Tender For Maintenance/ Servicing And Day To Day Complaint Of Extractor Fan, Air Ciculation Fan, Geysers, Energy Saving Luminaries And Connected Work At Sector D Under Ge 865 Ews
Tender Value
38.45 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
19 days left
EMD
76900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Maintenance/ Servicing And Day To Day Complaint Of Extractor Fan, Air Ciculation Fan, Geysers, Energy Saving Luminaries And Connected Work At Sector D Under Ge 865 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Rewinding of burnt windings of Exhaust fans of size 450 mm size including dismantling from location and removing the burnt out winding, cleaning the stator with CTC solution to remove the burnt slots, rewinding the same with new super enamelled copper wire same gauge and size /number of turns, varnishing the winding completely, replacement of unserviceable minor/ major spares and reassembling, fixing in its original position, testing complete all as specified and/or as directed by Engr-in-Charge. (Major spares such as gun metal bushing, condensor, ball beaing etc. replaced will be measured & paid seperately) |
| 2 | All as per Srl item No 01 above, but of size 300 mm. |
| 3 | All as per Srl item No 01 above, but of size 250 mm. |
| 4 | Supply and fix Ball bearing suitable for Exhaust fan of size 450mm sweep of any make complete all as specified and/or as directed by Engr-in-Charge. |
| 5 | Supply and fix Ball bearing suitable for Exhaust fan of size upto 300mm sweep of any make complete all as specified and/or as directed by Engr-in-Charge. |
| 6 | Supply and fix Condensor 2.5 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and/or as directed by Engr-in-Charge. |
| 7 | Supply and fix Condensor 4 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and/or as directed by Engr-in-Charge. |
| 8 | Supply and fix gun metal bushings suitable for Exhaust fan of size up to 300 mm sweep of any make complete all as specified and/or as directed by Engr-in-Charge. |
| 9 | Supply and fix gun metal bushings suitable for Exhaust fan of size up to 450 mm sweep of any make complete all as specified and/or as directed by Engr-in-Charge. |
| 10 | Taking down old unserviceable exhaust fan of capacity upto 300mm sweep from site and shifting to civil workshop for removing burnt winding, ball bearing, bushes, broken wings, condenser and deteriorated louver & rewinding with new super enamelled fine copper gauge of same size and replacing with new ball bearings, bushes, condenser of 2.5 MFD, wings, louvers and bring back to site and refixing the same in its original position and testing, complete all as specified and/or as directed by Engr-in-Charge. |
| 11 | All as per Srl Item No 10 above, but exhaust fan of capacity upto 250mm sweep. |
| 12 | All as per Srl Item No 10 above, but exhaust fan of capacity upto 200mm sweep. |
| 13 | All as per Srl Item No 10 above, but exhaust fan of capacity upto 450mm sweep iron body. |
| 14 | Taking down carefully the existing aluminium/copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fan regulators, lamp holders, call bell, bell pushes any type etc by unscrewing and taken away from site complete and make good the disturbed surface as existing complete all as specified and/or as directed by Engr-in-Charge. |
| 15 | Material and labour for point wiring with 1.5 sqmm (nominal Area) FRLSH PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit (ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable size including concealed PVC/MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and/ or as directed for the followings:- |
| 16 | One light/exhaust fan point controlled by one way switch |
| 17 | One switch socket outlet 6 Amps, 230 volts point on same board |
| 18 | One switch socket outlet 6 Amps, 230 volts point on independent board |
| 19 | All as per Srl item No 15 above, but using cable of size 4 Sqmm. |
| 20 | Supply and fix in replacement of Switch piano flush button single pole 6 Amps 230 volts one way complete all as specified and/or as directed by Engr-in-Charge. |
| 21 | Supply and fix switch Socket out let two in one 5 pin 6 Amps flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge. |
| 22 | Supply and fix switch Socket combination out let multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as specified and/or as directed by Engr-in-Charge. |
| 23 | Supply and fix in replacement of MCB SPN 63 Amp 240 Volts AC ISI marked complete all as specified and/or as directed by Engr-in-Charge. |
| 24 | Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts 50 HZ complete all as specified and/or as directed by Engr-in-Charge. |
| 25 | Supply and fix in repair gang box 2 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge. |
| 26 | Supply and fix in repair gang box 3 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge. |
| 27 | Supply and fix in repair gang box 4 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge. |
| 28 | Supply and fix in repair gang box 6 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge. |
| 29 | Supply and fix in repair gang box 8 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge. |
| 30 | Taking down old unserviceable 15 Amp Gang Box switch socket combination and supply and fix switch socket combination out let multipurpopose 5 pin 6/16 Amps with box, 230 Volts complete all as specified and/or as directed by Engr-in-Charge. |
| 31 | Supply and fix in replacement LED single tube light fitting surface/ pendent mounting complete with batten for LED tube light 20 Watt warm white with extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete all as specified and/or as directed by Engr-in-Charge. |
| 32 | Supply and fix in repair round ultra sleek surface mounted slim aluminium body LED downlight 10 watts complete all as specified and/or as directed by Engr-in-Charge. |
| 33 | Supply and fix in repair square ultra sleek surface mounted slim aluminium body LED downlight 15 watts complete all as specified and/or as directed by Engr-in-Charge.. |
| 34 | Supply and fix Plug Top 15 Amps suitable for working on 230 volts 50 Hz AC supply complete all as specified and/or as directed by Engr-in-Charge. |
| 35 | Supply and fix Plug Top 5 Amps suitable for working on 230 volts 50 Hz AC supply complete all as specified and/or as directed by Engr-in-Charge. |
| 36 | Taking down old unserviceable geyser of capacity 25 Ltrs from site, removing all unserviceable inner tank, assembly, heating element, outer tank, red green indicating lamp, flexible connection, safety valve, thermostat and supply and fix inner/outer tank, heating element, assembly, indicating lamp, flexible connection, thermostat and safety valve and fixing to its original position and testing complete all as specified and/or as directed by Engr-in-Charge. |
| 37 | All as per Srl Item No 33 above, but of capacity 50 Ltrs. |
| 38 | Supply and fix in replacement sheet metal enlcosure with 20 Amp 240 V socket plug top and MCBs single pole and neutral enclosure with two pin and earth plug and socket with one single pole 20 Amp MCB, complete all as specified and/or as directed by Engr-in-Charge. |
| 39 | Supply and fix in replacement of geyser assembly suitable for water heater of capacity upto 25 Ltrs to fix thermostat, heating element as of the existing model & size including all clamps with bolts and nuts etc. complete all as specified and/or as directed by Engr-in-Charge. |
| 40 | Taking down water heater storage type of capacity 25 Ltr of any make, Vertical/ horizontal type, after disconnecting the electric/ water connections and dismantling the heating elements / geyser assembly and descaling with descaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and/or as directed by Engr-in-Charge. |
| 41 | All as per Srl item No 37 above, but of capacity 50 Ltr. |
| 42 | All as per Srl item No 37 above, but of capacity 100 Ltr. |
| 43 | Supply and fix in replacement of water inlet/ outlet assembly suitable for storage water heater of 25 Ltrs capacity having provision of housing thermostate, heating element including providing rubber gaskets and holding nut bolts etc. complete all as specified and/or as directed by Engr-in-Charge. |
| 44 | All as per Srl item No 40 above, but of capacity 50 Ltr. |
| 45 | All as per Srl item No 40 above, but of capacity 100 Ltr. |
| 46 | Supply and fix in replacement of thermostat switch for water storage heater suitable for RACOLD/ ORISON/ PEARL type or equivalent, 220/ 240V 50Hz AC and temperature range of 32 - 88 degree centigrade ISI marked complete all as specified and/or as directed by Engr-in-Charge. |
| 47 | Supply and fix in replacement of heating elements suitable for water storage heater vertical type RACOLD/ ORISON/ PEARL type or equivalent, 220/240V AC 1500W and making connections and testing complete all as specified and/or as directed by Engr-in-Charge |
| 48 | Supply and fix in replacement of heating elements suitable for water storage heater vertical type RACOLD/ ORISON/ PEARL type or equivalent, 220/240V AC 2000W and making connections and testing complete all as specified and/or as directed by Engr-in-Charge. |
| 49 | Supply and fix in replacement of heavy duty PVC connections armoured type with brass union, nut, heat resistance type rubber washer for hot water complete all as specified and/or as directed by Engr-in-Charge. |
| 50 | Supply and fix in replacement of Indicating lamps suitable for storage water heater of any type & capacity, complete all as specified and/or as directed by Engr-in-Charge. |
| 51 | Supply and fix in replacement heating pillar rod as existing upto 2000 watt, 230 Volts complete all as specified and/or as directed by Engr-in-Charge. |
| 52 | Supply and fix in replacement stainless steel tank of capacity 25 Ltr for water geysers as per sample complete all as specified and/or as directed by Engr-in-Charge. |
| 53 | All as per Srl item No 49 above, but of capacity 50 Ltr. |
| 54 | All as per Srl item No 49 above, but of capacity 100 Ltr. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 days