Tender for Miscellaneous Repair of otm Accn Under age B/r(m) at Faridkot mil stn
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing to low lying area within station where directed complete. |
| 2 | Water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :-(a) Cleaning of sunen portion and roughining to receive treatment.(b) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces (Note : WPC shall be measured and paid separately)(c) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer.(d) Provide a layer glass fibre mesh of size 2.25mm x2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation.(e) Applying second coat of chemical Pidifin 2K (Dr Fixit) / eqivalent @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers.Note: The plan area of floor shall be considered for payment. |
| 3 | M&L for broken brick bats 40 to 80mm as in filling of sunken floors etc. |
| 4 | M&L 25mm thick PCC 1:2:4 type B0 (12.5mm graded aggregate) with WPC under floor over sunken complete all as specified and directed |
| 5 | PCC (1:3:6) type C-2 (using 40mm graded agg) 50mm thick as in plinth protection and floors including making grooves. |
| 6 | Demolition of RCC of any descrition such chajja, shelves etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge and removing waste material to low lying area within station where directed complete. |
| 7 | M&L for reinforced cement concrete type B1 1:1.5:3 (20 mm graged aggregate) as in Slab supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and etc. and setting in mortar complete with joints to match complete all as specified |
| 8 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified |
| 9 | Use and waste of form work torough finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick and in beams/columns etc. |
| 10 | Taking up or down GI/CPVC/any other tubing 15mm bore pipe incl removing to MES store complete. |
| 11 | Taking up or down GI/CPVC/any other tubing 20mm bore pipe incl removing to MES store complete. |
| 12 | Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings and all other Brass fittings required except given in item number 18,19,20 & 21 on walls/ceiling or laying in floors complete including cutting chases in wall, floors etc and their making good in case of concealed pipe work all as specified. bore of pipe 20mm complete all as specified and directed by Engr-in-Charge. |
| 13 | Supplying and laying of 25mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings and all other Brass fittings required except given in item number 18,19,20 & 21 on walls/ceiling or laying in floors complete including cutting chases in wall, floors etc and their making good in case of concealed pipe work all as specified. bore of pipe 20mm complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F GI tubing 15 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, including cutting chases in wall, floors etc and their making good in case of concealed pipe work complete all as specified. |
| 15 | S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, including cutting chases in wall, floors etc and their making good in case of concealed pipe work complete all as specified. |
| 16 | S&F of 20 mm inner dia CPVC Brass Male/ Female Brass Threaded Adaptor fittings complete all as specified. |
| 17 | S&F of 20 mm inner dia CPVC Brass Elbow fittings complete all as specified |
| 18 | S&F of 20 mm inner dia CPVC Brass T fittings complete all as specified |
| 19 | S&F of 20 mm inner dia CPVC Brass Union fittings complete all as specified |
| 20 | M&L Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed with adhisive with same make of tiles and pointed with epoxy grouting to match the coloured tiles over 15mm thick screed bed or bedding layer CM 1:4 for laying finishes,complete all as specified as directed by Engr-in- Charge. Note :- (i) Adhisive measured and paid seprately (ii) Epoxy grouting rate including respective items |
| 21 | M&L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, cut to reqd size and shape as in skirtings etc. set and jointed adhisive with same make of tiles and pointed with epoxy grouting match coloured over and incl 10mm thick redering in CM 1:4. for laying finishes,complete all as specified as directed by Engr-in- Charge. Note :- (i) Adhisive measured and paid seprately (ii) Epoxy grouting rate including respective items |
| 22 | M&L double charge vitrified tiles 9-10mm thick (square/rectangle) (light shade) area of each tile exc 0.18 sqm and not exceeding 0.38 sqm, as in floor set with readymade tile adhesive keeping 3-4 mm wide joints to be filled apoxy grout of approved colour over 15mm thick screed bed or bedding layer of CM 1:4 for laying finishes, complete all as specified as directed by Engr-in-Charge. Note: (i) cost of epoxy grout shall deemed to be included in coted rates. (ii) Readymade tiles adhesive shall be measured and paid seperately@ 2.4 kg/sqm area of thiles in respective items. |
| 23 | M&L double charge vitrified tiles 9-10mm thick (square/rectangle) (light shade) area of each tile exc 0.18 sqm and not exceeding 0.38 sqm, as in skirting set with readymade tile adhesive keeping 3-4 mm wide joints to be filled apoxy grout of approved colour over 15mm thick screed bed or bedding layer of CM 1:4 for laying finishes, complete all as specified as directed by Engr-in-Charge. Note: (i) cost of epoxy grout shall deemed to be included in coted rates. (ii) Readymade tiles adhesive shall be measured and paid seperately@ 2.4 kg/sqm area of thiles in respective items. |
| 24 | M&L Glazed ceramic coloured tiles in vertical surface 450x300x7mm or 600x300x7mm thick set and jointed with adhisive same make of tiles and pointed with epoxy grouting match to colour including 15 mm thick rendering in CM 1:4 on other than fair face of brick work. Note :- (i) Adhisive measured and paid seprately (ii) Epoxy grouting rate including respective items |
| 25 | Dismantling floor, hearth or wall tiling including cement mortar bedding , terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing and removing debris to low lying area within station where directed complete. |
| 26 | Dismantling stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar and removing debris to low lying area within station where directed complete. |
| 27 | M&L Granite (of any type) work 15 to 17 mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. all as specified |
| 28 | M&L Green/black marble work 15 to 17 mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. all as specified |
| 29 | M&L Machine cut kota stone slab flooring 18-20mm thick over and incl 15mm thick, 1:6 cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeall as specified.Note : Single peice slab to be provided in steps and stairs. |
| 30 | M&LKota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over 10mm cement screed 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeall as specified.Note : Single peice slab to be provided in steps and stairs. |
| 31 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations |
| 32 | S&F in repair Rotational moulded polythylene 500 ltr capacity water storage tank (Cylindrical vertical with closed top) white colour, hoisted and fixed in position including 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. & dismantling of old water tank and removing to MES store complete all as specified. |
| 33 | S&F in repair Rotational moulded polythylene 1000 ltr capacity water storage tank (Cylindrical vertical with closed top) white colour, hoisted and fixed in position including 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. & dismantling of old water tank and removing to MES store complete all as specified. |
| 34 | Dismanteling and Re-fixing only in repair Rotational moulded polythylene 500 ltr capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. |
| 35 | Dismanteling and Re-fixing only in repair Rotational moulded polythylene 1000 ltr capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. |
| 36 | S&F in repairs 20mm gun metal globe or gate valve with iron wheet head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 37 | S & F in repair 15 mm bore ISI marked Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) |
| 38 | S & F in repair 15 mm bore ISI marked stop valve of PTMT any colour high pressure screwed for iron pipe but with long shank and cup (concealed type), (Minimum weight 15mm-110gms) |
| 39 | S & F in repair 20 mm bore ISI marked stop valve of PTMT any colour high pressure screwed for iron pipe but with long shank and cup (concealed type), (Minimum weight 20mm-112gms) |
| 40 | S & F PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality complete all as specified |
| 41 | S & F in repair 15 mm bore ISI marked Pillar taps of PTMT any colour high pressurescrewed for iron pipe and fixed.(Minimum weight 15mm-110gms |
| 42 | S & F in repair 15 mm bore ISI marked long body bib taps of PTMT any colour high pressurescrewed for iron pipe and fixed.(Minimum weight 15mm-120gms |
| 43 | S & F in repair Brass CP single lever central hole basin mixer for mixing hot & cold water screwed down for iron pipe and fixed |
| 44 | S & F in repair Brass CP telephonic wall / sink mixer for mixing hot & cold water screwed down for iron pipe and fixed |
| 45 | S & F in repair Health faucet (ABS body) mild steel chromium plated incl 1.25m long flexible CP tube and wall hook. |
| 46 | S & F in repair brass chromium plated shower rose 125mm incl 15mm bore CP shower arm complete. |
| 47 | S&F in repair vitreous china wash hand basin, white, flat back of size 550mm x 400mm including cantiliver CI/angle iron brackets, CP brass waste coupling 32mm bore with rubber washer and PVC waste pipe 32mm bore complete all as specified and directed . |
| 48 | S&F in repair vitreous china counter wash basins, size 470x470mm white to be fixed with and incl granite & RCC slab including cutting for and pinning in ends of brackets or erecting stand, including 32mm waste fittings, waste pipe, chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed. |
| 49 | S&F in repair vitreous china urinal ,size 375x390x590mm cat no S4020112 of cera or equivalent , white,incl waste coupling and waste pipe of PTMT including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement mortar, including connections to flushing pipe and outgoing pipes complete all as specified & directed . |
| 50 | S & F in repairs vitreous China one piece WC (Floor mounted or wall hung type) of approved make including soft close seat cover and CP jet spray complete. |
| 51 | S & F in repairs vitreous China squatting pan or Orrissa pattern of approved make of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl concrete bedding and connection to antisyphonage pipe etc including making good to floor. |
| 52 | S & F in repairs vitreous China EWC wash down water closet (Pedestal pattern) incl seat cover and PTMT spray jet incl connection to trap and to flushing pipe etc complete. |
| 53 | M&L for 100 mm dia of long body PVC 'P' or 'S' trap incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 in repair complete all as specified. |
| 54 | S & F PVC low level cistern of 10 ltrs capacity with top push buttion inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved make. |
| 55 | Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc including cleaning or refixing or removal to store(measured overall as fixed along the centre line over fittings and accessories) |
| 56 | Dismantling and disconnecting existing CI / PVC soil waste/vent pipe 100/75 mm bore fixed to wall,laid in trenches incl all fittings & accessories and removing debris to low lying area within station where directed and scrap to MES store complete. |
| 57 | S & F 110 mm bore of pipe PVC (SWR) pipes Grade B single socket in any length with rubber ring joint laid in floor/trench incl covered with PCC 1:2:4 or fixed to walls with and including GI clamps at distence of 2m c/c complete all as specified and directed. |
| 58 | ditto but for 75mm bore pipe. |
| 59 | S & F 110 mm bore PVC (SWR) bends heavy grade with/without access door as per site requirement of any radius / shoe fixed to PVC pipes as directed |
| 60 | S & F 75 mm bore of pipe PVC (SWR) bends heavy grade with/without access door as per site requirement of any radius / shoe fixed to PVC pipes as directed |
| 61 | M&L for 75mm dia of long body PVC Floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 in repair complete all as specified. |
| 62 | M&LPVC (SWR) branch piece,single (single Y),75 mm bore, (equal or unqual), with access door complete all as specified and directed by Engineer-in-Charge. |
| 63 | M&LPVC (SWR) branch piece,single (single Y),100 mm bore, (equal or unqual), with access door complete all as specified and directed by Engineer-in-Charge. |
| 64 | M&L PVC (SWR) junction single,(Single T), 75 mm bore, (equal or unqual), ordinary or inverted (spigot or socket type) with/without access door as per site requirement as in repairs complete all as specified and directed by Engineer-in-Charge. |
| 65 | M&L PVC (SWR) junction single,(Single T), 100 mm bore, (equal or unqual), ordinary or inverted (spigot or socket type) or with/without access door as per site requirement as in repairs complete all as specified and directed by Engineer-in-Charge. |
| 66 | S&F in repairs PVC (SWR) vent cowl 100 mm complete all as specified and directed |
| 67 | S&F in repairs PVC (SWR) vent cowl 75 mm complete all as specified and directed |
| 68 | S&F Salt-glazed stoneware gully traps 150x 150 mm , square or round mouthed, tvpe 'P |
| 69 | S & F 100 mm bore cast iron soil waste and vent pipes in any length with or without ears, with cement joints, laid in floor incl covered with PCC 1:2:4 or fixed to walls with and incl GI clamps at distence of 2m c/c . |
| 70 | ditto as above but for 75mm bore pipe. |
| 71 | S & F 100 mm bore CI bend (any radius), diminishing piece or tapers with or without ovel access door. |
| 72 | S & F 75 mm bore CI bend (any radius), diminishing piece or tapers with or without ovel access door. |
| 73 | S&F 100 mm bore CI branch piece, Tee, Cross (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches with or without oval access door complete all as specified and directed by Engineer-in-Charge. |
| 74 | S&F 75 mm bore CI branch piece, Tee, Cross (equal or unqual), ordinary or inverted (spigot or socket type) or with parallel branches with or without oval access door complete all as specified and directed by Engineer-in-Charge. |
| 75 | S&F in repair 125 mm dia round / square grating of stainless steel with or without holewith white cement complete all as specified & directed by Engineer-in- charge. |
| 76 | Taking down Cement plaster/ Grit finish/rough cast plaster including raking out joints hacking for key scrubbing down with water etc and removing debris to low lying area within station where directed complete. |
| 77 | M&L for 10-15 mm thick ready mix mortar other than fare face of brick work or concrete surfaces and finishing the surface even & fair complete. |
| 78 | Supply only adhishiv for fixing of tiles in floor and wall |
| 79 | M&L for rendering 5mm thick ready mix plaster on ceiling all as specified and as directed. |
| 80 | M&L for repair of deteriorated concrete surface like RSS slab, Fins, Projections, beams and columns etc by applying cement mortar 1:3, 15mm to 20mm thick in one or two layers over a coat of neat cement slurry @ 3kg/sqm over one coat of bonding agent on RCC deteriorated surface as per manufacturers specifications after chipping of loose concrete and cleaning the surface with air blower complete incl all necessary scaffolding upto 15m height all as specified and directed.Make: Dr Fixit URP , Fosroc Nitobond, Sikka Hibond. Note : Work to be executed in very small patches in different locations. Repaired surface to be finished with adjoining surface finish. |
| 81 | M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion white/tinted over a coat of wall care putty finished even and smooth surface by hand roller complete all as specified and directed by Engr -in - charge. |
| 82 | M&L for preparation of surfaces and applying two coat of white wash on newly plastered surface of ceiling etc complete all as specified. |
| 83 | M&L for preparation of new surfaces and applying two coat of cement base paint complete all as specified.Note :- Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I |
| 84 | Dismantling of brickwork built in cement mortar of any description complete all as specified and directed as per Engineer-In-Charge |
| 85 | M&L brick work with Fly ash bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge. |
| 86 | M&L for hard core of gauge not exceeding 63mm using broken stone or boulders, deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed . |
| 87 | M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base,paving etc complete all as specified and directed . |
| 88 | M&L repair to RCC fillet beams in ceiling with cement mortar 1:3 over applying a coat of bonding agent as per manufacturers specifications complete all as specified and directed Make: Dr Fixit URP , Fosroc Nitobond, Sikka Hibond |
| 89 | M&L PCC 1:2:4 type B0 using (12.5 mm graded aggregate) as in roof kerbs, under RWP, incl rounded or chamfered etc complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 90 | M&L PCC 1:2:4 type B0 using (12.5 mm graded aggregate) as in roof kerbs, under RWP, incl rounded or chamfered etc complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysJul 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender