Tender For Special Repair To Bldg No. T-32 & T-35 Of 4 Maratha Li, Bldg No. T-15 Of 327 Fd Regt, Bldg No T-87 Of 8 Mahar At Dras Under Ge Kargil
Tender Value
41.65 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
9 days left
EMD
83300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kargil → Jammu And Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No. T-32 & T-35 Of 4 Maratha Li, Bldg No. T-15 Of 327 Fd Regt, Bldg No T-87 Of 8 Mahar At Dras Under Ge Kargil
BOQ
| Sl. No. | Item Description |
| 1 | Dismantiling of plain corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed. |
| 2 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 3 | S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 4 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. |
| 5 | Demolition of Cement Concrete (unreinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) complete all as specified and as directed. |
| 6 | M&L for cement concrete type C-2 1:3:6, 75 mm thick as in plinth protection in floor and finishing surface even and smooth without using extra cement complete all as specified & directed. |
| 7 | M&L for cement concrete type C-2 1:3:6, 75 mm thick as in sub base in floor complete all as specified & directed. |
| 8 | M&L for pre-polished cut kota stone slab flooring 20-25mm thick over 20 mm thick screed bed in CM 1:4 laid over cement slurry, pointed and jointed with grey mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed |
| 9 | M&L Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.11 and n.exc 0.38 Sqm in floors over 15mm thick screed bed in cement mortar 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed |
| 10 | M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over 25mm thick sand cushion complete all as specified and directed . (Note- Sand cushion measured and paid seperately) |
| 11 | M&L for sand filling under floors or in foundation including watering and consolidation all as specified and as directed |
| 12 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/blankets, any thickness, including cover fillets all as specified and as directed. |
| 13 | S&F in repairs 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails on wall to timber frame work complete, all as specified and directed |
| 14 | S&F in repairs 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails on ceiling to timber frame work complete, all as specified and directed |
| 15 | Dismantling timber scantlings as in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in framed work, in any position complete, all as specified and directed. |
| 16 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed |
| 17 | M&L for Plain fillets of second class soft wood (KAIL), sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed |
| 18 | M&L for Plain fillets of second class soft wood (KAIL), sectional area not exc 3 Sqcm in square, rectangular or traingular in section, bullnosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed |
| 19 | Taking down shutters of any description exc 1.00 Sqm but not exc 2.00 Sqm each. |
| 20 | Taking down chowkats or frames not exc 1.5 Sqm with shutters (without taking off shutters from the frames) each. |
| 21 | S&F Anodised aluminium frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as specifiedand directed by Engineer-in-Charge. |
| 22 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as specified and directed by Engineerin- charge. |
| 23 | S&F 5mm thick sheet glass, oridinary quality and glazing oil putty in square exc 0.50sqm in each pan complete all as specified and directed. |
| 24 | S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified. |
| 25 | S&F 150mm long Aluminium anodisedl barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 26 | S&F 200mm long Aluminium anodisedl barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 27 | S&F 75mm mild steel butt hinges medium weight , cold rolled complete all as specified and as directed by Engr-in-Charge |
| 28 | S&F 100mm mild steel butt hinges medium weight , cold rolled complete all as specified and as directed by Engr-in-Charge |
| 29 | S&F 125mm extruded aluminium alloy handles fabricated type anodised complete all as specified and as directed |
| 30 | S&F 150mm extruded aluminium alloy handles fabricated type anodised complete all as specified and as directed |
| 31 | S&F 300mm aluminium alloy, anodised,sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed. |
| 32 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 33 | S&F in repair Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat ections) including distance pieces, cleats etc complete all as specified & directed. |
| 34 | M&L for 1.25mm thick plain black mild steel sheeting in chajjas and straight flashings complete all as specified and directed. |
| 35 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 36 | M&L for preparing old painted surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 37 | Demolition of Brickwork or stone/boulders masonry built in cement mortar complete all as specified and as directed by the Engr-in-charge |
| 38 | M&L for precast cement concrete type C1 1:3:6 (using 20mm graded aggregate) block masonry with soild block, exc 10cm width and setting in cement mortor 1:6 complete all as specified and as directed by Engr-in-Charge |
| 39 | M&L rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 40 | M&L for preparation of new wall surfaces and applying two or more coats of premium acrylic exterior emulsion paint over a coat of wall care putty all as specified. |
| 41 | Dismantling water storage tanks of capacity exc 500 & n.exc 1000 ltrs and removing to store complete all as specified and as directed |
| 42 | Supply and fixing rotational moulded polyehtylene water storage puf tank of 1000 ltrs capacity complete all as specified and directed by Engr-in-Charge |
| 43 | Taking up or down steel water tubing of 20mm dia bore and connection incl cleaning for refixing or removal to stores all as specified and as directed |
| 44 | Taking up or down steel water tubing of 25mm dia bore and connection incl cleaning for refixing or removal to stores all as specified and as directed |
| 45 | M&L for 20mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. |
| 46 | M&L for 25mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc. |
| 47 | S&F in repairs vitreous china wash hand basin (flat black) white of size 550x400mm with pedestal including waste coupling & waste pipe and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size all as specified. |
| 48 | S&F in repair 15mm bore Pillar taps cast copper ally, with capstain head, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed |
| 49 | S&F in repair 15mm Stop valve/angle cock, fancy type, chromium plated with long shunk and cup (concealed type) high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed |
| 50 | M&L for 20mm thick coloured granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixtureof pigment to match with shade of granite complete all as specified and directed. |
| 51 | M & L for 25 mm thick plain cement concrete type B-0 (12.5mm graded stone aggregate) 1:2:4 as in floor complete all as specified and directed. |
| 52 | S&F 35 mm thick 1st class soft wood (KAIL) plain framed panelled shutter (any number of panels) with panels of timber flat on both sides (Feather edge) or of veneered particle board medium density wood particle board with commercial face veneers and fitted to chowkhat complete all as specified and directed. |
| 53 | S&F 30 mm 2nd class softwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 54 | S&F in repairs galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples including etc complete all as specified. |
| 55 | Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed. |
| 56 | S&F 4.8mm thick glass pan ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed. |
| 57 | S&F 100 mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 58 | S&F 100mm extruded aluminium alloy handles fabricated type anodised complete all as specified and as directed |
| 59 | M&L for preparation of new surface of wood and wood based material surface of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 60 | S & F 2nd class soft wood plain, solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and directed. |
| 61 | S&F 0.63mm thick, galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with self tapping screw or L-type or J-type or crancked hook bolts and washers as in roofs, walls etc, with grade of zinc coating 275, complete all as specified and directed |
| 62 | All as per item No 61 here-in-before but except sheet. |
| 63 | M & L for endura tiles, heavy duty type of size 300x300mm, 10mm thick, non skid, acid and scratch resistance laid over 15mm thick screed bed in CM 1:4 as in floor, jointed in neat cement slurry and pointed with white cement and pigment to match the shade completed all as specified and as per direction of manufacturer instuctions / Engr in charge |
| 64 | S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 65 | S&F steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete all as specified and directed. |
| 66 | Hacking out old broken glass (any thickness,size,quality or description) from wooden frames metal frames or stone,concrete or brick surrounds,glazed with putty or fixed with beads complete all as specified and directed. |
| 67 | S&F 3mm thick glass pan ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane |
| 68 | Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches ceiling roses, pendants, sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 69 | M&L for Point wiring for light/fan/bell with FRLS cable of 1.5sqmm PVC insulated (red/blue/yellow for phase, black for neutral and green for earth) unsheathed multistranded copper conductor 1100 volts grade in and including not less than 2mm thick PVC casing caping with all accessories and 1.5sqmm green in colour PVC insulated multistranded copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS/GI sunken box with 3mm thick pre laminated hylum sheet/PVC box with back plate,flush/surface type for mounting fittings such as switches,socket,and regulator complete all as specified and directed for one light point or bell/buzzer point controlled by one switch. |
| 70 | All as per Srl item No 69 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 5 Amps independent board. |
| 71 | All as per Srl item No 69 here in before but using cable size 2.5 Sqmm for one 3 pin socket outlet 15 Amps independent board. |
| 72 | S&F in replacement of Switch piano flush type 5 Amps, single pole one way complete all as specified and directed by engr-in-charge. |
| 73 | S&F in replacement of Switch socket combination 2 in 1, and 3 and 2 pin, 5 Amps flush type complete all as specified and directed by engr-in-charge. |
| 74 | S&F in replacement of Switch socket combination 2 in 1,3 pin, 5 and 15 Amps flush type complete all as specified and directed by engr-in-charge. |
| 75 | S&F in replacement of in Ceiling rose on PVC Square Block surface bakelite 65x50mm, two to three terminals complete all as specified and directed by engr-in-charge. |
| 76 | Supply and fixing in replacement of LED white colour 1x18 Watt, 220 V, AC, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use, connecting up with two/three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 77 | Supply and fixing in replacement LED luminarie 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete 6000K/3000K with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as speicifed and directed. |
| 78 | S&f in replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by engr-in-charge. |
| 79 | Supply and fixing in replacement of LED bulb 09 watt, 230 volts complete all as specified and directed by engr-in-charge. |
| 80 | S & F in replacement of Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 08 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 81 | S & F in replacement of Sheet metal enclosure for DB's Double door, single pole and neutral, 240V, 12 way with 200 Amp rated bus bar including blanking plates where required. Complete all as specified and directed. |
| 82 | Supply and fixing in replacement of 240 V 10 KA C curve miniature circuit breaker (MCB) SPN 40 to 63 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by engr-in-charge. |
| 83 | Supply and fixing in replacement of 240 V 10 KA C curve miniature circuit breaker (MCB) SP 5 to 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by engr-in-charge. |
| 84 | S&F in replacement of LED light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up three core flexible copper conductor cable of suitable size complete all as specified and directed by engr-in-charge. |
| 85 | S & Fix in replacement of LED Flood light fitting 70 watt 5000 k green/natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed. |
| 86 | M&L in replacement of submain wiring comprising single core, 2 Runs of 6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including min 25mm dia. PVC conduit/ PVC Casing Caping ISI Marked(heavy duty) and its fittings on surface/recessed complete including provision of 1X6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS complete all as specified and directed by Engr-In-charge.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 87 | Supply and fix in replacement of exhaust fan, steel body, AC single phase, 230 V of size 300 mm sweep with blades and frame and louvers including cutting of hole into wall of suitable size including fixing of plyboard and making the surface good complete all as specified and directed by engr-in-charge. |
| 88 | S&F in replcement of 1100 volts grade heavy duty 16 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended complete all as specified and directed by engr-in-charge. |
| 89 | Dismantling and M&L for Earthing complete with galvanised steel earth plate electrode of size 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI iron wire of size 4 mm dia by means of GI bolts, nuts, check nuts and washers, protected by 15mm bore GI light grade ISI marked pipe upto and including test points. Earth plate shall be surrounded by alternate layer 15cm thick of charcoal or coke and common salt all around bottom and top , 20cm bore GI medium grade ISI marked pipe for watering and including funnel,wire mesh,PCC chamber pit made with PCC(1:3:6) type C-1(using 20mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50M, CI pit cover duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No.3 of SSR 2009(Part-I) and all as directed.Note:- (i) Protection pipe and earthing strip upto test point from top of the earth plate and further upto the body of electrical equipment shall be included in the unit rate of this item.(ii) Earth testing arrangement should be done by contractor as per direction of Engr-In-Charge. |
| 90 | Note : Deduction for amount of Rs. 1,16,265.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysJul 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender