Tender For Repair / Preventive Maintenance Of Transformers, Ht Ug Cables With Misc Items Under Ge (Af) Jamnagar No 1-- 1 Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Cwe (Af) Jamnagar Name Of Work:- Repair / Preventive Maint Of Transformers, Ht Ug Cables With Misc Items Under Ge (Af) Jamnagar No 1 Contract No: Cwe (Af) Jam / Ge-1 / Of 2024-2025 Serial Page No. Bidder Name : Schedule A (Price Schedule)(This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Srl.No. Item Description Item Code / Make Approx Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Basic Rate In Figures To Be Entered By The Bidder Rs. P Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Total Amount Incl Gst Total Amount With Taxes Total Amount In Words 2 Deployment Of Manpower And Cable Fault Locator Machine Duly Mounted On Vehicle For Detection Of Ht Ug Cable Fault Of Any Size & Make By Applying Upto 15 Kv Supply To Locate The Fault. Necessary Arrangements Required Should Be Provided By The Contractor. Note: Payment Under This Item Shall Be Measured And Made Only If Any Fault Is Detected. 3 Taking Out Ht Underground Cable From Trenches / Pole Etc, Aluminium Conductor Of Size 95 Sqmm 3 Core Complete All As Specified And As Directed. 4 Taking Out Ht Underground Cable From Trenches / Pole Etc, Aluminium Conductor Of Size 120 Sqmm 3 Core Complete All As Specified And Directed. 5 Taking Out Ht Underground Cable From Trenches / Pole Etc, Aluminium Conductor Of Size 240 Sqmm 3 Core Complete All As Specified And Directed. Note For Sl Item No 2 To 4 : Rates Includes Taking Out Old Cable, Cable Cover, Sorting Of Serviciable Items Etc. 6 Re-Laying / Re-Routing Old Taking Down Serviceable Ht Underground Cable From Trenches /Pole/Ducts Etc, Aluminium Conductor Of Size 95 Sqmm 3 Core All As Specified And Directed. 7 Re-Laying / Re- Routing Old Taking Down Serviceable Ht Underground Cable From Trenches /Pole/Ducts Etc, Aluminium Conductor Of Size 120 Sqmm 3 Core All As Specified And Directed. 8 Re-Laying / Re- Routing Old Taking Down Serviceable Ht Underground Cable From Trenches /Pole/Ducts Etc, Aluminium Conductor Of Size 240 Sqmm 3 Core All As Specified And Directed. 9 Supply, Laying, Jointing And Testing Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip, Heavy Duty, Ht Underground Cable Isi Marked With Aluminium Multistranded Conductor 11000 Volt Grade Of Size 95 Sqmm 3 Core Earthed Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting Complete All As Specified And As Directed. Note :-(I) Sand Cushioning, Cable Protection, Gi Protection Pipe, Clamps, Jointing Kits And Excavation & Earth Work Shall Be Measured & Paid For Separately.(Ii) Road Cutting/Floor Cutting /Cutting Holes Etc In Walls Required For Laying/Fixing Of Cable Etc Shall Be Made Good As Per Existing. Nothing Extra Shall Be Admissible On This Account. Quoted Rates Shall Be Inclusive Of The Above Provisions. 10 Supply, Laying, Jointing And Testing Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip, Heavy Duty, Ht Underground Cable Isi Marked With Aluminium Multistranded Conductor 11000 Volt Grade Of Size 120 Sqmm 3 Core Earthed Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting Complete All As Specified And As Directed. Note :-(I) Sand Cushioning, Cable Protection, Gi Protection Pipe, Clamps, Jointing Kits And Excavation & Earth Work Shall Be Measured & Paid For Separately.(Ii) Road Cutting/Floor Cutting /Cutting Holes Etc In Walls Required For Laying/Fixing Of Cable Etc Shall Be Made Good As Per Existing. Nothing Extra Shall Be Admissible On This Account. Quoted Rates Shall Be Inclusive Of The Above Provisions. 11 Supply, Laying, Jointing And Testing Xlpe Insulated, Pvc Inner Sheathed, Armoured With Galvanised Steel Strip, Heavy Duty, Ht Underground Cable Isi Marked With Aluminium Multistranded Conductor 11000 Volt Grade Of Size 240 Sqmm 3 Core Earthed Laid In Trenches / Duct Passing Through Pipe / Duct Or Fixed On Pole And Connecting Complete All As Specified And As Directed. Note :-(I) Sand Cushioning, Cable Protection, Gi Protection Pipe, Clamps, Jointing Kits And Excavation & Earth Work Shall Be Measured & Paid For Separately.(Ii) Road Cutting/Floor Cutting /Cutting Holes Etc In Walls Required For Laying/Fixing Of Cable Etc Shall Be Made Good As Per Existing. Nothing Extra Shall Be Admissible On This Account. Quoted Rates Shall Be Inclusive Of The Above Provisions. 12 M&L For Cable Jointing Kit For 11 Kv (Earthed) Grade Cable For Indoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 95 Sqmm Including Dismantling & Taking Out Old Unserviceable Jointing Kit, Complete All As Specified And As Directed. 13 M&L For Cable Jointing Kit For 11 Kv (Earthed) Grade Cable For Indoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 120 To 185 Sqmmsqmm T Including Dismantling & Taking Out Old Unserviceable Jointing Kit, Complete All As Specified And As Directed. 14 M&L For Cable Jointing Kit For 11 Kv (Earthed) Grade Cable For Indoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 240 Sqmm Including Dismantling & Taking Out Old Unserviceable Jointing Kit, Complete All As Specified And As Directed. 15 M & L For Cable Jointing Kit For 11 Kv (Earthed) Grade Cable For Straight Through Heat Shrink Type Joint Complete With Jointing Material Andaccessories Suitable For 3 Core Xlpearmoured Aluminium Conductor Cable Ofsize 95 Sqmm Including Dismantling & Taking Out Old Unserviceable Jointing Kit, Complete All As Specified And As Directed. 16 M & L For Cable Jointing Kit For 11 Kv (Earthed) Grade Cable For Straight Through Heat Shrink Type Joint Complete With Jointing Material Andaccessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size120 To 185 Sqmm Including Dismantling & Taking Out Old Unserviceable Jointing Kit, Complete All As Specified And As Directed. 17 M & L For Cable Jointing Kit For 11 Kv (Earthed) Grade Cable For Straight Through Heat Shrink Type Joint Complete With Jointing Material Andaccessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 240Sqmm Including Dismantling & Taking Out Old Unserviceable Jointing Kit, Complete All As Specified And As Directed. 18 M & L For Servicing Of Up To 160 Kva Capacity Transformer/Isolation Tr, 11 Kv / 433 V, By Disconnecting Lt / Ht Connections From Site Of Installation, Inspection/Assessing Of The Defective/Burnt Parts, Core Assembly Of Transformer In The Presence Of Engineer-In-Charge And Cleaning Complete For Making It Carbon Free, Checking For Any Loose Bushings & Making It Rectified If Found & Reconnecting With Lt / Ht Connections, Testing And Commissioning On Load Complete All As Specified And As Directed. (I) Filtration Of Transformer Oil If Required Will Be Measured & Paid Separately. (Ii) Topping Up With New Transformer Oil If Required Will Be Measured & Paid Separately.(Iii) Any Spare Part If Found Unserviceable Will Be Measured & Paid Separately And Minor Parts Such As Nuts, Bolts, Washers, Etc. Shall Be Arranged By The Contractor And The Cost Thereof Shall Be Deemed To Be Included In The Unit Rate Quoted Against This Item. 19 All As Per Item No 17 Above But 200 To 250 Kva Capacity Transformer 11 Kv / 433 V. 20 All As Per Item No 17 Above But 315 To 400 Kva Capacity Transformer 11 Kv / 433 V. 21 All As Per Item No 17 Above But 500 To 750 Kva Capacity Transformer 11 Kv / 433 V. 22 All As Per Item No 17 Above But 800 To 1000 Kva Capacity Transformer 11 Kv / 433 V. 23 S&F In Renewal Of 11 Kv Ht Terminal Comprising Stud, Insulator, Nut, Bolt, Washer Etc (For Three Phase) For Transformer Of Capacity Up To 250 Kva Complete All As Specified And As Directed. 24 S&F In Renewal Of 11 Kv Ht Terminal Comprising Stud, Insulator, Nut, Bolt, Washer Etc (For Three Phase) Suitable Type Transformer Of Capacity 315 To 400 Kva Complete All As Specified And As Directed. 25 S&F In Renewal Of 11 Kv Ht Terminal Comprising Stud, Insulator, Nut, Bolt, Washer Etc (For Three Phase) Suitable For Out Door/Indoor Type Transformer Of Capacity 500 To 1000 Kva Complete All As Specified And As Directed. 26 S&F In Renewal Of 0.433 Kv Lt Terminal Comprising Stud, Insulator, Nut, Bolt, Washer Etc (For Three Phase & Neutral) Suitable For Transformer Of Capacity Up To 250 Kva Complete All As Specified And As Directed. 27 S&F In Renewal Of 0.433 Kv Lt Terminal Comprising Stud, Insulator, Nut, Bolt, Washer Etc (For Three Phase & Neutral) Suitable For Transformer Of Capacity 315 To 400 Kva Complete All As Specified And As Directed. 28 S&F In Renewal Of 0.433 Kv Lt Terminal Comprising Stud, Insulator, Nut, Bolt, Washer Etc (For Three Phase) Suitable For Out Door Type Transformer Of Capacity 500 To 1000 Kva Complete All As Specified And As Directed. 29 Supply & Topping Up Of Transformer Oil Up To Required Level For Transformer / PtS / Stabilizers / Ht Switches Etc Of Duly Filtered With Filtration Plant To Obtain High Dielectric Strength 50 Kv & Above All As Per Is Specification, Complete All As Specified And As Directed. (Note : Transformer Oil Shall Be Supplied In Sealed Barrels With Test Certificate.) (Isi Marked). 30 Dehydration / Filtration Of Transformer Oil Of Transformers, Isolation Transformer, Ocbs, PtS, Oil Switches, Ring Main Tee Unit , Stabilizers Etc Of Various Capacities Installed At Different Locations By Disconnecting Plants Electrically For Recirculation Existing Transformer Oil With Trolley Mounted Filtration Plant Till Dielectric Strength Not Less Than 60 Kv.Note- Quoted Rates Shall Be Deemed To Include For Following :- (I) Oil Shall Be Tested After Filtration And Test Result Will Be Recorded Before & After Filtration Of Oil.(Ii) Contractor Should Make His Own Arrangement For Oil Filtration Plant Including Transportation Complete.(Iii) New Transformer Oil For Topping Up Will Be Measured And Paid In Relevant Item As Required.(Iv) All Necessary T&P / Testing Equipment Shall Be Provided By The Contractor At His Own Cost. No Extra Payment Shall Be Made To The Contractor. 31 Supply And Fix In Renewal Of Breather With First Quality Silica Gel Dehydrated For Transformer Of Capacity From 63 Kva To 1000 Kva Complete All As Specified And As Directed.(Note :- Size Of Breather Shall Be Provided As Per Oem Specification.) 32 Supply And Fix In Renewal Of Temperature Gauge Suitable For Transformer Of Capcity Up To 160 Kva Complete All As Specified And As Directed. 33 Supply And Fix In Renewal Of Temperature Gauge Suitable For Transformer Of Capcity Up To 200 Kva To 1000 Kva Complete All As Specified And As Directed. 34 Supply And Fix In Renewal Of Oil Level Gauge For Transformer Of Capacity From 63 Kva To 1000 Kva Complete All As Specified And As Directed. 35 M & L For Preparation Of Old Painted Surface Of Transformer Of Capacity 63 To 750 Kva, Including Connected Accessories Complete By Cleaning / Scraping Oil, Grease Dirt And Rust With Steel Wire Brush And Emery Paper To Obtain Clean And Smooth Surface, And Applying Two Coat Of Synthetic Enamel Paint As Per Mes Colour Code, Including Rewriting Of Mes No / Sl No Complete All As Specified And Directed. 36 Cutting, Trimming And Pruning Of Trees/Tree Branches/Creepers/Climbers Of All Around Sub Stn Up To 5 Feet Area Including Fencing/Boundry Wall And Cleaning The Disturbed Area Beneath And Removing The Tree Branches And Debris From Site And Depositing Outside Complete As Specified And Directed. (Girth Of Tree Not Less 30 Cm Measured 1M Above Gl.) 37 Material And Labour For Area Cleaning And Cutting Of Grass, Plants, Shrubs, Vegitations Using Grass Cutting Machine Or Mannually Within The Sub Statin Area Including Removal Of All Debries Complete All As Specified And Directed (Area Not Less Than 10 Sqm)Note:-(I) The Grass, Plants, Shrubs, Vegitation And Bushes Shall Not Be Allowed To Grow More Than 15 Cm From Hte Ground Level Of Any Time. 38 Supply And Spreading 40 Mm Size Graded Crushed Stone Aggregate On Ground Of Sub Station, Average Spreading Levelling Complete, All As Specified And Directed. Note: Measurement Shall Be Carried Out For Net Finished Volume Of Work Executed. 39 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out Soft/Loose Soil Complete All As Specified And As Directed. . 40 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Complete All As Specified And As Directed. 41 Removing Excavated Soil To A Distance N.Exc 50 M And Depositing Where Directed At A Level N.Exc 1.5M Above The Starting Point Complete All As Specified And As Directed. 42 M&L For Providing Dry River Sand As In Sand Cushioning Below And Above Cable Thickness As Specified In Ssr To Under Ground Cable Including Punning Down Of Sand In Layer Complete All As Specified And As Directed. (Note: For Measurement Purpose Punned Thickness Of Sand Will Be Considered.) 43 Laying Only Serviceable Pcc Cable Cover For Ht Ug Cable Of Any Type Complete All As Specified And As Directed. 44 Supply & Laying Isi Marked & Conforming To Is - 5820 - 1970 Unreinforced Precast Concrete Cable Cover Class Hv ,Type-1 Flat Of Size 300 Mm X 180 Mm X 40 Mm In Trenches As Protection To Ht Ug Cable Complete All As Specified And As Directed. 45 Supply And Laying In Renewal Of Gi Tubing 100 Mm Dia Bore Light Grade Laid In Trenches / Floor / Fixing On Pole / Wall For Cable Protection With Necessary Fittings Etc Including Taking Down Old Tubing Complete All As Specified And Directed. 46 M & L Ms Plates (Plain Or Chequered) Channels, Square Cut Or Notched (Ordinary And Counter Sunk) Forming Holes, Without Any Attachment Fe-290 (Gde E 165) Complete All As Specified And As Directed. 47 Material And Labour For Repair And Reconstruction Of Damaged Platform For Transformer Of Size 3.0 X 3.0 X 1.5M High From Gl Including Excavation In Trenches Not Less Than 1 Mtr, Pcc 1:5:10 Type E2 For Foundation, Brick Work In Cm 1:6, Pcc 1:2:4 Type B1 In Coping, Plaster 10Mm Thick In Cm 1:6 On Brick/Complete Surface Pcc 14:8 Type B1 Sub Base 75Mm Thick, As In Floor Pcc 1:2:4 Type B1 100Mm Thick Floor Using Extra Cement Returning Filling And Removal On Surplus Soil, Including 2 Nos Ismb 100Mm Channel Painting With 2 Coat Aluminium Paint Over A Coat Of Suitable Primer And 3 Coats Of White Washing On Cement Work For Fixing Transformer Including Ramp Of Suitable Size Mounting Of Transformer Complete All As Specified And As Directed. 48 Material And Labour For Shifting Of Transformer From 4 Pole Structure To Foundation Including Disconnecting Of Incoming And Outgoing Cables And Reconnecting The Same After Shifting Of Transformer Complete All As Specified And As Directed. 49 Material And Labour For Provision Of Earthing Complete With Galvanized Iron Earth Plate Electrode 600 Mm X 600 Mm X 6 Mm Thick Buried Directly In Ground (Earth Pit Not Less Than 2.25 M Deep Below Normal Ground Level) With Top Edge Of The Plate Not Less Than 1.5 M Deep Below Normal Ground Connected To Galvanised Mild Steel Strip 32 X 6 Mm By Means Of Bolts, Nuts, Check Nuts And Washer Of Galvanized Steel, Watering Pipe Of 20 Mm Bore Galvanised Iron Medium Grade And 40 Mm Bore Galvanised Iron Light Grade For Earth Strip Protection Including All Excavation, Earth Work In Any Type Of Soil, Pcc Pit In Pcc 1:2:4 Type B-1 And Rcc 1:2:4, Type B1 For Precast Chamber Cover 50 Mm Thick, Reinforced With Welded Steel Wire Fabric Or Xpm Jali (Weight Not Less Than 4.00 Kg / Sqm), With Charcoal, Salt, Funnel Complete All As Shown In The Electrical Plate No 3 Of Ssr Part –I And Testing On Completion. Note : (I) Earth Result After Installation Completely Should Be Less Than 5 Ohm .(Ii) Quoted Rates Shall Be Deemed To Include For Earth Strip With Protection Pipe Of 7.5 M Length. 50 Note For Above Srl Item No 1 To 48 :- (I) Work Shall Be Executed By The Authorised Service Mechanic/Electrician Of Manufacturer,After Satisfactorily Completion Of Servicing Of Ht Transformer/Vcb/Ht Breaker/Ht Tap Changer If Any Fault Occurs Upto The Completion Of Contract Should Be Attended By Concerned Rep Within Stripulated Time Frame Without Fail, Quoted Rates Is Deemed To Be Included All Such Charges. (Ii) If Any Above Ht Equipment And Connected Items Become Breakdown, The Contractor Shall Loacate The Problem/Fault At Site Within 12 Hours On Intimation By Je/Engineer-In-Charge And Ensure That The Fault To Be Rectified Within 48 Hours, Failing Which An Amount Of Rs 200 /- Per Hour Will Be Recovered As A Penal Recovery From Any Payment Due To Contractor After Expiry Of 48 Hours. (Iii) Minor Consumable Items, Ie Nuts, Bolts, Control Wires, Pvc Tapes, Welding Job, Cotton Waste & Cleaning Clothes, Petroleum Jelly, Grease, Lubricating Oil, Emery Paper, T & P Items Etc, Is To Be Arranged By Contracttor Without Any Extra Cost. Total In Figures 0.0 0.0 Inr Zero Only 4.0 Construction Of Chamber For 100Mm Sluice Plates Item5 10.0 Nos Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only Please Enable Macros To View Boq Information
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE (AF) Jamnagar NAME OF WORK:- REPAIR / PREVENTIVE MAINT OF TRANSFORMERS, HT UG CABLES WITH MISC ITEMS UNDER GE (AF) JAMNAGAR NO 1 Contract No: CWE (AF) JAM / GE-1 / of 2024-2025 SERIAL PAGE No. Bidder Name : SCHEDULE 'A' (PRICE SCHEDULE)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Srl.No. Item Description Item Code / Make Approx Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT INCL GST TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Deployment of manpower and cable fault locator machine duly mounted on vehicle for detection of HT UG cable fault of any size & make by applying upto 15 KV supply to locate the fault. Necessary arrangements required should be provided by the contractor. Note: Payment under this item shall be measured and made only if any fault is detected. |
| 3 | Taking out HT underground cable from trenches / pole etc, aluminium conductor of size 95 sqmm 3 core complete all as specified and as directed. |
| 4 | Taking out HT underground cable from trenches / pole etc, aluminium conductor of size 120 sqmm 3 core complete all as specified and directed. |
| 5 | Taking out HT underground cable from trenches / pole etc, aluminium conductor of size 240 sqmm 3 core complete all as specified and directed. Note for sl item no 2 to 4 : Rates includes taking out old cable, cable cover, sorting of serviciable items etc. |
| 6 | Re-Laying / Re-routing old taking down serviceable HT underground cable from trenches /pole/ducts etc, aluminium conductor of size 95 sqmm 3 core all as specified and directed. |
| 7 | Re-Laying / Re- routing old taking down serviceable HT underground cable from trenches /pole/ducts etc, aluminium conductor of size 120 sqmm 3 core all as specified and directed. |
| 8 | Re-Laying / Re- routing old taking down serviceable HT underground cable from trenches /pole/ducts etc, aluminium conductor of size 240 sqmm 3 core all as specified and directed. |
| 9 | Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt grade of size 95 Sqmm 3 core earthed laid in trenches / duct passing through pipe / duct or fixed on pole and connecting complete all as specified and as directed. Note :-(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. |
| 10 | Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt grade of size 120 Sqmm 3 core earthed laid in trenches / duct passing through pipe / duct or fixed on pole and connecting complete all as specified and as directed. Note :-(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. |
| 11 | Supply, laying, jointing and testing XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt grade of size 240 Sqmm 3 core earthed laid in trenches / duct passing through pipe / duct or fixed on pole and connecting complete all as specified and as directed. Note :-(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. |
| 12 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 13 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmmsqmm t including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 14 | M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 15 | M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material andaccessories suitable for 3 core XLPEarmoured aluminium conductor cable ofsize 95 sqmm including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 16 | M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material andaccessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 to 185 Sqmm including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 17 | M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material andaccessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240sqmm including dismantling & taking out old unserviceable jointing kit, complete all as specified and as directed. |
| 18 | M & L for Servicing of up to 160 KVA capacity transformer/Isolation TR, 11 KV / 433 V, by disconnecting LT / HT connections from site of installation, inspection/assessing of the defective/burnt parts, core assembly of transformer in the presence of Engineer-in-Charge and cleaning complete for making it carbon free, checking for any loose bushings & making it rectified if found & reconnecting with LT / HT connections, testing and commissioning on load complete all as specified and as directed. (i) Filtration of transformer oil if required will be measured & paid separately. (ii) Topping up with new transformer oil if required will be measured & paid separately.(iii) Any spare Part if found unserviceable will be measured & paid separately and minor parts such as nuts, bolts, washers, etc. shall be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. |
| 19 | All as per item No 17 above but 200 to 250 KVA capacity transformer 11 KV / 433 V. |
| 20 | All as per item No 17 above but 315 to 400 KVA capacity transformer 11 KV / 433 V. |
| 21 | All as per item No 17 above but 500 TO 750 KVA capacity transformer 11 KV / 433 V. |
| 22 | All as per item No 17 above but 800 TO 1000 KVA capacity transformer 11 KV / 433 V. |
| 23 | S&F in renewal of 11 KV HT terminal comprising stud, insulator, nut, bolt, washer etc (for three phase) for transformer of capacity up to 250 KVA complete all as specified and as directed. |
| 24 | S&F in renewal of 11 KV HT terminal comprising stud, insulator, nut, bolt, washer etc (for three phase) suitable type transformer of capacity 315 to 400 KVA complete all as specified and as directed. |
| 25 | S&F in renewal of 11 KV HT terminal comprising stud, insulator, nut, bolt, washer etc (for three phase) suitable for out door/indoor type transformer of capacity 500 to 1000 KVA complete all as specified and as directed. |
| 26 | S&F in renewal of 0.433 KV LT terminal comprising stud, insulator, nut, bolt, washer etc (for three phase & neutral) suitable for transformer of capacity up to 250 KVA complete all as specified and as directed. |
| 27 | S&F in renewal of 0.433 KV LT terminal comprising stud, insulator, nut, bolt, washer etc (for three phase & neutral) suitable for transformer of capacity 315 to 400 KVA complete all as specified and as directed. |
| 28 | S&F in renewal of 0.433 KV LT terminal comprising stud, insulator, nut, bolt, washer etc (for three phase) suitable for out door type transformer of capacity 500 to 1000 KVA complete all as specified and as directed. |
| 29 | Supply & topping up of transformer oil up to required level for transformer / PT's / stabilizers / HT switches etc of duly filtered with filtration plant to obtain high dielectric strength 50 KV & above all as per IS specification, complete all as specified and as directed. (Note : Transformer oil shall be supplied in sealed barrels with test certificate.) (ISI Marked). |
| 30 | Dehydration / filtration of transformer oil of transformers, isolation transformer, OCBs, PT's, oil switches, Ring main Tee unit , Stabilizers etc of various capacities installed at different locations by disconnecting plants electrically for recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength not less than 60 KV.Note- Quoted rates shall be deemed to include for following :- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil.(ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.(iii) New Transformer oil for topping up will be measured and paid in relevant item as required.(iv) All necessary T&P / testing equipment shall be provided by the contractor at his own cost. No extra payment shall be made to the contractor. |
| 31 | Supply and fix in renewal of breather with first quality silica gel dehydrated for transformer of capacity from 63 KVA to 1000 KVA complete all as specified and as directed.(Note :- Size of breather shall be provided as per OEM specification.) |
| 32 | Supply and fix in renewal of temperature gauge suitable for transformer of capcity up to 160 KVA complete all as specified and as directed. |
| 33 | Supply and fix in renewal of temperature gauge suitable for transformer of capcity up to 200 KVA to 1000 KVA complete all as specified and as directed. |
| 34 | Supply and fix in renewal of oil level gauge for transformer of capacity from 63 KVA to 1000 KVA complete all as specified and as directed. |
| 35 | M & L for preparation of old painted surface of transformer of capacity 63 to 750 KVA, including connected accessories complete by cleaning / scraping oil, grease dirt and rust with steel wire brush and emery paper to obtain clean and smooth surface, and applying two coat of synthetic enamel paint as per MES colour code, including rewriting of MES No / Sl No complete all as specified and directed. |
| 36 | Cutting, trimming and pruning of trees/tree branches/creepers/climbers of all around Sub Stn up to 5 feet area including fencing/boundry wall and cleaning the disturbed area beneath and removing the tree branches and debris from site and depositing outside complete as specified and directed. (Girth of tree not less 30 cm measured 1m above GL.) |
| 37 | Material and labour for area cleaning and cutting of grass, plants, shrubs, vegitations using grass cutting machine or mannually within the sub statin area including removal of all debries complete all as specified and directed (Area not less than 10 sqm)Note:-(i) The grass, plants, shrubs, vegitation and bushes shall not be allowed to grow more than 15 Cm from hte ground level of any time. |
| 38 | Supply and spreading 40 mm size graded crushed stone aggregate on ground of sub station, average spreading levelling complete, all as specified and directed. Note: Measurement shall be carried out for net finished volume of work executed. |
| 39 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed. . |
| 40 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 41 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 42 | M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer complete all as specified and as directed. (Note: for measurement purpose punned thickness of sand will be considered.) |
| 43 | Laying only serviceable PCC cable cover for HT UG cable of any type complete all as specified and as directed. |
| 44 | Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class HV ,type-1 flat of size 300 mm X 180 mm X 40 mm in trenches as protection to HT UG cable complete all as specified and as directed. |
| 45 | Supply and laying in renewal of GI tubing 100 mm dia bore light grade laid in trenches / floor / fixing on pole / wall for cable protection with necessary fittings etc including taking down old tubing complete all as specified and directed. |
| 46 | M & L MS plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 (Gde E 165) complete all as specified and as directed. |
| 47 | Material and labour for repair and reconstruction of damaged platform for transformer of size 3.0 x 3.0 x 1.5m high from GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 type B1 in coping, plaster 10mm thick in cm 1:6 on brick/complete surface PCC 14:8 type B1 sub base 75mm thick, as in floor PCC 1:2:4 type B1 100mm thick floor using extra cement returning filling and removal on surplus soil, including 2 Nos ISMB 100mm channel painting with 2 coat aluminium paint over a coat of suitable primer and 3 coats of white washing on cement work for fixing transformer including ramp of suitable size mounting of transformer complete all as specified and as directed. |
| 48 | Material and labour for shifting of transformer from 4 pole structure to foundation including disconnecting of incoming and outgoing cables and reconnecting the same after shifting of transformer complete all as specified and as directed. |
| 49 | Material and labour for provision of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised mild steel strip 32 x 6 mm by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note : (i) Earth result after installation completely should be less than 5 Ohm .(ii) Quoted rates shall be deemed to include for earth strip with protection pipe of 7.5 M length. |
| 50 | Note for above Srl Item No 1 to 48 :- (i) Work shall be executed by the authorised service mechanic/Electrician of manufacturer,After satisfactorily completion of servicing of HT Transformer/VCB/HT Breaker/HT Tap changer If any fault occurs upto the completion of contract should be attended by concerned rep within stripulated time frame without fail, quoted rates is deemed to be included all such charges. (ii) If any above HT Equipment and connected items become breakdown, the contractor shall loacate the problem/fault at site within 12 hours on intimation by JE/Engineer-In-Charge and ensure that the fault to be rectified within 48 Hours, failing which an amount of Rs 200 /- per hour will be recovered as a penal recovery from any payment due to contractor after expiry of 48 hours. (iii) Minor consumable items, ie Nuts, bolts, Control wires, PVC tapes, Welding Job, cotton waste & cleaning clothes, petroleum jelly, grease, lubricating oil, emery paper, T & P items etc, is to be arranged by contracttor without any extra cost. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |