Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56239968

Tender For Maintenance/ Servicing And Day To Day Complaint Of Extractor Fan, Air Ciculation Fan, Geysers, Energy Saving Luminaries And Connected Work At Sector D Under Ge 865 Ews

Issued by Statutory Bodies & Commissions/Committees · leh, Ladakh
Tender Value
38.45 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
19 days left
EMD
76900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Maintenance/ Servicing And Day To Day Complaint Of Extractor Fan, Air Ciculation Fan, Geysers, Energy Saving Luminaries And Connected Work At Sector D Under Ge 865 Ews

BOQ

Name of Work:- MAINTENANCE/ SERVICING AND DAY TO DAY COMPLAINT OF EXTRACTOR FAN, AIR CICULATION FAN, GEYSERS, ENERGY SAVING LUMINARIES AND CONNECTED WORK AT SECTOR D UNDER GE 865 EWS
Sl. No. Item Description
1Rewinding of burnt windings of Exhaust fans of size 450 mm size including dismantling from location and removing the burnt out winding, cleaning the stator with CTC solution to remove the burnt slots, rewinding the same with new super enamelled copper wire same gauge and size /number of turns, varnishing the winding completely, replacement of unserviceable minor/ major spares and reassembling, fixing in its original position, testing complete all as specified and/or as directed by Engr-in-Charge. (Major spares such as gun metal bushing, condensor, ball beaing etc. replaced will be measured & paid seperately)
2All as per Srl item No 01 above, but of size 300 mm.
3All as per Srl item No 01 above, but of size 250 mm.
4Supply and fix Ball bearing suitable for Exhaust fan of size 450mm sweep of any make complete all as specified and/or as directed by Engr-in-Charge.
5Supply and fix Ball bearing suitable for Exhaust fan of size upto 300mm sweep of any make complete all as specified and/or as directed by Engr-in-Charge.
6Supply and fix Condensor 2.5 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and/or as directed by Engr-in-Charge.
7Supply and fix Condensor 4 MFD 230 V suitable for Exhaust fan of any sweep/size complete all as specified and/or as directed by Engr-in-Charge.
8Supply and fix gun metal bushings suitable for Exhaust fan of size up to 300 mm sweep of any make complete all as specified and/or as directed by Engr-in-Charge.
9Supply and fix gun metal bushings suitable for Exhaust fan of size up to 450 mm sweep of any make complete all as specified and/or as directed by Engr-in-Charge.
10Taking down old unserviceable exhaust fan of capacity upto 300mm sweep from site and shifting to civil workshop for removing burnt winding, ball bearing, bushes, broken wings, condenser and deteriorated louver & rewinding with new super enamelled fine copper gauge of same size and replacing with new ball bearings, bushes, condenser of 2.5 MFD, wings, louvers and bring back to site and refixing the same in its original position and testing, complete all as specified and/or as directed by Engr-in-Charge.
11All as per Srl Item No 10 above, but exhaust fan of capacity upto 250mm sweep.
12All as per Srl Item No 10 above, but exhaust fan of capacity upto 200mm sweep.
13All as per Srl Item No 10 above, but exhaust fan of capacity upto 450mm sweep iron body.
14Taking down carefully the existing aluminium/copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fan regulators, lamp holders, call bell, bell pushes any type etc by unscrewing and taken away from site complete and make good the disturbed surface as existing complete all as specified and/or as directed by Engr-in-Charge.
15Material and labour for point wiring with 1.5 sqmm (nominal Area) FRLSH PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit (ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable size including concealed PVC/MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and/ or as directed for the followings:-
16One light/exhaust fan point controlled by one way switch
17One switch socket outlet 6 Amps, 230 volts point on same board
18One switch socket outlet 6 Amps, 230 volts point on independent board
19All as per Srl item No 15 above, but using cable of size 4 Sqmm.
20Supply and fix in replacement of Switch piano flush button single pole 6 Amps 230 volts one way complete all as specified and/or as directed by Engr-in-Charge.
21Supply and fix switch Socket out let two in one 5 pin 6 Amps flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge.
22Supply and fix switch Socket combination out let multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as specified and/or as directed by Engr-in-Charge.
23Supply and fix in replacement of MCB SPN 63 Amp 240 Volts AC ISI marked complete all as specified and/or as directed by Engr-in-Charge.
24Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts 50 HZ complete all as specified and/or as directed by Engr-in-Charge.
25Supply and fix in repair gang box 2 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge.
26Supply and fix in repair gang box 3 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge.
27Supply and fix in repair gang box 4 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge.
28Supply and fix in repair gang box 6 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge.
29Supply and fix in repair gang box 8 module for mounting of switch and socket flush type 230 volts complete all as specified and/or as directed by Engr-in-Charge.
30Taking down old unserviceable 15 Amp Gang Box switch socket combination and supply and fix switch socket combination out let multipurpopose 5 pin 6/16 Amps with box, 230 Volts complete all as specified and/or as directed by Engr-in-Charge.
31Supply and fix in replacement LED single tube light fitting surface/ pendent mounting complete with batten for LED tube light 20 Watt warm white with extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete all as specified and/or as directed by Engr-in-Charge.
32Supply and fix in repair round ultra sleek surface mounted slim aluminium body LED downlight 10 watts complete all as specified and/or as directed by Engr-in-Charge.
33Supply and fix in repair square ultra sleek surface mounted slim aluminium body LED downlight 15 watts complete all as specified and/or as directed by Engr-in-Charge..
34Supply and fix Plug Top 15 Amps suitable for working on 230 volts 50 Hz AC supply complete all as specified and/or as directed by Engr-in-Charge.
35Supply and fix Plug Top 5 Amps suitable for working on 230 volts 50 Hz AC supply complete all as specified and/or as directed by Engr-in-Charge.
36Taking down old unserviceable geyser of capacity 25 Ltrs from site, removing all unserviceable inner tank, assembly, heating element, outer tank, red green indicating lamp, flexible connection, safety valve, thermostat and supply and fix inner/outer tank, heating element, assembly, indicating lamp, flexible connection, thermostat and safety valve and fixing to its original position and testing complete all as specified and/or as directed by Engr-in-Charge.
37All as per Srl Item No 33 above, but of capacity 50 Ltrs.
38Supply and fix in replacement sheet metal enlcosure with 20 Amp 240 V socket plug top and MCBs single pole and neutral enclosure with two pin and earth plug and socket with one single pole 20 Amp MCB, complete all as specified and/or as directed by Engr-in-Charge.
39Supply and fix in replacement of geyser assembly suitable for water heater of capacity upto 25 Ltrs to fix thermostat, heating element as of the existing model & size including all clamps with bolts and nuts etc. complete all as specified and/or as directed by Engr-in-Charge.
40Taking down water heater storage type of capacity 25 Ltr of any make, Vertical/ horizontal type, after disconnecting the electric/ water connections and dismantling the heating elements / geyser assembly and descaling with descaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and/or as directed by Engr-in-Charge.
41All as per Srl item No 37 above, but of capacity 50 Ltr.
42All as per Srl item No 37 above, but of capacity 100 Ltr.
43Supply and fix in replacement of water inlet/ outlet assembly suitable for storage water heater of 25 Ltrs capacity having provision of housing thermostate, heating element including providing rubber gaskets and holding nut bolts etc. complete all as specified and/or as directed by Engr-in-Charge.
44All as per Srl item No 40 above, but of capacity 50 Ltr.
45All as per Srl item No 40 above, but of capacity 100 Ltr.
46Supply and fix in replacement of thermostat switch for water storage heater suitable for RACOLD/ ORISON/ PEARL type or equivalent, 220/ 240V 50Hz AC and temperature range of 32 - 88 degree centigrade ISI marked complete all as specified and/or as directed by Engr-in-Charge.
47Supply and fix in replacement of heating elements suitable for water storage heater vertical type RACOLD/ ORISON/ PEARL type or equivalent, 220/240V AC 1500W and making connections and testing complete all as specified and/or as directed by Engr-in-Charge
48Supply and fix in replacement of heating elements suitable for water storage heater vertical type RACOLD/ ORISON/ PEARL type or equivalent, 220/240V AC 2000W and making connections and testing complete all as specified and/or as directed by Engr-in-Charge.
49Supply and fix in replacement of heavy duty PVC connections armoured type with brass union, nut, heat resistance type rubber washer for hot water complete all as specified and/or as directed by Engr-in-Charge.
50Supply and fix in replacement of Indicating lamps suitable for storage water heater of any type & capacity, complete all as specified and/or as directed by Engr-in-Charge.
51Supply and fix in replacement heating pillar rod as existing upto 2000 watt, 230 Volts complete all as specified and/or as directed by Engr-in-Charge.
52Supply and fix in replacement stainless steel tank of capacity 25 Ltr for water geysers as per sample complete all as specified and/or as directed by Engr-in-Charge.
53All as per Srl item No 49 above, but of capacity 50 Ltr.
54All as per Srl item No 49 above, but of capacity 100 Ltr. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56239968
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38.45 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Maintenance/ Servicing And Day To Day Complaint Of Extractor Fan, Air Ciculation Fan, Geysers, Energy Saving Luminaries And Connected Work At Sector D Under Ge 865 Ews
Basic Detail
Tender No 138WE/L-30/2026-27
Bidding Type Tender
Location
City leh
State Ladakh
Key Dates
Publish Date 30 Jun 2026
Submission Date 21 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 38.45 Lakhs
Tender Fee 500
EMD 76900
Exemption Available
Document List
925f5113-3b9d-4b6e-ae00-f26f22e17acc.html
BOQ_868217.xls
TenderL302627.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
html

925f5113-3b9d-4b6e-ae00-f26f22e17acc.html

xls

BOQ_868217.xls

pdf

TenderL302627.pdf

pdf

Tendernotice_1.pdf

TenderDetail