Tender for Provn Of Geysers Alongwith Upgradation Of Transformer At Jcos / Or Md Accn At Sarvatra Nagar Under Ge Dehu Road
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, installation, testing and commissioning of 200 KVA capacity (continuous loading) BEE 4 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out doorapplications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sq.mm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and as per SSR specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 0C for oil and 40 dg. C up to 200 KVA . Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. |
| 2 | Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodizedaluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall beindelibly marked Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oiltemperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s; t) Additional Neutral separately brought out on bushing for earthing. v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. |
| 3 | Supply & Erect Steel sewaged tubular poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified of type 410 SP-55 (11.0 Mtrs Long) including Painting with two coats of aluminium paint over a coat of red oxide primer complete after preparation of steel surfaces and writing letters / Numbers not more than 10 cm high by Black paint all as directed.. . |
| 4 | Supply and fix cross arms, bracing, support, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shapes or size including one primer coat, one under coat and one finishing coat all as directed. |
| 5 | Supply and fix lightning arrestor HT 11 KV 10 KA station class |
| 6 | Supply and fixing Polymeric composite Disc Insulator,as per IEC 61109,Material of FRP Rod-Boron free ECR,Material of sheds -Silicon Rubber,Type of metal end fittings-Tongue & Clevis,Material of sealing compound-RTV SiliconCreepage distance ( min ) -320 mm ,Length of FRP Rod ( min )-200 mm,Dry arc distance -170 mm suitable for 11 KV all as specified . |
| 7 | Supply and fix earth strip of size 32 x 6 mm galvanised iron strip fixed to wall/over head reservoir on batten or recess or chases or buried inground or drawn in conduit /pipe fixed on poles insulated as per Engr-in-Charge. |
| 8 | M & L for danger notice board,Supply and Fixing, Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, forHT, 25x20cm size |
| 9 | M & L for Aluminium conductor, steel reinforced(ferret) |
| 10 | M & L taking down unserviceable GOD,and supply and fixing Triple pole, mechanically operated mounted on insulator and steel frame, with operating mechanisum worked from ground level GOD 11 KV heavy duty, for current rating 400 with drop out fuse assembly complete all as directed.Make:Pactil,Jaipuria,HEI |
| 11 | Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 95 sq. mm.Make :- Havells/ Polycab/ Gloster |
| 12 | M & L cable joint,supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm |
| 13 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core |
| 14 | M&L for Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I incl all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc including taking down old U/S Earthing, all as specified and as directed. |
| 15 | Supply and laying of GI pipe 80 mm dia medium grade for protection of cable |
| 16 | Excavation in trenches in Soft / loose soil not exc 1.5m wide and not exc 1.5 m in depth for laying cable,erection of poles,stay and pipe line,complete allas directed. |
| 17 | Excavation in trenches for errection of poles etc.,n. exc 1.5m wide, exc 1.5m and n. exc 3.0m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 18 | Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed. |
| 19 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge. |
| 20 | M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 21 | M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed. |
| 22 | Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back sloped canopy (Hood) on top , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor of suitable size for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Anlge iron frame of sutable size of 50mm x 50mm x 6mm thick MS angle, 30 CM above ground level &30 CM below gland consisting of following;- (a) Busbar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic,non combustible,track resistant high strength FRP insulators for phases and neutral set of 4 for RYB &N -01 set. (b) ACB 630 Amp, 4 Pole, 36 KA for main incomer -01Nos . (c)MCCB 320 Amp, 4 Pole, 25KA for Outgoing - 03 Nos (d) Digital Voltmeter -01No. (e)Digital Ammeter with set of CTs -01No. (f)Indicating lamp RYB -01Set. |
| 23 | Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back sloped canopy (Hood) on top , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor of suitable size for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Anlge iron frame of sutable size of 50mm x 50mm x 6mm thick MS angle, 30 CM above ground level &30 CM below gland consisting of following;- (a) Busbar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic,non combustible,track resistant high strength FRP insulators for phases and neutral set of 4 for RYB &N -01 set. (b) MCCB 250 Amp, 4 Pole, 36 KA for main incomer -01Nos . (c)MCCB 63 Amp, 4 Pole, 10KA for Outgoing - 04 Nos (d) Digital Voltmeter -01No. (e)Digital Ammeter with set of CTs -01No. (f)Indicating lamp RYB -01Set. |
| 24 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified. |
| 25 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified |
| 26 | S & F Hand rails, half round or othersteel section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to stepsincluding embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessarydrilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165.etc. complete all as specified and as directed by Engr - in - charge. |
| 27 | S & F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 28 | Mild steel round bars 10mm dia of Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165) and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 29 | M&L for preparing of new steel and iron surfaces and applying two coat of synthetic enamel paint over and including a coat of red oxide primer of any description ,over 10cm in width or girth,etc complete all as specified and directed. |
| 30 | M & L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited,spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified. |
| 31 | M&L for 100mm thick cement concrete of type B-1 1:2:4 (using 20 mm graded aggregate) as in foundation of transformer all as required and directed. |
| 32 | M&L Brick Work with Sub-Class ‘B’ Bricks Straight or Curved on Plan exc. 6.0 METRE mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed. |
| 33 | M&L for 15 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair complete all as specified and directed. |
| 34 | M & L for laying of gravel of 20 mm size near transformer and four pole structure all as specified and directed |
| 35 | M & L Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete as specified. |
| 36 | Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long,diameter of neck 11 to 15 mm complete all as specified. |
| 37 | Excavating in post holes (orsimilar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,in soft/loose soil etc complete as directed |
| 38 | M&L for casing capping point wiring with 2.5 Sqmm two single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 V grade confirming to IS 694 drwan through PVC casing capping of size heavy grade ISI marked including necessary casing capping with accessories, heavy duty PVC terminal including 2.5 Sqmm PVC insulated FRLS copper conductor as in continious earth wire for 16 Amp , Switch/Socket combination on Independent board complete all as specified and directed. |
| 39 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 40 | Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc complete all as specified and directed. |
| 41 | S & F tubes medium grade galvanised with all fitting for fixing on wall complete of 15mm dia with complete fitting and fixture all as specified and directed. |
| 42 | S&F Bib taps,cast copper alloy with crutch or butterfly handle ,screwed down, screwed for iron pipe or for brass ferrule and fixed of cap 15mm dia complete all as specified and directed. |
| 43 | S&F PVC connection 15mm size for cold water with PTMT nuts of length 450mm complete all as specified and directed |
| 44 | S&F CP connection 15mm size for hot water with PTMT nuts of length 450mm complete all as specified and directed |
| 45 | S & F stop valve 15mm bore CP with crutch or butterfly handle screwed both for iron pipe or unionscomplete all as specified. |
| 46 | M & L for cutting existing GI tubing of size 15 mm for alterations or additions (Each cut measured) complete all as specified. |
| 47 | M & L single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB complete all as specified. |
| 48 | M & L Plug top of 20 amp suitable socket complete all as specified. |
| 49 | Material and labour for Sub-main wiring complete with 2.5 sqmm two single core PVC insulated but unsheathed multistranded copper conductor cable 1100 V grade drawn through concealed PVC casing caping with wall thickness not less than 1.8 mm incl sunken type pressed steel terminal boxes including2.5 sqmm single core PVC insulated but unsheathed copper conductor grade 1100 V grade cable as earth continuity wire complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysJul 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender