Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56240318

Tender For Special Repair To Bldg No P-31 At Gm Vihar Under Ge (N) Akhnoor.

Issued by Statutory Bodies & Commissions/Committees · akhnoor, Jammu and Kashmir
Tender Value
45.34 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
10 days left
EMD
90700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
akhnoor → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Bldg No P-31 At Gm Vihar Under Ge (N) Akhnoor.

BOQ

Name of Work:- SPL REPAIR TO BLDG NO P-31 AT GM VIHAR UNDER GE (N) AKHNOOR.
Sl. No. Item Description
1Demolition / taking down of existing old tarfelt , water proofing membrane, water proofing plaster of any description any type over RCC roof including any roof tiles, cement mortar screed, concrete screed of any thickness, for fixing of angle iron for water tank postion, incuding making good the surface by concrete to smooth surface complete all as specified and as directed.
2Rendering 15mm thick cement plaster with cement mortar(1:3) with water proofing compound on fair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra lime or cement ) all as specified and directed.( Water proof compound rate is not paid seperatly.)
3Supply only liquid water proofing compound conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement)
4Roof treatment :- Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 150 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints.(c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrane and dusted with dry sand @ 0.50 to 1 Kg/sqm. (i) On Non-accesible roof : After providing (a) to (c) provide aluminium paint as per manufacturer instructions. (ii) Coved fillet in PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) of required radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall/mumty around opening and treatment mentioned above shall be applied followed by a cement plaster 20mm thick in cement mortar(1:6). Note : (i) Roof treatment work shall be carried out through approved manufacturers only or through their authorised personal only.
5Sunken Floor treatment :-Providing and laying of water proofing treatment to sunken portion including vertical portion by applying cement slurry mixed with acrylic based polymer modified cementitious composite compound of make as specified and approved including demolition and filling of sunken floor with & including PCC 1:5:10 type E-2 (using 40mm brick aggregate).(a) First layer of slurry of cement @0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours.(b) Second layer of slurry of cement @0.242 kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/Sqm. This layer allowed to air cure for 4 Hours.(c) 15mm thick plaster in CM 1:3 mixed with WP compound to be provided while concrete is still green.(d) Joint of/Trap/WC/Soil pipes shall be properly sealed with sealing compound.Note:(a) Concrete for sunken slabs shall be mixed with WP compounds as per manufacturer's instructions. Before carrying out water proofing treatment the sunken slab shall be tested with water for 48 hours for any leakage /dampness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested before passing for next stage. (The rate quoted includes water proofing compound as per manufacturers instructions).(b) Please note that only floor area shall be measured for payment purpose.
6Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed.
7Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed.
8Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
9Rendering 15mm thick cement plaster with cement mortar(1:4) on other than fair faces of brick work or stone masonry surfaces or one side of lathing and finished even and smooth without using extra cement complete all as specified and as directed.
10Rendering 10mm thick cement plaster with cement mortar(1:6) on other than fair faces of brick work or stone masonry surfaces or one side of lathing and finished even and smooth without using extra cement complete all as specified and as directed.
11Applying 3mm thick wall care putty in two layers over newly plastered surfaces of wall, complete all as specified and directed.
12Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement, complete all as specified and as directed.
13Complete removal of exising treatment of old surfaces all as specified and as directed.
14Preparation of new plastered and unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
15Preparation of old plastered and unplastered surfaces of wall and applying two coat of oil bound distemper complete all as specified and as directed.
16Preparation of new plastered and unplastered surfaces , applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered surfaces, complete all as specified and directed.Note:-(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE.(ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same.
17Complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old plastered surfaces, complete all as specified and directed.Note:-(i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE.(ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same.
18Preparation of old decorated surface and applying two coat of Oil bound distemper on ceiling, complete all as speicfied and directed.
19Preparation of new plastered and unplastered surfaces on ceiling and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
20Repair to balcony/ Facia and soffit of chajjas etc by taking down old rendering and applying 20 to 25mm thick cement plaster to match the existing thickness in CM 1:3 and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqm in width or girth including preparation of surface and applying two coats of apex as required over one coat of primer including necessary formwork/scaffolding work upto height 7mtr above ground level of bldg complete all as specified and as directed.
21Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed.
22PCC 1:2:4 type B-0, (using 12.5mm graded crushed stone aggregate) as in sub base / levelling cousre including finishing surface of concrete topping even and rough , complete all as specified and as directed.
23Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as directed.
24Reinforcement cement concrete(nominal mix) type B1 1:2:4 using (20mm graded crushed stone aggregatge) for Chajjas/Balcony/Landing work as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
25Mild steel bars 10mm dia TMT Bars and over cut to length bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with and includig mild steel wire not less than 0.9mm dia or securing with clips complete fixed in repairs all as specified and directed.
26Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including sup- ports, overhangs, etc. complete all as specified and directed.
27Demolition of stone slab and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc. complete all as specified and directed.
28Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
29Green Marble work 18mm to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) inclduing pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Green marble with & including 15mm thick screed bed/base in CM 1:4, roughening/cleaning to existing surface of old concrete floor by picking, sweeping clean and washing down with water to remove dirt/dust and brushing neat cement slurry with 3.0 kg of cement per sqm all as specified and as approved.Note : A holes must be drilled in cooking platform for gas pipe.
30Vitrified ceramic tiles (light shade) 10mm thick (Square/rectangular) area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 complete all as specified and directed.
31Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed.
32Glazed ceramic tile 450x300x7mm/450x300x7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick rendering in cement and sand mortar 1:4 complete all as specified.
33Chequered cement concrete tiles 25cmx25cmx22-25mm/300mmx300mmx 25mm thick laid & jointed with grey cement and pointed in neat cement slurry mixed with with pigment as in path/hardstanding laid over & including15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes all as specified and directed.
34Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 Sqm all as specified and as directed.
35Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) nexc 1.50 sqm and n.exc 4.00 Sqm each and removing from site all as specified and directed.
36Factory made Pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 01 Nos 25x3mm thick flat iron projecting 10cm on either side & tarring back of chowkats and holdfasts with & including PCC 1:3:6 type C-0 as in back fitting of pressed steel frame, complete all as specified and as directed.
37Factory made Pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 01 Nos 25x3mm thick flat iron projecting 10cm on either side & tarring back of chowkats and holdfasts with & including PCC 1:3:6 type C-0 as in back fitting of pressed steel frame, complete all as specified and as directed.
38Factory made solid core PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC sheet, 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap inserted for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified & shown in relevant drawing of item No. 08080 in MES Schedule (Part-II) and directed.
39Solid PVC Door/ Almirah/Kitchen/Cupboard frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.
40PCC 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate) as in filling of roof kerbs or pressed steel frame as in 50 mm parapet coping, roof kerbs or in lintels upto 1.5m clear span, cills, plinth courses, string courses, coping, kneelers etc all as specified and directed.
41Plain cement Concrete 1:3:6 type-C1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts, plinth band, bed blocks, benching and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified.
42Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
43Powder coated aluminium anodised door shutters(minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
44Anodised aluminium grill ( anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and directed.
45Powder coated anodised aluminium window / ventilator( glazed / gauged skeleton shutter ), (minimum thickness of powder coating 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinges type B-21 100mm long (2 No. ) suitable handle (1 No.) complete all as specified and as directed.
4604 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed.
47Figured glass sheet, 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
4835mm thick flush shutters, solid core with particle board exterior grade as per IS 2202 of 199 (Part-I) flush door shall be internally lipped as per clause .8.52.2 of SSR Part-I 2009, complete all as specified & as directed.
4930 mm thick, 2nd class hard wood , glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified.
50Galvanized mild steel wire-cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
51300mm Mild steel ordinary rat tail rod pattern springs including roller and roller plate fixed, complete all as specified and directed.
52Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed.
53Extruded aluminium alloy handles, fabricated type, anodised of size 100mm and fixed, complete all as specified and directed.
54150 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed.
55Hasp and stapple safety type of aluminium anodised 100 mm long as a cupboard locker, complete all as specified.
5675 mm butt hinges, medium weight cold rolled mild steel, complete all as specified.
57300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified.
58Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue,nodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed.
59Pre laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter, 12/19 mm thick, complete all as specified and directed.
60Kitchen cabinets of PVC Solid board(wooden texture) size 900mmx750mmx600mm, including partitions, shelves and drawers with brass sliding rails,channels,door handles, door catchers, overall cabinet internally and externally made with both side PVC laminated termite proof board, 18/19 mm thick, ISI marked including PVC kitchen/cup board frame of size 18mmx63mm made out of 18mm thick PVC pre-laminated ply coloured and frame shall be fixed with 50mm long steel screw inside using drilling machine and plastic fasteners, having following specifications:.....Contd to Srl item No 110.01 Please Enable Macros to View BoQ information
61Kitchen cabinets of PVC Solid board(wooden texture) size 900mmx750mmx600mm, including partitions, shelves and drawers with brass sliding rails,channels,door handles, door catchers, overall cabinet internally and externally made with both side PVC laminated termite proof board, 18/19 mm thick, ISI marked including PVC kitchen/cup board frame of size 18mmx63mm made out of 18mm thick PVC pre-laminated ply coloured and frame shall be fixed with 50mm long steel screw inside using drilling machine and plastic fasteners, having following specifications:.....Contd to Srl item No 110.01 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56240318
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45.34 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Bldg No P-31 At Gm Vihar Under Ge (N) Akhnoor.
Basic Detail
Tender No GE(N)/AKH-39/2026-27
Bidding Type Tender
Location
City akhnoor
State Jammu and Kashmir
Key Dates
Publish Date 30 Jun 2026
Submission Date 21 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 45.34 Lakhs
Tender Fee 500
EMD 90700
Exemption Available
Document List
Tendernotice_1.pdf
0bd67643-149c-4ec1-9384-552ac23022b9.html
BOQ_868285.xls
Tender392627.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

0bd67643-149c-4ec1-9384-552ac23022b9.html

xls

BOQ_868285.xls

pdf

Tender392627.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender