Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56240882

Tender For Repair/ Rewinding Of Certain Transformers Vcbs/ Servo Stabilizer Under Ge (Army) Dhar Road Udh Ur

Issued by Statutory Bodies & Commissions/Committees · Reasi, Jammu and Kashmir
Tender Value
35 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
17 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/ Rewinding Of Certain Transformers Vcbs/ Servo Stabilizer Under Ge (Army) Dhar Road Udh Ur

BOQ

Name of Work:- REPAIR/ REWINDING OF CERTAIN TRANSFORMERS VCBS/ SERVO STABILIZER UNDER GE (ARMY) DHAR ROAD UDH UR
Sl. No. Item Description
1BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR/ REWINDING OF CERTAIN TRANSFORMERS VCB'S/ SERVO STABILIZER UNDER GE (ARMY) DHAR ROAD UDHAMPUR Contract No: CWE/U(DR)- 49/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Labour and necessary T&P for disconnecting defective out door/indoor transformers of capacity upto 400 KVA from HT/LT side after taking proper shutdown,disconnecting body and neutral earth connections and taking out complete transformer oil, storing the same in dried containers (to be arranged by the contractor) opening the top cover and lifting the core assembly by means of tripod and chain pulley block carefully to check its condition, refilling the transformer oil after complete dehydration/filtration if required (to be paid separately) and necessary repairs including replacement of worn out nuts, bolts & washers etc, fixing the top cover after housing back entire core & coil assembly and fixing the top cover thereafter complete all as specified and directed by Engineer-in-Charge.Note : (a) Lowering and taking down the same from two /four pole structure / PCC platform to ground & loading on vehicle carefully with the help of telescopic boom crane, steel ropes & winches etc.Unit rate of item shall deemed to be included. (b) In case of major repairs/replacement in transformer which can not be undertaken at site the transformer shall be shifted at civil workshop and the cost shall be paid separately under relevant items.(c) Cost of dehydration/filteration and other necessary repairs shall be measured and paid separately under relevant item. Contractor shall bring the mechanic at site for first inspection of the transformer after that transformer shall be shifted at workshop complete all as directed by Engineer-in-Charge.
3Labour, T&P & vehicle for transporting (To & From) the defective transformer for repair to civil workshop, opening top cover of transformer for repair and taking out the burnt HT/LT coil (windings), dismantling HT/LT coils from core & reassembling the core after replacement of burnt HT/LT coils of existing gauge & turns,housing Core & coil assembly with all accessories in transformer body and connecting up to HT/LT bushings, filling in dehydrated transformer oil, testing complete, transporting back the transformer to location/site and reconnecting HT /LT/Earth connections at existing electrical system including testing & commissioning complete on load of following capacities.Note : Following items / spares required to be replaced shall be measured and paid separately (a) Transformer oil (b) Winding of LT/HT Coils (c) Silica Gel/Silica Gel Pot (d) Porcelain bushings / brass studs. (A) 25 KVA to 200 KVA
4All as per item No 02 herein before but capacity 250 KVA to 400 KVA
5M&L for rewinding of HT/LT coils of transformer as per following specifications including de-moisturizing the prepared coils in heat chambers for adequate duration before assembling the winding and core with double paper insulation for reconditioning only of existing copper strip for LV (0.433 KV) winding having existing size / gauge including necessaory testing in workshop and connection of tap changer after dismantling unserviceable winding wire complete all as specified and as directed by Engineer-in-Charge.(A) Super enameled double paper insulated copper wire for HV (11 KV) winding having existing size / gauge
6Shifting of transformer of following capacities in between locations as mentioned against each Dhar Road Garrison Engineer or 16 Corp Power House and back by transportation in safe custody incl loading and unloading from foundation complete all as specified and directed by Engineer-in-Charge.Note :- Rate for hiring of crane/vehicle are deemed to be inculded in quoted rates.(A) 25 KVA to 200 KVA in between Dhar Road Cantt area or 16 Corps and back.
7All as per item No 05 here in before but capacity 250 KVA to 400 KVA in between Dhar Road Cantt area or 16 Corps and back.
8De-hydration / filtration of transformer oil by hiring on line filtration plant to achieve di-electric strength not less than minimum 60 KV including following work services :- (a) Removal of all suspended particles such as dust, rust, scales, colloid solution of carbon particles sludge etc upto < 1 micron. (b) De-hydration of transformer oil under vaccum. (c) Circulation of heated oil and filling of treated oil in transformer tank. (d) Top up the transformer oil upto the level marked in breather tank.NOTE : (i) Contractor shall use the vehicle mounted filtration plant with suitable size heavy duty hose pipe. (ii) The transformer oil required for replacing/top up shall be measured and paid separately under relevant item of the schedule.(iii) Conducting field testing of di-electric strength of the transformer oil before and after filtration. (iv) Checking the megger / earth resistance values with battery operated megger of 5 KV.(v) Test report for BDV of oil shall be submitted by agency / contractor carrying out filtration.
9M&L in replacement for filling / topping of new transformer oil after heating and having di electric strength not less than 60 KV complete all as specified and directed by the Engineer-in-Charge.Note : The transformer oil shall be supplied in sealed barrels of 210 Ltr capacity each of approved make duly marked with IS-335 on barrel. The barrel will be checked in presence of JE, Engineer-in-Charge and contractor for soundness of seal. Test report and purchase voucher shall be brought and produced by contractor before incorporation in work and the copy of the same shall be kept on record duly defaced by the Engineer-in-Charge.
10Supply and filling in existing breather by replacing new silica gel of superior quality for air breather of transformer complete all as specified and as directed by the Engineer-in-Charge.
11S&F in replacement of breather assembly of Transformer incl silica gel upto 250 KVA transformer as per existing make and type 500 Gm complete all as specified and directed by the Engineer-in-Charge.
12S&F in replacement of breather assembly of Transformer incl silica gel 300 KVA to 500 KVA transformer as per existing make and type 1 Kg complete all as specified and directed by the Engineer-in-Charge.
13S&F in replacement of brass terminal stud existing size with nuts, check nut, oil seal and washer for HV side of transformer up to 100 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
14All as per item No 12 here in before but capacity 150 KVA to 250 KVA transformer complete all as specified and as directedby the Engineer-in-Charge.
15All as per item No 12 here in before but capacity 300 KVA to 400 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
16S&F brass terminal stud of existing size with nuts, check nut, oil seal and washer for LV side of transformer of any make (as per sample) up to 100 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
17All as per item No 15 herein before but capacity 150 KVA to 250 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
18All as per item No 15 here in before but capacity 300 KVA to 400 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
19S&F in replacement of bushing of HV side as per existing size/Model of the capacity up to 250 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
20All as per item No 18 here in before but capacity 300 KVA to 400 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
21S&F in replacement of bushing of LV side as per existing size/Model of the capacity up to 250 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
22All as per item No 20 herein before but capacity 300 KVA to 400 KVA transformer complete all as specified and as directed by the Engineer-in-Charge.
23M&L for painting of transformers capacity up to 100 KVA including HV/LV connection box with one coat of synthetic enamel paint by using spray painting method including cleaning of all dirt and greasy materials from existing surface alongwith marking of SM/MES Nos with black synthetic enamal paint n. exc 2 cm height at appropriate places after isolating the transformer from the electric supply complete all as specified and as directed by the Engineer-in-Charge.
24All as per item No 22 herein before but capacity 150 to 250 KVA
25All as per item No 22 herein before but capacity 300 to 400 KVA
26M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe Light grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe light grade for watering with alternate layers of charcoal / coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electrical plate No. 3 of SSR Part-I and testing of earth resistance as required complete incl removing of old one all as specified and directed by Engineer-in-Charge.
27M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron strip 32 x 6mm as earthing lead protected by GI pipe light grade 40mm bore for protection of GI earth strip and 20 mm dia GI pipe light grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to Transformer/Panel incl removing old one compete all as specified as shown in electricall plate No. 3 of SSR Part-I and testing of earth resistance as required.
28S&F in replacement of Galvanised iron strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and as directed by the Engineer-in-Charge.
29M&L for painting to steel surface over 10 cm width or girth of any description, new or previously untreated surface with two coats of aluminium paint over a coat of red oxide primer complete all as directed by Engr-in- Charge.
30Supply and laying in replacement of 25mm to 63 mm nominal size Graded coarse aggregate and aggregate shall be measured net, in compact stacks,prepared on level ground complete all as specifed and directed by the Engineer-in-Charge.
31M&L in replacement of constructing Earth pit of internal size not less than 300x300x150mm PCC 1:3:6 type C 1 chamber, RCC cover slab of 50 mm thick 1:2:4 with suitable handle including Dismantling old unsv one.
32Inspection, preventive maintenance, repair and testing of 11 KV VCB/OCB Panel with breaker as under :- (a) Cleaning of all chambers in panel like breaker, Bus bar, Spout etc by CRC. (b) Tightness, cleaning of all hardwares in all chambers (c) Greasing of all mechanical interlocks and breaker mechanism, movable parts. (d) Applying Jelly in isolating contact, spout connections (e) Rack in - Rack out operation and setting. (f) Setting of wheel assembly of breakers. (g) ON/OFF & Snatch gap setting. (h) Tripping test in overload and earth fault position by external current injecting Kit on both primary & secondary sides (j) Meggar testing between phase to phase and phase to earth in ON / OFF position both complete all as specified and directed by Engineer-in-Charge.Note :- Inspection, maint, repair and testing of VCB/OCV rates are included in the same item. minor items such as Small nut,bolt, washer, wiring adjustment and minor parts are deemed to be inculded in the above quoted rate.Major Spare parts for VCB to be measured and paid separately as supply only items. Make as per existing at site.Supply of spares for HT VCB / OCB are as follows:-
33(A) INDICATIONS
34S&F in replacement of Indication lamp LED (RED/Green/Amber/White/Clear/Blue)
35(B) CIRCUIT BREAKER COIL/PLUG & SOCKET/HANDLE
36S&F in replacement of Closing/making coil 24/30V DC
37S&F in replacement ofShunt trip coil 24/30V DC
38S&F in replacement of Series trip coil 24/30V DC
39(C) ACCESSORIES
40S&F in replacement of Spacer Heater as per existing cap and type
41S&F in replacement of Thermostate 30-90 Deg all as per existing cap and type.
42S&F in replacement of NO/NC Contacts All as per existing capacity and type.
43S&F in replacement of Master trip relay All as per existing capacity and type.
44S&F in replacement of Motor and gear assy 220V AC/DC all as per existing capacity and type.
45S&F in replacement of Auxiliary switch with NO & NC Contacts all as per existing capacity and type.
46Supply, installation, testing and commissioning in replacement of 11KV Current Transformer with Indoor & Resin cast type single pole of following capacities CTR-100-50/5 + 5A, STR - 25 kA for 1 Sec, Core 1 - 15VA/CL1.0, Core 2 - 15VA/5P10 fixing on existing 11 KV panel including necessary connections, any modification required, addition / alteration required for fixing CT in existing 11 KV panel incl taking down old one complete all as specified and directed by the Engineer-in-Charge.
47All as item no 45 above but of ratio 50-25/5 + 5A complete all as specified and directed by the Engineer-in-Charge.
48S&F in replacement of unsv over current protection relay with existing type,model and make design to show Power, Alarm, Trip and Error on the screen or equivalent as per existing make and type including removing of old UNSV relay and making connection of new relay including necessary calibration through secondary injection to match with the present system. including testing all parameters complete all as specified and directed by the Engineer-in-Charge.
49S&F in replacement of Calibration of digital/IDMT protective relays of HT panel (OCB/VCB's) as per load pattern, by preparing data sheet of existing electric load from each sub stations, re-programming input data into relays (OCHS, EFHS, OCLS, EFLS, CTR, TDS etc) complete testing by injecting current in CT primary and measure secondary current at 11 KV, control and relay panel for metering, protection relay plug settings intended in service through current injection in CT primary and ratio including complete polarity test complete all as specified and directed by the Engineer-in-Charge.Note : Calibration shall be performed by either rep of OEM or qualified engineers.
50S&F of auxiliary power supply/ battery bank with panel made of 2mm CRCA sheet complete with maintenance free lead acid battery bank mounted on MS rack and provide with connector etc complete in all respect with install capacity 24 Volts, DC 12 Nos each of 2 Volts 150AH including booster battery charger 24 volt all as per standard specification complete with DC Amps Meter, Volt meter incl taking out old unserviceable, switches ON/OFF, TRICKLE/BOOSTER complete all as specified and directed by Engineer-in-Charge.
51Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
52All as per item No. 50 above but depth exceeding 1.5 m and not exceeding 3 m complete all as specified and directed by Engineer-in-Charge.
53Returning, filling in including spreading, levelling, watering & well ramming in layers not execeeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
54Removing excavated soil / demolished material to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
55M&L for dry sand for cushioning for 15cm thick layer before laying cable and 8cm thick after laying and stetching the cable in trenches complete all as specified and directed by Engineer-in-Charge.Note : Only punned thikness shall be measured and paid.
56M & L for reinforced precast concrete cable cover, class HV, type 2 with peak, size 450mm x 230mm x 50mm complete all as specified and directed by Engr-in-Charge
57Supply and laying in trenches GI pipe light grade with fitting of size 100 mm bore for protection of cable incl taking down old one complete all as specified and as directed by the Engineer-in-Charge.
58M&L cutting road/path way (concrete) any type including excavation returning in spreading, leveling , well ramming in layers, soiling with stones, WBM 7.5 CM thick and laying premix carpet 25mm thick using ready mix patch mate material, including rolling and compection of path work complete all as directed.
59Taking out defective / unserviceable HT cable 11 KV of size 95/120 Sqmm 3 core from duct / wall / floor/ trenches required at site complete all as specified and directed by Engineer-in-Charge.
60Supply & laying HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 95 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed by the Engineer-in-Charge.
61All as per item No 59 but cable size 120sqmm core
62M&L in replacement of straight through heat shrinkable joint for HT 11 KV XLPE cable 95 Sqmm 3 Core complete including testing all as specified and directed by Engineer-in-Charge.
63All as per item No 61 but cable size 120sqmm core
64M&L in replacement of end termination heat shrinkable out door type kit complete with jointing material and accessories for HT 11 KV 95 Sqmm 3 core cable including testing complete all as specified and directed by Engineer-in-Charge.
65All as per item No 63 but cable size 120sqmm core
66All as per item No 63 but cable size 150sqmm core
67M&L in replacement of end termination heat shrinkable In door type kit complete with jointing material and accessories for HT 11 KV 95 Sqmm 3 core cable including testing Complete all as specified and directed by Engineer-in-Charge.
68Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ Replacement of broken/worn out components and insulators etc complete all asdirected.
69S&F in replaecment of of HT 11 KV out door type Isolator air break switch triple pole manually operated ,off load , including GI pipe, handle,connecting rod, male female copper connector, insulators and all connecting materials suitable for horizontal /vertical mounting fixed type complete rating upto 200 Amps complete all as specified and directed by Engineer-in-Charge.
70Routine and periodical work required for trimming / cutting of tree branches of any girth, touching /obstructing the over head lines of HT/LT poles of three phase distribution system at places not more than 40 mtr span distance so as to keep minimum 2.0 mtr clearance all around the lines and poles with due care after taking proper electric shoutdown from concern MES competent staff complete disposal thereof ( trimmed branches) to a distance not exceeding 100 metre , complete all as specified and directed by Engineer-in-Charge.Note: T&P will be provided by the contractor. No extra payment made for it.
71M&L for preparing scraping the old painted surfaces and applying two coat of aluminium paint on steel tubular swaged poles 11 mtrs long steel and swan neck /bracked, chanels / angles including making/pasting three nos cricular strips of 300 mm wide yellow & black colour with synthetic reflected enamel paint and marking /stencil writing of pole numbers with black paint complete and all as specified and directed by the Engineer-in-Charge.
72Taking down old unserviceable lightening arrestor 11 KV, complete all as specified and directed by Engr-in-Charge.
73S&F in lightning arrestor comprising of sealed hollow porcelain housing consisting of stack of zinc oxide dries encapsulated in heat shrinkage sleeve distribution class, Rated voltage-12KV (Rms), Discharge cap-5 KA-10KA, Line discharge class-1 complete with bracket and connection complete all as specified and directed by the Engineer-in-Charge.
74Dismantling and taking down old/unsv cross arms, bracing, supports etc complete all as specified and directed by the Engineer-in-Charge.
75M&L cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,cutting,welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complete all as specified and directed by the Engineer-in-Charge.
76Dismantling and taking down old/unsv ACSR conductor any size complete all as specified and directed by the Engineer-in-Charge.
77S&F ACSR conductor incl jointing with existing conductor and strengthning on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection complete all as specified and directed by the Engineer-in-Charge.Note :- Size of aluminium conductor as per site requirement will be directed by Engineer-in-Charge.
78Dismantling and taking down old/unsv insulator of any type any size from pole/stay complete all as specified and directed by the Engineer-in-Charge.
79S&F of Loop type insulator, porcelian vitreous white, brown or green of size 90mm x 140mm and clearence of hole 25.5mm complete all as specified and directed by the Engineer-in-Charge.
80S&F of Disc type insulator porcelain, vitrous white 145mm high and 255 mm dia ball and socket type white, brown or green single disc with tension clamp for conductor for working pressure voltage 11000 V complete all as specified and directed by the Engineer-in-Charge.
81S&F of pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150mm height and 150 mm dia for 11000 volts grade complete all as specified and directed by the Engineer-in-Charge.
82Dismantling stay assembly complete al as directed.
83M&L for Stay assembly using 16mm dia galvanised rod complete all as shown in electrical plate No. 1 of SSR Part-I including dismantling unsv one complete all as specified and directed by Engineer-in-Charge. (Clamps, loop insulator, earth work, PCC measured separately).
84S&F in replacement stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismentling taking down unserviceable one complete all as specified and directed by Engineer-in-Charge.
85Dismantaling anti clambing device barbed wire complete all as specified and directed by the Engineer-in-Charge.
86M&L for Anti climbing devices comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed by the Engineer-in-Charge.
87S&F in relacement of bus bar insulator for 11 KV, VCB bus bar all as per existing size and type complete all as specified and directed by the Engineer-in-Charge.
88S&F in relacement of Small charging gear for 11 KV, HT VCB all as per existing size and type.complete all as specified and directed by the Engineer-in-Charge.
89S&F in relacement of Big charging gear for 11 KV, HT VCB of all as per existing size and type complete all as specified and directed by the Engineer-in-Charge.
90S&F in relacement of Rack in out gear for 11 KV, HT VCB all as per existing size and type complete all as specified and directed by the Engineer-in-Charge.
91S&F in relacement of vaccum interpetor set (stud/non stud type) for 11 KV, VCB, as per existing size and type. The material to be synchronoised with the present system complete all as specified and directed by the Engineer-in-Charge.
92S&F in relacement of Jaw contact for 11 KV, HT VCB of all as per existing size and type complete all as specified and directed by the Engineer-in-Charge.
93S&F in relacement of Trip Neutral and close switch for 11 KV, HT VCB of all as per existing size and type complete all as specified and directed by the Engineer-in-Charge.
94M&L for dismantling reinceforce cement concrete pole /Iron poles/struts of any size and type including breaking of concrete cutting of mild bars of any size from below the ground level up to 60 cm depth and all items removing from site all as directed by Engr -In- Charge (Note :Excavation earth work included in this quoted rate)
95Supplying, transporting, erecting and fixing up steel tubular swaged pole overall height 11 mtrs type 410 SP 55 complete with cast iron base plate pole cap finial taper plag bolt nut washer etc complete all as specified and directed by the Engineer-in-Charge.Note: Excavation and PCC shall be measured seperately.
96M&L for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of reconstruction old damaged copings etc, including necessary form work complete all as specified and directed by the Engineer-in-Charge.
97M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate for coping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and directed by the Engineer-in-Charge.
98M&L for PCC 1:4:8 type D-2 using 40 mm graded aggregate for foundations of poles etc, complete all as specified and directed by the Engineer-in-Charge.
99T&P and labour for cutting /uprooting / bushes / shrubs / grass / saplings / plant / trees etc not more than 3.0mtr high and setting aside not less than 50 mtr away from power house premises of 100sqmtr complete all as specified and directed by the Engineer-in-Charge.
100T&P and labour for cutting /uprooting /bushes /shrubs /grass /saplings /plant /trees etc not more than 3.0mtr high and setting aside not less than 50mtr away from single pole of 3 sqmtr complete all as specified and directed by the Engineer-in-Charge.
101T&P and labour for cutting /uprooting /bushes /shrubs /grass /saplings /plant /trees etc not more than 3.0mtr high and setting aside not less than 50mtr away from two pole structure of 12 sqmtr complete all as specified and directed by the Engineer-in-Charge.
102T&P and labour for cutting /uprooting /bushes /shrubs /grass /saplings /plant /trees etc not more than 3.0mtr high and setting aside not less than 50mtr away from 4 pole structure of 12 sqmtr complete all as specified and directed by the Engineer-in-Charge.
103Disconnecting after proper shutdown all electrical connections, loading, unloading into transport to civil workshop for dismantling of servo voltage stabilizer of the following capacities for complete servicing, relacement of unserviceable spares & refitting at same location in same position.Note : Replacement of unserviceable spares shall be measured as supply only & paid separately under relevant item of CA.
104(a) 50 KVA
105(b) 100 KVA
106(c) 200KVA
107M&L in replacement of re-winding of primery /secondry winding of main transformer (servo voltage stabilizer) one phase with copper wire of same type and size/gauge of existing. Servo type voltage stabilizers of following capacities complete all as specified and directed by the Engineer-in-Charge :-
108(a) 50 KVA
109(b) 100 KVA
110(c) 200 KVA
111M&L in replacement of re-winding dimmerstatic of servo voltage stabilizer rewinding with copper wire of same type and size/gauge of existing. Servo type voltage stabilizers of following capacities complete all as specified and directed by the Engineer-in-Charge :-
112(a) 50 KVA
113(b) 100 KVA
114(c) 200 KVA
115M&L in replacement of following items of servo type voltage stabilizers AC driven 440 Volts, 50 Hz complete all as specified and directed by the Engineer-in-Charge :-
116(a) Push button switch
117(b) Auto Manual switch
118(c) DPDT switch
119(d) Micro switch
120(e) Panel lamp
121(f) Potentio meter
122(g) Voltmeter
123(h) Ampere meter
124(j) Electronic Circuit Card (PCB)
125(k) PCB holder
126(l) Trigger Transformer
127(m) Rotary switch 5 Amp for R, Y, B phases
128(n) Servo Motor 3 Kg (f)-m Torque
129(o) Servo Motor 6 Kg (f)-m Torque
130(p) Servo Motor 10 Kg (f)-m Torque
131(q) R C Network 3 Kg (f)-m Torque motor
132(r) R C Network 6 Kg (f)-m Torque motor
133(s) R C Network 10 Kg (f)-m Torque motor
134(t) Carbon brush with spring & holder
135(u) Motor Capacitor 0.8 mfd to 4.0 mfd
136(v) Input & output bakelite connector block
137(w) Variac operating chain
138(x) Cam & bush for variac operting chain
139(y) Servo motor resister 1000 Ohms, 10 watt
140(z) Carbon brush set
141(ab) Carbon brush holder
142M&L for including T&P for shifting of transfomer of any capacity after disconnecting HT/LT connection ,Earth connections and reconnecting the same after placing it near by on stable ground in order to facilitate continious power supply to end users. Demolishing the existing plinth any type any size and setting aside the debris from the existing location not less than 50 Mtrs away. Constructing double brick wall(24 cm thick) for construction of PCC platform/plinth for transformer size 3 mtr x 3 mtr x 1mtr with nitches of size 0.3 mtr X 1 mtr (2 Nos) for HT/LT cables as per design provider by Engr In charge including PCC 1:3:6 filling in between the constructed walls, curing for seven days to form solid flat platform for housing the transfomer. The externel walls of plinth / platform shall be provided with plaster 6 mm thick in CM mortar 1:6. Two channels of size ISMC 100, 3 Mtr Long shall be placed on external brick wall to house & support wheels of transformer. After sufficient curing of walls of constructed plinth for at least 7 days transformer shall be shifted back on newly constructed platform complete all as specified and directed by Engineer-in-Charge.
143M&L in replacement of Danger notice plate of 1.6mm thick mild steel sheet, viterous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size for HT 11000 Volts, 25 x 20cm size complete all as specified and directed by Engineer-in-Charge.
144M&L for taking out cable loop after excavtion near panel/pole after taking shut down, cutting and setting aside burnt cable ends/lugs and peeling off insulation of cable upto required length for making connection at pole or insertion of new cable lugs in cable, creaming properly and making connection in panel, feeder piller box junction box and tightning with and including new bolts nuts & washers of required complete all as specified and directed by Engineer-in-Charge.
145Supplying and laying in replacement of synthetic rubber insulated mats 2.5mm thick for voltage upto 11KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2mtr x 1mtr complete all as specified and directed by Engineer-in-Charge.
146Supply and fixing in replacement of Electrical rubber hand gloves for 11KV complete all as specified and directed by Engineer-in-Charge.
147M&L in replacement of Para tape
148M&L in replacement of Empire tape (20 m-25 m length)
149M&L in replacement of Cotton tape
150M&L in replacement of Insulation tape 25mm wide 25 mtr length Complete all as specified and as directed
151S&F in replacement of Glow Sign board of following size and showing given name on Acrylic sheet/Fibre glass re-inforced translucent corrugated sheet 2mm thick with MES Logo (symbol) necessary Vinyl Blue Sticker along with 04 No's LED Tube light fitting 20 watts incl nessary connection with 1.5 Sqmm flexible copper wire and fixed on structure with aluminum equal angle as per required size , sufficient Nos brass machine screws with and incl errection complete all as directed.Note:-GI pipe 50 mm bore for errection of glow sign board will be included in this quoted rate. GLOW SIGN BOARD SIZE 7.00m x 0.60m x 0.20m-01 No incl angle iron size 50 x 50 x 6mm length 01 ft –02 Nos grouted in Main entrance Piller with cement plastering or GI Pipe 50mm bore for fixing the glow sign board. MES POWER HOUSE AGE (E/M) DHAR ROAD UNDER GE(ARMY) DHAR ROADNote for item No : 150 (i) Rest of the sides of the structure except front side will be covered with galvanized plain sheet 0.80mm thickness with zinc coating both sides fitted with nut, bolt washer 25mm length 6mm dia (ii) Bottom support:- M&L for angle iron size 50mm x 50mm x 6mm length 1 ft –02 Nos grouted in suitable PCC 1:4:8 type D2 40mm graded platform with cement plastering or fixing on the GI Pipe 50mm bore for fixing the glow sign board all as directed by Engr-in-Charge.(iii) All galvanized plain sheet and equal angle iron painted with 2 coat of synthetic enamel paint over a one coat of red oxide paint as per approved colour included in this quoted rate all as directed by Engr-in-Charge
152Supply and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminiumconductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 06 sqmm 2 core complete all as directed.
153S & F in replacement of Rigid non-metallic PVC conduit exclusive 2 mm thick 20 mm dia of boxes junction/terminal) but inclusive of all tees, bends, elbows, educers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. etc complete all as specified and directed. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56240882
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Rewinding Of Certain Transformers Vcbs/ Servo Stabilizer Under Ge (Army) Dhar Road Udh Ur
Basic Detail
Tender No CWE/U(DR)-49/2026-27
Bidding Type Tender
Location
City Reasi
State Jammu and Kashmir
Key Dates
Publish Date 30 Jun 2026
Submission Date 21 Jul 2026
Open Date 23 Jul 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Not Available
Document List
0ac7748b-a0b5-4567-bff9-e1d10ac8090c.html
BOQ_868267.xls
Tenderdocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

0ac7748b-a0b5-4567-bff9-e1d10ac8090c.html

xls

BOQ_868267.xls

pdf

Tenderdocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender