Tender For Special Repair To Bldg No T-1233, T-1235 & Tc-88 Of 405 Lt Ad Regt (Sp) Under Ge Hisar At Mil Stn Hisar
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling/granite including cement mortar bedding (but not backing) removing, serviceable tiles to stone and rubbish off the premises all as specified and directed. |
| 2 | Dismantling asbestos cement / GI (corrugated, semi corrugated etc) sheets in roof covering of any description complete |
| 3 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall / as window chajja, fixed with shelf tapping screws as specified complete |
| 4 | M&L for prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified. |
| 5 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed. |
| 6 | S&F Rolled Mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 stance ieces, cleats etc complete all as specified & directed. |
| 7 | S & F rolled mild steel sections angle/ tubular/ square/ rectangular confirming to Fe 410 - W as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as specified & directed. |
| 8 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including hangers an grid complete all as specified & directed. |
| 9 | S&F, GI powder coated snap grid of sizes 605 mm x 605 mm frame work for false ceiling with main tee 32x24x1mm thick, cross tee 26x24x1mm thick and wall angle 24x24x1mm thick, flange covered with PVC thin sheet including gypsum board 7-9 mm thick, duly finished surface (thin PVC layer on gypsum board as per manufacturer instructions) size 600mm x 600mm and the same to be placed in snap grid as in false ceiling and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 10 | M&L for glazed coloured ceramic tiles in vertical surfaces 450x300 6 to 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 on other then fair faces of brick work etc complete all as specified and directed. |
| 11 | M&L for 18 to 20 mm thick machine cut Kota stone (550 x 550 mm)flooring over cement screed base laid and jointed with grey cement slurrry mixed with pigments to match the shade of the slab including rubbing and polishing complete all as specified over and including 15mm thick screed bed in CM 1:6 complete all as specified & directed. |
| 12 | All as per item No 11 above but kota stone slab (100/150mm x 550mm) and 18-20mm thick in riser of steps, skirting , dados and pillar laid over and including 10mm thick rendering to receive the stone in cement mortar 1:4 and jointed complete specified and as directed. |
| 13 | M&L for mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified & directed. |
| 14 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectingular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 etc complete all as specified & directed. |
| 15 | M&L for factory made rubber moulded chequered cement concrete tiles 25cm x 25cm x 25mm thick,set, jointed and pointed in neatcement slurry in floors with grey cement and pigments complete all as specified and directed. |
| 16 | M&L for Screed bed or bedding layer of mortar 15 mm thick in cm 1:6 for laying floor finishes complete all as specified and directed. |
| 17 | M & L granite ( of any type ) work ( table rubbed and polished ) 18 to 20 mm thick in steps, jambs, pillars, window cill , cooking platform and flooring in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite with and including screed bed or bedding layer 15 mm thick, in CM 1:4 complete all specified and directed. |
| 18 | Dismantling of Stone/concrete slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar etc complete all as specified and directed |
| 19 | M&L for 75mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified & directed. |
| 20 | M&L for factory made machine pressed precast concrete rubber moulded coloured interlocking paver block any shape and size confirming to IS 15658 - 2006 of 60 mm thickness, M-35 Grade laid over and incl 25mm thick sand cushioning layer in floors/path/parking complete all as specified and as directed. |
| 21 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 22 | Demolition of Brick work, stone/boulder or block masonry, built in cement mortar excluding ashlars facing dressed stone work and pre-cast concrete etc complete all as specified. |
| 23 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. |
| 24 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each and making good the hold fast notch / disturbed portion with PCC 1:3:6 type C1 (20mm graded aggregates)complete all as specified and directed by Engr-in-Charge. |
| 25 | Taking down shutters of any description exc 1.00 Sqm and n.exc 2.00 Sqm each complete all as specified and directed. |
| 26 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 27 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws,including all SS fittings all as per direction of Engineer-In-Charge. |
| 28 | S&F factory made mild steel complete windows set with frame (Box Type ) with side hung double shutters (wire mesh and glass) including glazing iron grill bars to receive glass, dovetailed or welded with and including all necessary welding, reveting, tower bolt, hanlde, holdfast, hinges and steel peg complete incl making good painted the disturbed portion all as specified and directed by Engr-in-Charge. (CEJZ/TD-2013/01) |
| 29 | S&F in repairs galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified & directed. |
| 30 | S&F 3 mm sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each pane complete.all as specified and directed. |
| 31 | S&F Powder coated aluminium deco grill fixed to powder coated windows and doors complete all as specified and directed. |
| 32 | S&F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepare to receive glass, gauge etc (withsash bars) edges but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers as specified in SSR Part-I Section 8 Clause 8.24(a), fitted to chowkats complete all as directed. |
| 33 | S & F in repair curtain rails, Stainless steel decorative type with fixing brackets, stops, rollers etc complete all as directed by Engr-in-charge. |
| 34 | S&F powder coating anodised aluminium extruded sections as in frame for doors, windows, ventillators, partions including joining cleat for fixing etc complete all as directed. |
| 35 | S&F anodised aluminium powder coated window and ventilator, 3mm glass shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified & directed. |
| 36 | S&F prelaminated particle board, 12mm thick, interior grade, prelaminated both side with decorative choice lamination fixed with screws to aluminium frame work complete all as specified & directed. |
| 37 | Taking down cement plaster of any description built in cement mortor complete all as specified and directed. |
| 38 | M&L 10mm thick cement plasters in CM 1:6 on concrete or brick wall surfaces finished even & smooth with out using extra cement. |
| 39 | M&L for 15 mm rendering in two layers with 10 mm with CM 1:6 & 5 mm thick with CM (1:4) with using water proffing compound on fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified |
| 40 | Supply only Water Proofing Compound ISI Marked |
| 41 | M&L for applying 3mm thick wall care putty on wall surface complete all as specified. |
| 42 | M&L for preparation of newly plastered of wall surfaces and applying two coats of cement based paint over a coat of cement primer as approved complete all as specified. |
| 43 | M&L for preparation of newly plastered of wall surfaces and applying two coat of oil emulsion distemper over a coat of cement primer complete all as specified. |
| 44 | M&L for preparation of old decorated wall surfaces of any description and applying one coat of oil emulsion distemper of any tint etc complete complete all as specified and directed by Engr-in-charge. |
| 45 | M&L preparation of new or previously untreated surfaces of steel of any description over 10cm width or girth not otherwise described over applying two coats of synthetic enamel paint over a coat of a red oxide zinc primer. |
| 46 | M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge. |
| 47 | M&L cement concrete in foundation filling and mass concrete 1:2:4 type B-2(using 40mm graded Agg) all as specified. |
| 48 | Dismantling old unserviceable PVC water tank capacity 500 ltr and not exc 1000 ltrs & removal from site etc complete all as specified and directed. |
| 49 | S&F 1000ltrs capacity rotational moulded polyethylene water storage triple layer white tanks (cylindrical verticle with closed top) hoisted and fixed in position including necessary pipes and fittings complete all as specified and directed. |
| 50 | Taking up or down 15mm bore steel tubing and connection incl cleaning for refixing or removal to store |
| 51 | Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing or removal to store |
| 52 | S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm all as specifiied and directed by Engineer-in-Charge |
| 53 | S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 20mm all as specifiied and directed by Engineer-in-Charge |
| 54 | S&F sink with drainage board made of stainless steel 1 mm thick with plug and washers and waste pipe including bedding in cement mortar to dwarf wall or including fixing cantilever brackt and connacting union to pipe over all size 495 x 420 mm and bowl size 410x330x160 mm compleete all as specified |
| 55 | Supply and fixing GI wire cloth 0.56mm nominal dia of wire and avg width of aperture 1.18mm complete all as specified and directed. |
| 56 | S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified. |
| 57 | S&F stop valve cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed in repairs complete 15mm dia complete all as specified and directed. |
| 58 | S&F in repairs 15 mm dia chromium plated fancy type angle cock with wall flange concealed type of equivalent make specified here in after complete all as specified and directed. |
| 59 | S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or fixed to wall of size 110mm bore complete all as specified and as directed. |
| 60 | S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or fixed to wall of size 75mm bore complete all as specified and as directed. |
| 61 | S&F grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) |
| 62 | S&F Bib taps, 15 mm bore castcopper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 63 | Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed. |
| 64 | M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including modular covered plated and frame all as specified & directed. |
| 65 | All as per item No. 64.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board. |
| 66 | All as per item No. 64.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board. |
| 67 | All as per srl item No. 64.00 (here-in-before) but for 15 Amp socket out let by using 2.50 sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed. |
| 68 | S&F modular type switch , single pole, one way, 5/6 Amp, 230 Volts complete all as specified and directed. |
| 69 | S&F modular type switch , single pole, one way, 15 Amp, 230 Volts complete all as specified and directed. |
| 70 | S&F modular type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed. |
| 71 | S&F modular type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed. |
| 72 | S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed. |
| 73 | S&F LED light fitting 1x22W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. |
| 74 | S&F in replacement LED Bed light fittig luminaire of capacity 5 watt suitable to be fixed in wall complete all as specified and directed. |
| 75 | S&F in replacement LED recess mounting panels 2 feet x 2 feet luminaire of capacity 36 watt suitable to be fixed in ceiling having extruded aluminium frame and super bright LEDs complete all as specified and directed. |
| 76 | S&F in repairs of security light 36 watt, pressure die cast housing with epoxy powder coating, IP65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. |
| 77 | Supply and fixing ceiling fans (Copper winding) complete with blades, down rods and accessories, 230V, 1200mm sweep, min air delivery 210 CFM, BEE five star rated with brushless direct current motor(BLDC) with remote complete all as specified and directed. |
| 78 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 79 | S&F down rod suitable for ceiling fans for extension from ceiling of 1meter length complete all as specified and directed by Engr-in- Charge. |
| 80 | S&F in repairs of factory made epoxy polyester powder coated distribution board TP & N 4 way (TPN DB) double door (IP-43 protection) fabricated from minimum 2.0 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for TPN as incommer and outgoing MCBs as required at site complete all as specified and conforming to IS: 8623 along with cable end box complete all as specified and directed. NOTE :- (a) TPN and MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 81 | S&F in repairs of sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 82 | S&F 415V 10KA 'B' curve miniature circuit breaker (MCB) TPN of following poles and current carrying capacity in the DB complete with connection testing and commissioning of capacity 32 Amps complete all as specified and directed. |
| 83 | S&F in repairs of MCB SPN, 240 Volts, 40 Amps breaking capacity 10 KA complete all as specified and directed. |
| 84 | S&F in repairs of MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA complete all as specified and directed. |
| 85 | S&F in repair of sheet metal enclosure with a two pin and earth plug and socket with MCB 20 amps rated 240 volts complete all as specified and directed. |
| 86 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 1991 (Part-I) including taking out old existing earthing complete all as directed. |
| 87 | Supplying, laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of size 16 sqmm 4 core all as specified and directed. (Note :- Cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc complete all as specified and directed by Engr-in- Charge.) |
| 88 | Supplying, laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of size 10 sqmm 2 core all as specified and directed. (Note :- Cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc complete all as specified and directed by Engr-in- Charge. |
| 89 | Supply and fix electric water heater, storage type steel body with mild steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 90 | Supply and fixing for CPVC tubing nedium grade including all necessary fittings of size 16mm bore complete all as specified and directed. (Note- Rate quoted shall deemed to be included for making holes/nitch for fitting of puipe and making good disturbed surface to match with existing surface and finish all as directed.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender