | Supply & Fixing MCCB, 4 Pole, 63 Amps, with thermal release 415 Volt, 16 KA including connecting up using suitable size of lugs. complete all as specified and directed. |
| 44 | Supply and fix in repairs road lighting luminaires, 70 watts, min 120 lm/watt,230 Volt high power LED with unique peanut lens for uniform distribution, IP-65/66 class of protection & incl SPD, higher spacing between poles, fixing it in new bracket (painting the bracket with one coat of red oxide and one coat of aluminum paint) and connecting it with pole mounted junction box with 2.5 sqmm 3 core copper conductor complete all as specified and directed. |
| 45 | Supply and fix in repairs road lighting luminaires, 90 watts, min 120 lm/watt 230 Volt high power LED with unique peanut lens for uniform distribution, IP-65/66 class of protection & incl SPD higher spacing between poles, fixing it in new bracket (painting the bracket with one coat of red oxide and one coat of aluminum paint) and connecting it with pole mounted junction box with 2.5 sqmm 3 core copper conductor complete all as specified and directed. |
| 46 | Supply and fixing in repairs on Pole/Wall Flood light fittings for use with LED lamps, 170 watts with min 120 lm/watt, 230 Volt,with unique peanut lens for uniform distribution & reflector, with toughened glass cover, IP-65/66 class of protection, & incl SPD complete with control gear and all accessories. complete all as specified and directed. |
| 47 | Supply and fixing in repairs on Pole/Wall Flood light fittings for use with LED lamps, 120 watts,with min 120 lm/watt , 230 Volt, with unique peanut lens & reflector, with toughened glass cover, IP-65/66 class of protection, & incl SPD complete with control gear and all accessories. complete all as specified and directed. |
| 48 | M&L for Preparing old painted surfaces of HT/LT Steel tubular poles including cross arms, back plates, bracings, all exposed surfaces of steel items fixed with the pole, without dismantling and M&L for painting with two coats of aluminium paint complete all as specified and directed. |
| 49 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI strip of size 25mm x 3mm from earth plate to body of the equipment by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate(6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.complete all as specified and directed. |
| 50 | M&L for Repairing of earthing including PCC pit cover ,GI funnel,PCC work of pit ,necessary fixing arrangements like clamps bolts for earthing conductor to be fixed properly in its place and testing of earthing with earthing tester of proper calibration and painting the earthing resistance results on wall and pit cover complete all as specified and directed. |
| 51 | S&F in repair earth continuity conductor or main earth lead of aluminium strip 25 x 3 mm with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as specified and directed. |
| 52 | M&L for PCC type B-1 (1:2:4) 20 mm graded stone aggregate to fix angle post including fomwork etc. complete all as specified and directed. |
| 53 | M&L for repair/maintenance to LT panels, cleaning of panel, welding of joints if any, replacing damaged, bolts and nuts, painiting with one coat of primer and one coat of smoke gray paint, disconnecting all lugs from bus bar, cleaning and removing any scales with sand paper,reconnecting all the connections complete all as specified and directed. |
| 54 | Taking down u/s street light/flood light/garden lights/Post top lantern fittings for use with LED lamps of capacity upto 200 watts complete with all accessories and keep the serviceable fittings in safe custody for reuse and remove the unserviceable fiitings from site. complete all as specified and directed. |
| 55 | Supply & fixing in replacement, Brackets for street light fittings made out of 40 mm bore Light grade GI pipe, 1.5 Mtr length, bend to shape, including necessary Clamps made out of MS flat iron, nuts and bolts suitable for fixing with steel tubular/PCC Poles complete all as specified and directed. |
| 56 | M&L for wiring of street light with three core, multi stranded, PVC insulated, 1100 Volt grade, FRLS, cable with copper conductor of size 2.5 Sq mm in and including/drawing through junction to street light with flexible pvc conduit complete all as specified and directed. |
| 57 | S & F in repairs Weather proof street light /pole light junction box made of FRP material of size suitable for 10 to 16 sqmm cable depth including one MCB, SP, 6 Amps and connecting terminals including necessary Clamps made out of MS flat iron, nuts and bolts suitable for fixing with steel tubular Poles complete all as specified and directed. |
| 58 | Supply and fixing post top lantern LED type 40/45 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65/66 protection with impact and corrosion resistant complete with driver and lamp complete., duly errected on ground/wall in 40/50 mm GI pipe, with Cable entries for through-wiring of mains supply cable, suitable for operation on 240V, 50Hz single phase ac supply complete all as specified and directed.(Note : GI pipe if required will be measured and paid separately). |
| 59 | Supply and fixing in repairs of LED Street light by taking down the street light from the pole including cleaning, changing the clamps , nut bolts ,and replacing the electronic driver of specified LED Light fittings upto 200 watt make as per site requirement complete all as specifed and directed. |
| 60 | Supply and Fixing in repairs, LED bollard light in cylindrical shape with acrylic diffuser and IP66 protection 9/10 watts LED, 3000K, 230 Volt, duly errected on ground, with Cable entries for through-wiring of mains supply cable,IK 07 Suitable for operation on 240V, 50Hz single phase ac supply complete all as specified and directed.Note: Rate are inclusive of fixing of GI pipe using P:C:C (1:2:4) work and taking out old Fittings complete as directed. |
| 61 | Supply and Laying DWC (HDPE) pipe of 50/80 mm for the protection of HT/LT cable from external damage complete all as specified and directed. |
| 62 | M&L for Repair to transformer after disconnecting in coming HT connection and out going LT cable connection, draining out the transformer oil and keep in safe custody for reuse, disconnecting the breather assembly, temperature gauge, taking out the top cover of transformer upto 630 KVA, indoor/outdoor type, 11KV/433 Volt, step down, disconnecting LT/HT winding connections from LT/HT Bushing and carefully taking out LT/HT Bushing insulator and HT/LT Brass spindle, taking out gaskets of LT/HT Bushings and transformer top cover. Refixing exisitng LT/HT Brass spindle with Bushing insulators after replacing Gaskets, View glass of conservator tank, refixing all cable connections, top cover with new gasket, breather/temp gauge, refilling transformer oil, complete all as specified and directed.Note: Transformer oil for topup, dehydration/filtration etc work will be measured and paid separately. |
| 63 | Supply and filling in Transformers, Transformer oil of dielectric strength not less than 40 KV, conforming to IS-335 Make: Transol,Power oil complete all as specified and directed. |
| 64 | Dehydration/Filtration of Transformer oils of Transformer/Switch gears using oil filtration plant for removing the moisture contents and corbon deposits from the oil and bringing it to the dielectric strength not less than 40 KV complete all as specified and directed. |
| 65 | Supply & fixing breather assembly suitable for outdoor type trasformer with silica gel including taking down u/s from the transformer complete all as specified and directed. |
| 66 | S & F in repair porcelain HT bushing vitreous, brown colour, 11 KV grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing HT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for primary side (HT side ) of outdoor type 11 KV upto 400 kVA distribution transformer of any make complete all as specified and directed. |
| 67 | S & F in repair porcelain LT bushing vitreous, brown colour, 440 V grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing LT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for Secondary side (LT side ) of outdoor type 440V upto 400 kVA distribution transformer of any make complete all as specified and directed. Please Enable Macros to View BoQ information |
| 68 | S & F in repair porcelain LT bushing vitreous, brown colour, 440 V grade along with a set of oil seals & copper alloy stud, nuts, washers etc. including dismantling existing LT bushing with copper alloy rod and disconnection of electrical connection, of suitable size for Secondary side (LT side ) of outdoor type 440V upto 400 kVA distribution transformer of any make complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender