Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #56240804

Tender For Repair/ Replacement Of Ac, Refrigerator, Water Cooler And Geysers And Petty Repairs/ Rewiring Of Internal Electric Supply Of Building Including Submain, Db, Ceiling, Exhaust, Wall Mounting, Pedestal Fan And Its Connected Works In Technical

Issued by Statutory Bodies & Commissions/Committees · Dehradun, Uttarakhand
Tender Value
38 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
11 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Ac, Refrigerator, Water Cooler And Geysers And Petty Repairs/ Rewiring Of Internal Electric Supply Of Building Including Submain, Db, Ceiling, Exhaust, Wall Mounting, Pedestal Fan And Its Connected Works In Technical And Residential Area Of Irde Under Ge (I) R&D Dehradun

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF AC, REFRIGERATOR, WATER COOLER AND GEYSERS AND PETTY REPAIRS/ REWIRING OF INTERNAL ELECTRIC SUPPLY OF BUILDING INCLUDING SUBMAIN, DB, CEILING, EXHAUST, WALL MOUNTING, PEDESTAL FAN AND ITS CONNECTED WORKS IN TECHNICAL AND RESIDENTIAL AREA OF IRDE UNDER GE (I) R&D DEHRADUN
Sl. No. Item Description
1Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed by Engr-in-Charge. Note: (Applicable for Sch ‘A’ Item No.1). (i) Split type AC's shall be taken from department on \\"as and where installed\\" basis.(ii) Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1).(iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
2M&L for Repair to existing rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
3Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
4Supply only new Rotory invertor type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
5Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
6Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge.
7Labour only for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity all as directed by the Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’).
8M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity/water cooler complete, all as specified and directed by Engr-in-charge.. (Make : Universal/Sarda )
9M&L for replacement of unserviceable capillary tube and stainer for window/Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
10M&L for replacement of unserviceable PVC air filter for Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
11M&L for replacement of unserviceable capacitor for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
12M&L for replacement of unserviceable swinging motor with louvers as per existing make for Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
13M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .
14M&L for replacement of unserviceable Inverter PCB for Indoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed.
15M&L for replacement of unserviceable Inverter PCB for outdoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed.
16M&L for replacement of unserviceable LCD / LED display unit for Window/split type AC 1.5 / 2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
17M&L for replacement of unserviceable 15/20 mm bore PVC flexible conduit complete, all as specified and directed by Engr-in-charge.
18Supply and fixing in replacing refrigerant copper tubing 5/8\\" / 1/2\\" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
19Supply and fixing in replacing refrigerant copper tubing 3/8\\" / 1/4\\" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
20Supply and fixing in replacment foam type insulation sleeve for copper tubing 5/8\\" / 1/2\\"/ 3/8\\" / 1/4\\" dia (as per existing one) binding and securing the insulation firmly with copper tubing as per site requirement complete, all as specified and directed by Engr-in-charge.
21M&L for replacement of unserviceable reverse cycle valve in window/Split type AC of 1.5 / 2 TR cap. and welding, brazing with copper tubing and testing complete all as specified and directed. Make : Renutrol/Pacific
22M&L for replacement of unserviceable PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete all as specified and directed by Engr-in-charge.
23M&L for replacement of unserviceable PVC insulated PVC sheathed 2.5 Sqmm, 4 core copper cable 1100 Volts confirming to IS complete all as specified and directed by Engr-in-charge.
24M&L for replacement of unserviceable internal wiring of AC of any capacity and rewiring the same with 2.5 Sqmm size multi stranded copper cable incl testing checking etc complete all as specified and directed by Engr-in-charge.
25Supply only refrigerant gas R-22/R-32
26Supply only refrigerant gas 134A.
27Supply only refrigerant gas R-407/R-410 (HYDRO CARBON)
28M&L for replacement of angular valve of size 5/8\\"/ 1/2\\" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge.
29M&L for replacement of angular valve of size 3/8\\"/ ¼\\" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge.
30Supply only Remote control for split/ Window type AC of LG/Havells/existing make of 1.5 TR/2 TR with battery complete,all as specified & directed by Engineer-in-Charge.
31Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed by Engr-in-charge.
32Installation/ shifting only split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton after carried out the repair under item No.1 at new location as directed including providing necessary chiseling/ cutting for fix the indoor/outdoor unit by means of suitable size of nut, bolt, angle iron structure, masonry work and making good the disturbed surface with PCC, plastering,white wash works,testing & checking complete,all as directed & specified by Engineer-in-Charge. (Note :- The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, blower motor and nut bolt angle iron structure) under relevant items shall be included in this item) complete all as specified and directed by Engr-in-charge.
33Supply & Fixing in replacement of unserviceable Outdoor unit body complete with out compressor unit suitable for existing Split type AC of 1.5 TR capacity, all as specified and directed by Engr-in-Charge.
34Supply & Fixing in replacement of unserviceable indoor unit body complete suitable for existing Split type AC of 1.5 TR capacity, all as specified and directed by Engr-in-Charge.
35Supply & fixing in replacement of heavy-duty outdoor unit stand/wall mounting bracket made of GI or MS Suitable for 1.5 TR to 2.0 TR split AC units, complete with anti-vibration pads, anchor fasteners, nuts, bolts, washers and all necessary fixing accessories placed on the wall, roof or ground alongwith weather-resistant, epoxy-polyester painted finish to prevent rust and corrosion in humid/coastal climates. Angle iron of size 3 mm thickness complete, all as specified and directed by Engr-in-Charge.
36Supply & fixing of heavy-duty, multi-layer waterproof and heat-resistant insulation covers designed for split AC outdoor units. Must feature a top UV-reflective aluminium foil layer laminated over a minimum 5 mm thermal insulation foam core. Universal size fitting standard 1.0 Ton to 2.0 Ton outdoor units (Approx. dimensions: 95cm x 46cm). Includes integrated adjustable nylon fixing straps with quick-release plastic buckles to resist high wind speeds. Fixing of the protection sheet on top of the existing outdoor condenser units, ensuring proper tensioning of straps without blocking the side or front air exhaust vents complete all as specified and directed by Engr-in-Charge.
37Supply & Fixing in replacement of unserviceable mild steel work as split type AC outdoor/water cooler wheel stand /supporting /protection cage etc. of suitable size of flat iron/Angle iron etc.,cut to shape, including bending and welding as necessary, etc.conforming to Fe.290.Gde-E-165, with and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete, all as specified and directed by Engr-in-charge.
38Supply & Fixing in replacement of unserviceable plug top 3 pin, 15/16 Amp capacity complete all as specified and directed.
39Disconnecting and removing the water and electric connections carefully from the existing Geyser of capacity 25/50 ltrs, any make and taking out the same in any position from the existing location. cleaning and de-scaling the inner tank using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge. Opening the Geyser for inspection, repairs and reassembling the same as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as ordered including re-fixing same position of the Geyser and making electric connection, water inlet and outlet connection, testing and checking of all the functioning of water inlet outlet valves connected with geysers.all as specified and directed by Engr-in-Charge. Note :- Spare parts if any requires replacement shall be measured and paid for separately.
40Supply only Rubber PVC gasket to ensure water tightness for 25/50 liters capacity complete, all as specified and as directed by Engr-in-charge.
41Supply only MS base plate cup any type with screws of suitable size as per requirement complete, all as specified and as directed by Engr-in-charge.
42Supply only Heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge
43Supply only Steel inner tank of 25/50 litre capacity geyser tank by made out of steel sheets appropriate thickness complete, all as specified and as directed by Engr-in-charge.
44Supply only Insulating material (glass wool for Geyser) complete, all as specified and as directed by Engr-in-charge.
45Supply only Thermostat with setting range 30°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
46Supply only Non return valve 15 mm dia cast copper alloy ISI mark complete, all as specified and as directed by Engr-in-charge.
47Supply only Safety valve/Fusible plug 15mm complete, all as specified and as directed by Engr-in-charge.
48Supply only Chromium plate copper connecting tube 450 mm long with two brass adopters suitable for 15 dia pipe and connecting up complete with washers complete, all as specified and as directed by Engr-in-charge.
49Supply only PVC connecting tube 450 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality as approved by Engineer-in-charge.
50M&L in replacement of unserviceable bottom plate of geysers 25/50 liters capacity, same sizes and shape complete all as specified & directed.
51M&L in replacement of unserviceable air release valve 15 mm bore for geyser as per existing type complete all as specified and directed.
52M&L in replacement of unserviceable Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed
53M&L for Painting of geysers size 25/50 liter any make with two coats of broken white enameled paint with spray gun of approved quality after removing all dust/rust and scrapping up old painted surface including preparation, filling of cavaties with metal putty, complete including writing MES No in 2 mm width letter on geyser body with black enameled paint complete all as specified and directed.
54M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.50 Sqmm as earth continuity conductor complete all as specified and directed.
55Supply only assembly type round/ triangle heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge
56Supply only PVC hot and cold connecting tube 600 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality as approved by Engineer-in-charge.
57Supply and fixing sheet metal box with MCB 20A and with 3 pin socket and top etc complete all as specified superior quality as approved by Engineer-in-charge.
58Supply only Thermostat bellow type with setting range 00°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
59Supply only Thermostat cut out bellow type with setting range 00°C to 100°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
60Supply and fixing fastener of size 3\\" /4\\" fixing of geyser or as per site requirement, complete all as specified and directed.
61Supply and fixing 'U' assembly 6/9 hole for 25 ltr geyser complete all as specified and directed.
62Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed by Engr-in-charge.
63Disconnecting , taking down & removing carefully the existing ceiling fan/Exhaust fan/wall mounting fan/ pedestal fan etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations etc) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed. Note for item 63.00 : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding.
64(iii) The rates for above items are deemed to include for transportation to & from of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv)Cost of minor repair i.e. loose connection tightening, oiling greasing, tightening nut- bolts, insulating wire etc deemed to be inclusive in the item rate above. (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’
65Supply only the following new parts suitable for the ceiling/ exhaust fans, wall mounting fans & pedestal fans etc. of any description, any sweep :- Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item No. 63.00
66Supplying only ball bearing No 6200/ 6201/ 6202/ 6203 (Make SKF/NRB/NBC)
67Supplying only capacitor of capacity 2.5 mfd (PVC body) (Make:- EPCOS/JYOTI/ USHA)
68Supplying only capacitor of capacity 4 mfd (PVC body) (Make:- EPCOS/JYOTI/USHA)
69Supply only complete hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with lock pins suitable for any type of fans & down rods of length 300mm.
70Supplying only PVC fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions & of 250/ 300 mm sweep. (Note: Set of three blades shall be measured as one unit and make of assembly shall be as approved by GE.)
71Supply only MS tube medium grade 15mm dia duly finished with white colour two coats over a coat of red oxide cutting in desired length from 300mm to 1500mm, cutting slot and drilling hole for down rod of fan complete all as specifieda and directed.
72Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire (Make : Atlas/Finolex/Devi Dayal)as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-
73Rewinding of motor of ceiling fans 1200 mm sweep.
74Rewinding of motor of exhaust fan of 250/300/450 mm sweep.
75Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers for exhaust fan of 250/300/450 mm sweep all as specified & directed by Engineer-in-Charge. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer)
76Disconnecting and taking out old existing unserviceable ceiling fan modular regulator of any description and in any position/ location and supply and fixing ceiling fan modular regulator electronic, step type, 1M/2M size modular type , suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply complete all as specified and directed.
77M&L for painting of existing fans of any description of ceiling fan of 1200/1400mm sweep with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans complete, all as specified and directed by the Engineer-in-Charge.
78M&L for painting of existing fans of any description of exhaust fan of 250/300/450mm sweep with applying one coat of synthetic enamel paint grey by spray machine including preparation of existing decorated surfaces of fans complete, all as specified and directed by the Engineer-in-Charge.
79Supply and fixing ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor, all as specified and directed by Engr-in-Charge.
80Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed by Engr-in-Charge.
81Supply and fix exhaust fan made of metal body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed by Engr-in-Charge.
82Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed by Engr-in-Charge.
83Supply and fixing wall mounted fan of, 230 V, 50 Hz, 1350 RPM, 400 mm sweep, Min air delivery 72 CFM complete all as specified and directed by Engr-in-Charge.
84Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
85M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch.
86Description all as per Srl item No. 76.00 here in before but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent omplete all as specified and directed.
87Description all as per Srl item No. 76.00 here in before but for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed.
88Description all as per Srl item No. 76.00 here in before but for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed.
89Description all as per Srl item No. 76.00 here in before but for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Please Enable Macros to View BoQ information
90Description all as per Srl item No. 76.00 here in before but for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56240804
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Ac, Refrigerator, Water Cooler And Geysers And Petty Repairs/ Rewiring Of Internal Electric Supply Of Building Including Submain, Db, Ceiling, Exhaust, Wall Mounting, Pedestal Fan And Its Connected Works In Technical And Residential Area Of Irde Under Ge (I) R&D Dehradun
Basic Detail
Tender No GE(I)RND/9595/E8/26-27
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 30 Jun 2026
Submission Date 20 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value 38 Lakhs
Tender Fee 500
EMD 76000
Exemption Available
Document List
BOQ_868246.xls
f78eece8-28e3-40df-842e-7c6c07b8f618.html
GCSM.pdf
SpecialconditionandPS.pdf
Tendernotice_1.pdf
Tenderpage.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_868246.xls

html

f78eece8-28e3-40df-842e-7c6c07b8f618.html

pdf

GCSM.pdf

pdf

SpecialconditionandPS.pdf

pdf

Tendernotice_1.pdf

pdf

Tenderpage.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender